• Title/Summary/Keyword: and resonance

Search Result 10,515, Processing Time 0.04 seconds

Detection of Inclusions in Concrete Slab by Impact-Resonance Method (충격공진법을 이용한 콘크리트 슬래브 내의 개재물 검출)

  • Kim, Hak-Hyun;Yim, Hyun-June;Lee, Kwang-Myong;Cho, Nam-Jun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.221-230
    • /
    • 2000
  • The usefulness and limitations of the impact-resonance method, which is a nondestructive evaluation (NDE) method for concrete, are studied by both experimental and theoretical methods. For the experimental study, several concrete slab specimens with various inclusions embedded were fabricated, and tested by the impact-resonance method. Some of the inclusions have been detected and accurately located, but some have not. The reasons for the failure in the latter cases have been investigated theoretically by using finite element analyses, from which the primary factors determining the success of the method have also been identified. This study will serve to enhance the understanding of the underlying physics and to improve the usefulness of the impact-resonance method as applied to concrete NDE.

  • PDF

Background coefficients of the scattering from dielectric cylinder and cavity in the Resonance scattering theory (원통형 유전체와 공동에 대한 전자기파 공진산란이론의 배경성분)

  • Jung, Yong-Hwa;Jeon, Sang-Bong;Ahn, Chang-Hoi;Choi, Myoung-Seon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.1
    • /
    • pp.63-70
    • /
    • 2003
  • Resonance Scattering Theory (RST) offers us an interpretation of the resonance phenomena in the scattered field. It is shown 1.hat the scattered field consists of the resonance and background components in the RST. The suitable background is necessary in order to obtain the resonance component. In this study, the background coefficients are investigated to obtain resonance components from electromagnetic scattering field for cylindrical object with different permittivities. We show some valid results valid for two models; cavity and dielectric cylinder.

  • PDF

$^{11}B$ Nuclear Magnetic Resonance Study of Calcium-hexaborides

  • Mean, B.J.;Lee, K.H.;Kang, K.H.;Lee, Moo-Hee;Lee, J.S.;Cho, B.K.
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.7 no.2
    • /
    • pp.80-88
    • /
    • 2003
  • We have performed $^{11}$ B nuclear magnetic resonance (NMR) measurements to microscopically investigate an electronic structure of the ferromagnetic state in three different compositions of calcium-hexaboride single crystals. Although the crystal structure of Ca $B_{6}$ is cubic and three NMR lines may be expected for the nuclear spin 3/2 of $_{11}$ B, a larger number of NMR resonance peaks have been observed. The frequency and intensity of those peaks distinctively changes depending on the angle between crystalline axis and magnetic field. Analyzing this behavior, we find that the electric field gradient(EFG) tensor at the boron has its principal axis perpendicular to the six cubic faces with a quadrupole resonance frequency $v_{Q}$ 600 kHz. Even though the magnetization data highlight the ferromagnetic hysteresis, $^{11}$ B NMR linewidth data show no clear microscopic evidence of the ferromagnetic state in three different compositions of Ca $B_{6}$ single crystals.s.

  • PDF

Analysis and Reduction of Subsidiary Resonance of an Optical Pickup Actuator (광 픽업 액추에이터의 부공진 원인 규명과 저감화)

  • Seo, Jin-Gyu;Jeong, Ho-Seop;Park, Gi-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.728-734
    • /
    • 2000
  • An asymmetric actuator can be used to reduce the distance between the reflective mirror and objective lens of a small optical disk drive for use in the notebook-sized personal computer data storage devices. However, this asymmetric actuator is very sensitive to the subsidiary resonance which is caused by its rigid body motion. In this paper, an analytical approach using a simple lumped parameter system model is presented with a physical insight to investigate why the subsidiary resonance occurs. The finite element method is used to figure out the force and torque characteristics of the asymmetric actuator which are essential to understand the subsidiary vibration characteristics. The frequency responses are presented to examine how the subsidiary resonance is altered for various situations of having different thickness of a yoke and permanent magnet and of having a different magnet circuit. Finally, the design guidelines to avoid the subsidiary resonance will be presented.

ESR detection of optically-induced hyperpolarization of nitrogen vacancy centers in diamond

  • An, Min-Gi;Shim, Jeong Hyun;Kim, Kiwoong;Oh, Sangwon;Jeong, Keunhong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.1
    • /
    • pp.9-15
    • /
    • 2020
  • Nitrogen vacancy center (NV center) in diamond has recently been appeared as a promising candidate for hyperpolarization applications due to its optical pumping property by laser. Optically Detected Magnetic Resonance (ODMR) has been used as a conventional method to obtain the resonance spectrum of NV centers. ODMR, however, has a shortcoming of sensitivity and a limitation of subjects, such that the degree of hyperpolarization can hardly be estimated, and that the spins other than NV centers are invisible. In contrast, Electron Spin Resonance (ESR) spectroscopy is known to proportionally reflect the degree of spin polarization. In this work, we successfully observed the optically-induced hyperpolarization of NV spins in diamond through CW-ESR spectroscopy with an X-band system. All the NV peaks were identified by calculating the eigenvalues of NV spin Hamiltonian. The intensities of NV peaks were enhanced over 240 times after optical pumping. The enhanced peaks corresponding to the transition from |ms=0> to |ms=-1> revealed inverted phases, while other peaks remained in-phase. The optically-induced hyperpolarization on NV spins can be a useful polarization source, leading to 13C nuclear hyperpolarization in diamond.

Change of Recognition Range According to Resonance Frequency of the 13.56MHz RFID Transponder (13.56MHz RFID 트랜스폰더의 공진 주파수에 따른 인식거리의 변화)

  • Yoon, Ki-Suk;Yang, Woon-Geun;Yoo, Hong-Jun
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.127-130
    • /
    • 2005
  • In this paper, we investigated the change of recognition distance according to the resonance frequency of the transponder for the ISO 14443 Type A 13.56MHz RFID(Radio Frequency IDentification) system. We made thirteen transponders of the same size. The dimension of the transponder is $84.65mm{\times}53.00mm{\times}0.45mm$. We measured the resonance frequency by means of an inductive coupling. The measured resonance frequencies were between 12.9MHz and 17.3MHz. We measured the maximum distances where the transponder's USN(Unique Serial Number) was recognized and the subcarrier was observed. The measurement results show that we can obtain good performance when the Type A transponder has the resonance frequency around 14.2MHz for the given case.

  • PDF

Identification and Damping of Resonances in Inverter-based Microgrids

  • Afrasiabi, Morteza;Rokrok, Esmaeel
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1235-1244
    • /
    • 2018
  • The application of shunt capacitor banks and underground cables typically induces resonance in power distribution systems. In this study, the propagation of resonance in a microgrid (MG) with inverter-based distributed generators (IBDGs) is investigated. If resonances are not properly damped, then the output current of the inverters may experience distortion via resonance propagation due to the adverse effect of resonances on MG power quality. This study presents a conceptual method for identifying resonances and related issues in multi-inverter systems. For this purpose, existing resonances are identified using modal impedance analysis. However, some resonances may be undetectable when this method is used. Thus, the resonances are investigated using the proposed method based on the frequency response of a closed-loop MG equivalent circuit. After analyzing resonance propagation in the MG, an effective virtual impedance damping method is used in the IBDG control system to damp the resonances. Results demonstrate the effectiveness of the proposed method in compensating for existing resonances.

Design and Vibration Reduction Method of Sub-Resonance in Asymmetric Type Optical Pick-up Actuator (FP코일을 이용한 비대칭형 광픽업 액츄에이터의 설계 및 부공진의 진동저감 대책)

  • 정호섭;오관영;유익형
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.160-165
    • /
    • 1998
  • The sub-resonance modes can be easily excited by the assembling tolerance in the asymmetric type optical pick-up actuators, compared with the symmetric type. In this paper, we propose the novel method for reducing the vibration due to the sub-resonance modes where undesirable modes can be decreased by adding the damping, which can be achieved by increasing the flexibility of holder PCB, against to the sub-resonance modes. Using the finite element method, the change of mode shapes is investigated as the shape of holder PCB is modified. Experimental results support that the proposed method reduces remarkably the vibration of sub-resonance modes of the optical pick-up actuator.

  • PDF

Determination of Elastic Modulus by Time Average ESPI and Euler-Bernoulli Equation (Time Average ESPI와 Euler-Bernoulli 방정식에 의한 탄성계수 측정)

  • Kim, Koung-Suk;Lee, Hang-Seo;Kang, Young-June;Kang, Ki-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.7 s.196
    • /
    • pp.69-74
    • /
    • 2007
  • The paper proposes a new sonic resonance test for a elastic modulus measurement which is based on time-average electronic speckle pattern interferometry(TA-ESPI) and Euler-Bernoulli equation. Previous measurement technique of elastic constant has the limitation of application for thin film or polymer material because contact to specimen affects the result. TA-ESPI has been developed as a non-contact optical measurement technique which can visualize resonance vibration mode shapes with whole-field. The maximum vibration amplitude at each vibration mode shape is a clue to find the resonance frequencies. The dynamic elastic constant of test material can be easily estimated from Euler-Bernoulli equation using the measured resonance frequencies. The proposed technique is able to give high accurate elastic modulus of materials through a simple experiment set up and analysis.

A Study on the Stabilization Scheme of Optical Source for Precision Measurement (정밀측정을 위한 안정된 광원에 관한 연구)

  • 김지대;서호성;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.265-271
    • /
    • 2003
  • This study is for the stable optical source in order to get the precision measurement, which contributes to help the laser frequency and the output to be settled. The laser optical frequency is changed by the length of resonance cavity. The length variation of the laser resonance amplitude is affected by the thermal expansion of that system. So, we try not only to adjust the temperature of the laser tube using the heater for fine length of resonance cavity, but also to maintain the fixed temperature of the resonance cavity for outputting the safe laser optical frequency. Therefore, we must take materials with the thermal expansion of the supporting system, which is closer to it of the laser resonance cavity. Using the materials, we can promote to stabilize the temperature of it. In advance, we also plan to get the settlement of the laser frequency and the output in the long km, optimizing and stabilizing the system.

  • PDF