• Title/Summary/Keyword: apparatus

Search Result 4,312, Processing Time 0.032 seconds

An Optimal Location of Superconducting Fault Current Limiter in Distribution Network with Distributed Generation Using an Index of Distribution Reliability Sensitivity (신뢰도 민감도 지수를 이용한 복합배전계통 내 초전도한류기의 최적 위치에 관한 연구)

  • Kim, Sung-Yul;Kim, Wook-Won;Bae, In-Su;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.52-59
    • /
    • 2010
  • As electric power demand of customers is constantly increasing, more bulk power systems are needed to install in a network. By development of renewable energies and high-efficient facilities and deregulated electricity market, moreover, the amount of distributed resource is considerably increasing in distribution network consequently. Also, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. These changes make fault current increase. Therefore, the fault current will exceed a circuit breaker capacity. In order to solve this problem, replacing breaker, changing operation mode of system and rectifying transformer parameters can be taken into account. The SFCL(Superconducting Fault Current Limiter) is one of the most promising power apparatus. This paper proposes a methodology for on optimal location of SFCL. This place is defined as considering the decrement of fault current by component type and the increment of reliability by customer type according to an location of SFCL in a distribution network connected with DG(Distributed Generation). With case studies on method of determining optimal location for SFCL applied to a radial network and a mesh network respectively, we proved that the proposed method is feasible.

Train interval control and train-centric distributed interlocking algorithm for autonomous train driving control system (열차자율주행제어시스템을 위한 간격제어와 차상중심 분산형 연동 알고리즘)

  • Oh, Sehchan;Kim, Kyunghee;Choi, Hyeonyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.1-9
    • /
    • 2016
  • Train control systems have changed from wayside electricity-centric to onboard communications-centric. The latest train control system, the CBTC system, has high efficiency for interval control based on two-way radio communications between the onboard and wayside systems. However, since the wayside system is the center of control, the number of input trains to allow a wayside system is limited, and due to the cyclic-path control flows between onboard and wayside systems, headway improvement is limited. In this paper, we propose a train interval-control and train-centric distributed interlocking algorithm for an autonomous train-driving control system. Because an autonomous train-driving control system performs interval and branch control onboard, both tracks and switches are shared resources as well as semaphore elements. The proposed autonomous train-driving control performs train interval control via direct communication between trains or between trains and track-side apparatus, instead of relying on control commands from ground control systems. The proposed interlocking algorithm newly defines the semaphore scheme using a unique key for the shared resource, and a switch that is not accessed at the same time by the interlocking system within each train. The simulated results show the proposed autonomous train-driving control system improves interval control performance, and safe train control is possible with a simplified interlocking algorithm by comparing the proposed train-centric distributed interlocking algorithm and various types of interlock logic performed in existing interlocking systems.

A Combination Study on the Elevation Motion Friction Compensation Parameters in Gas Spring (1) (가스 스프링 Elevation 동작 마찰력 보상 변수 조합 연구 (1))

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.657-666
    • /
    • 2017
  • In this study, factor analysis was performed to reduce the friction in the elevation motion of a stand for a 50-inchtelevision. Pipe type cross-section control was used for accurate positioning control of the piston rod. The pipe type was also compared with a labyrinth-type crosssection for the orifice. The frictional force was then reduced using gas seal lip technology. Specifications were chosen, and a volume compensation experiment was carried out using an apparatus for compensating the volume of the cylinder, which is compressed by the volume of the piston rod. Based on CAE and experimental considerations, the labyrinth-type orifice is preferred for reducing friction. For the gas seal lip technology, outer and inner diameters of ${\Phi}20$ and ${\Phi}8$ for the hollow rod were more appropriate when assuming the weight of a 50-inch television to be 30kgf. The third is that the result of total consideration in stability problem and performance of volume compensation for specification decision and volume compensation experiment is determined the final speculation of hollow rod ?8x?4 and riveting system. The last is that the labyrinth orifice is not founded that of the ${\O}0.4{\sim}0.6$ orifice both tests on 300 mm intervals.

A study of fabrication micro bump for TSP testing using maskless lithography system. (Maskless Lithography system을 이용한 TSP 검사 용 micro bump 제작에 관한 연구.)

  • Kim, Ki-Beom;Han, Bong-Seok;Yang, Ji-Kyung;Han, Yu-Jin;Kang, Dong-Seong;Lee, In-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.674-680
    • /
    • 2017
  • Touch Screen Panel (TSP) is a widely used personal handheld device and as a large display apparatus. This study examines micro bump fabrication technology for TSP test process. In the testing process, as TSP is changed, should make a new micro bump for probing and modify the testing program. In this paper we use a maskless lithography system to confirm the potential to fabricatemicro bump to reducecost and manufacturing time. The requiredmaskless lithography system does not use a mask so it can reduce the cost of fabrication and it flexible to cope with changes of micro bump probing. We conducted electro field simulation by pitches of micro bump and designed the lithography pattern image for the maskless lithography process. Then we conducted Photo Resist (PR) patterning process and electro-plating process that are involved in MEMS technology to fabricate micro bump.

Decomposition of EVA(Ethylene vinyl acetate) used as an adhesion of photovoltaic(PV) module by ultrasonic irradiation in bath-type cleaner (Bath-type 초음파(超音波) 세척기(洗滌器)를 이용(利用)한 태양전지모듈 접착제(接着劑) EVA(Ethylene Vinyl Acetate) 분해특성(分解特性))

  • Kim, Young-Jin;Lee, Jae-Ryeong
    • Resources Recycling
    • /
    • v.20 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • Using ultrasonic irradiation, the separation and recovery of PV cell, made of silicon wafer, from PV module was carried out through selective decomposition of EVA used as an interlaminated binder. The ultrasonic cleaner of bath-type (Output: 130 W, Frequency: 40 kHz) was used as an ultrasonic apparatus in this research. With the fixed distance of 2 cm, from ultrasonic generator to PV cell, the experiment of EVA decomposition was performed in various organic solvents such as Toluene, Trichloroethylene, O-dichlorobenzene, Benzene. And also their concentrations and temperature was changed to survey the optimum conditions. However EVA can be decomposed perfectly at $55^{\circ}C$ within 160 min in 5 M of all kinds of solvent, PV cell may be recovered with being damaged or broken severely. This damage may be resulted from the swelling of EVA in the process of decomposition. Whereas, at the condition of 5 M at $65^{\circ}C$, PV cell can be recovered with the state of minor damage or crack. This implies that the decomposition rate of EVA increases with an increase of temperature, thereby EVA can be decomposed before the swelling of EVA layer. Conclusively, it is possible for PV cell to be recovered within 40 min, at $65^{\circ}C$ in 5 M, with less damage.

Driver's Status Recognition Using Multiple Wearable Sensors (다중 웨어러블 센서를 활용한 운전자 상태 인식)

  • Shin, Euiseob;Kim, Myong-Guk;Lee, Changook;Kang, Hang-Bong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.6
    • /
    • pp.271-280
    • /
    • 2017
  • In this paper, we propose a new safety system composed of wearable devices, driver's seat belt, and integrating controllers. The wearable device and driver's seat belt capture driver's biological information, while the integrating controller analyzes captured signal to alarm the driver or directly control the car appropriately according to the status of the driver. Previous studies regarding driver's safety from driver's seat, steering wheel, or facial camera to capture driver's physiological signal and facial information had difficulties in gathering accurate and continuous signals because the sensors required the upright posture of the driver. Utilizing wearable sensors, however, our proposed system can obtain continuous and highly accurate signals compared to the previous researches. Our advanced wearable apparatus features a sensor that measures the heart rate, skin conductivity, and skin temperature and applies filters to eliminate the noise generated by the automobile. Moreover, the acceleration sensor and the gyro sensor in our wearable device enable the reduction of the measurement errors. Based on the collected bio-signals, the criteria for identifying the driver's condition were presented. The accredited certification body has verified that the devices has the accuracy of the level of medical care. The laboratory test and the real automobile test demonstrate that our proposed system is good for the measurement of the driver's condition.

Bioequivalence Test of Gabapentin 800 mg Tablets (가바펜틴 800밀리그람 정제의 생물학적동등성시험)

  • Kim, Se-Mi;Shin, Sae-Byeok;Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • YAKHAK HOEJI
    • /
    • v.52 no.4
    • /
    • pp.299-305
    • /
    • 2008
  • Gabapentin, 1-(aminomethyl) cyclohexaneacetic acid, is a amino acid derivative, and is clinically effective in the treatment of neuropathic pain and partial seizures of epilepsy as a complementary therapy. The purpose of the present study was to evaluate the bioequivalence of two gabapentin tablets, $Neurontin^{R}$ tablet 800 mg (Pfizer Pharmaceuticals Co., Ltd.) and Gabapenin tablet 800 mg (Hanmi Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of gabapentin from the two gabapentin formulations in vitro was tested using KP VIII Apparatus II method with 0.06 M HCI dissolution media. Twenty six healthy male subjects, $23.85{\pm}2.24$ years in age and $69.40{\pm}11.11$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ crossover study was employed. After a single tablet containing 800 mg as gabapentin was orally administered, blood samples were taken at predetermined time intervals and the concentrations of gabapentin in serum were determined using HPLC with fluorescence detector. The dissolution profiles of two formulations were similar in the tested dissolution media. The pharmacokinetic parameters such as $AUC_{t}$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_{t}$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Neurontin^{R}$, were 1.28%, 0.63% and 0.62% for $AUC_{t}$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., $log0.9097{\sim}log1.1598$ and $log0.8919{\sim}log1.1262$ for $AUC_{t}$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Gabapenin tablet 800 mg was bioequivalent to $Neurontin^{R}$ tablet 800 mg.

Development of Dissolution Test for Itopride Hydrochloride Tablets and Tiropramide Hydrochloride Tablets (이토프리드염산염 정과 티로프라미드염산염 정의 용출시험법 개발)

  • Kim, Jung Hyun;Lee, Jong Hwa;Choi, Lan;Choi, Yeon Hee;Lee, Jong Chul;An, Ji Hye;Lee, Gwang Moon;Shim, Young Hoon;Kang, Shin-Jung;Sah, Hong-Kee;Choi, Hoo-Kyun;Kim, In-Kyu
    • YAKHAK HOEJI
    • /
    • v.57 no.3
    • /
    • pp.205-212
    • /
    • 2013
  • Dissolution test has been performed to control drug quality and to predict in vivo drug release profile of solid dosage forms, so there's a drift towards setting dissolution test instead of disintegration test. However, some solid dosage forms in Korea Pharmaceutical Codex (KPC) are not established the dissolution test yet, so these monographs are necessary to set the specification of dissolution test. In this study, we developed the specification and test method of dissolution test for itopride hydrochloride tablets and tiropramide hydrochloride tablets which are not established the dissolution test yet. According to the "Manual for Guideline Application for Validation of Analytical Procedures" and "Guidelines on Specification of Dissolution test for Oral dosage form" of Korean Pharmacopoeia (KP), we validated and established each development method. Based on the preliminary dissolution profile, we set the dissolution condition(paddle apparatus, pH 1.2 media, 50 rpm). For this condition, we performed the main dissolution test to determine the specification (45 min, 85%). Finally, we validated each analytical method by specificity, linearity, accuracy and precision. These developed methods will be included the next supplement of KPC and also contributed to the quality control of medicines.

A Study on Health-related PSR Model using Korean Working Conditions Survey Data (PSR 모델을 적용한 근로환경조사 지표 개발)

  • Kim, Youngsun;Jo, Jinnam
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.7
    • /
    • pp.1243-1255
    • /
    • 2014
  • This study is aimed at developing an index and indicator in the light of social factors by analyzing the basic materials on Korean working conditions survey to make it possible to grasp various working environment factors consequent on business type and to judge the industrial safety & health policy of the related area. For the purpose of developing an index, this study was conducted by benchmarking the OECD-suggested index development guidelines and overseas cases of index development. This study suggested indexes related to health by benchmarking OECD's press-state-response model. The press-state health-related indexes specified in Korean working condtions survey were found to consist of physical risk environment, working hours, business environment, and social environment, and its consequent 'state' items were comprised of mental health, physical health, absence from work due to health problems and work satisfaction as health-related items. As a result, it was found that the 'press-state index' for wage worker, regular employee, manager, clerks, expert & related personnel involved, and workers aged under 50 was relatively good; in contrast, the 'press-state index' for people aged over 50, owner-operator, daily job, skilled position in agriculture & fisheries, simple labor service, and apparatus & machines assembly worker was found to be relatively vulnerable.

A Case Study of Tkatchev stretched Motion by Technical Feedback in Horizontal Bars (기술처치에 의한 철봉 Tkatchev stretched 동작의 사례연구)

  • Back, Jin-Ho;Son, Won-Il
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.77-87
    • /
    • 2008
  • This study is to formulate strategy for subject who are selected as national team in horizontal bars event in apparatus gymnastics. For this, skill training program was applied to players for 8 weeks. Then it was analyzed by using 3D motion Analysis system to seek the difference between before and after using the program. There were decisive demerit element K's first try for Tkatchev stretched movement from low elevation and crooked body while elevating. Not only, the location of his center of mass is far and low and there was some concern in his landing due to bended his hip-joint, but also, it exposed weak point in retro-action followed technique. Thus, to overcome that weak point, the subject repeated practices on following; when preparing for Tkatchev stretched movement at downward for big spin, make sure extend shoulder angle faster, make sure Tap movement is short and concise using hip-joint angular while delaying Tap timing for folding the body, and moreover, while backlashing the body, used shoulder joint angle wide to pull up the body. As a result, the speed of vertical upward did rut increase when separation from the bar. However, height of elevation increased that the leg would rut hit the horizontal bar even straight up the hip-joint. Therefore, the movement itself provided magnificent motion and even helped decrease the demerits.