• 제목/요약/키워드: apartment complex

검색결과 711건 처리시간 0.027초

주거건물의 급탕방식별 급수.급탕헤더시스템 적용방안에 관한 연구 (A Study on the Application Method of Cold & Hot Water Manifold System for Hot Water Supply System in Residential Buildings)

  • 차민철;제성호;석호태
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.79-88
    • /
    • 2008
  • Hot water is used by having a wash, dishes, taking tub and drinking water in residential buildings, and the use objective is to raise comfort of human body sense, washing and sterilization effect and so on. Cold & hot water supply system is understanded simpler than HVAC systems relatively, so it is true that pace of performance improvement is slower than other systems for plan and technical development. In this study, the performance evaluations are conducted under the condition of composition ratio by 1:1 for cold & hot water supply manifold system using functionally complex valves such as constant flow regulating valve and 3-way mixing valve in the area of $105.6m^2$ apartment which consist of the largest part of the whole apartment. Also, flow rate related to simultaneous use of faucets and change of hot water temperature are compared with the existing method.

공동주택조명 설비 기준 설정을 위한 조사 연구 (Investigation Research for Apartment House Lighting Equipment Standard Establishment)

  • 김동관;이순형;이경섭;김장열;전연수;정헌상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.562-564
    • /
    • 2001
  • Current interior lighting design way that is consisting uniformly by designer's experience or simple capacity calculation diversifies according to standard of living elevation and there is problem that do not reflect been individualising resident's change request in lighting plan, design properly. Therefore, because this resident's request, enough judgment data that is worth reflecting dissatisfaction item in design concretely or standard is not saved up in business post, had gotten into bottleneck at lighting design. Diagnose resident's consciousness and feedback degree about interior lighting to existent apartment complex in this research and examined improvement plan. As a result, in the case of illumination, wanted higher brightness and showed reason that is most Affirmativ about order way of lighting fixtures. The reason is because can select registration nine that want by oneself directly. Plan qualitative elevation of house lighting environment making lighting image which is coincided in our real condition, and is thought to reflect various resident's character, fondness in design and solved dissatis faction.

  • PDF

Pedestrian wind conditions at outdoor platforms in a high-rise apartment building: generic sub-configuration validation, wind comfort assessment and uncertainty issues

  • Blocken, B.;Carmeliet, J.
    • Wind and Structures
    • /
    • 제11권1호
    • /
    • pp.51-70
    • /
    • 2008
  • CFD is applied to evaluate pedestrian wind comfort at outdoor platforms in a high-rise apartment building. Model validation is focused on generic building sub-configurations that are obtained by decomposition of the actual complex building geometry. The comfort study is performed during the design stage, which allows structural design changes to be made for wind comfort improvement. Preliminary simulations are performed to determine the effect of different design modifications. A full wind comfort assessment study is conducted for the final design. Structural remedial measures for this building, aimed at reducing pressure short-circuiting, appear to be successful in bringing the discomfort probability estimates down to acceptable levels. Finally, the importance of one of the main sources of uncertainty in this type of wind comfort studies is illustrated. It is shown that the uncertainty about the terrain roughness classification can strongly influence the outcome of wind comfort studies and can lead to wrong decisions. This problem is present to the same extent in both wind tunnel and CFD wind comfort studies when applying the same particular procedure for terrain relation contributions as used in this paper.

공동주택의 열사용량원단위 산정에 관한 연구 (A Study on the Calculation of Thermal Consumption Unit of Apartment)

  • 이왕제;강은철;이의준;신우철
    • 설비공학논문집
    • /
    • 제26권8호
    • /
    • pp.388-393
    • /
    • 2014
  • Energy consumption unit in a building is classified according to uses of electricity, gas, and oil, and it has been studied steadily as a material for establishing policy standards for energy saving in buildings. Meanwhile, consumption unit in apartment house can be calculated differently according to its survey method and area standard. Therefore, with the necessity of reestablishing energy consumption unit, this study has researched thermal energy consumption, Supply dwelling area Exclusive dwelling area, completion year and housing type of 23,791 households of 31 complex in Daejeon. As a result, (1) there was about 20% difference between supply and exclusive dwelling areas. (2) On the basis of exclusive dwelling area, thermal energy consumption unit was calculated as $104.9kWh/m^2{\cdot}a$ in 2010, $104.6kWh/m^2{\cdot}a$ in 2011, and $107.7kWh/m^2{\cdot}a$ in 2012.

아파트 자전거 주차장 이용실태에 관한 조사 연구 - 광주광역시 자전거 주차장 설치 아파트를 대상으로 - (A Study on the Current Status of the Use of Bike Parking Lots in Apartments - For the Apartments with Bike Parking Lots in Gwangju Metropolitan City -)

  • 김윤학;박성진
    • 한국농촌건축학회논문집
    • /
    • 제21권2호
    • /
    • pp.43-51
    • /
    • 2019
  • The purpose of this study was to examine the current status of the use of bike parking lots in apartment complexes located in Gwangju Metropolitan City. The results were as follows. While common respondents answered the use of a bike for leisure or health, relatively few respondents answered a means of transportation such as going to school or work. It suggests that systematic plans to expand the range of using a bike should be made such as the connection of an apartment complex with a bike road. The common places to keep bikes were the entrance, the inside of the house, or stairs rather than bike parking lots because of safety problems such as theft or damage. In this regard, it is necessary to prepare clear regulation guidances to complement the safety problems of bike parking lots such as CCTV installation in the parking lots or compulsory installation of night lighting. Based on the findings, the methods to improve a bike parking lot should consider safety solutions and the complement of locations or keeping types. To activate the use of a bike, it is necessary to improve facilities to help residents' use of bike parking lots and expand their size in the future and examine the design of bike racks.

제3종 분말소화기의 내용연수에 따른 소화약제의 미세도 실험 (The A Test of Physical Property of Fire Extinguishing Agent according to Durable Years of the Third-class Powder Extinguisher)

  • 손주달;공하성
    • 대한안전경영과학회지
    • /
    • 제24권4호
    • /
    • pp.117-124
    • /
    • 2022
  • This study collected powder extinguishers with 6-10 years of elapsed life from January 2012 to January 2017 in market, factory, and apartment areas to experiment with changes in fineness and to examine the characteristics of extinguishing power. First, in the case of ABC powder, 98.3 wt% of the 8-year market area and 98.6 wt% of the 10-year apartment complex were found to be inappropriate in the first, second, and third arithmetic average analysis of the powder extinguisher from 6 to 10 years. That is, the fine distribution and size of the powder extinguishing agent particles should be managed within an appropriate range. It is analyzed that the powder fire extinguisher may experience a change in the fineness of the powder depending on the external environment exposure, placement, management status, and age of use, resulting in a decrease in digestive power or inability to radiate. Second, the fire extinguisher cannot be used in the initial fire suppression depending on the place of deployment, the environment of deployment, the progress of the number of years of use, and maintenance, so it is necessary to strengthen the device that enables fire extinguisher maintenance and inspection. Third, in the manufacturing process, the charging method should also be reviewed in consideration of the conditions of the workplace, the humid season, and the rainy environment.

POST-OCCUPANCY EVALUATION (POE) AFTER THE EXPANSION OF AN APARTMENT PARKING LOT

  • Park, Jin-Gu;Oh, Kyung-Taek;Ryu, Gyu-Seok;Jung, In-Su;Lee, Chan-Sik
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1559-1563
    • /
    • 2009
  • Despite the serious lack of parking lots, studies on parking lot expansion are insufficient; research on users' satisfaction following parking lot expansion is practically nonexistent. Therefore, this study sought to provide basic data for the parking lot expansion of old apartments by comparatively analyzing users' satisfaction before and after the parking lot expansion through a questionnaire survey that targeted residents benefiting from the expanded parking lot. Results revealed a low post-occupancy satisfaction with the parking lot expansion despite the parking lot expansion and improvement of the parking lot environment. This was because the parking lot was not expanded up to the second basement floor due to the lack of appropriate parking space. Other factors included the construction cost burden and lack of connectivity of the basement parking lot with elevators. The results actually raise the need for the establishment of an optimally suitable expansion plan and development of method and technology requiring lower cost and shorter construction period in the design and construction processes for parking lot expansion. Through post-occupancy evaluation (POE) after parking lot expansion, this study quantitatively identified the problems associated with the parking lots of old apartments and ensuing expansion effects. The findings in this study can be used as basic data to seek a suitable diagnosis and evaluation method for the parking lots of old apartments.

  • PDF

공동주택 방화문의 내구성능 및 내용연수 제안에 관한 연구 (A Study on the Proposal of Durability and Service Life of Fire Door in apartment house)

  • 권영진;김윤성;진승현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.49-50
    • /
    • 2022
  • There are continuous cases of fire expansion due to fire door problems around the world, including the 2010 Shanghai Apartment Fire, the 2017 Grenfell Tower Fire in England, and the 2020 Ul-san Residential and Commercial Complex Fire. In order to prevent such fire damage, the country has strengthened the performance standards of fire doors, and recently, efforts have been made to ensure the best performance of fire doors by introducing a quality recognition system. Securing the performance of fire doors is a very important aspect. However, there is a concern that old fire doors may not function normally in the event of fire due to natural deterioration, corrosion, and damage during the use process, but countermeasures are insufficient. Therefore, from a management perspective, it is very important to maintain fire doors and secure an appropriate replacement time. Therefore, the purpose of this study is to determine whether the fire door has durability to prevent fire spread in the process of use through operation probability analysis and expert surveys, and to propose an appropriate useful life of the fire door.

  • PDF

공동주택 단지 내 주민공동시설의 소음 방지를 위한 공기전달음 차단 성능 현장 조사 (Field Measurement of Airborne Sound Insulation for Noise Reduction about Community Facilities in an Apartment Complex )

  • 성요한;김진식;김혜원;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.249-250
    • /
    • 2023
  • The objective of this study is to evaluate the airborne sound insulation performance between housing units and community facilities during the construction phase. Community facilities adjacent to housing units can lead to noise problems, hence it is necessary to minimize noise transmission during the design phase. However, flanking noise transmitted through gaps of structures, windows, pipes, and other openings may result in substandard sound insulation performance falling below the design standards. Therefore, It is crucial to measure airborne sound insulation in the field during the construction phase. The measurement was conducted using the survey method for the field measurement of the airborne sound insulation in accordance with KS F ISO 10052:2021. Although the noise standards caused by community facilities in apartment complexes are not specified in current laws and regulations, desired noise level was set based on international guidelines for indoor noise. First, the level of noise generated in community facilities was estimated, and then the sound insulation performance was evaluated to determine whether the desired noise level was achieved.

  • PDF

경기도 공동주택단지 내 작은도서관 활성화를 위한 정책 제안 연구 (A Study on the Policy Proposal for the Revitalization of Small Libraries in the Residential Communities in Gyeonggi-do)

  • 노영희;최만호;김윤정;장로사
    • 한국문헌정보학회지
    • /
    • 제54권3호
    • /
    • pp.71-95
    • /
    • 2020
  • 국내 작은도서관이 가장 많이 소재하고 있는 경기도에는 공동주택단지 내 작은도서관의 비율이 42%에 이르고 있으나, 법적 의무에 의해 설립된 도서관들이 자발적 의지에 의존하여 관리·운영됨에 따라 휴관·폐관되는 사례가 지속적으로 발생하고 있다. 공동주택단지 내 작은도서관의 활성화를 위해서는 단지 내 마을 공동체의 구심점 역할을 통해 활성화의 방안을 모색하는 것이 타당하다. 이를 위해 본 연구에서는 경기도 작은도서관의 현황 조사, 경기도 및 31개 시군의 공동주택단지 내 작은도서관 운영자 및 관계자 대상의 설문조사와 심층인터뷰를 실시하였으며, 이를 기반으로 공동주택단지내 작은도서관 운영의 실제적인 활성화 방안을 도출하고자 하였다. 작은도서관에 대한 공동체 인식 개선, 자체 운영 능력 배양, 법·제도 개선, 지자체의 지원 강화의 4가지 목표를 설정하여 실천방안을 도출하였다. 사회의 변화에 따른 경기도 공동주택단지 내 작은도서관 뿐 아니라 타 사립작은도서관의 지속적인 발전을 위한 연구도 수행될 필요가 있다.