• Title/Summary/Keyword: and resonance

Search Result 10,646, Processing Time 0.05 seconds

Subhamonic Resonances of order 1/2 of Continuous Rotor with Nonlinearity and Internal Resonances (비선형 연속축의 1/2차 분수조화진동 및 내부공진)

  • 남궁재관;이성우
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.43-50
    • /
    • 2001
  • Subharmonic resonances of order 1/2 of a continuous rotating shaft with distributed mass are discussed. The restoring force of the shaft exhibits geometric stiffening nonlinearity due to the extension of the shaft center line. It is assumed that a distributed lateral force, such as the gravity, acts on the rotor. The possibility of the occurrence of subharmonic resonances, the shapes of resonance curves, and internal resonance phenomena are investigate.

  • PDF

Josephson plasma excitation in vortex states

  • Kadowaki, K.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.21-21
    • /
    • 2000
  • The Josephson Plasma resonance in single crystalling Bi2Sr2CaCu2O8 has been investigated at a microwave frequency of 35 GHz in a cavity resonator. A sharp resonance is observed in a perpendicular oscillating magnetic field. The former is independent of the sample dimension, shile the latter shift to higher field as the sample size L is reduced, and it disappears when L becomes smaller than the critical length. The longitudinal plasma mode is a Nambu-Goldston mode in a superconductor, the experimental distinction between the longitudinal and the transverse mode leads to the conclusion that the existence of the Nambu-Goldston mod as predicted by Anderson was experimentally confirmed by direct observation of the Josephson plasma resonance with longitudinal excitations. The finite gap found in Josephson plasma resonance also provides a direct proof of the Anderson-Higgs mechanism within the context of the spontaneously broken phase symmetry of the Gauge-field theory in a superconductor.

  • PDF

Analysis of Resonance Based Micromechanical Bio-Chemical Sensing Structures (공진 기반 마이크로기계 생화학 센싱 구조물의 해석)

  • Yeo, Min-Ku;Shin, Yoon-Hyuck;Yim, Hong-Jae;Lim, Si-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1767-1772
    • /
    • 2008
  • A microcantilever is a well-known MEMS structure for sensing bio-chemical molecules. When bio-chemical molecules are adsorbed on the microcantilever's surface, resonance frequency shift is generated. There are two issues in this phenomena. The first one is which one between mass change and surface stress change effects is more dominant on the resonance frequency shift. The second one is what will be the performance change when the boundary condition is changed from cantilevers to double clamped beams. We have studied the effect of surface stress change and compared it with that of mass change by using FEM analysis. Furthermore, for microstructures having different boundary conditions, we have studied Q-factor, which determines the detection limit of micro/nano mechanical sensors.

  • PDF

Supradiaphragmatic Liver Confirmed by a Hepatocyte-specific Contrast Agent (Gd-EOB-DTPA): A Case Report

  • Cho, Young Jong;Kim, Hyuk Jung;Bae, Young A;Jang, Suk Ki;Yeon, Jae Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.1
    • /
    • pp.52-55
    • /
    • 2015
  • Supradiaphragmatic liver is a rare condition. Establishing an accurate preoperative diagnosis is difficult. Operative exploration is necessary to differentiate this lesion from intrathoracic masses, such as a pleural based tumor, diaphragmatic tumor and peripheral lung tumor. However, with the aid of the hepatocyte-specific magnetic resonance imaging contrast agent, gadoxetic acid (Gd-EOB-DTPA), functional hepatocytes in the lesion can be identified in the hepatobiliary phase, potentially allowing an accurate and non-invasive diagnosis. We report a case of supradiaphragmatic liver diagnosed by Gd-EOB-DTPA-enhanced magnetic resonance imaging.

Magnetic Resonance Neurography Using the Anisotropy of Diffusion Coefficients (확산계수의 이방성을 이용한 자기공명 신경망조영술)

  • Lee, Su-Yeol;Mun, Chi-Ung;Im, Tae-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.401-406
    • /
    • 1994
  • A magnetic resonance neurography technique for exclusive imaging of nerve networks is proposed. In the proposed technique, the anisotropy of diffusion coefficients of the molecules inside nerve cells was utilized to effectively suppress the magnetic resonance signal radiating from ones other than nerve tissues. Two images were obtained with diffusionweighting magnetic field gradients applied in the parallel and perpendicular directions with respect to the nerve orientation. One image was then subtract- ted from the other to form the neurogram. Experimentally obtained neurograms of the squld are presented.

  • PDF

Fluxon resonance steps in the $Bi_2Sr_2CaCu_2O_{8+x}$ single crystals

  • Bae, Myung-Ho;Lee, Hu-Jong
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.138-142
    • /
    • 2007
  • We observed discrete fluxon-flow resonance steps in high magnetic fields in a stack of Josephson junctions with lateral size of $1.5{\times}17{\mu}m^2$. The measurement sample was prepared by sandwiching a stack of $Bi_2Sr_2CaCu_2O_{8+x}$ intrinsic Josephson junctions between two Au electrodes by using the double-side-cleaving technique. This technique allowed us to isolate the intrinsic Josephson junction structures from the inductive interference of the basal stack. The resonance steps observed are in good agreement with the collective Josephson fluxon dynamics that are in resonance with the plasma oscillation modes inside the stacked Josephson junctions.

  • PDF

Numerical analysis on the pressure pulsation in the resonance tube (Resonance tube 내 압력 맥동 해석)

  • 곽승철;류호선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.608-614
    • /
    • 1997
  • 2차원 압축성 오일러 방정식을 지배 방정식으로 하여 음향학적 문제를 직접 수치 계산하였다. Roe의 개략적인 리만해(Approximate Riemann Solver)에 의거하여 대류항을 구성하였고 높은 정확도를 유지하기 위해 Vanleer의 MUSCL 방법을 사용하여 공간을 이산화하였다. 시간 적분으로는 2차의 Runge-Kutta 방법을 사용하였다. Resonance tube 내의 음향학적 문제 해석을 위해 최근까지 제시된 음향 경계 조건들을 비교하였고 각 경계 조건들이 갖는 물리적 의미를 고찰하였다. 이들을 통하여 압력파의 물리적인 행태를 모사하였고 실험과 비교하였다. 계산결과들을 통하여 사용된 방법은 전형적인 압축성 유동 해석 문제 뿐만 아니라 선형, 비선형의 음향학적 문제들을 적절한 경계 조건과 결합하여 해석할 수 있음을 알 수 있었고 resonance tube와 같은 공학적으로 실제적인 문제들에 대한 응용이 기대된다.

  • PDF

A Study On Design of Resonance Frequency for Wireless Power Transfer with Magnetic Resonance Type (자기공명형 무선전력송신을 위한 공진 주파수 설계에 관한 연구)

  • Ahn, Joon-Seon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.4
    • /
    • pp.206-210
    • /
    • 2012
  • In this paper wireless power transmission is discussed. The concept of non-radiative magnetic coupled resonance type wireless power transmission was introduced by MIT team at 2007, non-radiative type has been focused by many researchers. Authors present design of circuit parameters including driving frequency and verify the design by computer simulation.

A Novel Transmission Line Characterization Based on Measurement Data Reconfirmation

  • Eo, Yungseon
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.17-27
    • /
    • 2016
  • In the high-frequency characterizations of planar circuit components, measurement data may not be physical. It is mainly due to resonance effects concerned with discontinuities which are inevitable for a planar component characterization. In this paper, a novel accurate transmission line characterization method is presented that excludes the resonance effects based on measurement data reconfirmation. For the physically obvious data acquisition near the resonance frequencies of a transmission line, the additional lines with different line lengths are fabricated on the same substrate. The test transmission lines are characterized by using vector network analyzer (VNA) in 100 MHz to 26.5 GHz. It is shown that an accurate transmission line characterization can be achieved with the proposed measurement data reconfirmation technique.