Abstract

Purpose: The purpose of this study was to evaluate distalizing effects from the Pendulum appliance on vertical component of craniofacial structures. Materials and Methods: 20 Patients who visited for orthodontic treatments are assigned to two groups. Group I, SN-MP > 37 degrees are showing hyperdivergent pattern. Group II, 29 < SN-MP < 37 degrees are showing mesocephalic pattern. Each group are consisted of 10 people. Results and Conclusions: Differences between skeletal classifications result in significant differences at labioversion of lower incisors and distalized amount, which is larger at Group I (P <.05). Group II has only shown significant distalized molars (P < .05). Labioversion of lower incisors has not shown significant change. Skeletal anchorage-assisted Pendulum appliance doesn't deteriorate vertical component nor significantly improve.

목적: 골격성 고정원의 사용으로 고정원이 보강된 Pendulum 장치가 환자의 두개 안면 요소의 수직적인 부분에 미치는 영향을 분석하고자 하였다. 연구 재료 및 방법: 골격성 고정원과, pendulum을 이용하여 비발치 치료를 시행한 환자 중, 발산형 안모(SN-MP > $37^{\circ}$)와 중간형 안모($29^{\circ}$ < SN-MP < $37^{\circ}$) 각각 10명씩 분류하여 치료의 단기적 효과에 대해 분석하였다. 결과 및 결론: 골격 형태에 따른 차이로 발산형 안모군(HG)은 구치부 후방이동과 관련하여 하악 전치의 순측 경사가 유의하게 나타났다(P < 0.05). 중간형 안모군(MG)은 구치부의 유의한 이동만 나타났다(P < 0.05). 전치의 순측 이동은 유의성이 없었다. 본 논문에서 Pendulum 장치는 수직적인 안모 형태에 유의한 영향을 주지 않으며, 악화시키지 않았다.

Keywords

References

  1. Bolla E, Muratore F, Carano A, Bowman SJ. Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods. Angle Orthod 2002;72:481-94.
  2. Burhan AS. Combined treatment with headgear and the Frog appliance for maxillary molar distalization: a randomized controlled trial. Korean J Orthod 2013;43:101-9.
  3. Fuziy A, Rodrigues de Almeida R, Janson G, Angelieri F, Pinzan A. Sagittal, vertical, and transverse changes consequent to maxillary molar distalization with the pendulum appliance. Am J Orthod Dentofacial Orthop 2006;130:502-10. https://doi.org/10.1016/j.ajodo.2004.12.031
  4. Patel MP, Janson G, Henriques JF, de Almeida RR, de Freitas MR, Pinzan A, de Freitas KM. Comparative distalization effects of Jones jig and pendulum appliances. Am J Orthod Dentofacial Orthop 2009;135:336-42. https://doi.org/10.1016/j.ajodo.2007.01.035
  5. Mah SJ, Kim JE, Ahn EJ, Nam JH, Kim JY, Kang YG. Analysis of midpalatal miniscrew-assisted maxillary molar distalization patterns with simultaneous use of fixed appliances: a preliminary study. Korean J Orthod 2016;46:55-61. https://doi.org/10.4041/kjod.2016.46.1.55
  6. Escobar SA, Tellez PA, Moncada CA, Villegas CA, Latorre CM, Oberti G. Distalization of maxillary molars with the bone-supported pendulum: a clinical study. Am J Orthod Dentofacial Orthop 2007;131:545-9. https://doi.org/10.1016/j.ajodo.2006.08.012
  7. Oncag G, Seckin O, Dincer B, Arikan F. Osseointegrated implants with pendulum springs for maxillary molar distalization: a cephalometric study. Am J Orthod Dentofacial Orthop 2007;131:16-26. https://doi.org/10.1016/j.ajodo.2005.02.034
  8. Oncag G, Akyalcin S, Arikan F. The effectiveness of a single osteointegrated implant combined with pendulum springs for molar distalization. Am J Orthod Dentofacial Orthop 2007;131:277-84. https://doi.org/10.1016/j.ajodo.2005.07.015
  9. Polat-Ozsoy O, Kircelli BH, Arman-Ozcirpici A, Pektas ZO, Uckan S. Pendulum appliances with 2 anchorage designs: conventional anchorage vs bone anchorage. Am J Orthod Dentofacial Orthop 2008;133:339.
  10. Fudalej P, Antoszewska J. Are orthodontic distalizers reinforced with the temporary skeletal anchorage devices effective? Am J Orthod Dentofacial Orthop 2011;139:722-9. https://doi.org/10.1016/j.ajodo.2011.01.019
  11. Grec RH, Janson G, Branco NC, Moura-Grec PG, Patel MP, Castanha Henriques JF. Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis. Am J Orthod Dentofacial Orthop 2013;143:602-15. https://doi.org/10.1016/j.ajodo.2012.11.024
  12. Keles A, Erverdi N, Sezen S. Bodily distalization of molars with absolute anchorage. Angle Orthod 2003;73:471-82.
  13. Kinzinger GS, Wehrbein H, Diedrich PR. Molar distalization with a modified pendulum appliancein vitro analysis of the force systems and in vivo study in children and adolescents. Angle Orthod 2005;75:558-67.
  14. Caprioglio A, Fontana M, Longoni E, Cozzani M. Long-term evaluation of the molar movements following Pendulum and fixed appliances. Angle Orthod 2013;83:447-54. https://doi.org/10.2319/050812-378.1
  15. Sar C, Kaya B, Ozsoy O, Ozcirpici AA. Comparison of two implant-supported molar distalization systems. Angle Orthod 2013;83:460-7. https://doi.org/10.2319/080512-630.1
  16. Kang JM, Park JH, Bayome M, Oh M, Park CO, Kook YA, Mo SS. A three-dimensional finite element analysis of molar distalization with a palatal plate, pendulum, and headgear according to molar eruption stage. Korean J Orthod 2016;46:290-300. https://doi.org/10.4041/kjod.2016.46.5.290
  17. Karcher H, Byloff FK, Clar E. The Graz implant supported pendulum, a technical note. J Craniomaxillofac Surg 2002;30:87-90. https://doi.org/10.1054/jcms.2002.0281
  18. Yu IJ, Kook YA, Sung SJ, Lee KJ, Chun YS, Mo SS. Comparison of tooth displacement between buccal mini-implants and palatal plate anchorage for molar distalization: a finite element study. Eur J Orthod 2014;36:394-402. https://doi.org/10.1093/ejo/cjr130
  19. Hilgers JJ. The pendulum appliances for Class II non-compliance therapy. J Clin Orthod 1992;26:706-14.
  20. Hilgers JJ, Bennet RK. The pendulum appliance: creating the gain. Clin Impressions 1994;3:14-23.
  21. Triaca A, Antonini M, Wintermantel E. Ein neus titan-flachschrauben-implantat zur orthodontischen verankerung am anterioren gaumen. Inf Orthod Kieferorthop 1992;24:251-7.
  22. Wehrbein H, Merz BR, Diedrich P. Palatal bone support for orthodontic implant anchorage-a clinical and radiological study. Eur J Orthod 1999;21:65-70. https://doi.org/10.1093/ejo/21.1.65
  23. Kircelli BH, Pektas ZO, Kircelli C. Maxillary molar distalization with a bone-anchored pendulum appliance. Angle Orthod 2006;76:650-9.
  24. Byloff FK, Darendeliler MA. Distal molar movement using the pendulum appliance. Part 1: Clinical and radiological evaluation. Angle Orthod 1997;67:249-60.