• Title/Summary/Keyword: analysis methods

Search Result 52,691, Processing Time 0.085 seconds

The Effect of an Anticholinergic Agent(Oxybutynin) on Spontaneous Resolution of Primary Vesicoureteral Reflux (항콜린제(옥시부티닌)가 원발성 방광요관역류의 자연 소실에 미치는 영향)

  • Ahn So-Hyun;Shim So-Yun;Lee Jung-Won;Cho Su-Jin;Lee Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.7 no.2
    • /
    • pp.174-180
    • /
    • 2003
  • Purpose : Unstable bladder has been known to be one of the reasons for the genesis and persistance of primary vesicoureteral reflux(VUR) in children. And treatment of unstable bladder by anticholinergic agent may contribute to the resolution of primary VUR. We evaluated the effect of an anticholinergic agent(oxybutynin) on the resolution of primary VUR in children with different toilet training and voiding functions. Methods : 152 children with persistant primary VUR after one year of follow up were randomly assigned to the oxybutynin group(n=59, oxybutynin 0.2 mg/kg twice daily) and the control group(n=93, no oxybutynin) at Ewha Womans University Mok-Dong Hospital from October 1996 to April 2002. The resolution rate of the VUR and the difference according to the status of toilet training and voiding dysfunction were analyzed. Statistical analysis was done by the Chi-square test and a P-value of less than 0.05 was considered as significant. Results : VUR was resolved in 49.2%, improved in 20.3% and not changed in 30.5% in the oxybutynin group(n=59) which was not significantly different to 45.2%, 16.1%, 38.7% in the control group(n=93), respectively. In the non-toilet trained young children, VUR was resolved in 50.0%, improved in 23.5% and not changed in 26.5% in the oxybutynin group(n=34) which was not significantly different to 44.2%, 19.2%, 36.6% in the control group(n=52), respectively. In the toilet trained older children, VUR was resolved in 48.0%, improved in 16.0% and not changed in 36.0% in the oxybutynin group(n=25) which was not significantly different to 46.3%, 12.2%, 41.5% in the control group(n=41), respectively. In the toilet trained older children with no voiding dysfunction, VUR was resolved in 33.3%, improved in 11.1% and not changed in 55.5% in the of oxybutynin group(n=9) which was not significantly different to 53.6 %, 10.7%, 35.7% in the control group(n=28), respectively. In the toilet trained older children with voiding dysfunction, VUR was resolved in 56.3%, improved in 18.7% and not changed in 25.0% in the oxybutynin group(n=16), which looked higher than 30.7%, 15.4%, 53.9% in the control group(n=13), respectively, but these were not significantly different either. Conclusion : Oxybutynin was not effective in the resolution of primary VUR in non-toilet trained young children and toilet trained older children. Oxybutynin showed slightly higher tendency of reflux resolution in toilet-trained older children with voiding dysfunction but the difference was not statistically significant. Judicious use of oxybutynin is required in selected older children with VUR and voiding dysfunction.

  • PDF

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF

AGL gene mutation and clinical features in Korean patients with glycogen storage disease type III

  • Ko, Jung-Min;Kim, Gu-Hwan;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.72-79
    • /
    • 2007
  • Purpose : Glycogen storage disease type III (GSD-III) is a rare autosomal recessive disorder of glycogen metabolism. The affected enzyme, amylo-1,6-glucosidase, 4-alpha-glucanotransferase (AGL, glycogen debranching enzyme), is responsible for the debranching of the glycogen molecule during catabolism. The disease shows clinical and biochemical heterogeneity, reflecting genotype-phenotype heterogeneity among different patients. In this study, we aim at analyzing mutations of the AGL gene in three unrelated Korean GSD-III patients, and characterizing their clinical and laboratory findings. Methods : We characterized the clinical features of three unrelated Korean GSD-III patients by biochemical, histological and imaging studies. The 35 exons and part of exon-intron boundaries of AGL were analyzed by direct sequencing using genomic DNA extracted from the peripheral leukocytes of patients. Results : Diverse clinical features were observed in these patients including hepatomegaly (all patients), seizures (patient 2), grow th failure (patients 1 and 2), hyperlipidemia (patients 1 and 3), raised transaminase and creatine kinase concentrations (all patients), and mild cardiomyopathy (patient 2). Liver transplantation w as performed in patient 2 due to progressive hepatic fibrosis. A dministration of uncooked corn starch maintained normoglycemia and improved biochemical and growth profiles. DNA sequence analysis revealed mutations in 5 out of 6 alleles. Patient 1 was a compound heterozygote of c.1282 G>A (p.R428K) and c.1306delA (p.S603PfsX6), patient 2 had c.1510_1511insT (p.Y 504L fsX 10), and patient 3 had c.3416 T >C (p.L 1139P) and c.1735+1 G>T (p.Y 538_R578delfsX 4) mutations. A part from the p.R428K mutation, the 4 other substitutions identified w ere nov el. Conclusion : GSD-III patients display variable phenotypic characteristics resembling those of GSD-Ia. Molecular defects in the AGL gene of Korean GSD-III patients are genetically heterogeneous.

  • PDF

Migration of $^{99m}Tc$-Hexamethylpropylene Amino Oxime (HMPAO) Labeled Immature and Mature Dendritic Cells in the Mouse (마우스에서 Tc-99m HMPAO 표지 미성숙 및 성숙 수지상세포의 이동에 관한 연구)

  • Li, Ming-Hao;Lee, Je-Jung;Min, Jung-Joon;Heo, Young-Jun;Song, Ho-Chun;Park, Young-Kyu;Park, An-Na;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.26-33
    • /
    • 2005
  • Purpose: The purpose of this study is to evaluate migration of technetium-99m hexamethylpropylene amine oxime ($^{99m}Tc$-HMPAO) labeled immature and mature dendritic cells (DC) in the mouse. Methods: DC were collected from bone marrow (BM) of tibiae and femurs of mice. Immature and mature DC from BM cells were radiolabeled with $^{99m}Tc$-HMPAO. To evaluate the functional and phenotypic changes of DC from radiolabeling, the allogeneic mixed lymphocyte reaction (MLR) and fluorescence-activated cell sorting (FACS) analysis were performed before and after labeling with $^{99m}Tc$-HMPAO. Migration of intravenously injected DC (iv-DC) was assessed by serial gamma camera images of mice with or without subcutaneous tumor. Percent injected dose per gram (%ID/g) was calculated in lungs, liver, spleen, kidneys, and tumor through dissection of each mice after 24 hours of injection. Results: Labeling efficiency of immature and mature DC were $60.4{\pm}5.4%\;and\;61.8{\pm}6.7%$, respectively. Iv-DC initially appeared in the lungs, then redistributed mainly to liver and spleen. Migration of mature DC to spleen was significantly higher than that of immature DC ($38.3{\pm}4.0%\;vs.\;32.2{\pm}4.1%$ in control group, $40.4{\pm}4.1%\;vs.\;35.9{\pm}3.8%$ in tumor group; p<0.05). Migration to tumor was also significantly higher in mature DC than in immature DC ($2.4{\pm}0.3%\;vs\;1.7{\pm}0.2%$; p=0.034). Conclusion: Assessment of migration pattern of DC in mice was possible using $^{99m}Tc$-HMPAO labeled immature and mature DC. Migration of mature DC to spleen and tumor was higher than that of immature DC when they were i.v. injected.

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

The efficacy of Quantitative Analysis of Basal/Acetazolamide SPECT Using SPM and Statistical Probabilistic Brain Atlas in Patients with Internal Carotid Artery Stenosis (뇌혈관 협착 환자에서 SPM과 확률뇌지도를 이용한 기저/아세타졸아미드 SPECT의 정량적 분석법의 유용성)

  • Lee, Ho-Young;Lee, Dong-Soo;Paeng, Jin-Chul;Oh, Chang-Wan;Cho, Maeng-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.357-367
    • /
    • 2002
  • Purpose: While cerebral blood flow and cerebrovascular reserve could be evaluated with basal/acetazolamide Tc-99m-HMPAO SPECT in cerebrovascular disease, objective quantification is necessary to assess the efficacy of the revascularization. In this study we adopted the SPM method to quantify basal cerebral blood flow and cerebrovascular reserve on basal/acetazolamide SPECT in assessment of the patients who underwent bypass surgery for linternal carotid artery (ICA) stenosis. Materials and Methods: Twelve patients ($51{\pm}15$ years) with ICA stenosis were enrolled. Tc-99m-HMPAO basal/acetazolamide perfusion SPECT was peformed before and after bypass surgery. After spatia1 and count normalization to cerebellum, basal cerebral blood flow and cerebrovascular reserve were compared with 21 age-matched normal controls and postoperative changes of regional blood flow and reserve were assessed by Statistical Parametric Mapping method. Mean pixel values of each brain region were calculated using probabilistic anatomical map of lobes. Perfusion reserve was defined as the % changes after acetazolamide over basal counts. Results: Preoperative cerebral blood flow and cerebrovascular reserve were significantly decreased in involved ICA territory, comparing with normal control (p<0.05). Postoperative improvement of cerebral blood flow and cerebrovascular reserve was observed in grafted ICA territories, but cerebrovasculr reserve remained with significant difference with normal control. Improvement of the cerebrovascular reserve was most prominent in the superior temporal and the angular gyrus, nearest to the anastomosis sites. Conclusion: Using SPM quantification method on hasal/acetazolamide Tc-99m-HMPAO SPECT, the cerebral blood flow and cerebrovascular reserve could be assessed before revascularization and so could the efficacy of the bypass surgery.

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Determination of Representative Renal Depth for Accurate Attenuation Correction in Measurement of Glomerular Filtration Rate in Transplanted Kidney (이식 신의 사구체 여과율 측정에서 정확한 감쇄 보정을 위한 신장 깊이 대표값 설정)

  • Oh, Soon-Nam;Kim, Sung-Hoon;Rha, Sung-Eun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Lee, Sung-Young;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2002
  • Purpose: To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. Materials and Methods: We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured GFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depths under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. Results: The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are $4.09{\pm}0.65cm$ in men, and $4.24{\pm}0.78cm$ in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. Conclusion: When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply.

The Study on the Correlation of the Ejection Fraction of Multi Gated Blood Pool Scan and Echocardiography According to the Condition of Cardiac Function (심장기능상태의 분류에 따른 게이트심장혈액풀 검사와 심장초음파의 심박출계수 상관관계에 관한 고찰)

  • Lee, Dong Hun;Park, Jang Won;Nam, Ki Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.57-61
    • /
    • 2015
  • Purpose We considered the correlation of Ejection Fraction (EF) which was analyzed by Multi Gated Blood Pool Scan (MUGA) and Echocardiography (ECHO) for the patients who were classified according to the condition of cardiac function. Materials and Methods We analyzed the patients (female 60) who were diagnosed with breast cancer and were examined by both MUGA and ECHO. The 30 patients (age: $58.27{\pm}13.48$) who were analyzed into less than 50% to 70% of EF were categorized as normal group and the other 30 patients (age: $53.70{\pm}8.45$) who were analyzed into less than 50% of EF were categorized as abnormal group. Statistical analysis with SPSS ver. 18 was applied. Results Each of the value of mean and standard deviation of normal group was $66.43{\pm}5.80$ (MUGA), $60.50{\pm}4.93$ (ECHO). There was a significant difference (p<0.001). Each of the value of mean and standard deviation of abnormal group was $41.93{\pm}7.58$ (MUGA), $41.70{\pm}11.49$ (ECHO). There was no significant difference (p>0.001). In the result, all 30 cases of normal group showed the same reading. 8 out of 30 cases in abnormal group showed inconsistency of the reading. Conclusion We could confirm the correlation of the EF in MUGA and ECHO statistically. There was difference between abnormal groups from the result of reading. If we are aware of the result according to the different cardiac function categorization, MUGA and ECHO can be used as even more accurate interchangeable test.

  • PDF

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.