• Title/Summary/Keyword: and low noise. efficiency

Search Result 398, Processing Time 0.033 seconds

A Study on the Noise Property and its Reduction of the FCEV Blower (FCEV 블로워의 소음특성과 개선방향에 관한 연구)

  • Oh, Ki-Seok;Lee, Sang-Kwon;Seo, Sang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1419-1424
    • /
    • 2007
  • Centrifugal turbo blower is requested highly efficiency and low noise in FCEV, but the noise generated by this machine causes of the most serious problems in the NVH performance. In general, centrifugal turbo blower is dominated by mechanical noise and aerodynamic noise. Mechanical noise is generated by rotation of the bearing, misalignment and unbalance. And aerodynamic noise is generated by the strong intersection between the flow discharged from the impeller and the cut-off in the casing. The first object of this study is to comprehend a noise property of the blower through the noise test. And, second object is to bring up the method that can reduce blower noise.

  • PDF

A Study on the Noise Property and Its Reduction of the FCEV Blower (FCEV 블로워의 소음특성과 개선방향에 관한 연구)

  • Oh, Ki-Seok;Lee, Sang-Kwon;Seo, Sang-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.5
    • /
    • pp.516-523
    • /
    • 2008
  • Centrifugal turbo blower is requested highly efficiency and low noise in FCEV, but the noise generated by this machine causes of the most serious problems in the NVH performance. In general, centrifugal turbo blower is dominated by mechanical noise and aerodynamic noise. Mechanical noise is generated by rotation of the bearing, misalignment and unbalance. And aerodynamic noise is generated by the strong intersection between the flow discharged from the impeller and the cut-off in the casing. The first object of this study is to comprehend a noise property of the blower through the noise test. And, second object is to bring up the method that can reduce blower noise.

A Study on the Power Supply using Soft-switching Dual TTFC Pre-regulator (소프트 스위칭 Dual TTFC Pre-regulator를 사용한 전원장치에 관한 연구)

  • Lee, Dong-Hyun;Kim, Yong;Eom, Tae-Min;Lee, Kyu-Hoon;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1009_1010
    • /
    • 2009
  • This paper presents a power supply system with pre-regulator using zero voltage switching (ZVS) interleaving two-transistor forward converter for high input voltage and high power application. A SMPS has a advantage that a good efficiency, small size and light weight but has a noise problem. A linear power supply system has a advantage that a good stability, low ripple and noise but has a disadvantage that a big size, low efficiency and heat problem. To alleviate these problems, we propose an power supply system using dual ZVS interleaving two-transistor forward pre-regulator. The proposed converter is verified on a 1kW, 50kHz experimental prototype.

  • PDF

Development of the Driving Pump for the Low Noise Large Cavitation Tunnel (저소음 대형 캐비테이션 터널 구동 펌프 개발)

  • Ahn, Jong-Woo;Kim, Gun-Do;Kim, Ki-Sup;Lee, Jin-Tae;Seol, Han-Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.4
    • /
    • pp.370-378
    • /
    • 2008
  • It is reported to develop the driving pump for the Low Noise Large Cavitation Tunnel(LOCAT) which is under construction at Maritime & Ocean Engineering Research Institute(MOERI). For low background noise condition of the LOCAT, it is crucial not only the best pump efficiency but also no cavity occurrence at any operating conditions. Design condition of the pump is determined by considering the required pump headrise, flow quantity, shaft rotation velocity and pump diameter. Performance analysis of the pump is conducted using commercial CFD codes ($BladeGen^+$, CFX-10), and the predicted results are verified by a series of model tests. Cavity was not observed at any operating condition in the model test, which were conducted at the midium cavitation tunnel of MOERI. The optimum pump for LOCAT, named as LP-11, was successfully developed through a series of pump design processes composed of blade design, performance analysis and model test.

A Study of the Benefit Cost of The Railway Nosie (철도소음의 편익비용 추정)

  • Park, Byung-Eun;Jang, Bong-Hee;Han, Sung-Woo;Kim, Dong-Gi;Park, Kwang-Heyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1465-1468
    • /
    • 2006
  • Railway is superior to the other land transportation systems in aspects of environmental problems. Environmental problems are not considered during a preliminary feasibility study. Investment for railway is low because of low B/C(benefit/cost)ratio in the economical efficiency analysis during the preliminary feasibility study. The body of this paper studies the railway noise which can reflect environmental problems an assessment of environmental impact. The body of this paper studies the presumption of The Benefit Cost of railroad noise arresting it will be able to reflect the evaluation environmental matter of the effect which it gives to an environment.

  • PDF

The Operation Characteristics of Domestic Stirling Engine Cogeneration System (가정용 스털링엔진 열병합발전시스템 운전특성에 관한 연구)

  • Choi, Jae-Joon;Park, Byung-Sik;Jung, Dae-Heon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.309-314
    • /
    • 2009
  • The unpredicted worldwide oil price makes the energy efficiency technology be more importance than any other period. The small cogeneration system is one of the most representative technology among the energy efficiency technologies, and the Stirling engine cogeneration system has been concerned and investigated due to the preferable characteristics - low toxic emission, low noise and vibration level, and the various form of fuel. A tiny, 1kW of electrical output, gas fueled Stirling engine cogeneration system was investigated. The electrical efficiency and thermal efficiency of the system were measured. The experiment was executed at an independent Stirling engine mode, independent secondary burner mode, and the combined mode. Part load characteristics of the Stirling engine cogeneration system were investigated also. With the efficiency characteristics, the $O_2$ and NOx emission characteristics were measured.

  • PDF

High Efficiency Bridgeless Power Factor Correction Converter With Improved Common Mode Noise Characteristics (우수한 공통 모드 노이즈 특성을 가진 브릿지 다이오드가 없는 고효율 PFC 컨버터)

  • Jang, Hyo-Seo;Lee, Ju-Young;Kim, Moon-Young;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.85-91
    • /
    • 2022
  • This study proposes a high efficiency bridgeless Power Factor Correction (PFC) converter with improved common mode noise characteristics. Conventional PFC has limitations due to low efficiency and enlarged heat sink from considerable conduction loss of bridge diode. By applying a Common Mode (CM) coupled inductor, the proposed bridgeless PFC converter generates less conduction loss as only a small magnetizing current of the CM coupled inductor flows through the input diode, thereby reducing or removing heat sink. The input diode is alternately conducted every half cycle of 60 Hz AC input voltage while a negative node of AC input voltage is always connected to the ground, thus improving common mode noise characteristics. With the aim to improve switching loss and reverse recovery of output diode, the proposed circuit employs Critical Conduction Mode (CrM) operation and it features a simple Zero Current Detection (ZCD) circuit for the CrM. In addition, the input current sensing is possible with the shunt resistor instead of the expensive current sensor. Experimental results through 480 W prototype are presented to verify the validity of the proposed circuit.

Transmission Loss and Back-pressure Analysis for Inner-separated Muffler (내부 분할된 단순확장관의 투과손실 및 배압 전산해석)

  • Jeong, Weuibong;Kim, Yeon Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.687-689
    • /
    • 2014
  • This paper deals with the optimal muffler model by using acoustic analysis and CFD(computational fluid dynamics) analysis. The complicated muffler model could be better noise reduction performance. However, it could be worse affected to back-pressure performance by pressure drop in working fluid. High back-pressure is caused to low system efficiency. Therefore, it is important for the muffler design to consider the pressure drop. The muffler models are changed their partition plate position. Acoustic power transmission loss(TL) and pressure drop of working fluid are calculated by using computational analysis and used to build database for finding their trends. The optimal muffler model in user-interested frequency range could be selected by analyzing this database.

  • PDF

Low-cost Method for Preventing Noise from Urban Excavation Construction (도심 굴착공사에서의 소음 저감방안)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.90-95
    • /
    • 2002
  • Den have been many construction projects in urban n We have a lot of problems which have to be solved especially against residence complaints existing building damage due to construction worts. We sometimes have to pay a certain amount of cost to solve the above problem, not in planning. In addition to, we have to suffer from work delay due to confronting problem. Almost all of these are due to blasting work to break solid rock to be excavated. Therefore, this study is focused on finding out how to reduce noise more cheaply. Four cases(4) as cheaper but more effective way have been tested to find out which way of local fence will have better moise reduce function in a field site. Where five(5) large breakers are being operated. It is concluded that more form and shape of local movable panel than the site of panel can be influenced on noise reduce.

NOISE CHARACTERISTICS OF SIMPLIFIED FORWARD-TYPE RESONANT CONVERTER

  • Higashi, Toru
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.559-562
    • /
    • 2000
  • The problem of noise generation due to PWM switched-mode power converter has been widely noticed from the viewpoint of Electromagnetic Interference(EMI). Many kings of topologies for resonant converters have been developed both to overcome this noise problem and to attain high power efficiency. It is reported in references that resonant converters which are derived from PWM converter using resonant switch show much lower noise characteristics than PWM converter, and that current-mode resonant converter is more sensitive to stored charge in rectifying diode than voltage-mode counterpart concerning surge generation at diode’s turn-off. On the other hand, above mentioned resonant converters have defect of high-voltage stress on semiconductor switch and complicated circuit configuration. Hence, the simplified Forward-type resonant converter has been proposed and investigated due to its prominent features of simplicity of circuit configuration, low voltage stress and high stability. However, its noise characteristics still remain unknown. The purpose of this paper is to study quantitatively the noise characteristics of this simplified Forward-type resonant converter by experiment and analysis. The influence of parasitic elements and stored charge in rectifying diode on noise generation has been clarified.

  • PDF