• Title/Summary/Keyword: angled

Search Result 298, Processing Time 0.028 seconds

Studies on Erythrocyte Sedimentation Rate Test by Angled Tube Method in Cattle Diseass (우질병에 있어서 경사시험관법에 의한 적혈구침항율에 관한 연구)

  • Shin Jong-uk
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.579-583
    • /
    • 1994
  • In the present studies, samples of blood were taken from 24 Holstein cattle over 2 years old. By using the angled tube method the normal ESR values were determined in cattle under various diseases. The results obtained were summarized as follows ; The standardized ESR/hr using 45$^{\circ}$ angled capillary tubes were 19.0% in case of necrotic mastitis, 23.0% in nephritis, 12.2% in anemia and 4.2% in diarrhea. And the ESR was increased from some necrotic disease, decreased from diarrhea conditions and general the normal ESRs were shown in the sub-clinical or recovery stage of infections or disorders.

  • PDF

Positive and negative predictive values by the TOC curve

  • Hong, Chong Sun;Choi, So Yeon
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.2
    • /
    • pp.211-224
    • /
    • 2020
  • Sensitivity and specificity are popular measures described by the receiver operating characteristic (ROC) curve. There are also two other measures such as the positive predictive value (PPV) and negative predictive value (NPV); however, the PPV and NPV cannot be represented by the ROC curve. Based on the total operating characteristic (TOC) curve suggested by Pontius and Si (International Journal of Geographical Information Science, 97, 570-583, 2014), explanatory methods are proposed to geometrically describe the PPV and NPV by the TOC curve. It is found that the PPV can be regarded as the slope of the right-angled triangle connecting the origin to a certain point on the TOC curve, while 1 - NPV can be represented as the slope of the right-angled triangle connecting a certain point to the top right corner of the TOC curve. When the neutral zone exists, the PPV and 1-NPV can be described as the slopes of two other right-angled triangles of the TOC curve. Therefore, both the PPV and NPV can be estimated using the TOC curve, whether or not the neutral zone is present.

IDEAL RIGHT-ANGLED PENTAGONS IN HYPERBOLIC 4-SPACE

  • Kim, Youngju;Tan, Ser Peow
    • Journal of the Korean Mathematical Society
    • /
    • v.56 no.4
    • /
    • pp.1131-1158
    • /
    • 2019
  • An ideal right-angled pentagon in hyperbolic 4-space ${\mathbb{H}}^4$ is a sequence of oriented geodesics ($L_1,{\ldots},L_5$) such that $L_i$ intersects $L_{i+1},i=1,{\ldots},4$, perpendicularly in ${\mathbb{H}}^4$ and the initial point of $L_1$ coincides with the endpoint of $L_5$ in the boundary at infinity ${\partial}{\mathbb{H}}^4$. We study the geometry of such pentagons and the various possible augmentations and prove identities for the associated quaternion half side lengths as well as other geometrically defined invariants of the configurations. As applications we look at two-generator groups ${\langle}A,B{\rangle}$ of isometries acting on hyperbolic 4-space such that A is parabolic, while B and AB are loxodromic.

IDEAL RIGHT-ANGLED PENTAGONS IN HYPERBOLIC 4-SPACE

  • Kim, Youngju;Tan, Ser Peow
    • Journal of the Korean Mathematical Society
    • /
    • v.56 no.3
    • /
    • pp.595-622
    • /
    • 2019
  • An ideal right-angled pentagon in hyperbolic 4-space ${\mathbb{H}}^4$ is a sequence of oriented geodesics ($L_1,{\ldots},L_5$) such that Li intersects $L_{i+1},\;i=1,\;{\ldots},\;4$, perpendicularly in ${\mathbb{H}}^4$ and the initial point of $L_1$ coincides with the endpoint of $L_5$ in the boundary at infinity ${\partial}{\mathbb{H}}^4$. We study the geometry of such pentagons and the various possible augmentations and prove identities for the associated quaternion half side lengths as well as other geometrically defined invariants of the configurations. As applications we look at two-generator groups ${\langle}A,B{\rangle}$ of isometries acting on hyperbolic 4-space such that A is parabolic, while B and AB are loxodromic.

Response of angled two-strip transmission lines to the incdent angle of an external electromagnetic field, I : Circuit-concept analysis (외부 전자파의 입사방향에 대한 각진 두 스트립으로 구성된 전송선의 반응, I:회로개념의 해석)

  • 홍성용;김세윤;라정웅
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.3 no.2
    • /
    • pp.3-9
    • /
    • 1992
  • The reponse of the angled two-strip transmission lines illuminated by an external electromagnetic field is estimated by using the circuit concept approach. Calculated terminal voltages reveal convergence to a fixed value as the number of discretization increases. The amplitude patterns of two terminal voltages to all the direction and polarization of the incident field are also calculated.

  • PDF

On the Limitation of Telegrapher′s Equations for Analysis of Nonuniform Transmission Lines

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.68-71
    • /
    • 2004
  • The limitation of telegrapher's equations for analysis of nonuniform transmission lines is investigated here. It is shown theoretically that the input impedance of a nonuniform transmission line cannot be derived uniquely from the Riccati equation only except for the exponential transmission line of a particular frequency-dependent taper. As an example, the input impedance of an angled two-plate transmission line is calculated by solving the telegrapher's equations numerically. The numerical results suffer from larger deviation from its rigorous solution as the plate angle increases.

A Reliable Low-Loss Field-Installable Optical Connector Design by Splicing Angle Adjustment (접속 각도 조정을 통한 신뢰성 있는 저 손실 현장조립 광커넥터 설계)

  • Park, Byung-Chul;Rim, Chong-Suck;Jung, Jun-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.6-12
    • /
    • 2011
  • In this paper, we propose a design method for a reliable and improved field-installable optical connectors(FIOC) which are needed for long-distance and low loss FTTH configuration. To this end, we optimize the angle of splicing between the inner fiber and the field fiber of the FIOC, so that the low loss connection of optical fibers is possible without using any angle alignment tools as well as angled cleavers. More precisely, we set the cutting angle of the inner filber and the field fiber to be $2^{\circ}$ by using an angled cleaver and $0^{\circ}{\sim}1^{\circ}$ by using a general fiber cutter, respectively. Splicing these two optical fibers without any further adjustment, we can keep the insertion loss within 0.3dB and the reflection loss within -60dB.

A Optimal 3D FE Model for Evaluation of Peening Residual Stress Under Angled Multi-impacts (다중경사충돌시 피닝잔류응력 평가를 위한 최적의 3차원 유한요소모델)

  • Hyun, Hong-Chul;Kim, Tae-Hyung;Lee, Hyung-Yil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.125-135
    • /
    • 2012
  • The FE model for shot peening often assume that shots impact vertically on the engineering parts to generate compressive residual stresses. However, the shots obliquely impact on the surface in actual peening. In this work, we propose a 3D finite element (FE) model for evaluation of residual stress under angled shot peening. Using the FE model for angled multi-impact, we examine the effects of factors such as impact angle, impact pattern and the number of shots. Plastic deformation of shot is also considered. To validate the model, we then compare the FE solution with experimental result by X-ray diffraction (XRD). The proposed model will be a base of 3D multi-impact FE model with diverse impact angles.

Heat/Mass Transfer Augmentation in a Square Duct . Roughened with Angled Discrete Ribs Having Narrow Gaps (정사각 덕트 내에서 열/물질전달 촉진을 위한 경사진 단락 요철의 좁은 틈새 효과)

  • Wu, Seong-Je;Lee, Sei-Young;Choi, Chung;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.150-158
    • /
    • 2002
  • Local heat/mass transfer and friction loss in a square duct roughened with various types of continuous and discrete rib turbulators are investigated. The combined effects of the gap flows of the discrete ribs and the secondary flows are examined for the purpose of the reduction of thermally weak regions and the promotion of the uniformity of heat/mass transfer distributions as well as the ;augmentation of average heat/mass transfer. The rib-to-rib pitch to the rib height ratio (p/e) of 8 and the rib angles of 90° and 60° are selected with e/D$\_$h/=0.08. The vortical structure of the secondary flows induced by the parallel angled arrays are quite distinct from that induced by the cross angled arrays. This distinction influences on heat/mass transfer and friction loss in all the tested cases. The gap flows of the discrete ribs reduce the strength of the secondary flows but promote local turbulence and flow mixing. Consequently, the angled discrete ribs with the small gaps provide a more uniform heat/mass transfer distribution sustaining high average heat/mass transfer.

Evaluation of Fracture Strength and Screw Loosening of a New Angled Abutment with Angulated Screw Channel (나사 접근 구멍 각도가 조절 가능한 새로운 경사형 지대주의 파절강도 및 나사 풀림력 연구)

  • Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.623-628
    • /
    • 2023
  • The purpose of this study was to evaluate the fracture strength and removal torque value (RTV) of a conventional angled abutment and a newly developed angled abutment (Beauty up abutment) with an angulated screw access hole. Each abutment was divided into a control group and an experimental group (n = 20, respectively). To measure the fracture strength, the abutment was connected to the internal hex implant with 30 Ncm torque, and a load was applied at 30 degree angle with cross-head speed of 1 mm/min using a universal testing machine according to the ISO 14801:2016 standard. To measure RTV, each abutment was fastened to the implant with 30 Ncm torque. Retightening was performed after 10 minutes, and initial RTV was measured with a digital torque gauge. After retightening, a load of 250 N was applied to the abutment at a 30 degree angle using a chewing simulator. After a total of 100,000 repeated loads, RTV was measured. Statistical analysis was performed using Wilcoxon signed rank test and Mann-Whitney U test (α = .05). The fracture strength of the experimental group was statistically significantly lower than that of the control group (P = .009). There was no significant difference between initial RTV and post-loading RTV between the experimental group and the control group (P = .753, P = .527, respectively), and cyclic loading did not significantly affect RTV in both groups (P = .078).