• Title/Summary/Keyword: angle

Search Result 24,740, Processing Time 0.057 seconds

Studies on the Hereditary Characters and Some Economical Traits of Korean Native Ogol Fowl IV. Body Growth and Meat Production Ability (한국재래오골계의 유전 및 경제형질에 관한 연구 IV. 체성장과 산육능력)

  • 한성욱;오봉국;김상호
    • Korean Journal of Poultry Science
    • /
    • v.15 no.1
    • /
    • pp.1-19
    • /
    • 1988
  • A study was carried out to investigate meat production ability of Korean native Ogol fowl (Natural Monument No, 265). The aims of this study were to provide basal data necessary for preserve of purebred and improvement of meat production ability of this breed. A total 300 chickens were used in this study. All the chickens were ad libitum fed broiler starter during period from 0 to 4 weeks of age and broiler finisher during period from 5 to 16 weeks of age. The investigated items are as follows; body weight; growth rate: weight of edible end inedible parts; and body shape components. The results obtained are summarized as follows. 1. Average body weight in male, female, and unsexed, of native Ogol fowls were $659.0{\pm}154.9$, $588.3{\pm}68.0$ and $623.7{\pm}121.9$ at 8 weeks of age, and $938.1{\pm}72.6$, $810{\pm}104.4$ and $874.1{\pm}109.4$g at 10 weeks of age, respectively. 2. The growth rates, unsexed, during periods 2~4, 4~6, 6~8 and 8~10 weeks of age were 166, 106, 41 and 40%, respectively. 3. The growth pattern of total edible parts in both sexes were highly significant by weeks. Total weight of edible parts in male and female were $395.4{\pm}$ and $355.6{\pm}42.0$g at 8 weeks of age, $597.5{\pm}$47.2 and $518.7{\pm}98.5$69.7g at 10 weeks of age. Percentage of total edible parts, unsexed, were 60~63% of body weight during periods from 8 to 10 weeks of age. 4. Edible giblet, unsexed, at age of 8 and 10 weeks were 4~6% of body weight. 5. Percentage of body weight of inedible part were on the decreased by weeks. The amount of blood blooded, feather plucked, inedible viscera and total inedible parts, unsexed, at 8 weeks of age were 4, 7, 12 and 31% of live body weight, respectively. 6. Except breast angle and shank diameter, the other body shape components significantly grew from 2 to 10 weeks of age. Different between male and female at 8 weeks of age were significant in breast girth, keel length, drumstick girth and shank diameter. 7. In both sexes, highly significant differences were found in the correlation coefficients between live body weight and several other body shape component, i. e., breast girth, drumstick girth, and edible part.

  • PDF

The Types, Roles and Socio-semiotic Features of Visual Materials in Elementary Science Textbooks (초등 과학 교과서에 실린 시각 자료의 종류, 역할 그리고 사회-기호학적 특징 분석)

  • Kim, Hyoungjin;Shin, Myeong-Kyeong;Lee, Gyuho;Kwon, Gyeong-Pil
    • Journal of Science Education
    • /
    • v.38 no.3
    • /
    • pp.641-656
    • /
    • 2014
  • This study aimed at analyzing visual materials included in school science textbooks, specifically the textbooks for first semester courses of 3rd to 6th graders. The purpose was to provide directions for future textbooks by understanding the functions of the images in both pedagogical and social perspectives as well. The study was conducted by investigating the types, roles and socio-semiotic features of the images in science textbooks. The results were as follows. Firstly, the most used types of images in 2007 curriculum textbooks were photographs and drawn pictures. Uses of other visual aids than above were extremely rare. It was also found that as the educational level rises, the use of images for decorative functions drastically declined. The majority of the images were used in providing supplementary explanations or examples. This implies that the images effectively play the role of helping science education. In addition, more use of worksheets images was found, indicating that as educational level increases, students participate more actively in research sessions or data analysis. In socio-semiotic perspective, visual images showed high accessibility to students in 'Type of visual image', 'Function of visual image', 'Distance of shot', 'Horizontal angle of shot', 'Color moduation'. It was implied that there will a close correlation between the type, role and the socio-semiotic characteristics of visual images in textbooks. For example, photograph-type visuals were mostly used as supplementary references. And when applying the socio-semiotic analysis to photograph-type visuals, they showed 'real type', 'narrative-metaphor type', and 'shadow effect' among socio-semiotic features. Such correlations implied that knowing the type of the visual image may help determining the role of the image in the textbook to some extent, and also corresponding socio-semiotic characteristics. As a result, it was possible to infer how accessible certain visual images are to students. The above results have implications for the effective use of visual images in future textbooks.

  • PDF

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

Study of Radiological Approach to Treat a Chronic Constipation (만성변비환자의 방사선학적 접근방법에 관한 고찰)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.5-12
    • /
    • 2004
  • I. Introduction : The constipation is one of the common gastrointestinal symptoms seen in the clinical practice. When people come to the clinic complaining of the constipation, it is generally one of the cases of infrequent, painful or difficult evacuation as well as the hardened feces and unsatisfactory evacuation sense. Since the constipation is heavily influenced by dietary habit as well as the social and medical environment, the diagnostic radiology is useful to establish the objective and standardized definition in consideration of those various factors before diagnosis and treatment of the constipation patient. This paper describes the study of such diagnosis. II. Main Subject : Testing of CTT (colon transit time) is key study of the colon performance. CTT is very helpful in classifying the pathologic physiological types and defining the treatment plan for the chronic constipation. The study methods include using the radipaque marker, multiple marker technique and scintigraphic measurement. The defecography is the functional radiologic examination a that provides not only the anatomical information of anorectal but also performance of the pelvic floor and rectal change during evacuation. Study of dynamic movement of the anorectal during evacuation is helpful for diagnosis and treatment planning as well as follow-up testing for the constipation patient. One of the issues essential for the case history is the thorough observation of whether the patient shows the psychic psychological symptoms such as the behavior disorder or emotional disturbance. In that case, the decision must be made whether or which type of medication is needed for such psychiatric problem. III. Conclusion : The main causes of the constipation are insufficient intake of fiber or liquid. The key objective of such tests is to check etiology of the constipation. In general, the radiological examination does not provde the colon or anorectal performance information. It is envisaged that this study will provide the information to decide the testing and treatment plans and predict the prognosis of the patient by classifying the pathologic physiological types.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

Study on the Improvement of Gill Nets and Trap Nets Fishing for the Resource Management at the Coastal Area of Yellow Sea - On the Entrapping Behavior of Fishes into Trap Nets in the Water Tank Experiment - (서해구 자원관리형 자망ㆍ통발 어구어법 기술개발에 관한 연구 - 수조에서의 통발에 대한 어군의 입롱행동 -)

  • 장호영;조봉곤;고광수;한민숙
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.1
    • /
    • pp.56-62
    • /
    • 2003
  • To investigate the entrapping behavior of blue crab, rock shell and green ling, which are mainly caught with the other trap nets in the coastal area of Yellow Sea, by the using duration of trap nets through the water tank experiment. We select the three kinds of trap nets which have different using duration such as new, 6 months and 12 months used one, and observe the entrapping ratio into the trap nets, respectively. In the mean while, in order to obtain the basic data for the estimate of mesh selectivity of the other trap nets, the entrapping behavior into the trap nets for green ling which has high activity compared to blue crab and rock shell, are examined to the three kinds of mesh size (35mm, 50mm and 65mm). The results are as follows ; 1. The mean entrapping ratio of blue crab by the using duration of trap nets in high with 4.4 fishes (44.0%) in the 6 months used one, become lower with 2.9 fishes (28.0%) in the new one, and with 2.0 fishes (20.0%) in the 12 months used one. 2. The mean entrapping ratio of rock shell by the using duration of trap nets in high with 7.3 fishes (36.7%) in the new one, and become lower with 7.2 fishes (35.8%) in the 6 months used one, and with 5.7 fishes (28.3%) in the 12 months used one. 3. The mean entrapping ratio of green ling by the using duration of trap nets in high with 3.4 fishes (34.0%) in the 6 months used one, and become lower with 3.0 fishes (30.0%) in the new one, and with 2.8 fishes (28.0%) in the 12 months used one. 4. The mean residual ratio of green ling by the mesh size of trap nets is high with 2.4 fishes (24.0%) in the 35mm mesh size, and become lower with 2.2 fishes (22.0%) in the 50mm mesh size and 2.0 fishes (20.0%) in the 65mm mesh size.

Contralateral Breast Dose Reduction Using a Virtual Wedge (가상쐐기를 이용한 반대측 유방선량감소)

  • Yeo, In-Hwan;Kim, Dae-Yong;Kim, Tae-Hyun;Shin, Kyung-Hwan;Chie, Eui-Kyu;Park, Won;Lim, Do-Hoon;Huh, Seung-Jae;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.230-235
    • /
    • 2005
  • Purpose: To evaluate the contralateral breast dose using a virtual wedge compared with that using a Physical wedge and an open beam in a Siemens linear accelerator. Materials and Methods: The contralateral breast dose was measured using diodes placed on a humanoid phantom. Diodes were placed at 5.5 cm (position 1), 9.5 cm (position 2), and 14 cm (position 3) along the medial-lateral line from the medial edge of the treatment field. A 6-MV photon beam was used with tangential irradiation technique at 50 and 230 degrees of gantry angle. Asymmetrically collimated $17{\times}10cm$ field was used. for the first set of experiment, four treatment set-ups were used, which were an open medial beam with a 30-degree wedged lateral beam (physical and virtual wedges, respectively) and a 15-degree wedged medial beam with a 15-degree wedged lateral beam (physical and virtual wedges, respectively). The second set of experiment consists of setting with medial beam without wedge, a 15-degree wedge, and a 50-degree wedge (physical and virtual wedges, respectively). Identical monitor units were delivered. Each set of experiment was repeated for three times. Results: In the first set of experiment, the contralateral breast dose was the highest at the position 1 and decreased in order of the position 2 and 3. The contralateral breast dose was reduced with open beam on the medial side ($2.70{\pm}1.46%$) compared to medial beam with a wedge (both physical and virtual) ($3.25{\pm}1.59%$). The differences were larger with a physical wedge ($0.99{\pm}0.18%$) than a virtual wedge ($0.10{\pm}0.01%$) at all positions. The use of a virtual wedge reduced the contralateral breast dose by 0.12% to 1.20% of the proscribed dose compared to a physical wedge with same technique. In the second experiment, the contralateral breast dose decreased in order of the open beam, the virtual wedge, and the physical wedge at the position 1, and it decreased in order of a physical wedge, an open beam, and a virtual wedge at the position 2 and 3. Conclusion: The virtual wedge equipped in a Siemens linear accelerator was found to be useful in reducing dose to the contralateral breast. Our additional finding was that the surface dose distribution from the Siemens accelerator was different from a Varian accelerator.

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

Supraclavicular Brachial Plexus block with Arm-Hyperabduction (상지(上肢) 외전위(外轉位)에서 시행(施行)한 쇄골상(鎖骨上) 상완신경총차단(上腕神經叢遮斷))

  • Lim, Keoun;Lim, Hwa-Taek;Kim, Dong-Keoun;Park, Wook;Kim, Sung-Yell;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.1 no.2
    • /
    • pp.214-222
    • /
    • 1988
  • With the arm in hyperabduction, we have carried out 525 procedures of supraclavicular brachial plexus block from Aug. 1976 to June 1980, whereas block with the arm in adduction has been customarily performed by other authors. The anesthetic procedure is as follows: 1) The patient lies in the dorsal recumbent position without a pillow under his head or shoulder. His arm is hyperabducted more than a 90 degree angle from his side, and his head is turned to the side opposite from that to be blocked. 2) An "X" is marked at a point 1 cm above the mid clavicle, immediately lateral to the edge of the anterior scalene muscle, and on the palpable portion of the subclavian artery. The area is aseptically prepared and draped. 3) A 22 gauge 3.5cm needle attached to a syringe filled with 2% lidocaine (7~8mg/kg of body weight) and epineprine(1 : 200,000) is inserted caudally toward the second portion of the artery where it crosses the first rib and parallel with the lateral border of the muscle until a paresthesia is obtained. 4) Paresthesia is usually elicited while inserting the needle tip about 1~2 em in depth. If so, the local anesthetic solution is injected after careful aspiration. 5) If no paresthesia is elicited, the needle is withdrawn and redirected in an attempt to elicit paresthesia. 6) If, after several attempts, no paresthesia is obtained, the local anesthetic solution is injected into the perivascular sheath after confirming that the artery is not punctured. 7) Immediately after starting surgery, Valium is injected for sedation by the intravenous route in almost all cases. The age distribution of the cases was from 11 to 80 years. Sex distribution was 476 males and 49 females (Table 1). Operative procedures consisted of 103 open reductions, 114 skin grafts combined with spinal anesthesia in 14, 87 debridements, 75 repairs, i.e. tendon (41), nerve(32), and artery (2), 58 corrections of abnormalities, 27 amputations above the elbow (5), below the elbow (3) and fingers (17), 20 primary closures, 18 incisions and curettages, 2 replantations of cut fingers. respectively (Table 2). Paresthesia was obtained in all cases. Onset of analgesia occured within 5 minutes, starting in the deltoid region in almost all cases. Complete anesthesia of the entire arm appeared within 10 minutes but was delayed 15 to 20 minutes in 5 cases and failed in one case. Thus, our success rate was nearly 100%. The duration of anesthesia after a single injection ranged from $3\frac{1}{2}$ to $4\frac{1}{2}$, hours in 94% of the cases. The operative time ranged from 0.5 to 4 hours in 92.4% of the cases(Table 3). Repeat blocks were carried out in 33 cases when operative times which were more than 4 hours in 22 cases and the others were completed within 4 hours (Table 4). Two patients of the 33 cases, who received microvasular surgery were injected twice with 2% lidocaine 20 ml for a total of $13\frac{1}{2}$ hours. The 157 patients who received surgery on the forearms or hands had pneumatic tourniquets (250 torrs) applied without tourniquet pain. There was no pneumothorax, hematoma or phrenic nerve paralysis in any of the unilateral and 27 bilateral blocks, but there was hoarseness in two, Horner's syndrome in 11 and shivering in 7 cases. No general seizures or other side effects were observed. By 20ml of 60% urcgratin study, we confirm ed the position of the needle tip to be in a safer position when the arm is in hyperabduction than when it is in adduction. And also that the humoral head caused some obstraction of the distal flow of the dye, indicating that less local anesthetic solution would be needed for satisfactory anesthesia. (Fig. 3,4).

  • PDF

Experimental Study on the Hysteresis of Suction Stress in Unsaturated Sand (불포화 모래의 흡입응력 이력현상에 대한 실험적 연구)

  • Song, Young-Suk;Choi, Jin-Su;Kim, Gyo-Won
    • The Journal of Engineering Geology
    • /
    • v.22 no.2
    • /
    • pp.145-155
    • /
    • 2012
  • The matric suction and volumetric water content of Jumunin standard sand with a relative density of 60% were measured using an Automated Soil-Water Characteristic Curve (SWCC) apparatus during both drying and wetting processes. The test time for the drying process was longer than that for the wetting process, because the flow of water is likely to be protected by air trapped in voids within the soils during the drying process. Based on the matric suction and volumetric water content, the SWCC was estimated using the model proposed by van Genuchten (1980). For the drying process, the unsaturated fitting parameters ${\alpha}$, n, and m were 0.399, 8.586, and 0.884, respectively; for the wetting process, the values were 0.548, 5.625, and 8.220, respectively. The hysteresis phenomenon occurred in the SWCCs, which means the SWCC of the drying process is not matched with the SWCC of the wetting process. Using these unsaturated parameters, we estimated the Suction Stress Characteristic Curve (SSCC), based on the relationship between suction stress and the effective degree of saturation. The suction stress showed a rapid decrease when the matric suction exceeds the Air Entry Value (AEV). Therefore, the effective stress of unsaturated soils is different from that of saturated soils when the matric suction exceeds the AEV. The suction stress of the drying process exceeds that of the wetting process for a given effective degree of saturation. The hysteresis phenomenon was also recognized in SSCCs. The hysteresis phenomenon of SSCCs arises from that of SWCCs, which is induced by the ink bottle effect and the contact angle effect. In the case of a sandy slope, the suction stress is positive and acts to enhance the slope stability as the water infiltrates the ground, but is negative when the suction stress exceeds the AEV. The results obtained for the wetting process should be applied in analyses of slope stability, because the process of water infiltration into ground is similar to the wetting process.