• 제목/요약/키워드: anchor bolt

검색결과 98건 처리시간 0.029초

전철주기초 설계 자동화를 위한 최적화 알고리즘의 적용성 검토 (Applicability of Optimum Algorithm for Automated Design of Electric Railway Pole Foundation)

  • 이기열;박용대;정원용;송규석;임선택;김종남;이수형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1047-1053
    • /
    • 2009
  • This paper examined an applicability of optimum algorithm to develope an electric railway pole foundation automated design system. Based on the optimization theory that considered subgrade and bearing capacity characteristics, decided an optimum section of electric railway pole foundation. In this research, Optimum algorithm used the feasible direction method in structural analysis and design efficiently. Design variables are considered geometric properties and anchor bolt area of the electric railway pole foundation as optimum construction cost. Constraints are considered settlement., overturning and activity of foundation. And, also composed flexural and shearing strength. According to optimum analysis result., optimization theory is available more economical design comparing with railway pole foundation that is constructed by current standard drawing, and applicability verified in automated design system development.

  • PDF

Manbridge Crane의 지진해석에 관한 연구

  • 윤정방;박창호
    • 전산구조공학
    • /
    • 제4권4호
    • /
    • pp.24-28
    • /
    • 1991
  • 본 연구용역에서는 반도기계주식회사의 의뢰에 의거하여 Manbridge Crane의 지진하중에 대한 구조물의 안전성을 평가하였다. 구조해석은 유한요소 모형을 사용하여 사하중, 활하중 및 OBE(Operating Basis Earthquake)와 SSE(Safe Shut-down Earthquake)의 지진하중에 관한 해석을 수행하였다. Crane설치지점의 층응답스펙트럼을 입력으로 한 응답스펙트럼해법으로 지진해석을 수행하였다. Trolley의 위치와 정격하중의 유무에 따라서 5개의 구조모형을 작성하여 해석을 수행하였으며, 지진해석에는 35개의 자유진동모드가 고려되었다. 구조해석을 통하여 1) 구조부재의 과도응력 발생여부, 2) 보강재의 좌굴 가능성, 3) Hoist Rope의 안전성, 4) Crane의 전도의 가능성 및 Seismic Lug의 안전성, 5) 지진하중에 대한 제동력, 6) Crane의 주행 Rail로부터의 탈선여부, 7) Traversing Rail의 수직처짐, 8) 주행 Rail 및 End Stopper의 Anchor Bolt의 안정성, 9) Fuel Basket과 Handrail의 안전성을 검토하였다. 해석결과를 바탕으로 설계시방서에서 제시한 모든 설계요구조건을 만족시킬 수 있도록 수직 Frame의 보강부재를 보강하고, Hoist Rope 용량을 증가시키도록 제안하였다.

  • PDF

보수.보강된 철근 콘크리트보의 구조적 거동에 관한 연구 (Structural Behavior of Strengthened RC Beams)

  • 오병환;조재열;강동옥
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.501-507
    • /
    • 1996
  • The final objectives of this study are to present the theoretical formula for reasonable structural analysis and practical codes on the repair/strengthening of damaged reinforced concrete structrues. For that purpose, in last year, preliminary experiments for flexure and shear of beam structure using carbon sheet and steel plate were performed, and in sequence, in this year, using aramid fiber sheet and steel plate more extensive experiment were performed. Repair for the performance of flexure and shear was focused on, and main variables were selected considering aplicablilty for practical field, such as, spacing of anchor bolt, lapping, jacking up, preloading level, and fiber difection as well as length of repairing plate and thickness. so new results from various angles are to be presented.

  • PDF

강판 휨보강된 철근 콘크리트보의 구조적 거동 (Structural Behavior of RC Beam Strengthened with Steel Plate)

  • 오병환;강동욱;조재열;채성태;이명규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.598-604
    • /
    • 1997
  • In recent years, strengthening by epoxy-bonded steel plates, carbon fiber sheets, aramid fiber sheets and so on, is spotlighted. Among them, the method using steel plates is most widely applied. Most studies have dealt with strengthening by epoxy-bonded steel plates. However the actual behavior of strengthened RC beams are not well established. Particularly, the studies on the separation load thar affects failure load of the beam are relatively insufficient. In this study, test parameters are the magnitude of pre-load, plate length, plate thickness, existence and spacing of anchor bolt, the number of plate layer and the height of side strengthening, 17reinforced concrete beams are strengthened by steel plates according to test parameters. Deflection, failure load, strains of reinforcing bar, concrete and plate are measured from tests(4 points loading). The failure mode, and separation load are analyzed from these measured data. The difference between Robert's theory and test results is discussed, and the prediction equation for separation load in the case of rip off is proposed.

  • PDF

Structural Response of Reinforced Concrete Beams Strengthened with CERP Rod

  • Moon Do-Young;Sim Jong-Sung;Oh Hong-Seob
    • 콘크리트학회논문집
    • /
    • 제17권6호
    • /
    • pp.1085-1090
    • /
    • 2005
  • Rod-type fiber reinforced polymer plastics(FRPs) similar to reinforcing steel bars have rarely been considered. In this study, an experiment was performed using beams strengthened with rod-type CFRPs and high-strength mortar overlay. The test results show that the strengthened beams not only had improved endurance limits but also improved load carrying capacities, stiffness values, and cracking loads as compared to a non-strengthened beam. Strengthened beams anchored with bolts throughout their entire span had more efficient structural behaviors, including composite behavior on the interface between the concrete and mortar, and load carrying capacity, than a strengthened beam anchored only on the end block.

탄소격자섬유로 보강한 철근 콘크리트보의 휨파괴 특성에 관한 연구 (Flexural Behavior of Reinforced Concrete Beams Strengthened with Grid-typs Carbon Fiber Plastics)

  • 태기호
    • 한국해양공학회지
    • /
    • 제14권1호
    • /
    • pp.52-59
    • /
    • 2000
  • Flexural fracture characteristics of newly-developed Grid-type carbon fiber plastics in the deteriorated reinforced concrete structures were investigated by the four-points fracture test to verify the strengthening effects in the beam specimens. Results showed that initial cracks appeared in the boundary layers of fibers embedded in the newly-placed mortar concrete slowly progressed to the direction of supports and showed fracture of fiber plastics and brittle failure of concrete in compression in sequence after the yielding of steel reinforcement. Accordingly the reasonable area of Grid-type carbon-fiber plastics in the strengthening design of deteriorated RC structures should be limited and given based on the ultimate strength design method to avoid the brittle failure of concrete structures.

  • PDF

Discrete crack analysis for concrete structures using the hybrid-type penalty method

  • Fujiwara, Yoshihiro;Takeuchi, Norio;Shiomi, Tadahiko;Kambayashi, Atsushi
    • Computers and Concrete
    • /
    • 제16권4호
    • /
    • pp.587-604
    • /
    • 2015
  • The hybrid-type penalty method (HPM) is suitable for representing failure phenomena occurring during the transition from continua to discontinua in materials such as concrete. Initiation and propagation of dominant cracks and branching of cracks can easily be modeled as a discrete crack. The HPM represents a discrete crack by eliminating the penalty that represents the separation of the elements at the intersection boundary. This treatment is easy because no change in the degrees of freedom for the discrete crack is necessary. In addition, it is important to evaluate the correct deformation of the continua before the crack formation is initiated. To achieve this, we implemented a constitutive model of concrete for the HPM. In this paper, we explain the implemented constitutive model and describe the simulation of an anchor bolt pullout test using the HPM demonstrating its capability for evaluating progressive failure.

A PERFORMANCE ASSESSMENT OF A BASE ISOLATION SYSTEM FOR AN EMERGENCY DIESEL GENERATOR IN A NUCLEAR POWER PLANT

  • Choun, Young-Sun;Kim, Min-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.285-298
    • /
    • 2008
  • This study evaluates the performance of a coil spring-viscous damper system for the vibration and seismic isolation of an Emergency Diesel Generator (EDG) by measuring its operational vibration and seismic responses. The vibration performance of a coil spring-viscous damper system was evaluated by the vibration measurements for an identical EDG set with different base systems - one with an anchor bolt system and the other with a coil spring-viscous damper system. The seismic performance of the coil spring-viscous damper system was evaluated by seismic tests with a scaled model of a base-isolated EDG on a shaking table. The effects of EDG base isolation on the fragility curve and core damage frequency in a nuclear power plant were also investigated through a case study.

Bolted connectors with mechanical coupler embedded in concrete: Shear resistance under static load

  • Milicevic, Ivan;Milosavljevic, Branko;Pavlovic, Marko;Spremic, Milan
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.321-337
    • /
    • 2020
  • Contemporary design and construction of steel-concrete composite structures employs the use of prefabricated concrete elements and demountable shear connectors in order to reduce the construction time and costs and enable dismantling of elements for their potential reuse at the end of life of buildings. Bolted shear connector with mechanical coupler is presented in this paper. The connector is assembled from mechanical coupler and rebar anchor, embedded in concrete, and steel bolt, used for connecting steel to concrete members. The behaviour and ultimate resistance of bolted connector with mechanical coupler in wide and narrow members were analysed based on push-out tests and FE analyses conducted in Abaqus software, with focus on concrete edge breakout and bolt shear failure modes. The effect of concrete strength, concrete edge distance and diameter and strength of bolts on failure modes and shear resistance was analysed. It was demonstrated that premature failure by breakout of concrete edge occurs when connectors are located 100 mm or closer from the edge in low-strength and normal-strength reinforced concrete. Furthermore, the paper presents a relatively simple model for hand calculation of concrete edge breakout resistance when bolted connectors with mechanical coupler are used. The model is based on the modification of prediction model used for cast-in and post-installed anchors loaded parallel to the edge, by implementing equivalent influence length of connector with variable diameter. Good agreement with test and FE results was obtained, thus confirming the validity of the proposed method.

콘크리트포장 확장부 타이바 설치방법의 개발 (Development of Tie-Bar Installation Method for Concrete Pavement Widening)

  • 황인규;양성철;정진훈;유태석
    • 한국도로학회논문집
    • /
    • 제8권1호
    • /
    • pp.33-43
    • /
    • 2006
  • 신설포장에 시공되는 타이바의 경우에는 콘크리트 타설시 타이바가 슬래브 안에 묻히기 때문에 타이바의 정착강도가 문제되지 않으나, 확장시에는 기존 포장을 천공한 후 충전재를 주입하여 설치하기 때문에 타이바가 충분한 정착강도를 확보 할 수 있도록 설계해야 한다. 만일 삽입된 타이바가 충분한 정착강도를 확보하지 못한다면, 슬래브 간에 하중 전달에 문제가 생길 뿐만 아니라 줄눈 간격이 과도하게 벌어져서 사용성 및 내구성에도 나쁜 영향을 주게 된다. 본 연구에서는 현재 현장에서 설치하는 시공방법에 의해 타이바의 정착강도를 확인하고 이에 대한 대안을 제시 하고자 한다. 실험결과 현장 시공방법으로 설치된 타이바의 정착강도는 소요 정착강도의 42.7%에 불과하였다. 첫 번째 대안으로서 주입기를 이용하여 충전재를 주입하고 마개를 사용하여 충전재가 흘러 나오지 못하게 막는 방법의 경우에는 소요 정착강도를 충분히 만족 하였으나, 현장에서의 품질관리가 쉽지 않을 것으로 판단된다. 두 번째 대안으로 제시된 SL 앵커볼트를 이용하여 타이바를 설치하는 방법은 충분한 정착강도를 확보 할 수 있으며 품질관리 및 시공성이 용이 한 것으로 판단된다.

  • PDF