• Title/Summary/Keyword: angular position

Search Result 445, Processing Time 0.022 seconds

The Comparison of Trunk Repositioning Errors in Individuals with and without Low Back Pain at Different Postures (요통 환자와 정상인의 자세에 따른 체간 위치 오류 비교)

  • Yuk, Goon-Chang;Han, Jin-Tae;Shin, Hyun-Suk;Lee, Ho-Geon;Park, Rea-Joon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.2
    • /
    • pp.63-74
    • /
    • 2008
  • Purpose : The purpose of this study was to compare trunk repositioning errors between subjects with and without low back pain in sitting and standing. Methods : Total 81 participants were recruited who consisted of 41 subjects with low back pain and 40 normal subjects. The subjects were instructed to replicate the predetermined target positions of the trunk toward upright and $30^{\circ}$ flexion in sitting and standing. During each of movement, digital inclinometer was used to measure the angular movement of $T_{12}$ spinal process. Repositioning error was calculated as the absolute difference between the predetermined target positions and replicated target positions. Results : In subjects with low back pain, upright repositioning error was $1.26^{\circ}{\pm}0.14^{\circ}$ in sitting and $1.55^{\circ}{\pm}0.24^{\circ}$ in standing, and $30^{\circ}$ flexion repositioning error was $3.23^{\circ}{\pm}0.33^{\circ}$ in sitting and $5.50^{\circ}{\pm}0.50^{\circ}$ in standing. In subjects without low back pain, upright repositioning error was $1.38^{\circ}{\pm}0.15^{\circ}$ in sitting and $1.67^{\circ}{\pm}0.18^{\circ}$ in standing, and flexion repositioning error was $2.61^{\circ}{\pm}0.28^{\circ}$ in sitting and $3.70^{\circ}{\pm}0.52^{\circ}$ in standing. It was demonstrated that flexion repositioning error increased significantly in standing position. In subjects with low back pain, $30^{\circ}$ flexion repositioning error was significantly higher in standing than in sitting. Conclusion : The repositioning error of subjects with low back pain increased during flexion and it implies that some aspects of proprioception are decreased in subjects with low back pain. Therefore, it will be emphasis that a clinical trial to increase the trunk flexion stability of subjects with low back pain in standing.

  • PDF

Kinematical Analysis of Lopez Motion in Horse Vault: Comparison between Successful and Failed Trials (도마 Lopez 동작의 운동학적 분석: YHS 선수의 성공과 실패 사례 비교)

  • Park, Cheol-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.167-174
    • /
    • 2020
  • The purpose of this study was to investigate the kinematic comparison between successful and failed trials of Lopez vault techniques in male gymnastics. The subject, an Olympic gold medalist, was YHS (age: 27 years, height: 1.6 m, and mass: 53 kg) and fourteen high speed motion capturing cameras were used for data collection. The 26 reflective sensors were attached on major anatomical positions and 15 segment-body model was used to calculate the kinematic variables. According to results, the contact duration of the spring-board for successful trial(ST) was longer and that of failed trial(FT) and the range of motion of knee joint for ST was greater than that of FT. The movement times during pre-flight between ST and FT were same, but the movement time of horse contact period for ST was shorter than that of FT. The ST showed a longer movement time during post-flight and the longer horizontal distance than those of FT. Conclusively, YHS needs to approach the horse with a higher position of the body and higher incidence angle, as well as make faster twist angular velocity in an attempt to achieve ST.

Model on the Contact Lens Movement from Eye-lid Blinking (순목 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.145-159
    • /
    • 2004
  • A mathematical model and its computer solution program were proposed to analyze the motion of contact lenses which are being subject to lid-blinking. The equation was derived by incorporating an acceleration induced lid's force exerting on the contact lens, the viscous damping resistance in the tear layer beneath the lens and the sliding frictional force between the lid and the contact lens surface into the formulation of differential equation describing the vibration. The model predicts the time-dependent displacement from the equilibrium postion during/after the blinking. During the blinking, as the time for the completion of one cycle of blinking decreases the off-the-equilibrium displacement of contact lens increases while the decrease of diameter in the contact cause the opposite effect. It is found that lid pressure exerting on the lens cause an insignificant lens displacement from the equilibrium position. After blinking the frequency of damped oscillation of contact lens decreases as the diameter of lens increases, due to the incresed surface while the reduced blinking time does not cause a significant frequency change. This is because that driving force for the contact lens movement posterior to blinking is the capillary-induced force not the lid force.

  • PDF

Color Restoration Method Using the Dichromatic Reflection Model for Low-light-level Environments (저조도 환경에 적합한 이색도 반사 모델을 이용한 색 복원 기법)

  • Lee, Woo-Ram;Jun, WooKyoung;Jun, Byoung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7324-7330
    • /
    • 2014
  • Color distortion of the dark images acquired under a low-light-level environment with a weak light source can be cause of the performance decreation of various vision systems. Therefore, recovering the original color of the images is an important process for enhancing the performance of the system. For this, this study proposes a color restoration method using a dichromatic reflection model. This paper assumes that the dark images can be classified into two parts affected by specular or diffuse reflection. Two different color constancy methods were then applied to the images to remove the effects of each reflection and two images were created as a result. The resulting images produced a one color-corrected image by combining with different weights according to the position in the images. For the performance evaluation, this paper used a synthesized image, and considered the Euclidean distance and angular error as an evaluation factor. In addition, a performance comparison was performed with the existing various color constancy method to achieve the objectivity of evaluation. The experimental results showed that the proposed method can be a more suitable solution for color restoration than the existing method.

Prediction of the Acoustic Performance of a Music Hall Considering the Radiation Characteristics of Korean Traditional Musical Sources (국악음원의 방사특성을 고려한 국악원의 음향 성능 예측)

  • 정철호;이정권;연철호;한찬훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.146-161
    • /
    • 2004
  • There have been always some difficulties in target setting and conditioning of acoustic performances of the Korean traditional music hall due mainly to the lack of the information on the sound radiation characteristics of Korean musical sources. In this study, the radiation characteristics of four typical Korean traditional musical sources were investigated in precision and their usage was demonstrated: The selected musical sources were Gayageum (string), Daegeum (woodwind), Jango (drum), and Pansori Chang (vocal performance). Each sound source was located at the center of a semi-anechoic chamber and the directivity was determined by the measured sound pressure levels in every 10° angular position, for both vertical and horizontal directions. The directivity pattern of Gayageum varies from a uniform to a complex pattern having many side lobes with the increase of frequency. The main radiation of Daegeum is toward the upward direction. The directivity pattern of Jango is clearly a side-oriented one and the left direction intensity is sharper than its right side at low frequencies. For the Chang, the directivity pattern change from a uniform pattern to a frontally directed one as the frequency goes high. Measured directional and spectral characteristics of traditional Korean music sources were implemented into the computation of architectural acoustic measures for the Busan National Korean Traditional Music Hall which is under construction. Parameters such as RT, SPL, C80, IE, STI were calculated at two receiver positions by using a ray tracing technique. Significant differences in the acoustic measures at receiver positions were observed between the results in using the omni-directional source and the directional one. It is thought that the suggested source data and design method can be used as a basic reference in the future acoustic design of performance halls for the Korean traditional music.

COMPARATIVE STUDY ON THE HORIZOTAL MEASUREMENTS OF SKELETAL CLASS III MALOCCLUSION USING THE ROC ANALYSIS (ROC 분석을 이용한 골격성 III급 부정교합의 수평계측방법간 비교연구)

  • Choi, Hee-Young;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.153-163
    • /
    • 1995
  • In this study, Receiver Operating Characteristic(ROC) analysis was used to evaluate the ability of cephalometric measurements to identify patients with Class III malocclusions. ROC analysis is the method for determining the validity of a diagnostic measure and for evaluating the relative value of diagnostic tests. The sample consisted of 496 patients with malocclusion. Class III malocclusion is defined as the dental relationship for which The mesiobuccal groove of the lower first molar is deviated mesially from the mesiobuccal cusp of the upper first molar. Of the total sample of 496 patients, 245 had Class III malocclusions. 16 cephalometric measurements were selected, each of which was treated as a diagnostic test. The ROC curves were generated for each cephalometric measurement with intervals of $1.0^{\circ}$ for angular measurements, 1.0mm for linear measurements. The area under the ROC curves was measured for direct comparison among different diagnostic tests. The results were as follows; 1. The 'Wits' appraisal was found to be a better diagnostic criterion for the presence of Class III malocclusion than any other commonly'used cephalometric measurement. 2. AB plane angle, ANB angle, App-Bpp distance, AF-BF distance, APDI, Distance of point A and Pog to N perpendicular, maxillomandibular differential had high diagnostic value. 3. Cephalometric measurements which evaluate the position of the mandible had moderate diagnostic value. 4. Cephalometric measurements related to the maxilla discriminated least between patients with and without Class III malocclusion.

  • PDF

Development of Integrated Process Management System for Pump Dredge (펌프식 준설선의 통합공정관리시스템 개발)

  • Jeong, Dae-Deuk;Lee, Joong-Woo;Cho, Jeung-Eon
    • Journal of Navigation and Port Research
    • /
    • v.26 no.1
    • /
    • pp.146-151
    • /
    • 2002
  • Efficiency of dredging work depends on the types of equipment used, the sediments encountered, whether the work to be performed is new or for maintenance, pre and/or post hydrographic surveying and so forth. Among those, surveying accuracy which is directly determined by the control of the dredge's position and depth surveying accuracy being surveyed at the dredging point are important factors. The purpose of this study is to develop an integrated process management system for pump dredge. The system is composed of 4 sub-systems such as LADGPS for dredge positioning dredging point determination, tidal gauge and angular depth sensor for depth determination, and GIS and ENC process management. The process management system for pump dredge developed was installed on the pump dredge "EUNJIN PD-2" but is now producing work data for comparison with performance of the existing dredge. The data retrieved from the pump dredge process management system up to now shows similar result from the grab dredge management system which was developed previously. It is easy to operate, achieves good accuracy with only 45cm unevenness, reduces working perioa by 20 percint,. More precise evaluation of the system comes later after the dredging work is completed.completed.

Systematic Error Correction in Dual-Rotating Quarter-Wave Plate Ellipsometry using Overestimated Optimization Method (최적화 기법을 이용한 두 개의 회전하는 사분파장판으로 구성된 타원편광분석기에서의 체계적인 오차 보정)

  • Kim, Dukhyeon;Cheong, Hai Du;Kim, Bongjin
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.29-37
    • /
    • 2014
  • We have studied and demonstrated general, systematic error-correction methods for a dual rotating quarter-wave plate ellipsometer. To estimate and correct 5 systematic error sources (three offset angles and two unexpected retarder phase delays), we used 11 of the 25 Fourier components of the ellipsometry signal obtained in the absence of an optical sample. Using these 11 Fourier components, we can determine the errors from the 5 sources with nonlinear optimization methods. We found systematic errors ${\epsilon}_3$, ${\epsilon}_4$, ${\epsilon}_5$) are more sensitive to the inverted Mueller matrix than retarder phase delay errors (${\epsilon}_1$, ${\epsilon}_2$) because of their small condition numbers. To correct these systematic errors we have found that error of any variety must be less than 0.05 rad. Finally, we can use the magnitudes of these errors to correct the Mueller matrix of optical components. From our experimental ellipsometry signals, we can measure phase delay and the rotational angular position of its fast axis for a half-wave plate.

ESR Study of Paramagnetic Defects of the ${\gamma}$-irradiated Potassium Sulfate Single Crystal (${\gamma}$-선에 조사된 황산칼륨 단결정의 상자성 결함에 관한 전자스핀공명 연구)

  • Yo Chul Hyun;Chung Won Yang;Jong In Hong;Eun Ok Kim;Jung Sung Yang
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.367-375
    • /
    • 1981
  • Single crystals of Potassium Sulfate ($K_2SO_4$) have been grown from the saturated solution by the evaporation method at the optimum conditions. Radiation damages in the crystal by ${\gamma}$-irradiation of about $12{\times}10^6$ Roentgen have given rise to paramagnetic centers or paramagnetic defects. Electron spin resonance (ESR) spectra of the centers are obtained with the X-band EPR spectrometer at room temperature. The ESR peaks of the paramagnetic species are found to be anisotropic but the peak of $SO_3-$ radical is an isotropic of Gaussian shape at g = 2.0036. A number of ESR spectra of the crystal for angular variation of the anisotropic peaks are recorded at various orientations of rotation about a, b and c crystallographic axes respectively. The g-values are calculated from the line position between anisotropic peaks and the isotropic one and then principal g-values and its direction cosines of the species are obtained by diagonalization of 9 matrix elements of the corresponding g-values. All the paramagnetic defects are identified by the characteristic principal g-values and its direction cosines.

  • PDF

A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve

  • Bu Kwang Oh;Dong Wuk Son;Jun Seok Lee;Su Hun Lee;Young Ha Kim;Soon Ki Sung;Sang Weon Lee;Geun Sung Song;Seong Yi
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.60-72
    • /
    • 2024
  • Objective : Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF. Methods : This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation. Results : The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend. Conclusion : In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.