• Title/Summary/Keyword: appliance

Search Result 1,569, Processing Time 0.025 seconds

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK (타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교)

  • Lee, Young-Jae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

Self-inflicted Tongue Ulceration in a Patient with Tourette Syndrome: A Case Report (뚜렛 증후군 환자에서 자해로 인한 혀 손상 : 증례 보고)

  • Lee, Kkotnim;Kim, Miae;Hwang, Inkyung;Park, Jihyun;Mah, Yonjoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.3
    • /
    • pp.327-333
    • /
    • 2016
  • Tourette's syndrome is a chronic neuropsychiatric disorder characterized by the presence of vocal and multiple motor tics. Tics are defined as brief, intermittent, repetitive, unpredictable, purposeless, and stereotyped movements or sounds. Some patients experience physical pain from intense and complex tics. In addition, motor tics can result in self-injury which is a common feature of Tourette's syndrome. A 9-year-old boy was referred by the department of neuropsychiatry because of a severe tongue laceration. His parents reported that he had been biting his tongue irregularly for 2 months before referral and suffered from an intense burning sensation. The repeated biting resulted in ulcers on the tongue, which quickly worsened and led to progressive difficulty chewing and swallowing food. We offered to give him a two-piece removable appliance to limit tongue biting; it was made of soft silicone and fitted to both the maxillary and mandibular arches. As we emphasized that the device could help alleviate his pain, he agreed to accept it and adapted well. Just 3 weeks later, his tongue lesions had healed significantly.

Comparison in Demineralization Resistance of Resin Infiltration and 1.23% Acidulated Phosphate Fluoride in Bovine Teeth (우치에서 레진 침투법 및 불소 적용의 탈회 저항성 비교)

  • Lee, Doo-Young;Kim, Ik-Hwan;Song, Je Seon;Kim, Seong-Oh;Son, Heung Kyu;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.2
    • /
    • pp.137-143
    • /
    • 2018
  • The aim of this study is to compare the differences of the demineralization resistance of resin infiltration and 1.23% acidulated phosphate fluoride in bovine teeth with artificial caries. We applied 1.23% Acidulated phosphate fluoride (APF) gel and $Icon^{(R)}$ caries infiltrant on the artificial bovine enamel carious lesion and then demineralized all samples. The depth of demineralization was measured by using Confocal Laser Scanning Microscope (CLSM) and observed the roughness and irregularity of the enamel was observed by Scanning Electron Microscope (SEM). In this experiment with demineralization resistance on smooth artificial carious lesion, less depth of demineralization, roughness, and irregularity of enamel was observed in APF gel and $Icon^{(R)}$ group than in the control group. There was no significant difference between the depth of demineralization of 1.23% APF gel and $Icon^{(R)}$ caries infiltrant group. However, resin infiltration is beneficial as less roughness and irregularity was observed on the enamel surface than when 1.23% APF gel is applied.

A FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION AND DISPLACEMENT OF an in-vitro HUMAN MANDIBLE TO THE ORTHOPEDIC FORCE (정형력(整形力)에 대(對)한 하악골내(下顎骨?)의 응력분산(應力分散)과 변위(變位)에 관(關)한 유한요소법적(有限要素法的) 분석(分析))

  • Choue, Ho Koo
    • The korean journal of orthodontics
    • /
    • v.14 no.1
    • /
    • pp.75-92
    • /
    • 1984
  • This study attempted to analyze the distribution of stress, to examine the bending effect in the mandible according to the pulling directions and determine on which pulling directions are adequate when an orthopedic force was applied to the mandible. An orthopedic force, 500gm, was applied to the gnathion, one point of the chin area, in three directions. The three directions were ; high puli' from gnathion to the center of condyle head, and vertical pull, from gnathion to a parallel line with the posterior border of the ramus, and medium pull, from the gnathion to a parallel line with the lower border of mandible. The distribution of principal stress, bending moment and amount of displacement within the mandible was analyzed by a 3-dimensional finite element method and that of the various portions of mandible were computed and compared according to the pulling directions. The results were as follows : 1. The bending moment of each part of a mandible has been found to be markedly larger in case of vertical pull than in case of either high pull or medium pull. In vertical pull the bending moment turned out to largest at the condyle head and neck portion, the gonial angle portion, the coronoid portion and the ascending ramus portion, respectively, while comparatively large at the cuspid and bicuspid portion and the first molar portion. In case of high pull it was largest at the gonial angle portion and becoming smaller at the coronoid portion, the ascending ramus portion, the condyle head and neck portion, and the cuspid and bicuspid portion, in that order. In case of medium pull, however, the bending moment was largest at the condyle head and neck portion, becoming smaller at the first molar portion, the ascending ramus portion, the coronoid portion, the cuspid and bicuspid portion, and gonial angle portion, in that order. 2. As for the bending effect it was calculated to be mostly oriented downward at the mandibular body and backward at the mandibular ramus in both high pull and vertical pull. In case of medium pull it was oriented upward at the mandibular body and forward at the mandibular ramus. 3. The bending effect also turned out to be mostly oriented outward in case of high pull and medium pull, and inward in vertical pull. 4. At the mandibular body and ramus, the bending effect in the upward-downward direction and that in the forward-backward direction were found to be larger than in the inward-outward direction. 5. If and when we expect any correcting effect on the mandibular protrusion by means of the chin cup appliance, we can say sure as conclusion that high pull and vertical pull are more effective than medium pull.

  • PDF

Treatment modalities for Korean patients with unilateral hemifacial microsomia according to Pruzansky-Kaban types and growth stages

  • Yang, Il-Hyung;Chung, Jee Hyeok;Yim, Sunjin;Cho, Il-Sik;Kim, Sukwha;Choi, Jin-Young;Lee, Jong-Ho;Kim, Myung-Jin;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.50 no.5
    • /
    • pp.336-345
    • /
    • 2020
  • Objective: To investigate the treatment modalities (Tx-Mods) for patients with unilateral hemifacial microsomia (UHFM) according to Pruzansky-Kaban types and growth stages. Methods: The samples consisted of 82 Korean UHFM patients. Tx-Mods were defined as follows: Tx-Mod-1, growth observation due to mild facial asymmetry; Tx-Mod-2, unilateral functional appliance; Tx-Mod-3, fixed orthodontic treatment; Tx-Mod-4, growth observation due to a definite need for surgical intervention; Tx-Mod-5, unilateral mandibular or bimaxillary distraction osteogenesis (DO); Tx-Mod-6, maxillary fixation using LeFort I osteotomy and mandibular DO/sagittal split ramus osteotomy; Tx-Mod-7, orthognathic surgery; and Tx-Mod-8, costochondral grafting. The type and frequency of Tx-Mod, the number of patients who underwent surgical procedures, and the number of surgeries that each patient underwent, were investigated. Results: The degree of invasiveness and complexity of Tx-Mod increased, with an increase in treatment stage and Pruzansky-Kaban type (initial < final; [I, IIa] < [IIb, III], all p < 0.001). The percentage of patients who underwent surgical procedures increased up to 4.2 times, with an increase in the Pruzansky-Kaban type (I, 24.1%; IIa, 47.1%; IIb, 84.4%; III, 100%; p < 0.001). However, the mean number of surgical procedures that each patient underwent showed a tendency of increase according to the Pruzansky-Kaban types (I, n = 1.1; IIa, n = 1.5; IIb, n = 1.6; III, n = 2.3; p > 0.05). Conclusions: These findings might be used as basic guidelines for successful treatment planning and prognosis prediction in UHFM patients.

The Treatment Strategies of Non-surgical Approach for Dentofacial Asymmetry Patient (치열 안면 비대칭 환자의 비수술적 절충치료의 전략적 접근)

  • Lee, Kyung-Min;Lee, Sang-Min;Yang, Byung-Ho;Yun, Min-Sung;Lee, Ju-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.77-87
    • /
    • 2010
  • Skeletodental asymmetries are common and asymmetric orthodontic treatments are very difficult to correct successfully. The cause of asymmetries can be the skeletal asymmetry, dental, or functional, or combinations of these causes. Skeletodental asymmetries can be the result of congenital factors, such as hemifacial microsomia and environmental factors, such as trauma. Optimal treatment outcome of the severe facial asymmetry requires the orthognathic surgery. Mild asymmetry problem can be treated by only orthodontic treatment. The orthodontic treatment of asymmetry is usually difficult. Facial asymmetry orthodontic treatment are primarily based on proper diagnosis and careful treatment planning. Side effects of asymmetric elastic to treat midline discrepancies are canted occlusal plane, tipped incisors and unesthetic results. In the management of dental arch asymmetries, the clinician should select the appropriate force system and the appliance design necessary to address the asymmetry while minimizing undesirable side effects. This report presents treatment strategies for the treatment of skeletodental asymmetry. In this case report, the clinical case with midline discrepancies treated by optimal mechanics is described. Through diagnosis and strategic treatment mechanics can obtain proper midline correction with minimal side effects.

The success rate of Mg-incorporated oxidized implants in partially edentulous patients: a prospective clinical study (부분 무치악 환자에서 마그네슘 이온주입 임플란트의 성공률에 대한 전향적 임상연구)

  • Choi, Su-Jung;Yoo, Jung-Ho;Lee, Ku-Bok;Kim, Jin-Wook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.176-183
    • /
    • 2012
  • Purpose: This study examined the clinical success rate of Mg titanate implants (M Implant system, Shinhung, Korea), which employ a Mg coating method, by evaluating the marginal bone loss and implant stability using radiographs and Osstell$^{(R)}$, over a 1 year. Materials and methods: The locations of the implants placement were divided into 4 areas; the maxillary and mandibular premolars and molars. In the maxilla, 8 and 9 implants were inserted in the premolar and molar areas, respectively. In the mandible, 11 and 51 implants were inserted in the premolar and molar areas. Marginal bone loss and ISQ of all implants (79) were measured after insertion, mounting the prosthetic appliance, and 1, 3, 6, and 12 months after loading. The marginal bone loss was measured from the radiograph using XCP bite, which was customized, and the implant stability measured using Osstell$^{(R)}$. Fisher's exact test (${\alpha}$=.05) was used to compare the success rates of each region. Results: The mean marginal bone loss for the upper and lower jaws were 1.537 mm and 1.172 mm. The mobility showed a non-significant reduction or increase according with time. The success rates were accounted for 94.12% and 98.39% in the upper and lower jaws; the premolars and molars were accounted for 100% and 96.67%. The two cases of early failure resulted from failure of primary stability during implant insertion. The late failures were not observed for 1 year after adding a loading to the implants. Conclusion: The Mg titanate implant showed good primary stability and good clinical results in both healing and function.

EFFECTS OF POLYPHOSPHATE MIXED IN ACRYLIC RESIN ON THE ATTACHMENT AND GROWTH OF ORAL BACTERIA (Acrylic Resin에 혼합된 Polyphosphate가 미생물의 부착 및 성장에 미치는 영향)

  • Hong, Sun-Hee;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.69-79
    • /
    • 2003
  • The purpose of this present study was to develop a new way of self-curing acrylic resin, using commercially available polyphosphate, Calgon, which is known to be antimicrobial and safe. For the study, polyphosphate(polyP) was blended with acrylic powder and devided into four groups as follows: no polyP(control), 1% polyP, 2% polyP, and 3% polyP. For the experiment, Streptococcus mutans GS5, Streptococcus sobrinus 6715, Streptococcus gordonii G9B and Challis, Porphyromonas gingivalis 2561, and Candida albicans ATCC 90027 were used. Resin specimens in each group were tested in vitro for the purpose of investigating the effect of polyP on the microbial attachment, growth and hydrophobicity of the resin surface. The results were as follows. 1. PolyP added to the acrylic resin decreased attachment of S. mutans GS5, S. sobrinus 6715, S. gordonii G9B. The greater binding inhibition was found in acrylic resin polymerized with polyP at higher concentrations. 2. The addition of polyP to acrylic resin failed to significantly affect the growth of the tested microorganisms. 3. The addition of polyP to acrylic resin seemed to reduce hydrophobicity of the acrylic resin. PolyP in acrylic resin does not seem to exert a direct antibacterial activity, but rather inhibit attachment of oral bacteria, especially mutans streptococci to saliva-coated acrylic resin. The acrylic resin reduces attachment of streptococci may be due to the decreased hydrophobicity caused by polyP added to the resin. PolyP may be included to acrylic resin to inhibit dental caries which often occurs when removable acrylic resin appliance is placed.

  • PDF

MAXILLARY MOLAR DISTALIZATION WITH THE BONE-SUPPORTED PENDULUM (Bone-supported pendulum을 이용한 상악대구치 원심이동)

  • Jang, Yong-Gul;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.464-474
    • /
    • 2009
  • To distalize the maxillary molars, the traditional techniques such as extra-oral traction, Wilson distalizing arches, removable spring appliances and Schwarz plate-type appliances have been used. But, these need considerable patient cooperation. For minimal patient compliance, many practitioners use the pendulum appliances. Several clinical studies demonstrated pendulum is effective molar distalization appliance in the growing patient(using the premolars and the palate as anchorage). But unfortunately, maxillary anterior teeth also shift mesially as the molar moves distally. As a result anchorage loss is occurred. To overcome these disadvantages, we used bone-supported pendulum, combined the conventional pendulum with Skeletal Anchorage System(SAS). The miniscrew was implanted in the anterior paramedian region of the median palatal suture, which has comparatively sufficient bone thickness and is low risk to damage on the dental follicles. We report three cases, using bone-supported pendulum for the maxillary molar distalization in children. After treatment, we find out anchorage stability, minimal unfavorable anterior tooth movement and sufficient molar distalization.

  • PDF

THE DEVELOPMENT OF INDWELLING WIRELESS PH TELEMETRY OF INTRAORAL ACIDITY (구강 내 산도의 생체 내 측정을 위한 wireless pH telemetry의 개발)

  • Kim, Hyung-Jun;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • The purpose of this study was to develop the wireless pH telemetry lasting longer than 24 hours in the mouth to overcome the limits of conventional wire telemetry previously used for salivary and plaque pH measurement, and to assess its effectiveness. We developed a wireless pH telemeter which can measure and store the pH profile data during more than 24 hours. It was composed of intraoral part; pH sensor of antimony electrode, battery and microprocessor for data storage, and extraoral part; control/data receiver and data analyzing software which was newly made for this device. After inspecting wireless electrode for accurate measurement, it was attached to the removable intraoral appliance and delivered to the volunteer who was told to wear except brushing time, retrieved after 24 hours and finally the pH profile data was extracted and analyzed. When compared with conventional wire telemetry, this device showed similar results and induced less discomfort to examinees. The data showed pH changes at same time when examinees ate various scheduled foods and beverages. With this method it became possible to accurately measure pH changes within mouth for long time in accordance with individual's lifestyle, definitely reducing the discomfort inflicted to the examinees' life.

  • PDF