References
- Ahern DP, Gibbons D, Schroeder GD, Vaccaro AR, Butler JS : Imageguidance, robotics, and the future of spine surgery. Clin Spine Surg 33 : 179-184, 2020 https://doi.org/10.1097/BSD.0000000000000809
- Attar A, Ugur HC, Uz A, Tekdemir I, Egemen N, Genc Y : Lumbar pedicle: surgical anatomic evaluation and relationships. Eur Spine J 10 : 10-15, 2001 https://doi.org/10.1007/s005860000198
- Avrumova F, Morse KW, Heath M, Widmann RF, Lebl DR : Evaluation of K-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: learning curve and technical notes. J Spine Surg 7 : 141-154, 2021 https://doi.org/10.21037/jss-20-687
- Broadbent E, Kuo IH, Lee YI, Rabindran J, Kerse N, Stafford R, et al. : Attitudes and reactions to a healthcare robot. Telemed J E Health 16 : 608-613, 2010 https://doi.org/10.1089/tmj.2009.0171
- Bydon M, Chen SG, Neal MD, Krishna C, Biedermann AJ, Paul TC, et al. : Initiation of a robotic program in spinal surgery: experience at a threesite medical center. Mayo Clin Proc 96 : 1193-1202, 2021 https://doi.org/10.1016/j.mayocp.2020.07.034
- Castro E Melo JAGME, Faria Araujo NM : Impact of the fourth industrial revolution on the health sector: a qualitative study. Healthc Inform Res 26 : 328-334, 2020 https://doi.org/10.4258/hir.2020.26.4.328
- Cook SD, Salkeld SL, Whitecloud TS 3rd, Barbera J : Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J Spinal Disord 13 : 230-236, 2000 https://doi.org/10.1097/00002517-200006000-00006
- D'Souza M, Gendreau J, Feng A, Kim LH, Ho AL, Veeravagu A : Roboticassisted spine surgery: history, efficacy, cost, and future trends. Robot Surg 6 : 9-23, 2019 https://doi.org/10.2147/RSRR.S190720
- Fan Y, Peng Du J, Liu JJ, Zhang JN, Liu SC, Hao DJ : Radiological and clinical differences among three assisted technologies in pedicle screw fixation of adult degenerative scoliosis. Sci Rep 8 : 890, 2018 https://doi.org/10.1038/s41598-017-19054-7
- Gao S, Lv Z, Fang H : Robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis of randomized controlled trials. Eur Spine J 27 : 921-930, 2018 https://doi.org/10.1007/s00586-017-5333-y
- Gosrisirikul C, Don Chang K, Raheem AA, Rha KH : New era of robotic surgical systems. Asian J Endosc Surg 11 : 291-299, 2018 https://doi.org/10.1111/ases.12660
- Ho C, Tsakonas E, Tran K, Cimon K, Severn M, Mierzwinski-Urban M, et al. : Robot-assisted surgery compared with open surgery and laparoscopic surgery. CADTH Technol Overv 2 : e2203, 2012
- Hu X, Lieberman IH : What is the learning curve for robotic-assisted pedicle screw placement in spine surgery? Clin Orthop Relat Res 472 : 1839-1844, 2014 https://doi.org/10.1007/s11999-013-3291-1
- Huang M, Tetreault TA, Vaishnav A, York PJ, Staub BN : The current state of navigation in robotic spine surgery. Ann Transl Med 9 : 86, 2021 https://doi.org/10.21037/atm-2020-ioi-07
- Jiang B, Pennington Z, Azad T, Liu A, Ahmed AK, Zygourakis CC, et al. : Robot-assisted versus freehand instrumentation in short-segment lumbar fusion: experience with real-time image-guided spinal robot. World Neurosurg 136 : e635-e645, 2020 https://doi.org/10.1016/j.wneu.2020.01.119
- Khan A, Meyers JE, Siasios I, Pollina J : Next-generation robotic spine surgery: first report on feasibility, safety, and learning curve. Oper Neurosurg (Hagerstown) 17 : 61-69, 2019 https://doi.org/10.1093/ons/opy280
- Kim HJ, Lee SH, Chang BS, Lee CK, Lim TO, Hoo LP, et al. : Monitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test. Spine (Phila Pa 1976) 40 : 87- 94, 2015 https://doi.org/10.1097/BRS.0000000000000680
- Kuo LJ, Lin YK, Chang CC, Tai CJ, Chiou JF, Chang YJ : Clinical outcomes of robot-assisted intersphincteric resection for low rectal cancer: comparison with conventional laparoscopy and multifactorial analysis of the learning curve for robotic surgery. Int J Colorectal Dis 29 : 555-562, 2014 https://doi.org/10.1007/s00384-014-1841-y
- Laudato PA, Pierzchala K, Schizas C : Pedicle screw insertion accuracy using O-arm, robotic guidance, or freehand technique: a comparative study. Spine (Phila Pa 1976) 43 : E373-E378, 2018 https://doi.org/10.1097/BRS.0000000000002449
- Li HM, Zhang RJ, Shen CL : Accuracy of pedicle screw placement and clinical outcomes of robot-assisted technique versus conventional freehand technique in spine surgery from nine randomized controlled trials: a meta-analysis. Spine (Phila Pa 1976) 45 : E111-E119, 2020 https://doi.org/10.1097/BRS.0000000000003193
- Lieberman IH, Kisinde S, Hesselbacher S : Robotic-assisted pedicle screw placement during spine surgery. JBJS Essent Surg Tech 10 : e0020, 2020 https://doi.org/10.2106/JBJS.ST.19.00020
- Lien SB, Liou NH, Wu SS : Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine. Eur Spine J 16 : 1215-1222, 2007 https://doi.org/10.1007/s00586-006-0245-2
- Lopez IB, Benzakour A, Mavrogenis A, Benzakour T, Ahmad A, Lemee JM : Robotics in spine surgery: systematic review of literature. Int Orthop 47 : 447-456, 2023 https://doi.org/10.1007/s00264-022-05508-9
- Lynn G, Mukherjee DP, Kruse RN, Sadasivan KK, Albright JA : Mechanical stability of thoracolumbar pedicle screw fixation: the effect of crosslinks. Spine 25 : 31S-35S, 2000 https://doi.org/10.1097/00007632-200003151-00005
- Mahomed S : Healthcare, artificial intelligence and the Fourth Industrial Revolution: ethical, social and legal considerations. S Afr J Bioeth Law 11 : 93-95, 2018 https://doi.org/10.7196/SAJBL.2018.v11i2.664
- Peng YN, Tsai LC, Hsu HC, Kao CH : Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials. Ann Transl Med 8 : 824, 2020 https://doi.org/10.21037/atm-20-1106
- Pennington Z, Judy BF, Zakaria HM, Lakomkin N, Mikula AL, Elder BD, et al. : Learning curves in robot-assisted spine surgery: a systematic review and proposal of application to residency curricula. Neurosurg Focus 52 : E3, 2022
- Ringel F, Stuer C, Reinke A, Preuss A, Behr M, Auer F, et al. : Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation. Spine (Phila Pa 1976) 37 : E496-E501, 2012 https://doi.org/10.1097/BRS.0b013e31824b7767
- Schatlo B, Martinez R, Alaid A, von Eckardstein K, Akhavan-Sigari R, Hahn A, et al. : Unskilled unawareness and the learning curve in robotic spine surgery. Acta Neurochir (Wien) 157 : 1819-1823; discussion 1823, 2015 https://doi.org/10.1007/s00701-015-2535-0
- Shin MH, Ryu KS, Park CK : Accuracy and safety in pedicle screw placement in the thoracic and lumbar spines : comparison study between conventional C-arm fluoroscopy and navigation coupled with O-arm® guided methods. J Korean Neurosurg Soc 52 : 204-209, 2012 https://doi.org/10.3340/jkns.2012.52.3.204
- Siddiqui MI, Wallace DJ, Salazar LM, Vardiman AB : Robot-assisted pedicle screw placement: learning curve experience. World Neurosurg 130 : e417-e422, 2019 https://doi.org/10.1016/j.wneu.2019.06.107
- Tiwari A, Pandey S, Naik DC : A study of height and width of typical lumbar pedicles in relation to mechanical load. Int J Med Sci Public Health 4 : 275, 2015 https://doi.org/10.5455/ijmsph.2015.0410201450
- Toossi N, Vardiman AB, Benech CA, Kanaly CW, Maltenfort MG, Backes DM, et al. : Factors affecting the accuracy of pedicle screw placement in robot-assisted surgery: a multicenter study. Spine (Phila Pa 1976) 47 : 1613-1619, 2022 https://doi.org/10.1097/BRS.0000000000004473
- Vardiman AB, Wallace DJ, Crawford NR, Riggleman JR, Ahrendtsen LA, Ledonio CG : Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery. J Robot Surg 14 : 409- 413, 2020 https://doi.org/10.1007/s11701-019-00994-3
- Vo CD, Jiang B, Azad TD, Crawford NR, Bydon A, Theodore N : Robotic spine surgery: current state in minimally invasive surgery. Global Spine J 10(2 Suppl) : 34S-40S, 2020 https://doi.org/10.1177/2192568219878131
- Yi M, Song J, Zhang Y, Lin W, Yao M, Fan Y, et al. : Risk factor analysis of the accuracy and safety of planned and actual screw paths with robot-assisted technology. Available at : https://doi. org/10.21203/rs.3.rs-2220116/v1
- Zhang JN, Fan Y, Hao DJ : Risk factors for robot-assisted spinal pedicle screw malposition. Sci Rep 9 : 3025, 2019 https://doi.org/10.1038/s41598-019-40057-z