• Title/Summary/Keyword: and cyclone

Search Result 552, Processing Time 0.031 seconds

Production of Carbonized Rice Husks by a Cyclone Combustor(I) (사이클론 연소기를 이용한 탄화왕겨의 제조(I))

  • 고길표;노수영
    • Journal of Biosystems Engineering
    • /
    • v.23 no.1
    • /
    • pp.13-20
    • /
    • 1998
  • Carbonized rice husk(char from rice husk) can be used to improve soils for planting, seedlings, horiculture, pomiculture and truck gardening. Although it is not a fertilizer in nature, it stimulates the growth of plants. Carbonized rice husk is highly recommended for raising soil/water temperature, keeping moisture and aerating roots of plants. The objective of this study was to develop the effective production method of carbonized rice husks by a non-slagging vertical cyclone combustor. A cyclone combustor w vortex collecor Pocket in addition to central collector pocket was selected and tested. Isothermal tests and mixed firing with LPG and rice husk were performed in order to characterize the system. hut rice husk was used during the isothermal test to find the mass collected of rice husk. It was impossible to ignite rice husk itself over the experimental conditions considered in this experiment. The composition of original and carbonized rice husks was analyzed by the ultimate analysis. With the air flow rate of 20 ㎥/h, LPG flow rate of 0.45 1/min, the required carbonized rice husk could be obtained.

  • PDF

Observed characteristics of tropical cyclone vertical wind profiles

  • Giammanco, Ian M.;Schroeder, John L.;Powell, Mark D.
    • Wind and Structures
    • /
    • v.15 no.1
    • /
    • pp.65-86
    • /
    • 2012
  • Over the last decade substantial improvements have been made in our ability to observe the tropical cyclone boundary layer. Low-level wind speed maxima have been frequently observed in Global Positioning System dropwindsonde (GPS sonde) profiles. Data from GPS sondes and coastal Doppler radars were employed to evaluate the characteristics of tropical cyclone vertical wind profiles in open ocean conditions and at landfall. Changes to the mean vertical wind profile were observed azimuthally and with decreasing radial distance toward the cyclone center. Wind profiles within the hurricane boundary layer exhibited a logarithmic increase with height up to the depth of the wind maximum.

Simultaneous Control of Dust and Gases Using a Double Centrifugal Device (이중 원심력 집진장치를 이용한 분진-가스 동시 처리)

  • Jang, Jung-Hee;Lee, Ju-Heon;Jo, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.336-345
    • /
    • 2008
  • A large volume of work has been attempted to improve the separation efficiency of cyclone by establishing new design and optimum operation. An auxiliary device called Post Cyclone (PoC) has been introduced and tested in an earlier work (In order to reduce the emission of fine dust from the reverse flow cyclones). This work applies the PoC to remove the dust and gaseous elements using a centrifugal effect remained in the discharging flow over the cyclone. As a result of the experiment, the efficiency was found best at the high gas concentration and low inlet velocity.

Numerical Study on the Effect of the Internal Temperature Distribution in the Cyclone Dust Collector (사이클론 집진장치의 내부 온도 변화에 따른 집진효율에 관한 전산해석적 연구)

  • Hyun, Daegeun;Cha, Hyuksang
    • Particle and aerosol research
    • /
    • v.10 no.4
    • /
    • pp.155-162
    • /
    • 2014
  • The internal temperature will change depending on operation conditions and material of cyclone dust collector. This study compares the results of collection efficiency and temperature distribution on the different heat flux at wall of dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $600^{\circ}C$. Because of the difference of outer vortex and inner vortex temperature, the collection efficiency will reduce with the increase of heat flux, showed the highest collection efficiency at heat insulation.

Comparison of PM2.5 Concentrations by Measurement Method (측정 방법에 따른 PM2.5 농도 비교)

  • Ghim, Young Sung;Choi, Yongjoo;Park, Jisoo;Kim, Pilho;Han, Yu Kyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.5
    • /
    • pp.515-520
    • /
    • 2017
  • $PM_{2.5}$ concentrations were measured using a cyclone, impactor (the U.S. Environmental Protection Agency well impactor ninety-six, WINS) and optical particle counter (OPC) at a campus site located in Yongin for the period August 2014 through March 2017. The concentrations from cyclone (Y) were generally higher than those from impactor(X); the best-fit line was Y=1.22X+5.64. The ratios of $PM_{2.5}/PM_{10}$ ranged from 0.61 to 0.66 when $PM_{2.5}$ concentrations from cyclones in selected studies were converted into those from impactors using a regression equation in this study. The slope of the best-fit line between OPC and impactor was close to 1 at 0.95, while that between OPC and cyclone was 0.72. After sampling, the flow rate in the low-volume air sampler with cyclone decreased by 3% on average, which did not have a significant effect on measured concentrations.

A Numerical Analysis on Prediction of Cut-diameter according to Vane Outflow Angle in the Axial-flow Cyclone (축상유입식 사이클론의 베인 유출각도에 따른 절단입경 예측에 관한 수치해석)

  • Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.111-117
    • /
    • 2012
  • Dust collecting performance of axial-vane type cyclone for oil mist was analyzed in this study. For predicting cut diameter size of cyclone, the number and angle of vane ($tan{{\beta}_2}^{\prime}$) was simulated by CFD. As the result, $tan{{\beta}_2}^{\prime}$ was decreased as the number of vane was increased and the angle of inclination(${{\beta}_2}^{\prime}$) decreased, and it cause strong swirl flow. Therefore, it could be confirmed that as the number of vane was increased and the angle of inclination was decreased, cut diameter size was decreased. Also, by verifying the results of CFD through experiment, the cut diameter size could be $2{\mu}m$ at $4m^3/min$ of flow rate.

A Study on Dust Collection Efficiency of Axial-vane Type Cyclone for Oil Mist (오일미스트용 축상 유입식 사이클론의 집진효율에 관한 연구)

  • Yi, Chung-Seob;Shin, Hae-Joong;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.415-420
    • /
    • 2012
  • Dust collecting performance of axial-vane type cyclone for oil mist was analyzed in this study. For predicting cut diameter size of cyclone, the number and angle of vane (${\beta}_2{^{\prime}}$) was calculated by CFD. As the result, ${\beta}_2{^{\prime}}$ was decreased as the number of vane was increased and the angle of inclination (${\beta}_2{^{\prime}}$) decreased, and it cause strong swirl flow. Therefore, it could be confirmed that as the number of vane was increased and the angle of inclination was decreased, cut diameter size was decreased. Also, by verifying the results of CFD through experiment, the cut diameter size could be 2 ${\mu}m$ at 4 $m^3/min$ of flow rate.

A Study on Effects of Operating Temperatures of Cyclone on Pressure Drop (사이클론의 작동온도가 압력손실에 미치는 영향에 관한 연구)

  • Kwak, Ji-Young;Song, Myung-Jun;Lee, Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.515-519
    • /
    • 2012
  • A numerical study was performed to observe the relation between internal flow characteristics and operating temperatures in a Lapple cyclone. The present numerical results agree reasonably well with previous experimental and numerical results. As the operating temperature increases, the pressure drop decreases due to decrease of wall shear stress and tangential velocities. A detailed comparison of pressure drops in the cyclone between theoretical prediction models and the present numerical simulations is also presented for wide range of operating temperatures.

  • PDF

De-entrainment of Boron by Evaporation. (증발에 따른 붕소의 탈비말 동반)

  • Lee, Hoo-Kun;Chun, Kwan-Sik;Park, Hyun-Soo;Suh, In-Suk
    • Nuclear Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.261-266
    • /
    • 1986
  • The purpose of this research was to investigate the de-entrainment of boron for evaporators used in nuclear power plants. The forced circulation and semi-continuous type evaporator was used in the experiment. Cyclone and glass-wool packed column which is supposed to provide good decontamination factor as well as easy maintenance, were selected as de-entrainment devices to be used in the evaporation of radioactive liquid wastees. The de-entrainment device combined with cyclone and glass-wool column has shown overall DF more than 1, 000 for boron.

  • PDF

A Study on Low Emission Pulverized Coal Combustion in the 2 Staged Coaxial Cyclone Combustor (2단 동축형 Cyclone 연소기를 이용한 저공해 미분탄 연소특성 연구)

  • Choi, Sang-Il;Park, Chu-Sik;Kim, Sung-One;Kim, Ho-Young
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.1
    • /
    • pp.67-83
    • /
    • 1999
  • The objective of this study is development of low emission pulverized coal combustor for reducing pollutant emission generated from coal combustion. Low emission combustion technology for reducing NOx and fly ash was investigated by using 2 stage coaxial cyclone combustor. Staged combustion was employed for NOx reduction and high temperature slagging combustion was also studied for fly ash removal in the combustor. The result of this study shows that the low emission combustion system can reduce the amount of atmospheric pollutions with improved boiler efficiency and performance.

  • PDF