• Title/Summary/Keyword: analyzer

Search Result 4,492, Processing Time 0.034 seconds

Clinical Usefulness of Point-of-care Test Chemistry Analyzer in Neonatal Intensive Care Unit

  • Jang, Yeong-Uk;Kim, Su-Nam;Cho, Hye-Jung;Sun, Yong-Han;Shim, So-Yeon;Son, Dong-Woo;Park, Pil-Whan
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.301-309
    • /
    • 2011
  • Purpose: Point-of-care tests (POCTs) have the potential to significantly influence management of neonates. The aim of this study was to assess the clinical usefulness of the POCT chemistry analyzer in a neonatal intensive care unit (NICU). Methods: Blood samples of neonates admitted to the NICU were tested using a POCT chemistry analyzer (Piccolo Xpress Chemistry Analyzer, Abaxis, Union City, CA, USA) and a central laboratory chemical analyzer (Chemistry analyzer 7600-110, Hitachi Ltd., Tokyo, Japan) from March to September, 2010. Correlation of 15 analytes between the POCT and the central laboratory machine was evaluated. For consistency of the POCT, three consecutive samplings were performed. Differences among the three tests were recorded. The causes of performance errors were checked through log files. Results: One hundred of 112 pairs of tests for accuracy performed in 54 neonates showed a high correlation between the two machines. Twelve performance errors occurred during the 112 tests. The most common error was insufficient sample error. Eighteen triplet tests performed in 18 patients for consistency revealed a difference range of 3-10%, which was considered to be acceptable. No error occurred during the 54 tests. Conclusion: The POCT is capable of analyzing multiple analytes with a minimal amount of whole blood in a short time. The few performance errors noted presently are likely preventable. This POCT is concluded to be suitable for use as a simple and rapid diagnostic method in the NICU with a minimal amount of blood collected in a less invasive manner.

Implementation of a Static Analyzer for Detecting the PHP File Inclusion Vulnerabilities (PHP 파일 삽입 취약성 검사를 위한 정적 분석기의 구현)

  • Ahn, Joon-Seon;Lim, Seong-Chae
    • The KIPS Transactions:PartA
    • /
    • v.18A no.5
    • /
    • pp.193-204
    • /
    • 2011
  • Since web applications are accessed by anonymous users via web, more security risks are imposed on those applications. In particular, because security vulnerabilities caused by insecure source codes cannot be properly handled by the system-level security system such as the intrusion detection system, it is necessary to eliminate such problems in advance. In this paper, to enhance the security of web applications, we develop a static analyzer for detecting the well-known security vulnerability of PHP file inclusion vulnerability. Using a semantic based static analysis, our vulnerability analyzer guarantees the soundness of the vulnerability detection and imposes no runtime overhead, differently from the other approaches such as the penetration test method and the application firewall method. For this end, our analyzer adopts abstract interpretation framework and uses an abstract analysis domain designed for the detection of the target vulnerability in PHP programs. Thus, our analyzer can efficiently analyze complicated data-flow relations in PHP programs caused by extensive usage of string data. The analysis results can be browsed using a JAVA GUI tool and the memory states and variable values at vulnerable program points can also be checked. To show the correctness and practicability of our analyzer, we analyzed the source codes of open PHP applications using the analyzer. Our experimental results show that our analyzer has practical performance in analysis capability and execution time.

ZEUS Co. Ltd

  • 강신국
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.50-50
    • /
    • 2000
  • 당사는 1970년 제우스 콤 상사로부터 출발하여 1988년 12우러 주식회사 제우스로 법인 전환한 후 현재 한국반도체 산업협회 및 회원으로 등록 활동하고 있다. 이번 발표에서는 회사에 대한 소개와 함께 취급품목을 설명하고자 한다. 취급품목은 Ion beam sources(CSC), E-beam evaporator & E-beam source(Temescal), Residual Gas Analyzer(SPECTRA), Cryopump & Waterpump(CTI-Cryogenics), Thickness Monitor & Controller, Electrical Feedthrough, RTP system, Thin Film Analyzer, PECVD, RIE 등이다.

  • PDF

Refinement for Loops in Buffer-Overrun Abstract Interpretation (요약해석을 이용한 버퍼오버런 분석에서 루프 분석결과의 정교화)

  • Oh, Hak-Joo;Yi, Kwang-Keun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.1
    • /
    • pp.111-115
    • /
    • 2008
  • We present a simple and effective method to reduce loop-related false alarms raised by buffer-overrun static program analyzer. Interval domain buffer-overrun analyzer raise many false alarms in analyzing programs that frequently use loops and arrays. Firstly, we classified patterns of loop-related false alarms for loop-intensive programs, such as embedded programs or mathematical libraries. After that we designed a simple and effective false alarm refiner, specialized for the loop-related false alarms we classified. After the normal analysis of program in which alarms considered as false. We implemented this method on our buffer-overrun analyzer with the result that our refinement method decreased the number of false alarms by 32% of total amount the analyzer reported.

Comparative Experiment to Determine the Activation Factor of Lead dioxide by Kinds in Measuring the Concentration of Sulfur oxides in the Atmosphere by $PbO_2$ Cylinder Method (사용시약별로 본 이산화연법에 의한 대기중 황산화물의 비교측정및 자동측정 성적과의 비교)

  • 최덕일
    • Journal of Environmental Health Sciences
    • /
    • v.2 no.1
    • /
    • pp.29-31
    • /
    • 1975
  • This experiment Was carried out under two points of view, from May 1st to the end of 1973. One was the comparative determination of the activation factor of Lead dioxide by kinds in measuring of Sulfur oxides concentration by $PbO_2$ cylinder method, and the other was the comparison that result with the record of auto analyzer. Five measuring sites were selected out of Seoul City. Three kinds of Lead dioxide made in Japan (B,C and D) were compared with Standard $PbO_2$ (A for use in Determination of Sulphur in the atmosphere, purity 99% up) made in British Institution, and monthly measuring was conducted at every sampling site. The recording by auto analyzer (Beckman Model 906-A $SO_2$ Analyzer) was conducted once or twice a month for 24 hours at each sampling site during the same period. And some significant results were obtained. 1. In comparative experiments to determine the activation degree of three kinds of Lead dioxide (B,C and D), the obtained correction factor of B reagent was 1.09, 1.16 in C and 1.30 in D against Standard $PbO_2$ (A). Therefore, it should be in need of standardization or clear statement about the reagents for use, in determination sulfur oxides by $PbO_2$ cylinder method. 2. Generally, the concentration of Sulfur dioxide by wilkins' convertion method from $SO_3$ showed about 20-30% higher than those by Auto analyzer.

  • PDF

Proposal for Pulse Diagnosis Positions (Chon-Kwan-Chuk) for Pulse Analyzer Based on Literature Review and Anthropometry (문헌고찰 및 실측에 근거한 맥진기 측정시 촌관척 정위에 대한 제안)

  • Kim, Hyun-Ho;Lee, Jeon;Kim, Ki-Wang;Kim, Jong-Yeol
    • The Journal of Korean Medicine
    • /
    • v.28 no.3 s.71
    • /
    • pp.13-22
    • /
    • 2007
  • Objectives : To obtain pulse information, oriental medical doctors usually use the three finger pulse diagnosis method. Although the diagnostic positions are very important, the exact positions are not known because of the uncertain conversion of measures of length (bun, chon, chuk) and misunderstanding of the related concepts of oriental medicine. In this study, we proposed relative positions for the detection of three pulses with a pulse analyzer. Methods : The proposal was made based mainly on several literature reviews, especially the original texts, and the examination of anthropometric characteristics of 78 individuals. Results : The Kwan is the spot where the radial pulse can be felt well near the eminent head of the radius at wrist, high bone. The position of Chon should be apart from Kwan by 6/10 distance between the high bone and wrist joint of each individual. Finally, the position of Chuk is apart from Kwan by 6.5/100 distance between the high bone and the elbow joint of each individual. Conclusions : Adapting those proposed positions for measuring three pulses can provide more consistent information to what an oriental doctor obtains than a pulse analyzer applied to other positions.

  • PDF

A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy (근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구)

  • Yoon, Sung-Un;Ma, Sang-Dong;Kim, Myung-Yun;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.

A Study on Thermal Characteristic Carbon and other Elements in Suspended Particulates (대기 입자상물질중 탄소(C)등의 열적특성에 관한 조사연구)

  • 황경철
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.31-39
    • /
    • 1990
  • An analytical method for particulate carbon and other elements by using elemental analyzer was investigated. Carbon, hydrogen, and nitrogen was determined as CO$_{2}$, H$_{2}$, and N$_{2}$, respectively. Organic was determined after scparation from elemental carbon(Cae) by volatilization and thermal decomposition in a heated helium flow. With organic materials examined in this reprot, more than 90% of carbon was detected as above 600$^{\circ}$C. But it is considered that a few percents of some compounds were charred above 550$^{\circ}$C. A small amount of Cae was oxidized in the inert atmosphere above 850$^{\circ}$C, but the reason was not explained clearly. Based on the thermal chracteristics of Cao it was found that the optimum temperature of heating in the helium flow of an elemental analyzer for Cao analysis is 630$^{\circ}$C. Carbon in a sample after removing Cao was assumed as Cae and the gramatom ratio of hydrogen to carbon in the sample was 0.4 and less. Rescovery of nitrogen derived from some ammonium salts and nitrates was 100% by two-step measurement with elemental analyzer. By the analytical method investigated in this report, carbon and other elements in suspended particulates(S.P) collected at an urban area in Seoul were measured. There was a good correlation between total nitrogen in SP measured by elemental analyzer and nitrogen estimated form ammonium ions and nitrate ions in SP. The nitrogen from these ions accounts for 80% of the total nitrogen. It is further suggested that the residue(20%) of the total nitrogen is attributed to the other nitrogeneous compounds.

  • PDF