• Title/Summary/Keyword: anchorage change

Search Result 56, Processing Time 0.026 seconds

Evaluate Anchorage Strength of High Relative Rib Area Bars Using Hook Test Specimens (갈고리 시험체를 이용한 높은마디면적 철근의 정착성능)

  • Seo Dong Min;Hong Gi Suop;Choi Dong Uk;Choi Oan Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.327-330
    • /
    • 2005
  • Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force in practice has a limitation. Thus, the only variable is the bearing area corresponding to the change of bond force. In this study, to the evaluate anchorage strength of high relative rib area bars, hook bond test specimens are tested and the results are discussed. Higher rib height bars when bars are confined showed higher anchorage strength than lower rib higher bars.

  • PDF

Dynamic Characteristics of Cable-Stayed Anchorage considering Cracks at Bolt and Welding Connection (용접 및 볼트 연결부 균열을 고려한 사장교 케이블 정착부의 동특성 해석)

  • Kim, Chul Young;Kim, Sung Bo;Jung, Woo Tai
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.4 s.41
    • /
    • pp.351-362
    • /
    • 1999
  • Damage detection methods which utilize the change in dynamic characteristics are very hard to apply to large civil structures since local damage hardly affects global dynamic characteristics. But, if there is a very important and critical member and we focus only on the local behavior of it, it would be possible to detect damage from the change in local dynamic characteristics, such as natural frequencies and mode shapes .In this study, the cable anchorage part of a cable-stayed bridge under construction is modeled and analyzed by commercial finite element program, ABAQUS. It has both welding and bolting connections with a cable and a stiffening plate, and has a possible high stress concentration portions in it. Several damage scenarios such as crack through the welding or crack through the bolting connection are examined. The result shows that the local natural frequencies of the damaged member decrease up to 16% compared with that of the undamaged member. It is concluded that there is quite a high feasibility that the damage of the cable anchorage can be detected by measuring local dynamic characteristics.

  • PDF

Three-dimensional evaluation of tooth movement in Class II malocclusions treated without extraction by orthodontic mini-implant anchorage

  • Ali, Dler;Mohammed, Hnd;Koo, Seung-Hwan;Kang, Kyung-Hwa;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.280-289
    • /
    • 2016
  • Objective: The aim of this study was to analyze tooth movement and arch width changes in maxillary dentition following nonextraction treatment with orthodontic mini-implant (OMI) anchorage in Class II division 1 malocclusions. Methods: Seventeen adult patients diagnosed with Angle's Class II division 1 malocclusion were treated by nonextraction with OMIs as anchorage for distalization of whole maxillary dentition. Three-dimensional virtual maxillary models were superimposed with the best-fit method at the pretreatment and post-treatment stages. Linear, angular, and arch width variables were measured using Rapidform 2006 software, and analyzed by the paired t -test. Results: All maxillary teeth showed statistically significant movement posteriorly (p < 0.05). There were no significant changes in the vertical position of the maxillary teeth, except that the second molars were extruded (0.86 mm, p < 0.01). The maxillary first and second molars were rotated distal-in ($4.5^{\circ}$, p < 0.001; $3.0^{\circ}$, p < 0.05, respectively). The intersecond molar width increased slightly (0.1 mm, p > 0.05) and the intercanine, interfirst premolar, intersecond premolar, and interfirst molar widths increased significantly (2.2 mm, p < 0.01; 2.2 mm, p < 0.05; 1.9 mm, p < 0.01; 2.0 mm, p < 0.01; respectively). Conclusions: Nonextraction treatment with OMI anchorage for Class II division 1 malocclusions could retract the whole maxillary dentition to achieve a Class I canine and molar relationship without a change in the vertical position of the teeth; however, the second molars were significantly extruded. Simultaneously, the maxillary arch was shown to be expanded with distal-in rotation of the molars.

Application of dental implant for orthodontic anchorage (보철 수복용 임플란트의 교정치료를 위한 고정원의 활용)

  • Kang, Hyo-Jin;Park, Eun-Jin;Kim, Sun-Jong;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.6
    • /
    • pp.404-413
    • /
    • 2016
  • Currently, dental implants have become predictable and reliable adjuncts for oral rehabilitation. Osseointegrated implants can be used to provide rigid orthodontic anchorage and have advantages compared conventional orthodontic anchorage especially when there were edentulous areas and implants were scheduled as a treatment plan. Orthodontic force doesn't cause the bone loss of osseointegrated implants. Implant materials, surgical protocols and healing time before loading follow the conventional treatment protocol. Because the implants, once installed, can't change the location, meticulous treatment planning should be preceded. Further investigations are needed to standardize the treatment protocol.

  • PDF

An electromechanical impedance-based method for tensile force estimation and damage diagnosis of post-tensioning systems

  • Min, Jiyoung;Yun, Chung-Bang;Hong, Jung-Wuk
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.107-122
    • /
    • 2016
  • We propose an effective methodology using electromechanical impedance characteristics for estimating the remaining tensile force of tendons and simultaneously detecting damages of the anchorage blocks. Once one piezoelectric patch is attached on the anchor head and the other is bonded on the bearing plate, impedance responses are measured through these two patches under varying tensile force conditions. Then statistical indices are calculated from the impedances, and two types of relationship curves between the tensile force and the statistical index (TE Curve) and between statistical indices of two patches (SR Curve) are established. Those are considered as database for monitoring both the tendon and the anchorage system. If damage exists on the bearing plate, the statistical index of patch on the bearing plate would be out of bounds of the SR curve and damage can be detected. A change in the statistical index by damage is calibrated with the SR curve, and the tensile force can be estimated with the corrected index and the TE Curve. For validation of the developed methodology, experimental studies are performed on the scaled model of an anchorage system that is simplified only with 3 solid wedges, a 3-hole anchor head, and a bearing plate. Then, the methodology is applied to a real scale anchorage system that has 19 strands, wedges, an anchor head, a bearing plate, and a steel duct. It is observed that the proposed scheme gives quite accurate estimation of the remaining tensile forces. Therefore, this methodology has great potential for practical use to evaluate the remaining tensile forces and damage status in the post-tensioned structural members.

Long Term Behavior of Permanent Rock Anchorages in Large Spatial Span Structures (대공간구조물에 시공된 영구앵커의 장기거동)

  • Yoo, Nam-Jae;Kim, Dae-Hak;Park, Byung-Soo;Kim, Jae-Il;Lee, Jong-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.123-135
    • /
    • 2006
  • Most of all, large spatial span structures are the symbol of cities but have to get to supply the purpose of structure simultaneously, therefore their foundations are designed to get rolls of structure support, structure shape maintenance or overturn prevention, buoyancy resistance, etc. Accordingly various type foundations have been introduced, and after anchorage power is introduced for double structures shape maintenance and overturn prevention, change of anchorage power checked in the construction process is reviewed, comparing of playground case. Case1 anchors for the control of horizontal power worked outside hemisphere type roof, Case2 anchors for the overturn prevention of cantilever roof examined in this example. The examination has been executed by the analysis of anchorage power introduction process, related test results and anchorage power monitoring results for 2 examples.

Characteristic of hull motion due to external forces at anchor (묘박 중 외력에 의한 선체의 운동 특성)

  • Chang-Heon LEE
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.2
    • /
    • pp.135-144
    • /
    • 2023
  • In order to provide basic data to increase the efficiency and stability of seamanship at anchoring, the characteristics of the hull motion including dragging anchor due to external forces were observed at Mokpo and Jinhae anchorage for the avoidance of the typhoon. As a result, it is necessary to check the embedding motion and holding power of the anchor according to at initial position to decrease dragging anchor. Dragging anchor at anchorage seems to have been easily caused according to discrepancy between embedded anchor flukes and the towing direction due to the change in wind direction, rather than the wind speed. This discrepancy, thus, should be considered when anchoring. This test vessel with a small radius of curvature of the stem is relatively vulnerable to the influence of wind direction and wind speed, so it is easy to cause a decrease in the holding power due to an increase in the rate of turn. When the current speed is greater than or equal to 1 knot, the range of the rate of turn is reduced resulting in a relatively increased holding power. In addition, during the swing, the tension of the chain was high according to the angular velocity change of heading at three-quarters of the swing length rather than the left and right ends.

Hybrid vibration-impedance monitoring in prestressed concrete structure with local strand breakage

  • Dang, Ngoc-Loi;Pham, Quang-Quang;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.463-477
    • /
    • 2022
  • In this paper, a hybrid vibration-impedance-based damage monitoring approach is experimentally evaluated for prestressed concrete (PSC) structures with local strand breakage. Firstly, the hybrid monitoring scheme is designed to alert damage occurrence from changes in vibration characteristics and to localize strand breakage from changes in impedance signatures. Secondly, a full-scale PSC anchorage is experimented to measure global vibration responses and local impedance responses under a sequence of simulated strand-breakage events. Finally, the measured data are analyzed using the hybrid monitoring framework. The change of structural condition (i.e., damage extent) induced by the local strand breakage is estimated by changes in a few natural frequencies obtained from a few accelerometers in the structure. The damaged strand is locally identified by tomography analysis of impedance features measured via an array of PZT (lead-zirconate-titanate) sensors mounted on the anchorage. Experimental results demonstrate that the strand breakage in the PSC structure can be accurately assessed by using the combined vibration and impedance features.

A comparison of on masse retraction of six anterior teeth with separate canine retraction (6전치 일괄(on masse) 견인과 견치 견인 후 4전치 견인 시 공간폐쇄 양상에 관한 연구)

  • Heo, Wook;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.165-174
    • /
    • 2002
  • The purpose of this study was to compare on masse retraction of six anterior teeth with separate canine retraction in the amount of the anchorage loss and the retraction of the anterior teeth. The subjects consisted of 30 adult female patients with Angle Class 1 malocclusions who were treated by .022' straight wire appliance with 4 first permolar extraction. They were composed of two groups. Group 1 consisted of 15 subjects, whose six anterior teeth were retracted by on masse retraction. Group 2 consisted of 15 subjects, whose canines were retracted separately. Pre-treatment and post-treatment lateral cephalometric radiographs were analyzed. All data were processed statistically with independent samples t-test, and the conclusions were as follows. 1. There was no significant difference in the amount of the anchorage loss between two groups(p>0.05). 2. There was no significant difference in the amount of the retraction of the anterior teeth between two groups(p>0.05). 3. There was a significant difference in the amount of the inclinational change of the upper incisors between two groups. It was greater in Group 2. 4. There was a significant difference in the vertical positional change of the upper incisal edges between two groups. The upper incisal edges in Group 2 were more extruded than Group 1 by about 1mm. 5. There was no significant difference in the vertical positional change of the root apex of the upper incisors between two groups(p>0.05). And there was no significant difference in the vertical positional change of the upper molar(p>0.05).

Analysis of effects from usage of skeletal anchorage-assisted Pendulum appliance on vertical component of craniofacial structure (골격고정원을 이용한 Pendulum 장치가 두개 안면의 수직적 요소에 미치는 효과 분석)

  • Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.10-16
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate distalizing effects from the Pendulum appliance on vertical component of craniofacial structures. Materials and Methods: 20 Patients who visited for orthodontic treatments are assigned to two groups. Group I, SN-MP > 37 degrees are showing hyperdivergent pattern. Group II, 29 < SN-MP < 37 degrees are showing mesocephalic pattern. Each group are consisted of 10 people. Results and Conclusions: Differences between skeletal classifications result in significant differences at labioversion of lower incisors and distalized amount, which is larger at Group I (P <.05). Group II has only shown significant distalized molars (P < .05). Labioversion of lower incisors has not shown significant change. Skeletal anchorage-assisted Pendulum appliance doesn't deteriorate vertical component nor significantly improve.