• Title/Summary/Keyword: angle of shoulder

Search Result 448, Processing Time 0.023 seconds

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

Clinical Results of Lateral-Posterior Internal Fixation for the Treatment of Scapular Body Fractures (견갑골 체부 골절에서 외측 후방 금속판 고정술의 치료 결과)

  • Lee, Yoon-Min;Yeo, Joo-Dong;Song, Seok-Whan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.46-53
    • /
    • 2020
  • Purpose: Scapular body fractures have generally been treated with non-surgical methods. This study reports the clinical and radiological outcomes after lateral-posterior internal fixation for treating displaced scapular body fractures. Materials and Methods: From March 2007 to May 2017, out of 40 patients who underwent internal fixation for scapular fractures, 13 cases of lateral plate fixation of a scapular body fracture were reviewed retrospectively. Preoperative and postoperative displacement, angulation and glenopolar angle (GPA) were measured. The range of shoulder motion, visual analogue scale (VAS), and disabilities of the arm, shoulder, and hand (DASH), and Constant score were assessed at the last follow-up. Results: The mean follow-up period was 17.7 months (range, 6-45 months). The mean preoperative GPA was 23.3°±3.96° (range, 17.8°-28.1°) and the postoperative GPA was 31.1°±4.75° (range, 22.5°-40.1°). Injury to the suprascapular nerve, nonunion, fracture redisplacement, metallic failure, or infection did not occur. At the last follow-up, the mean range of motion was 150.5°±19.3° in forward flexion, 146.6°±2.34° in lateral abduction, 66.6°±19.1° in external rotation, and 61.6°±18.9° in internal rotation. The VAS, DASH, and Constant scores were 1.7±1.3, 6.2±2.4, and 86±7.9 points, respectively. Conclusion: A scapular body fracture with severe displacement, angulation and marked decreased GPA can be stabilized by lateralposterior plate fixation using the appropriate surgical technique with good functional and radiological results.

Analysis of the Kinematic Characteristics at Entrance to the Straight Course from the Curvilinear Course in the 200m-Track Game (육상 200m 경기의 곡선주로에서 직선주로 진입 시 운동학적 특성분석)

  • Oh, Sei-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.51-63
    • /
    • 2002
  • This study sought to identify the kinematic characteristics at entrance to the straight course from the curvilinear course in the 200m-track game. For this purpose, this study was conducted for 4 sprinters by setting the 10m-section combined from the curvilenear track to the straight course and shooting them with the camcorder. It was set up to include all the sections of analysis by using the framework of the control point knowing the coordinate of the space and actual analysis was conducted on the motion showing the best records by conducting it for each subject five times. As a result, the following conclusion was drawn: It was found that the subjects showed the average stride of 4.5${\pm}$0.41 times at the 10-meter section and the required time of 1.42${\pm}$0.04sec. They showed the ratio average stride to height of 1.25${\pm}$0.20% and the average speed of 7.06${\pm}$0.19m/s. The displacement in the center of gravity of the human body at the section combined from the curvilinear course to the straight course was moving along the inward course of the curvilinear course, and the displacement of the leg located at the outward direction(right) was found to be larger than that of the leg located at the inward direction(left). In the speed of the left and right hand segments, it was found that the speed of the right hand located in the outward direction was faster than that of the left hand located at the inward, and it was found that the subjects progressed in the curvilinear course. The subjects showed the larger angle of the shoulder joint when the upper arm was located in the forward direction than when the it was located in the backward direction. In the curvilinear course, they showed the lower value of the lateral angle of the trunk when the right foot located at the outward direction left the ground than when the left foot located at the inward direction left the ground. And it was found that the lateral angle of the trunk became lower with approaching the straight course.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Descriptive Study for Sonographic Morphology of the 1st Facet of Subscapularis Footprint (견갑하건 부착부의 제1부착면에 대한 초음파 소견의 기술적 연구)

  • Sohn, Hoon-Sang;Wi, Chan Kuk;Shon, Min Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.343-352
    • /
    • 2019
  • Purpose: The purpose of this study was to document the sonographic morphology of the subscapularis footprint, particularly the 1st facet, of the non-pathologic subscapularis tendon and footprint, and analyze the correlation between the size of the 1st facet and the demographic variables. Materials and Methods: Between March 2015 and December 2017, retrospectively data analysis was performed for the ultrasound (US) scans of 115 consecutive shoulder (mean age 53.4 years, range 23-74 years) with non-pathologic subscapularis tendon and footprint. The sonographic findings of the 1st facet of the subscapularis footprint was a very unique, flat, broad, and plane angle in the upward direction, which were distinguished from the other facets. On US, the transverse (medio-lateral) and longitudinal (superior-inferior) length of the 1st facet on axis of the humerus shaft were recorded. The demographic variables, including age, site, body height, weight, body mass index (BMI), and arm length, were reviewed. Results: On US, the mean transverse length of the 1st facet was 12.75 mm (range 10.54-14.50 mm, standard deviation [SD] 0.712) and the mean longitudinal length was 12.22 mm (range 9.20-13.30 mm, SD 0.888). The transverse and longitudinal length of the size of the 1st facet were significantly greater in males than in females (p<0.001, p=0.001). Of the demographic data (body height, weight, BMI, arm length) that showed a significant positive linear correlation, the correlation with body height (transverse r=0.749, p<0.001; longitudinal r=0.642, p<0.001) showed the strongest relationship, and the correlation with the BMI was weakly related. The relationships between the size of the 1st facet to site/age were not statistically significant or appeared to have no linear correlation. Conclusion: The structural and morphologic features of the 1st facet of the subscapularis footprint on the US were identified. This will provide anatomic knowledge of an US examination for subscapularis tendon pathology.

An Analysis on Retro Jacket Designs of Haute Couture Designers for the Development of High-Value Added Fashion Products (고부가가치 패션제품개발을 위한 오뜨꾸뛰르 디자이너 복고적 재킷디자인 분석)

  • Kim, Eonjeong;Yoo, Youngsun
    • Journal of the Korean Society of Costume
    • /
    • v.64 no.3
    • /
    • pp.77-92
    • /
    • 2014
  • The purpose of this research is to examine the expression methods of Haute Couture designers' high value-added jacket designs, In order to achieve this, the positions and sizes of the design component items of tailored jackets designed by Haute Couture designers from the 1940s to the 1970s were analyzed. The results of the analysis are as follows. First, the silhouette changed while leading the contemporaneous fashions, and such changes could be confirmed by the width and length of the jacket's shoulder, chest, waist, and hem that determine the silhouette. Particularly, the length of the chest changed which signifies that the depth of the armhole was playing an important role in the production of high value-added jackets in relation to the sleeves and the fit of jackets. Second, the position and the size of the dart are the components that can express the fit of a jacket and the designer's creativity, The starting point position of the dart and the position passing by waist, and the position of the end of the dart were placed in the position beyond B.P. depending on the designer's creativity and techniques, deriving the changes of the silhouette and creating high value-added jackets. Third, the tailored collar, which was a three-dimensional component made up of the upper collar, gorge line, lapel, and break line, was an important component that could express high value-added jackets. Changes in the width and the height of the break line position of the sides of the neck were represented as changes in the neck size of the collar, and changes in the vertex locations of the upper collar corner-point, the gorge line (the corner-point of the lapel and V zone) were also represented as diverse tailored collar designs. And the differences in the width and the length of each component of the collar were related to each other and represented as changes in the slope and angle of the collar outline. Fourth, the changes in sleeve designs of the jacket were in such items as the width of the sleeve opening, the width of the sleeve hem, and the length of the sleeve, and were represented as diverse sleeve designs such as widened sleeve opening types, and straight line types.

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

The Effects of the Balance Training Program on the Excercise Performance and Injuries (정적균형훈련이 운동수행력 및 상해발생에 미치는 영향(탄성을 이용한))

  • Park, Sung-Hark
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.3
    • /
    • pp.14-27
    • /
    • 2004
  • This study approaches the effects of Balance Training on excercise performance and the prevention from the injuries caused by excercise. The subjects of the Balance Training program are female exercise beginners and the research period covers 8 weeks from January 10 to March 7, 2003. The research objects are 19 female golf beginners in 30s to 40s, who live in Seoul or Seongnam in Gyeonggi province and have played golf less than 6 months. The programs of the Balance Training and exercise performance were conducted to an 11 experimental group among the 19 research objects at the same time, and only the exercise performance program was applied to an 8 control group for 8 weeks. Before and after 8 weeks' application of the research programs to each group, the research subjects were examined, especially the components of their bodies, the balance and the performance capability were measured both before and after the test. The frequency of injuries by exercise was measured after the test, and the difference of the frequency was compared with the frequency before exercise. First, the experimental group, in a measurement of balance, showed that SN, MB, SAr and SAg of static balance decreased in a situation of MEO, MEC, GEO, GEC, TBEO, TBO, FHEO, FEO(p <0.05), but the control group increased. Second, the analysis on the change of exercise performance indicated better improvement in distance, ball speed, and accuracy of the experimental group than the control group(p<0.05). Third, the experience of injuries showed that there were 2 injuries in the experimental group and 11 injuries in the control group. The injured parts were 2 cases in the hands and fingers of the experimental group, and 1 case in the shoulder, 4 in the elbows, 4 in the hands and fingers and 2 in the lumber of the control group. From the above-mentioned results, it is recognized that the Balance Training program improved the exercise performance of female golf beginners and had good effects on the prevention from injuries. Accordingly, if this program is applied to sports-beginners, it will contribute to the improvement of the public health.

  • PDF

The Biomechanical Study on the Timings of Tkatchev Motion in Horizontal Bar (중고등학교 우수 선수의 철봉 Tkatchev 기술의 순간 동작 시점에 관한 운동역학적 연구)

  • Lim, Kyu-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.2
    • /
    • pp.121-128
    • /
    • 2019
  • Objective: The aim of this study was to examine the relation between swing phase and airborne phase of Tkatchev motion which was successfully performed with following motion by excellent middle and high school athletes in horizontal bar. Method: The subjects for this study were 8 male middle and high school top athletes. After their Tkatchev motions were filmed by two digital highspeed camcorders setting in 90 frames/sec at the 44th National Gymnastics against Cities and Provinces, the % lapse time lapse time of each instant, inferred maximum force acting on horizontal bar, and other kinematical variables were calculated through DLT method. After the relations among the % lapse times of each instants of downswing-start, downswing-finish, whipswing-finish, release, peak-height, and lapse time of regrasp, the relation among maximum force acting on bar, % lapse time, peak height, and the relation between % lapse time and release height were examined, the biomechanical timing characteristics of Tkatchev motion were as follows. Results: Firstly, it was revealed that the whole lapse time was $1.62{\pm}.06s$ and the correlation between the % lapse time of downswing-start and % lapse time of release was .819. Secondly, it was revealed that the pattern of COG path was shifted forwardly and tilted 11 clockwise from origin. Thirdly, it was revealed that maximum force acting on bar was inferred in $2,283{\pm}425N$ ($4.7{\pm}.6BW$) and the correlation between maximum force and peak height was r = .893. Lastly, it was revealed that the horizontal and vertical component of body COG velocity was $-2.14{\pm}.29m/s$, $2.70{\pm}.43m/s$ respectively, release height was $.49{\pm}.12m$, and shoulder angle was $139{\pm}5deg$, and that the later the % lapse time of release, the higher the release height (r = .935). Conclusion: It is desired that the gymnastic athletes should delay the downswing-start near the horizontal plane on $2^{nd}$ quadrant because the later the % lapse time of downswing, the higher the release height. After all the higher release height could ensure the athletes to regrasp the bar safely, the athletes should exercise to make downswing-start delay.

The Comparative Kinematic Analysis of a Volleyball Spike Serve (배구 스파이크 서브 동작의 운동학적 비교 분석)

  • Park, Jong-Chul;Back, Jin-Ho;Lee, Jin-Taek
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.671-680
    • /
    • 2009
  • We performed a study to obtain kinematic data on the characteristics of spike serving techniques used by volleyball players, including other basic data that will be useful for in-field applications. We used three-dimensional videography to compare good tough serves and serve errors. The subjects were 3 left attackers whose spike serves were videographed (60 fileds/s). The three-dimensional coordinates were calculated using the direct linear transformation method and then analyzed using the Kwon 3D software program version 3.1. There was no difference in time elapsed. However, the vertical displacement of the center of body mass(CM) differed between the 2 types of serves: in successful serves, the CM tended to be lower, as did the maximum ball height at the time of hitting. Further, the higher the level of the hitting hand was at the moment of impact, the higher was the likelihood of scoring points. In good serves, the players tended to accelerate their CM movement just before jumping to hit the ball and descend rapidly at the moment of hitting. The hand speed along with ball velocity during the impact was proven to be higher in successful serves. Moreover, in successful serves, the shoulder angles increased to a greater extent while the elbow angles were maintained constant. This possibly resulted in faster and more precise serves. An important observation was that the angle of trunk inclination during the jump did not increase with the swing of the shoulders, muscle tendon complex.