• Title/Summary/Keyword: analyzer

Search Result 4,484, Processing Time 0.028 seconds

Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

Analysis of Voice Parameters on Different Phonatory Tasks using Multi-Channel Phonatory Function Analyzer in Healthy Adults (다채널 음성분석장치를 이용한 정상 성인에서의 발성 방식에 따른 음성변수 분석)

  • 성명훈;이상준;김광현;노종렬;권택균;이강진;박광석;최종민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Background and Objectives : The complex physiologic structure of the larynx can vibrate in three or more different ways that yield acuostically and perceptually distinct vocal quality. The purpose of this study is to examine the normal range of voice parameters in Multi-Channel Phonatory Function Analyzer and investigate the difference of voice parameters according to the phonatory patterns. Materials and Methods : Forty normal adult speakers (20 men and 20 women) with age ranging from third to forth decades pronounce low, comfortable, and high tone /a/ ; comfortable tone /${\ae}$/, /i/, /o/, and /u/ : fry, falsetto. Voice was analyzed by Newly developed multi-channel phonatory function analyzer. Results : The normal range of voice parameters in this system was similar to the existing data. Fry shows high jitter and falsetto low SQ. Fry and falsetto show low OQ in men but no difference in women. Jitter, OQ and SQ were different between men and women in modal register, whereas there was no gender difference in fry and falsetto. In frequency magnitude spectrum and EGG, modal register, fry and falsetto have distinguishing pattern. Conclusions : Modal register, fry and falsetto are distinguishable in voice parameters and show different vibratory patterns.

  • PDF

Implementation of a Dialogue Interface System Using Pattern Matching and Statistical Modeling (패턴 매칭과 통계 모델링을 이용한 대화 인터페이스 시스템의 구현)

  • Kim, Hark-Soo
    • The Journal of Korean Association of Computer Education
    • /
    • v.10 no.3
    • /
    • pp.67-73
    • /
    • 2007
  • In this paper, we review essential constituents of a dialogue interface system and propose practical methods to implement the each constituent. The implemented system consists of a discourse manager, an intention analyzer, a named entity recognizer, a SQL query generator, and a response generator. In the progress of implementation, the intention analyzer uses a maximum entropy model based on statistics because the domain dependency of the intention analyzer is comparatively low. The others use a simple pattern matching method because they needs high domain portability. In the experiments in a schedule arrangement domain, the implemented system showed the precision of 88.1% in intention analysis and the success rate of 83,4% in SQL query generation.

  • PDF

Plasma Facing Material 흡착기체의 정량적 분석을 위한 Thermal Desorption Analyzer (TDA) 개념 설계

  • Kim, Hui-Su;On, Yeon-Gil;Lee, Seok-Gwan;Choe, Min-Sik;No, Seung-Jeong;Gwon, Jin-Jung;Park, Jun-Gyu;Lee, Cheol-Ui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.513-513
    • /
    • 2012
  • 핵 융합로의 대면재질(Plasma Facing Material; PFM)은 고온의 플라즈마와 고 에너지의 이온들에 지속적으로 노출 된다. 특히 PFM은 흡착되는 기체 등에 의한 부식과 변형이 발생할 수 있다. 현재 핵 융합로 내부의 PFM으로 고려되고 있는 재질 중 하나인 고순도 탄소타일의 경우 고온의 수소동위원소 플라즈마에 직접적으로 노출되므로 이에 의한 탄소타일에 흡착되는 수소 등의 기체에 대한 정량적인 분석방법이 필요하다. 본 연구는 고순도 탄소타일 등과 같은 플라즈마 대면재료에 흡착되어 있는 물질의 정량적 분석이 가능한 TDA (Thermal Desorption Analyzer)의 개념 설계에 관한 것이다. TDA는 고온 가열($800^{\circ}C$ 이상) 및 시료 장착부 및 초고진공(~10-9 torr) 및 측정부의 두 부분으로 구성 하였다. TDA 설계시 고온 가열 및 시료 장착부는 시료 내부에 흡착되어 있는 기체의 효과적 탈착을 위한 가열 및 시료의 모양에 영향을 받지 않는 장착방법, 시료 장착부의 outgassing rate를 최소화 하는 재질 선정 등을 고려하였으며, 초고진공(~10-9 torr) 및 측정부는 초고진공 유지방법, 터보펌프 배기속도 실측을 위한 구조, 진공측정 ion 게이지, 잔류가스분석기(Residual Gas Analyzer)의 최적위치 설정 등을 고려하여 설계하였다. 개념 설계된 TDA에 대하여 발표하고자 한다.

  • PDF

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.

Disturbance Observer-Based Hybrid Control of Displacement and Force in a Medical Tele-Analyzer

  • Suebsomran Anan;Parnichkun Manukid
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.70-78
    • /
    • 2005
  • This paper presents hybrid control of displacement and force in a Medical Tele-Analyzer by disturbance observer-based controller which is robust to internal and external disturbances; model uncertainty, load, and friction for instances. The developed Medical Tele-Analyzer consists of 2 subsystems; doctor-side subsystem and patient-side subsystem. In the doctor side subsystem, an array of displacement sensor is equipped to detect movement of doctor's hand and fingers. The detected information is transmitted to the patient side to be used in medical analysis. On the other hand, the patient-side subsystem consists of an array of displacement actuators, which is used to follow displacement of doctor's hand and fingers. An array of force sensors is used to detect forces between patient and the equipment. Since displacement control in patient side is coupled with force control in doctor side and vice-versa, design of the controller has to take into account this coupling. Not only using in medical tele-analysis, the proposed system can also be used in any tele-displacement-force controls of industrial processes.

Temporal Database Management Testbed (시간 지원 데이타 베이스 관리 시험대)

  • Kim, Dong-Ho;Jeon, Geun-Hwan
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.1
    • /
    • pp.1-13
    • /
    • 1994
  • The Temporal Database Management Testbed supports valid and transaction time. In this paper, we discuss the design and implementation of a testbed of a temporal database management system in main memory. The testbed consists of a syntactic analyzer, a semantic analyzer, a code generator, and an interpreter. The syntactic analyzer builds a parse tree from a temporal query. The semantic analyzer then checks it for correctness against the system catalog. The code generator builds an execution tree termed ann update network. We employ an incremental view materialization for the execution tree. After building the execution tree, the interpreter activates each node of the execution tree. Also, the indexing structure and the concurrency control are discussed in the testbed.

  • PDF

A Study on the Development of R-R Interval Analyzer using Microcomputer (1) (Microcomputer를 이용한 R-R Interval Analyzer 개발에 관한 연구 (1))

  • Lee, Joon-Ha;Choi, Soo-Bong
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.77-80
    • /
    • 1985
  • The R-R interval analyzer was developed to measure the autonomic nervous system function using microcomputer. The system based on 8 bit microcomputer including bandpass filter, R-wave detector and clock generator in order to obtain the mean value, standard deviation, total time, CV value, maximum value and minimum value in the specific view point of R-R interval variation. The pattern of R-R interval change after resting, voluntary standing and deep breathing can be analysed in normal subjects and diabetics with autonomic nervous dysfunction. The amplitude of the R-R interval variation showed sensitive pattern for normal subjects at resting, standing and deep breathing. On the contrary, the periodicities of amplitude for abnormal subjects with autonomic nervous dysfunction showed dull pattern. It was suggested that R-R interval analyzer is a good detection method for dysfunction of autonomic nervous system.

  • PDF

The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.