• Title/Summary/Keyword: and resonance

Search Result 10,646, Processing Time 0.041 seconds

Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery (방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검)

  • Chung, Hyun-Tai;Lee, Re-Na
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.47-51
    • /
    • 2008
  • Objective: This study analyzed errors due to rotation or tilt of the magnetic resonance (MR) imaging indicator during image acquisition for a stereotactic radiosurgery. The error correction procedure of a commercially available stereotactic neurosurgery treatment planning program has been verified. Materials and Methods: Software virtual phantoms were built with stereotactic images generated by a commercial programming language, Interactive Data Language (version 5.5). The thickness of an image slice was 0.5 mm, pixel size was $0.5{\times}0.5mm$, field of view was 256 mm, and image resolution was $512{\times}512$. The images were generated under the DICOM 3.0 standard in order to be used with Leksell GammaPlan$^{(R)}$. For the verification of the rotation error correction function of Leksell GammaPlan$^{(R)}$, 45 measurement points were arranged in five axial planes. On each axial plane, there were nine measurement points along a square of length 100 mm. The center of the square was located on the z-axis and a measurement point was on the z-axis, too. Five axial planes were placed at z=-50.0, -30.0, 0.0, 30.0, 50.0 mm, respectively. The virtual phantom was rotated by $3^{\circ}$ around one of x, y, and z-axis. It was also rotated by $3^{\circ}$ around two axes of x, y, and z-axis, and rotated by $3^{\circ}$ along all three axes. The errors in the position of rotated measurement points were measured with Leksell GammaPlan$^{(R)}$ and the correction function was verified. Results: The image registration errors of the virtual phantom images was $0.1{\pm}0.1mm$ and it was within the requirement of stereotactic images. The maximum theoretical errors in position of measurement points were 2.6 mm for a rotation around one axis, 3.7 mm for a rotation around two axes, and 4.5 mm for a rotation around three axes. The measured errors in position was $0.1{\pm}0.1mm$ for a rotation around single axis, $0.2{\pm}0.2mm$ for double and triple axes. These small errors verified that the rotation error correction function of Leksell GammaPlan$^{(R)}$ is working fine. Conclusion: A virtual phantom was built to verify software functions of stereotactic neurosurgery treatment planning program. The error correction function of a commercial treatment planning program worked within nominal error range. The virtual phantom of this study can be applied in many other fields to verify various functions of treatment planning programs.

Central Nervous System Complications of Coronary Artery Bypass Grafting - Comparison Between Off-Pump CABG and Conventional CABG (관상동맥 우회술 후의 중추신경계 합병증 - 심폐바이패스를 사용하지 않은 관상동맥 우회술과 기존의 관상동맥 우회술의 비교)

  • Chang, Ji-Min;Lee, Jeong-Sang;Kim, Ki-Bong;Ahn, Hyuk;Yoon, Byung-Woo;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.33 no.12
    • /
    • pp.941-947
    • /
    • 2000
  • Background: Central nervous system complication after coronary artery bypass grafting(CABG) is one of the major prognostic determinants and the use of the cardiopulmonary bypass(CPB) may increase the incidence of this devastating complication. In this study, the outcomes after off-pump CABG were studied and compared with those following the conventional CABG using CPB. Material and Method: Among the consecutive isolated CABG's performed in SNUH during Feb. 1995 and Jun. 1999, 338 coronary artery bypass grafting were divided into two groups. 223 patients underwent CABG using the CPB(Group I), and 115 patients underwent CABG without CPB(OPCAB)(Group II). All patients enrolled in this study received extensive preoperative examinations including thorough neurologic examination before and after surgery, transcranial doppler study, carotid duplex ultrasonography, and magnetic resonance angiography if necessary. Central nervous system(CNS) complications were defined as stroke, seizure, metabolic or hypoxic encephalopathy and transient delirium after surgery. Result: There were 61 cases(27.3%) who developed postoperative CNS complication in Group I, whereas 8 cases(7.0%) of CNS complications developed postoperatively in group II(p<0.05). Statistically significant predictors of postoperative CNS complications in group I were age and the use of cardiac assist devices perioperatively. Conclusion: This study suggested that omitting the use of CPB in CABG resulted in significant decrease of the postoperative CNS complications. OPCAB should be more widely applied especially to the elderly who have preexisting cerebrovascular disease.

  • PDF

Identification of novel mutations of the ATP7A gene and prenatal diagnosis of Menkes disease by mutation analysis (DNA 분석을 이용한 ATP7A 유전자의 새로운 돌연변이 발견과 멘케스병의 산전 진단)

  • Choi, Jin-Ho;Kim, Gu-Hwan;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.38-44
    • /
    • 2007
  • Purpose : Menkes disease is an X-linked recessively inherited disorder caused by the mutation of the ATP7A gene encoding copper-transporting P-type AT Pase. The phenotypic features are progressive neurological degeneration, mental retardation, loose skin, and vascular complications. Early diagnosis and treatment are very important for the prognosis of Menkes disease. Here, we describe nov el mutations of the ATP7A gene and prenatal diagnosis by mutation analysis. Methods : Five unrelated Korean Menkes patients were included in this study. They presented with depigmented wool-like hair, progressive neurologic deterioration, and hypotonia in infancy. Serum copper and ceruloplasmin levels w ere decreased. Brain magnetic resonance imaging revealed tortuous intracranial vessels. Mutation analysis has been carried out using cDNA from cultured skin fibroblasts or genomic DNA from peripheral leukocytes. Prenatal diagnosis was performed in two cases using chorionic villi samples or amniocytes. Results : Four novel mutations have been identified from four different families; c.3511+1G>A (p.E1099_N1171delinsMfsX 18), c.4005+5 G>A (p.V1268_R1335del), c.1870_2172del (p.S624_Q724del), and c.3352 G>A (p.G1118S). T he remaining one was previously reported (c.1933 C>T (p.V 1268_R1335del)). On prenatal DNA analysis, one w as diagnosed as normal, while the other turned out to be a female heterozygote with p.S624_Q724del mutation of the ATP7A gene. Conclusion : We identified 4 novel mutations of the ATP7A gene. Prenatal diagnosis in families at risk is critical in order to choose preventiv e options including an early treatment with copper-histidine therapy or therapeutic termination. Most mutations of the ATP7A gene were frame-shift mutations and prenatal diagnosis has been successfully carried out.

  • PDF

Effect of Lead Content on Atomic Structures of Pb-bearing Sodium Silicate Glasses: A View from 29Si NMR Spectroscopy (납 함량에 따른 비정질 Pb-Na 규산염의 원자 구조에 대한 고상 핵자기 공명 분광분석 연구)

  • Lee, Seoyoung;Lee, Sung Keun
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.3
    • /
    • pp.157-167
    • /
    • 2021
  • Lead (Pb) is one of the key trace elements, exhibiting a peculiar partitioning behavior into silicate melts in contact with minerals. Partitioning behaviors of Pb between silicate mineral and melt have been known to depend on melt composition and thus, the atomic structures of corresponding silicate liquids. Despite the importance, detailed structural studies of Pb-bearing silicate melts are still lacking due to experimental difficulties. Here, we explored the effect of lead content on the atomic structures, particularly the evolution of silicate networks in Pb-bearing sodium metasilicate ([(PbO)x(Na2O)1-x]·SiO2) glasses as a model system for trace metal bearing natural silicate melts, using 29Si solid-state nuclear magnetic resonance (NMR) spectroscopy. As the PbO content increases, the 29Si peak widths increase, and the maximum peak positions shift from -76.2, -77.8, -80.3, -81.5, -84.6, to -87.7 ppm with increasing PbO contents of 0, 0.25, 0.5, 0.67, 0.86, and 1, respectively. The 29Si MAS NMR spectra for the glasses were simulated with Gaussian functions for Qn species (SiO4 tetrahedra with n BOs) for providing quantitative resolution. The simulation results reveal the evolution of each Qn species with varying PbO content. Na-endmember Na2SiO3 glass consists of predominant Q2 species together with equal proportions of Q1 and Q3. As Pb replaces Na, the fraction of Q2 species tends to decrease, while those for Q1 and Q3 species increase indicating an increase in disproportionation among Qn species. Simulation results on the 29Si NMR spectrum showed increases in structural disorder and chemical disorder as evidenced by an increase in disproportionation factor with an increase in average cation field strengths of the network modifying cations. Changes in the topological and configurational disorder of the model silicate melt by Pb imply an intrinsic origin of macroscopic properties such as element partitioning behavior.

Giant Schwannoma May Mimic Soft Tissue Sarcoma (악성 연부 종양으로 오인하기 쉬운 신경 및 연부조직의 거대 신경초종)

  • Kim, Yongsung;Jeon, Dae-Geun;Cho, Wan Hyeong;Song, Won Seok;Kim, Kyunghoon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.511-519
    • /
    • 2020
  • Purpose: Schwannoma is a benign tumor that occurs mainly in the peripheral nerve. If the tumor is large or is in areas other than the nerves, it is likely to be mistaken for malignant soft tissue tumors. The authors reviewed 50 cases of giant schwannomas and assessed the distribution of the primary locations, clinical symptoms, radiological and pathological diagnosis, and diagnostic accuracy. Materials and Methods: Of the 214 pathologically confirmed schwannomas, 50 cases with a maximum diameter of 5 cm or more were extracted. The entire cohort was classified into three subgroups (major peripheral nerve, intramuscular, bone) according to the primary location, and the anatomical locations were specified. Results: When the entire cohort was classified according to the primary location, 14 tumors occurred in the major peripheral nerve, 31 cases in the muscle, and 5 cases in the bone. The mean size of the tumor in the entire cohort was 7.0 cm, and the intramuscular subgroup had the largest size with 8.0 cm. The radiological diagnosis revealed 33 out of 50 cases to be benign schwannoma (66.0%), 15 cases as low-grade malignancy (30.0%), and the remaining two cases (4.0%) as a suspicious tuberculosis abscess and tenosynovial giant cell tumor, respectively. On the clinical symptoms, Tinel sign was the most common in the peripheral nerve group with 78.6% (11/14), while 93.5% of the intramuscular group had palpation of the mass with a mean duration of 66.6 months. In the bone group, one out of five cases was reported as a low-grade malignancy. Two cases of postoperative complications were encountered; one was bleeding after tumor excision, which required hemostasis, and the other was peroneal nerve palsy after surgery. Conclusion: When assessing the large-sized soft tissue tumors in the muscles, the possibility of a benign schwannoma should be considered if 1) there is a long period of mass palpation and 2) non-specific findings in MRI. Preoperative pathology confirmation with a biopsy can help reduce the risk of overtreatment.

Arthroscopic Full-Thickness Rotator Cuff Repair in Elderly Patients (고령 환자의 관절경적 회전근 개 봉합술의 결과)

  • Cheon, Sang Jin;Lee, Dong Ho;Park, Yong Geon;Son, Seung Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.38-45
    • /
    • 2020
  • Purpose: To examine the clinical and structural outcomes of an at least two-year follow-up of arthroscopic full-thickness rotator cuff repairs with a single-row or suture-bridge technique in patients more than 65 years of age. Materials and Methods: Patients diagnosed with a full-thickness rotator cuff tear who were more than 65 years of age, underwent arthroscopic rotator cuff repair after at least six months of conservative treatment, agreed to take a follow-up magnetic resonance imaging (MRI) six months postoperatively, and visited outpatient for at least two years were enrolled in this study. Clinical evaluations were done using The University of California Los Angeles score, Constant Shoulder Score, and visual analogue scale evaluated two years after the surgery. The structural integrity was analyzed using follow-up MRI. During surgery, a suture-bridge technique was used if the rotator cuff tendon could cover half of the footprint under constant tension. Otherwise, single-row repair was performed. Results: The samples were 158 cases, consisting of 93 single-repairs and 65 suture-bridge repairs. A preoperative comparison of the age distribution, fatty degeneration of supraspinatus and infraspinatus muscle, medial retraction of torn cuff tendon, and tear size between the two groups were not significant. The clinical scores were improved significantly in all cases. The distribution of the structural integrity by Sugaya classification were 49 cases in type 1 (31.0%), 62 cases in type 2 (39.2%), 30 cases in type 3 (19.0%), 11 cases in type 4 (7.0%), and six cases in type 5 (3.8%). The re-tear rate of the single-row group was 9.7% (nine out of 93 cases) and 12.3% (eight out of 65 cases) for the suture-bridge group. Conclusion: Satisfactory clinical and radiological outcomes were achieved after arthroscopic full-thickness rotator cuff repair in patients more than 65 years of age. Both single-row and suture-bridge techniques would be beneficial for the elderly.

The Relationship between Neural Foraminal Stenosis and Imaging Features of Lumbar Spine MRI in Patients Older Than 60 Years with Lumbar Radiculopathy (요추신경근병증이 있는 60세 이상의 환자에서 신경공 협착과 자기공명영상 평가를 통한 인자와의 상관관계)

  • Kyeyoung Lee;Hee Seok Jeong;Chankue Park;Maeran Kim;Hwaseong Ryu;Jieun Roh;Jeong A Yeom;Jin Hyeok Kim;Tae Un Kim;Chang Ho Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.862-875
    • /
    • 2021
  • Purpose To investigate the MRI features associated with neural foraminal stenosis (NFS) in patients older than 60 years with lumbar (L) radiculopathy. Materials and Methods This study included 133 retrospectively selected patients older than 60 years with lumbar radiculopathy who had undergone a lumbar spine MRI (from January 2018 to April 2018). For L4/L5 and L5/sacral (S)1 levels, NFS was reviewed blindly by two radiologists. Spondylolisthesis, retrolisthesis, disc height loss, disc bulging/herniation/central canal stenosis, ligamentum flavum thickening, and facet hypertrophy were evaluated separately for the NFS and non-NFS groups, and they were compared using univariate and multivariate analyses. Results The univariate analysis revealed that disc height loss (p = 0.006) was associated with NFS for L4/L5. For L5/S1, both spondylolisthesis (p = 0.005) and facet hypertrophy (p = 0.006) were associated with NFS. The multivariate logistic analysis revealed that disc height loss was associated with NFS for L4/L5 [odds ratio (OR) = 4.272; 95% confidence interval (CI) 1.736-10.514]. For L5/S1, spondylolisthesis (OR = 3.696; 95% CI 1.297-10.530) and facet hypertrophy (OR = 6.468; 95% CI 1.283-32.617) were associated with NFS. Conclusion Disc height loss was associated with NFS for L4/L5 and spondylolisthesis and facet hypertrophy were associated with NFS for L5/S1.

Early Recurrence of Breast Cancer after the Primary Treatment: Analysis of Clinicopathological and Radiological Predictive Factors (유방암 일차치료 후 조기 재발: 임상병리학적 및 영상의학적 예측인자 분석)

  • Sun Geun Yun;Yeong Yi An;Sung Hun Kim;Bong Joo Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.395-408
    • /
    • 2020
  • Purpose To evaluate the value of clinicopathologic factors and imaging features of primary breast cancer in predicting early recurrence after the primary treatment. Materials and Methods We enrolled 480 patients who had been followed-up after breast-conserving surgery and adjuvant therapy from January 2010 to December 2014 at our hospital. Early recurrence was defined as recurrence within 3 years after completion of primary treatment, and univariate and multivariate logistic regression analyses were performed to determine the clinicopathologic and imaging predictive factors of early recurrence. Results In the univariate analysis, among the clinicopathologic factors, advanced stage (p = 0.021), high histologic grade (p < 0.001), estrogen receptor negative (p = 0.002), high Ki-67 proliferation index (p = 0.017), and triple-negative breast cancer (p = 0.019), and among the imaging features, multifocality (p < 0.001), vessels in the rim on Doppler ultrasonography (US) (p = 0.012), and rim enhancement (p < 0.001) on magnetic resonance imaging of the breast were significantly associated with early recurrence. In the multivariate analysis, advanced stage [odds ratio (OR) = 3.47; 95% confidence interval (CI) 1.12-10.73; p = 0.031] and vessels in the rim on Doppler US (OR = 3.32; 95% CI 1.38-8.02; p = 0.008) were the independent predictive factors of early recurrence. Conclusion Vascular findings in the rim of the primary breast cancer on Doppler US before treatment is a radiologic independent predictive factor of early recurrence after the primary treatment.

Comparison of Dose Distribution in Spine Radiosurgery Plans: Simultaneously Integrated Boost and RTOG 0631 Protocol (척추뼈전이암 환자의 체부정위방사선치료계획 비교: 동시통합추가치료법 대 RTOG 0631 프로토콜)

  • Park, Su Yeon;Oh, Dongryul;Park, Hee Chul;Kim, Jin Sung;Kim, Jong Sik;Shin, Eun Hyuk;Kim, Hye Young;Jung, Sang Hoon;Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.176-184
    • /
    • 2014
  • In this study, we compared dose distributions from simultaneously integrated boost (SIB) method versus the RTOG 0631 protocol for spine radiosurgery. Spine radiosurgery plans were performed in five patients with localized spinal metastases from hepatocellular carcinoma. The computed tomography (CT) and T1- and T2-weighted magnetic resonance imaging (MRI) were fused for delineating of GTV and spinal cord. In SIB plan, the clinical target volume (CTV1) was included the whole compartments of the involved spine, while RTOG 0631 protocol defines the CTV2 as the involved vertebral body and both left and right pedicles. The CTV2 includes transverse process and posterior element according to the extent of GTV. The doses were prescribed 18 Gy to GTV and 10 Gy to CTV1 in SIB plan, while the prescription of RTOG 0631 protocol was applied 18 Gy to CTV2. The results of dose-volume histogram (DVH) showed that there were competitive in target coverage, while the doses of spinal cord and other normal organs were lower in SIB method than in RTOG 0631 protocol. The 85% irradiated volume of VB in RTOG 0631 protocol was similar to that in the SIB plan. However, the dose to normal organs in RTOG 0631 had a tendency to higher than that in SIB plan. The SIB plan might be an alternative method in case of predictive serious complications of surrounded normal organs. In conclusion, although both approaches of SIB or RTOG 0631 showed competitive planning results, tumor control probability (TCP) and normal tissue complication probability (NTCP) through diverse clinical researches should be analyzed in the future.

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.