• 제목/요약/키워드: and Simulation

Search Result 68,373, Processing Time 0.103 seconds

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Development of Unfolding Energy Spectrum with Clinical Linear Accelerator based on Transmission Data (물질투과율 측정정보 기반 의료용 선형가속기의 에너지스펙트럼 유도기술 개발)

  • Choi, Hyun Joon;Park, Hyo Jun;Yoo, Do Hyeon;Kim, Byoung-Chul;Yi, Chul-Young;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • Background: For the accurate dose assessment in radiation therapy, energy spectrum of the photon beam generated from the linac head is essential. The aim of this study is to develop the technique to accurately unfolding the energy spectrum with the transmission analysis method. Materials and Methods: Clinical linear accelerator and Monet Carlo method was employed to evaluate the transmission signals according to the thickness of the observer material, and then the response function of the ion chamber response was determined with the mono energy beam. Finally the energy spectrum was unfolded with HEPROW program. Elekta Synergy Flatform and Geant4 tool kits was used in this study. Results and Discussion: In the comparison between calculated and measured transmission signals using aluminum alloy as an attenuator, root mean squared error was 0.43%. In the comparison between unfolded spectrum using HEPROW program and calculated spectrum using Geant4, the difference of peak and mean energy were 0.066 and 0.03 MeV, respectively. However, for the accurate prediction of the energy spectrum, additional experiment with various type of material and improvement of the unfolding program is required. Conclusion: In this research, it is demonstrated that unfolding spectra technique could be used in megavoltage photon beam with aluminum alloy and HEPROW program.

Characteristics of Mass Transport Depending on the Feature of Tidal Creek at Han River Estuary, Gyeong-gi Bay, South Korea (경기만 염하수로에서의 비정규 격자 수치모델링을 통한 조간대 조수로의 고려에 따른 Mass Transport 특성)

  • Kim, Minha;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.41-51
    • /
    • 2013
  • The tidal creek dependent mass transport characteristic in Gyeong-Gi Bay (west coast of Korea) was studied using field measured data and numerical model. Gyeong-Gi Bay consists of 3 main tidal channels and contains a well-developed vast tidal flat. This region is famous for its large tidal difference and strong current. We aim to study the effect of tidal creek in the tidal flat on the mass exchange between the estuary and the ocean. For numerical application, the application of unstructured grid feature is essential, since the tidal creek has complicated shape and form. For this purpose, the FVCOM is applied to the study area and simulation is performed for 2 different cases. In case A, geographic characteristics of the tidal creek is ignored in the numerical grid and in case B, the tidal creek are constructed using unstructured grid. And these 2 cases are compared with the field measured cross-channel mass transport data. The cross-channel mass transport at the Yeomha waterway mouth and Incheon harbor was measured in June, 9~10 (Spring tide) and 17~18 (Neap tide), 2009. CTD casting and ADCP cross-channel transect was conducted 13 times in one tidal cycle. The observation data analysis results showed that mass transport has characteristic of the ebb dominance Line 1 (Yeomha waterway mouth), on the other hand, a flood dominant characteristic is shown in Line 2 (Incheon harbor front). By comparing the numerical model (case A & B) with observation data, we found that the case B results show much better agreement with measurement data than case A. It is showed that the geographic feature of tidal creek should be considered in grid design of numerical model in order to understand the mass transport characteristics over large tidal flat area.

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

A Quality Assurance Study for the Application of Cook/chill System in School Foodservice Operation (I) - Broiled Spanish Mackerel - (학교급식에 Cook/chill system 적용을 위한 품질보증연구(I) - 삼치구이 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.278-293
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point-based standardized recipe applicable to cook/chilled Broiled Spanish Mackerel in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. HACCP for the production of menu items was identified in simulation study. At each critical control point, time-temperature profile was recorded and microbiological analysis was done. Also chemical analyses and sensory evaluation were conducted for 5 days of chilled storage. The results of time-temperature measurement of Broiled Spanish Mackerel by each production phase showed satisfactory condition that met the standards. Broiled Spanish Mackerel showed excellent microbiological quality from raw ingredient phase ($TPC:2.58{\pm}0.12\;Log\;CFU/g$) to holding phase ($TPC:2.70{\pm}0.42\;Log\;CFU/g$). Coliform (0.84 Log MPN/g) and fecal coliform (0.84 Log MPN/g) were detected from marinating phase ($TPC:3.82{\pm}0.52\;Log\;CFU/g$). After heating, only few mesophiles were detected ($TPC:1.83{\pm}0.49\;Log\;CFU/g$). No psychrophiles, coliforms and fecal coliforms were detected. In the phases after rapid chilling, during chilled storage and after reheating and distribution, almost none of the above microbes were detected. Salmonella and Listeria monocytogenes were not detected in all production phases. The pH immediately after cooking was 6.65 and then increased significantly to 6.81 on the third day of chilled storage (p<0.001). Acid value did not show significant changes while total volatile based nitrogen (TVBN) dramatitically increased during storage periods (p<0.01). In the result of sensory evaluation, general acceptability points had been rated high in the first day of storage, and then, the points were decreased significantly on the third day (p<0.05). General acceptability points ranged from 8.86 to 10.68. Accordingly, Broiled Spanish Mackerel is highly recommendable cook/chill system. Considering the DHSS standards for storage, the ideal shelf-life recommended for Broiled Spanish Mackerel is within 4 days excluding cooking day. For Broiled Spanish Mackerel, critical control points were purchasing and receiving of frozen Spanish Mackerel, heating, chilling, chilled storage, reheating and distribution.

  • PDF

A Case Study On Digital Education Design In Foreign Countries By Analysis Education Condition (선진학교 교육현황 분석을 통한 디지털 교육매체 디자인 국외 사례 연구)

  • Kim, Jung-Hee
    • Cartoon and Animation Studies
    • /
    • s.30
    • /
    • pp.201-219
    • /
    • 2013
  • Development of digital media in education field at America, UK, Japan etc bring big progress on digital device if education. Japan bring huge progress on digital education by nationally. UK use huge a national budget at digital education development and Sweden which is advanced country of education and a welfare state. Especially UK and Sweden's digital education markets are full now aspect more high quality design. Korea which is advanced country of IT adopted digital text book 2007 with mathematics, through science and English digital text book through the state. Korea's digital text book is in a transition period. that needs case study of advanced country of education for setting design guide and educational effect to digital education media and device plan. All researches are based on LG europe design center at London. Analysis by using KJ method, survey of questionnaire, heuristic method at 4 schools in UK and Sweden. Through analytical researches want to more reality simulation at digital education, and high quality contents with digital socialization. co-work with analog, can get any where, anytime user want without any difficulty. Also interactive GUI design of digital education device to easy to access for user. When plan Digital text book content and design needs methodical design guide for target who students and environment an in-depth study of the appraisal and method. The results of the research are introduce the design plan as a basic research and giving useful design plan to make digital educational media in Korea industrial aspect.

Probabilistic Exposure Assessment of Pesticide Residues in Agricultural Products in Gyeonggi-do (경기도내 유통 농산물 중 잔류농약의 확률론적 노출평가 연구)

  • Do, Young-Sook;Kim, Jung-Boem;Kang, Suk-Ho;Kim, Nan-Young;Eom, Mi-Na;Yoon, Mi-Hye
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.117-125
    • /
    • 2013
  • A probabilistic exposure assessment was performed on the monitoring data of pesticides were assessed in agricultural products in Gyeonggi-do from 2006 to 2010. Chlorothalonil, chlorpyrifos, dicofol, endosulfan, EPN, ethoprophos, fenitrothion, methidathion, phenthoate and tebupirimfos were assessed. For this assessment, we used Monte Carlo simulation software and the distribution of concentration and intake were assumed to lognormal distribution by inputting mean and standard deviation. The hazard index (HI, %ADI) of average value and the $95^{th}$ percentile based on a probabilistic method were usually lower than those by a deterministic one. For the whole population, when non-detects data were assigned 0 mg/kg, HI of the average value and the $95^{th}$ percentile showed 0.05~0.70% and 0.11~1.94%, respectively. When nondetects data were assigned 0.005 mg/kg, HI of the average value and the $95^{th}$ percentile were 0.41~4.42% and 0.98~13.81%. For only consumers, when non-detects data were assigned 0 mg/kg, HI of the average value and the $95^{th}$ percentile were 1.24~10.16% and 3.72~33.81%, respectively. When non-detects data were assigned 0.005 mg/kg, HI of the average value and the $95^{th}$ percentile were 3.43~18.26% and 9.45~54.99%, respectively. Methidathion had highest values when both of 0 and 0.005 were assigned to non-detecs data for consumers only. This study showed that agricultural products in Gyeonggi-do were safe because they had less than 100 of HI (%ADI) based on probabilistic exposure assessment.

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

A Multi-agent System to Assess Land-use and Cover Changes Caused by Forest Management Policy Scenarios (다행위자시스템을 이용한 산림정책별 토지이용 변화와 영향 분석)

  • Park, Soojin;An, Yoo Soon;Shin, Yujin;Lee, Sooyoun;Sim, Woojin;Moon, Jiyoon;Jeong, Gwan Young;Kim, Ilkwon;Shin, Hyesop;Huh, Dongsuk;Sung, Joo Han;Park, Chan Ryul
    • Journal of the Korean Geographical Society
    • /
    • v.50 no.3
    • /
    • pp.255-276
    • /
    • 2015
  • This paper presents a multi-agent system model of land-use and cover changes, which is developed and applied to the Gariwang-san and its vicinity, located in Pyeongchang and Jeongseon-gun, Gangwon province, Korea. The Land Use Dynamics Simulator (LUDAS) framework of this study is well suited for representing the spatial heterogeneity and dynamic interactions between human and natural environment, and capturing the impacts of forest-opening policy interventions to future socio-economic and natural environment changes. The model consists of four components: (1) a system of human population, (2) a system of landscape environment, (3) decision-making procedures integrating human(or household), environmental and policy information into forest land-use decisions, and (4) a set of policy scenarios that are related to the forest-opening. The results of model simulation by different combination of various forest management scenarios are assessed by the levels of household income, ecosystem service value and income inequality in the study region. As a result, the optimal scenario of forest-opening policies in the study region is to open the forest to local residential community for the purpose of recreation, considering the distinctive topographical feature. The model developed in this research is expected to contribute to a decision support system for sustainable forest management and various land-use policies in Korea.

  • PDF