• 제목/요약/키워드: amplitude control

검색결과 966건 처리시간 0.024초

Characterization of Cooked Meat Models using Grasshopper (Sphenarium purpurascens) Soluble Protein Extracted by Alkalisation and Ultrasound as Meat-Extender

  • Cruz-Lopez, Salvador Osvaldo;Escalona-Buendia, Hector Bernardo;Roman-Guerrero, Angelica;Dominguez-Soberanes, Julieta;Alvarez-Cisneros, Yenizey Merit
    • 한국축산식품학회지
    • /
    • 제42권3호
    • /
    • pp.536-555
    • /
    • 2022
  • The most abundant Orthoptera in Mexico is a small grasshopper (Sphenarium purpurascens) which is considered a food source with increased nutritional value due to its high protein content. Insect proteins have gained relevance because of their high potential as gelling, texturing, and extender agents in the food industry. The objective of this study was to evaluate the effect of substituting meat with a soluble protein extract from grasshopper obtained by alkalisation or alkalisation-piezoelectric ultrasound, on the techno-functional, physicochemical, and sensory characteristics of cooked meat models (sausages). The soluble protein was extracted in NaHCO3 pH 8 and a piezoelectric ultrasound 5-mm sonotrode at 20 kHz with 99% amplitude. Different formulations with meat substitution: 0%, 5%, 10%, and 15% were prepared and characterised for their rheological behaviour, emulsion stability, weight loss by cooking, total protein content, colour, and texture. Sensory evaluation was conducted with consumers using a test involving check-all-that-apply and overall liking. The alkalisation-piezoelectric ultrasound method improved the solubility and the techno-functional properties of the soluble grasshopper protein when applied in sausages at maximum levels of 10% meat substitution. The sensory evaluation indicated that the formulation with 5% meat substitution exhibited the same acceptability as the control sample. Given these results, the soluble protein treated with alkalisation and piezoelectric ultrasound could be used as an extender in meat products.

Sound-Field Speech Evoked Auditory Brainstem Response in Cochlear-Implant Recipients

  • Jarollahi, Farnoush;Valadbeigi, Ayub;Jalaei, Bahram;Maarefvand, Mohammad;Zarandy, Masoud Motasaddi;Haghani, Hamid;Shirzhiyan, Zahra
    • 대한청각학회지
    • /
    • 제24권2호
    • /
    • pp.71-78
    • /
    • 2020
  • Background and Objectives: Currently limited information is available on speech stimuli processing at the subcortical level in the recipients of cochlear implant (CI). Speech processing in the brainstem level is measured using speech-auditory brainstem response (S-ABR). The purpose of the present study was to measure the S-ABR components in the sound-field presentation in CI recipients, and compare with normal hearing (NH) children. Subjects and Methods: In this descriptive-analytical study, participants were divided in two groups: patients with CIs; and NH group. The CI group consisted of 20 prelingual hearing impairment children (mean age=8.90±0.79 years), with ipsilateral CIs (right side). The control group consisted of 20 healthy NH children, with comparable age and sex distribution. The S-ABR was evoked by the 40-ms synthesized /da/ syllable stimulus that was indicated in the sound-field presentation. Results: Sound-field S-ABR measured in the CI recipients indicated statistically significant delayed latencies, than in the NH group. In addition, these results demonstrated that the frequency following response peak amplitude was significantly higher in CI recipients, than in the NH counterparts (p<0.05). Finally, the neural phase locking were significantly lower in CI recipients (p<0.05). Conclusions: The findings of sound-field S-ABR demonstrated that CI recipients have neural encoding deficits in temporal and spectral domains at the brainstem level; therefore, the sound-field S-ABR can be considered an efficient clinical procedure to assess the speech process in CI recipients.

Sound-Field Speech Evoked Auditory Brainstem Response in Cochlear-Implant Recipients

  • Jarollahi, Farnoush;Valadbeigi, Ayub;Jalaei, Bahram;Maarefvand, Mohammad;Zarandy, Masoud Motasaddi;Haghani, Hamid;Shirzhiyan, Zahra
    • Journal of Audiology & Otology
    • /
    • 제24권2호
    • /
    • pp.71-78
    • /
    • 2020
  • Background and Objectives: Currently limited information is available on speech stimuli processing at the subcortical level in the recipients of cochlear implant (CI). Speech processing in the brainstem level is measured using speech-auditory brainstem response (S-ABR). The purpose of the present study was to measure the S-ABR components in the sound-field presentation in CI recipients, and compare with normal hearing (NH) children. Subjects and Methods: In this descriptive-analytical study, participants were divided in two groups: patients with CIs; and NH group. The CI group consisted of 20 prelingual hearing impairment children (mean age=8.90±0.79 years), with ipsilateral CIs (right side). The control group consisted of 20 healthy NH children, with comparable age and sex distribution. The S-ABR was evoked by the 40-ms synthesized /da/ syllable stimulus that was indicated in the sound-field presentation. Results: Sound-field S-ABR measured in the CI recipients indicated statistically significant delayed latencies, than in the NH group. In addition, these results demonstrated that the frequency following response peak amplitude was significantly higher in CI recipients, than in the NH counterparts (p<0.05). Finally, the neural phase locking were significantly lower in CI recipients (p<0.05). Conclusions: The findings of sound-field S-ABR demonstrated that CI recipients have neural encoding deficits in temporal and spectral domains at the brainstem level; therefore, the sound-field S-ABR can be considered an efficient clinical procedure to assess the speech process in CI recipients.

능동 조임 마찰 가새로 보강한 단자유도 구조물의 응답 (Vibration Control for a Single Degree of Freedom Structure Using Active Friction Slip Braces)

  • 이진호;아크베이-제카이;김정길;오상균
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.131-138
    • /
    • 2006
  • 일정한 크기의 마찰력을 도입한 가새(FSB)는 에너지를 소산시키는 효과적인 구조 부재이며, 가새의 축력이 마찰력을 넘지 않을 때까지만 탄성 거동을 한다. 본 연구에서는 FSB 개념을 보다 확장시켜서 가새를 죄는 마찰력의 크기를 능동적으로 변화시킬 수 있는 능동 조임 마찰 가새(AFSB)를 착상하여 단자유도 구조물에 적용하고 조화 하중으로 기진시켜 그 거동을 시뮬레이션 하여 FSB와 비교 분석해본다. 이를 위해 간단하고 효과적인 알고리즘을 개발해보았다. 연구 결과, 지반 가속도 값이 그다지 크지 않은 경우, AFSB는 초기에 오우버슈팅이 발생하는 문제만 제외하고 FSB에 비해 효과적으로 진폭과 밑면 전단력을 감소시켰다.

평형곤을 모사한 생체모방형 구동부 일체형 각속도 센서 (Biomimetic Gyroscope Integrated with Actuation Parts of a Robot Inspired by Insect Halteres)

  • 정민기;김지수;장서형;이태재;심형보;고형호;조규진;조동일
    • 제어로봇시스템학회논문지
    • /
    • 제22권9호
    • /
    • pp.705-709
    • /
    • 2016
  • Micro-electro-mechanical systems (MEMS) gyroscopes are widely used in various robot applications. However, these conventional gyroscopes need to vibrate the proof mass using a built-in actuator at a fixed resonance frequency to sense the Coriolis force. When a robot is not moving, the meaningless vibration of the gyroscope wastes power. In addition, this continuous vibration makes the sensor vulnerable to external sound waves with a frequency close to the proof-mass resonance frequency. In this paper, a feasibility study of a new type of gyroscope inspired by insect halteres is presented. In dipterous insects, halteres are a biological gyroscope that measures the Coriolis force. Wing muscles and halteres are mechanically linked, and the halteres oscillate simultaneously with wing beats. The vibrating haltere experiences the Coriolis force if the insect is going through a rotational motion. Inspired by this haltere structure, a gyroscope using a thin mast integrated with a robot actuation mechanism is proposed. The mast vibrates only when the robot is moving without requiring a separate actuator. The Coriolis force of the mast can be measured with an accelerometer installed at the tip of the mast. However, the signal from the accelerometer has multiple frequency components and also can be highly corrupted with noise, such that raw data are not meaningful. This paper also presents a suitable signal processing technique using the amplitude modulation method. The feasibility of the proposed haltere-inspired gyroscope is also experimentally evaluated.

광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정 (Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor)

  • 고재일;정인철;이동희;박신우;황성오;박소미;김기연;주현실;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.

Ku 대역 선형 능동 위상 배열 안테나 시스템 설계 및 실험 (Design and Experiment of Ku_band Linear Active Phased Array Antenna System)

  • 류성욱;엄순영;윤재훈;전순익;김남
    • 한국전자파학회논문지
    • /
    • 제17권7호
    • /
    • pp.694-705
    • /
    • 2006
  • 본 논문은 Ku 위성 방송 대역에서 동작하는 선형 능동 위상 배열 안테나 시스템의 설계 및 실험에 관한 것으로, 안테나 시스템은 16개의 방사 능동 채널 및 16 채널 입력의 윌킨슨 전력 결합기 그리고 안정화 직류 전원 및 위상 제어 보드로 구성된다. 각 능동 채널 내에는 3-비트 디지털 위상 천이기가 존재하여 제어부로부터 위상을 제어 받아 전자적인 안테나 빔을 형성할 수 있다. 측정된 각 능동 채널간의 진폭 및 위상 편차는 각각 ${\pm}0.8dB$ 이하 및 ${\pm}15^{\circ}$ 이하였으며, 각 능동 채널의 잡음 지수는 동작 대역 내에서 1.2 dB 이하의 성능을 갖는다. 전체 안테나 시스템의 측정 성능은 동작 대역 내에서 23.07 dBi 이상의 안테나 이득과 - 11.17 dBc 이하의 사이드로브 레벨 그리고 정방향에서 -12.75 dBc 이하의 교차 편파 레벨을 보여 주었다. 또한, 능동 채널내 위상 제어를 통해 $10^{\circ},\;20^{\circ},\;30^{\circ}$의 빔 스캔 방사 패턴이 측정되었으며, 이때, 각각 1.1 dB, 2.5 dB, 3.6 dB의 빔 스캔 손실 성능을 보여 주었다.

Preparation of Alzheimers Animal Model and Brain Dysfunction Induced by Continuous $\beta$-Amyloid Protein Infusion

  • Akio Itoh;Kiyofumi Yamada;Kim, Hyoung-Chun;Toshitaka Nabeshima
    • Toxicological Research
    • /
    • 제17권
    • /
    • pp.47-57
    • /
    • 2001
  • Alzheimer's disease (AD) is the most common cause of dementia in the elderly, and its pathology is characterized by the presence of numerous numbers of senile plaques and neurofibrillary tangles. Several genetic and transgenic studies have indicated that excess amount of $\beta$-amyloid protein (A$\beta$) is produced by mutations of $\beta$TEX>$\beta$-amyloid precursor protein and causes learning impairment. Moreover, $A\beta$ has a toxic effect on cultured nerve cells. To prepare AD model animals, we have examined continuous (2 weeks) infusion of $A\beta$ into the cerebral ventricle of rats. Continuous infusion of $A\beta$ induces learning impairment in water maze and passive avoidance tasks, and decreases choline acetyltransferase activity in the frontal cortex and hippocampus. Immunohistochemical analysis revealed diffuse depositions of $A\beta$ in the cerebral cortex and hippocampus around the ventricle. Furthermore, the nicotine-evoked release of acetylcholine and dopamine in the frontal cortex/hippocampus and striatum, respectively, is decreased in the $A\beta$-infused group. Perfusion of nicotine (50 $\mu\textrm{M}$) reduced the amplitude of electrically evoked population spikes in the CA1 pyramidal cells of the control group, but not in those of the $A\beta$-infused group, suggesting the impairment of nicotinic signaling in the $A\beta$-infused group. In fact, Kd, but not Bmax, values for [$^3H$] cytisine binding in the hippocampus significantly increased in the $A\beta$-infused rats. suggesting the decrease in affinity of nicotinic acetylcholine receptors. Long-term potentiation (LTP) induced by tetanic stimulations in CA1 pyramidal cells, which is thought to be an essential mechanism underlying learning and memory, was readily observed in the control group, whereas it was impaired in the $A\beta$-infused group. Taken together, these results suggest that $A\beta$ infusion impairs the signal transduction mechanisms via nicotinic acetylcholine receptors. This dysfunction may be responsible, at least in part, for the impairment of LTP induction and may lead to learning and memory impairment. We also found the reduction of glutathione- and Mn-superoxide dismutase-like immunoreactivity in the brains of $A\beta$-infused rats. Administration of antioxidants or nootropics alleviated learning and memory impairment induced by $A\beta$ infusion. We believe that investigation of currently available transgenic and non-transgenic animal models for AD will help to clarify the pathogenic mechanisms and allow assessment of new therapeutic strategies.

  • PDF

상황인식 시 구체 및 비구체적 정보가 의사결정에 미치는 영향: ERP 연구 (The Effects of Specific and Nonspecific Information on Decision Making During Situation Awareness: ERP Study)

  • 류광민;김진구;김우종;임경식
    • 인지과학
    • /
    • 제22권3호
    • /
    • pp.255-270
    • /
    • 2011
  • 본 연구에서는 상황인식 시 구체 및 비구체적 단서가 테니스 선수의 의사결정에 어떠한 영향을 미치는 가를 조사하였다. 피험자는 미국 국가 테니스 등급 프로그램 중 수준이 3-4.5에 해당하는 사람들을 대상으로 하였다. 과제는 피험자가 테니스 단식수비, 단식공격, 복식 수비 랠리 장면을 상황인식하다가 화면이 정지되면 가능한 빨리 예측방향을 예상하여 해당버튼(좌, 중, 우)을 누르는 것이다. 실험설계는 집단(3)${\times}$조건(3)${\times}$영역(7)에 대한 삼원분산분석을 실시하였다. 종속변수는 반응시간, 정확률, P300의 진폭과 잠재기였다. 연구결과 구체적정보 집단과 비구체적 정보 집단이 통제집단보다 P300 잠재기는 짧고, 진폭은 더 큰 것으로 나타났다. 영역에는 Fz, Cz, Pz 영역의 진폭이 크게 나타났으며, 조건 간에는 단식수비조건이 단식공격 그리고 복식수비조건 보다 진폭이 크게 나타났다. 본 연구의 결과 독립변수로 제공된 비구체적 상황인식과 구체적 상황인식 정보는 피험자의 정보처리에 직접적인 영향을 미치는 것으로 나타났다. 또한, 본 연구의 결과는 사건관련전위가 상황인식이나 의사결정 과정을 측정하는 도구로 사용될 수 있다는 것을 보여주었다.

  • PDF

Antispastic Effect of Electroacupuncture on Upper Extremity in Stroke Patients by T-reflex Study : A Single-Blind, Randomized Controlled, Preliminary Study

  • Cho, Min Kyoung;Lee, In;Kwon, Jung Nam;Shin, Byung Cheul;Ko, Sung Hwa;Ko, Hyun Yoon;Shin, Yong Il;Hong, Jin Woo
    • 대한한의학회지
    • /
    • 제36권4호
    • /
    • pp.8-18
    • /
    • 2015
  • Objectives: There have been several studies evaluated effect of electroacupuncture (EA) on spasticity but most studies could not assess spasticity quantitatively because they used clinical rating scales for assessment spasticity. The objective of this study is to evaluate effect of EA on poststroke spasticity quantitatively using tendon reflex (T-reflex). Methods: 29 stroke patients with upper extremity spasticity were randomized to EA group and control group. The EA group received combined EA and rehabilitation therapy 5 times a week for 3 weeks. Acupuncture treatment was given at Jian Yu (LI 15), Qu Chi (LI 11), Shao Hai (HT 3), Wai Guan (TE 5), He Gu (LI 4), Lie Que (LU 7), Hou Xi (SI 3) of the affected side, 30 minutes of electrical stimulation with a frequency of 40/13 Hz was applied at Qu Chi (LI 11), He Gu (LI 4). The control group received only rehabilitation therapy. The efficacy of treatment was assessed using T-reflex latency and amplitude, modified Ashworth scale (MAS) of biceps brachii, brachioradialis and triceps brachii. Fugl-Meyer motor function assessment (FMA) and functional independence measure (FIM) were also measured to assess motor function and functional independence. All outcomes were measured before treatment, immediately after 3 weeks of treatment and 1 week after 3 weeks of treatment. Results: No statistically significant differences were found in outcomes including T-reflex between the study groups except for FIM values immediately after 3 weeks of treatment (p=0.037). Conclusions: These results suggest that 3 weeks of EA does not reduce poststroke upper extremity spasticity electrophysiologically and clinically. However, small sample sizes and contradictory tendency between results from T-reflex and those from MAS require cautious judgement on interpretation of the results. A larger, well-designed clinical trials for quantitative evaluation of effect of EA on poststroke spasticity will be needed.