• 제목/요약/키워드: anchorage zone

검색결과 69건 처리시간 0.025초

A Mechanical Model of the End Anchorage Zone of Prestressed Concrete Members

  • Kang, Won-Ho;You, Young-Min;Oh, Seung-Hyun;Lee, Sang-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.35-41
    • /
    • 2006
  • It is expected that recent development of mechanical models will soon supersede previous empirical methods of detailing. In this study, a mechanical model is proposed to analyze the behavior of the anchorage zone of prestressed concrete members. The main characteristics of the proposed model lies in its rational consideration of material properties such as concrete strength in biaxial stress state and that of local zone reinforced by spirals. The shear friction strength of concrete surrounding a spiral is also considered. The computational results of the proposed model as well as the existing Strut-and-Tie model(STM) and nonlinear finite element analysis are compared with experimental results. The results of the comparison revealed that the proposed model showed better prediction of the failure mode as well as the failure load. Additionally, the proposed model also explained the three-dimensional failure mechanism very well, while other methods based on two-dimensional analysis could not do so well.

2,400 MPa 강연선용 포스트텐션 정착구의 하중전달성능 (The Load Transfer Performance of Post-tension Anchorage with 2,400 MPa Strands)

  • 김선우;노병철;임정훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.63-71
    • /
    • 2018
  • 인장강도가 2,400 MPa인 강연선이 개발되어 콘크리트구조기준 및 KS 규격에 반영되었다. 고강도 프리스트레스트 강연선이 구조물에 적용되기 위해서는 그에 적합한 정착시스템이 함께 사용되어야 한다. 최근에 2,400 MPa 강연선 적용을 위한 포스트텐션 정착구의 개발이 진행되어왔으나, 성능평가에 대한 연구가 미비한 실정이다. 따라서 본 연구에서는 2,400 MPa 강연선을 적용한 포스트텐션 정착구 중 가장 활용도가 높은 9 가닥, 15 가닥, 19 가닥 정착구에 대하여 PTI의 Anchorage Design Zone에 의한 국소구역 구조검토를 실시하였고, ETAG013 및 KCI-PS101에 의한 하중전달성능평가를 수행하였다. 또한 비선형 수치해석을 통해 시험의 적절성을 분석하였다. 그 결과, 2,400 MPa 정착구는 국소구역의 구조성능을 만족하고, 하중전달성능 조건을 만족하는 것으로 나타났다.

원형 정착구를 적용한 프리스트레스트 콘크리트 정착구역의 파열력에 관한 연구 (Study on Bursting Stress in Anchorage Zone of Prestressed Concrete Using Circular Anchorages)

  • 최규형;노병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.3-12
    • /
    • 2015
  • 포스트텐션 공법의 파열력 계산은 탄성이론을 기반으로 한 Guyon의 제안식이 널리 활용되고 있다. Guyon의 파열력 계산식은 프리스트레스 힘과 콘크리트 단면 길이에 대한 정착판 단면 길이의 비가 주요 변수 이다. Guyon이 제시한 파열력 계산 방법은 사각형 정착판이 적용된 정착구를 기준으로 하고 있으나, 원형 정착구에 대해서도 그대로 적용하고 있다. 또한 Guyon은 정착구역에서 발생하는 복잡한 응력을 2차원으로 단순화하였다. 따라서 본 연구에서는 원형 정착구에 적용 가능 한 파열력 계산식을 제안하기 위하여 기존 이론의 분석과 정착구역에서 발생하는 응력에 대해 3차원 분석을 수행하였다. 기존의 파열력 계산식을 개선한 원형 정착구의 파열력 계산식을 제안하였다.

유한요소법 및 유사 3 차원 스트릿-타이 모델 방법을 이용한 PSC 박스거더 정착부의 해석 (Analysis of PSC Box Girder Anchorage Zone using FEM and 2D SUB-3D STM Approach)

  • 윤영묵;김승억;오진우;박정웅
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.113-129
    • /
    • 2000
  • This study evaluates the behavior and strength of an anchorage zone of the prestressed concrete box girder bridge on the Kyungboo highway railroad using the 2D SUB-3D STM approach and a linear elastic finite element analysis. The 2D SUB-3D STM approach utilizes several two-dimensional sub strut-tie models that represent the compressive and tensile stress flows of each projected plane of the three-dimensional structural concrete in the selection of a three dimensional strut-tie model, evaluation of the effective strengths of the concrete struts, and verification of the geometric compatibility condition and bearing capacity of the critical nodal zones in the selected three-dimensional strut-tie model. The finite element analysis uses an 8-node brick element and the longitudinal prestressing force is considered as the equivalent nodal force. Analysis results show that the 2D SUB-3D STM approach and linear elastic finite element method can be effectively applied to the analysis and design of three-dimensional structural concrete including a prestressed concrete box girder anchorage zone.

  • PDF

PSC I 거더의 정착부 파열거동 평가 (Evaluation of Bursting Behavior in Anchorage Zone of PSC I Girders)

  • 최규천;박영하;백인열
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.329-336
    • /
    • 2010
  • 이 논문에서는 경간장이 30 m인 표준 PSC I 거더의 정착부 거동을 평가하기 위한 실험적 연구를 수행하였다. 현재 사용되고 있는 표준 PSC I 거더의 정착부 파열보강철근은 텐던 긴장으로 인한 단부 콘크리트의 응력흐름을 정확히 반영하지 못 한 채 설계되었고, 과대보강으로 인해 콘크리트 타설 시 작업성이 크게 떨어지고 있는 실정이다. 따라서 이 논문에서는 표준 PSC I 거더와 동일한 단면을 갖는 실험체 3개를 제작하여 인장실험을 수행하였다. 각 실험체의 파열보강철근은 100 mm, 200 mm, 300 mm 간격의 격자형으로 배근되었다. 실험결과, 파열균열 긴장력은 모든 실험체에서 설계 긴장력의 1.6배 내외로 나타났고, 파열균열은 정착단부 내부에서 수직방향으로 발생하였다. 또한 설계 긴장력의 2.7배까지 긴장력을 도입한 결과, 파열보강철근 간격이 300 mm인 실험체의 일부 수평방향 파열보강철근만 항복되었다. 따라서 표준 PSC I 거더의 정착부 파열보강철근은 도로교설계기준에서 제한하고 있는 최대 간격 300 mm를 만족시키는 것만으로도 파열력에 대한 안전성을 충분히 확보할 수 있음을 확인하였다.

강재로 구속된 프리스트레스트 콘크리트 합성거더의 강재 정착부 적용을 위한 실험적 고찰 (An Experimental Study for the Application of Steel Anchorage Zone in Steel-Confined Prestressed Concrete Girder)

  • 김정호;이상윤;황윤국;박경훈;오창열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.455-458
    • /
    • 2005
  • The Steel-Confined Prestressed Concrete Girder(SCP Girder) has been developed, which maximizes structural advantages of components (concrete, steel plate and tendon) and can be used to construct the middle or long span bridge with low-height girder. And recently, a continuous beam type of SCP Girder has been being developed to decrease size and self weight of girder in comparison with a simply-supported type. In this study, as part of developing the continuous beam type of SCP Girder, a new type of anchorage zone is proposed in order to address tendons effectively and decrease section size of SCP Girder efficiently. And also, the experimental test was carried out using a real scale specimen to examine the behavior of proposed anchorage zone.

  • PDF

비부착 포스트텐션 정착구역 설계를 위한 파열력 산정 방법 (Bursting Force Equation for Design in Unbonded Post-Tensioned Anchorage Zone)

  • 노경민;이영학
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.21-26
    • /
    • 2018
  • For evaluating equations of bursting force in different codes, comparative study of the formulas was conducted. Because the equations does not consider variables such as shape of anchorages and duct, a relation between the bursting forces and the variables has to be analyzed. In this paper, the bursting forces equation was proposed by finite element analysis. As evaluation through comparison of the proposed equation with the previous ones and an experiment, it was figured out that bursting force computed by the proposed equation could be used for design of reinforcement in the anchorage zone.

PSC 박스거더교 정착부의 최소파열력에 대한 강선긴장순서 (Minimization of Bursting Force at Anchorage Zone Using Prestressing Order for PSC Box Girder Bridge)

  • 정지승;구형선
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.103-109
    • /
    • 2001
  • In this paper, the prestressing order of tendons is studied to minimize a bursting force of an anchorage. The bursting forces is a primary factor of anchorage failures. The forces of the anchorage depend on the prestressing order and size of the tendons, if a lot of tendons are introduced to the anchorage. Many studies have been made to analyze the bursting force of the anchorage. However, the studies have been limited to the bursting forces of the anchorage having one or two tendons. PSC box girder bridges usually have a lot of tendons. And the difference of the bursting forces lies in the prestressing order of the tendons. As a result of the lack of studies on the prestressing order for the bridges, the order depends on the designer's intuition and experiences. It may be stated that this study should be useful for determining the reasonable prestressing order of tendons for the PSC box girder bridges.

  • PDF

원형 정착판을 사용한 포스트텐션 특수정착구의 설계에 관한 연구 (A Study on the Design of Special Circular Plate Anchorage for Post-tension)

  • 최규형;노병철;임정훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권6호
    • /
    • pp.73-83
    • /
    • 2016
  • 포스트텐션 공법을 적용한 콘크리트 부재의 정착구역에서 정착판 근처의 지압응력은 일반적으로 높은 프리스트레스 하중에 의해 발생한다. 따라서 단면의 효율적인 활용과 콘크리트 부재의 파괴로 이어질 수 있는 균열제어를 위해 적절한 정착판의 크기가 제시되어야 한다. 본 연구에서는 도로교설계기준 및 PTI 등에 의해 사각형 정착판과 원형 정착판의 유효면적에 대한 관계식을 제안하였다. 또한 정착판의 형상에 따라 형상계수를 제안하였으며, 유한요소해석을 통해 적절성을 분석하였다.

비부착식 단일 강연선용 원형 정착구의 일방향 슬래브 적용에 관한 실험적 연구 (An Experimental Study on the Performance of One-Way Slab Using Unbonded Post-Tensioned Anchorage for Single Tendon)

  • 김민숙;노경민;이영학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.45-51
    • /
    • 2019
  • In this study, the static load test and the load transfer test were carried out to evaluate the structural performance of the circular anchorage proposed by the previous study. Specimens were fabricated according to KCI-PS101 and ETAG 013. As a result of the static load test, it was verified that the displacement of the wedge and the strand was kept constant when the tensile force of 80% of the nominal strength of the strand was applied. In the load transfer test, it was confirmed that all the specimens satisfied the stabilization formula of KCI-PS101 and ETAG 013. Post-tensioned one-way slab with circular anchorage were fabricated to evaluate the flexural behavior. All specimens exhibited the same flexural behavior and maximum load. However, the specimen with circular anchorage were advantageous than the rectangular anchorage one in terms of crack control of the anchorage zone.