• 제목/요약/키워드: amplitude control

검색결과 966건 처리시간 0.025초

Power Current Control of a Resonant Vibratory Conveyor Having Electromagnetic Drive

  • Despotovic, Zeljko V.;Ribic, Aleksandar I.;Sinik, Vladimir M.
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.677-688
    • /
    • 2012
  • The vibratory conveyors with electromagnetic drive are used for performing gravimetric flow of granular materials in processing industry. By realizing free vibrations of variable intensity and frequency over a wide range through application of the electromagnetic actuator, suitable power converter, and the corresponding controller, continuous conveyance of granular materials have been provided for various operating conditions. Standard power output stages intended for control of vibratory conveyance using thyristors and triacs. Phase angle control can only accomplish tuning of amplitude oscillations, but oscillation frequency cannot be adjusted by these converters. Application of current controlled transistor converters enables accomplishing the amplitude and/or frequency control. Their use implies the excitation of a vibratory conveyor independent of the supply network frequency. In addition, the frequency control ensures operation in the region of mechanical resonance. Operation in this region is favourable from the energy point of view, since it requires minimal energy consumption. The paper presents a possible solution and advantages of the amplitude-frequency control of vibratory conveyors by means of a current controlled power converter.

A New Approach to Direct Torque Control for Induction Motor Drive Using Amplitude and Angle of the Stator Flux Control

  • Kumsuwan, Yuttana;Premrudeepreechacharn, Suttichai;Toliyat, Hamid A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.79-87
    • /
    • 2008
  • This paper proposes the design and implementation of a direct torque controlled induction motor drive system. The method is based on control of decoupling between amplitude and angle of reference stator flux for determining reference stator voltage vector in generating PWM output voltage for induction motors. The objective is to reduce electromagnetic torque ripple and stator flux droop which result in a decrease in current distortion in steady state condition. In addition, the proposed technique provides simplicity of a control system. The direct torque control is based on the relationship between instantaneous slip angular frequency and rotor angular frequency in adjustment of the reference stator flux angle. The amplitude of the reference stator flux is always kept constant at rated value. Experimental results are illustrated in this paper confirming the capability of the proposed system in regards to such issues as torque and stator flux response, stator phase current distortion both in dynamic and steady state with load variation, and low speed operation.

An Improved Wavelet PWM Technique with Output Voltage Amplitude Control for Single-phase Inverters

  • Zheng, Chun-Fang;Zhang, Bo;Qiu, Dong-Yuan;Zhang, Xiao-Hui;Li, Rui
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1407-1414
    • /
    • 2016
  • Unlike existing pulse-width modulation (PWM) techniques, such as sinusoidal PWM and random PWM, the wavelet PWM (WPWM) technique based on a Harr wavelet function can achieve a high fundamental component for the output voltage, low total harmonic distortion, and simple digital implementation. However, the original WPWM method lacks output voltage control. Thus, the practical application of the WPWM technique is limited. This study proposes an improved WPWM technique that can regulate output voltage amplitude with the addition of a parameter. The relationship between the additional parameter and the output voltage amplitude is analyzed in detail. Experimental results verify that the improved WPWM exhibits output voltage control in addition to all the merits of the WPWM technique.

자동진폭조절 기능을 갖는 CMOS IF VCO 설계 (Design of a CMOS W VCO with Automatic Amplitude Control)

  • 김유환;문요섭;이종렬;박종태;유종근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.145-148
    • /
    • 2002
  • In this paper, a voltage controlled oscillator (VCO) with automatic amplitude control is designed using a 0.35${\mu}{\textrm}{m}$ CMOS process. A cross-coupled PMOS pair is used for a negative resistance to compensate for the losses in the LC resonator, and an automatic\ulcorner amplitude control function is adapted to provide constant output power independent of the Q-factor of the LC resonator. The designed VCO operates in the 200MHz to 550MHz frequency range using different external resonators. The simulated phase noise is -128 dBc/Hz at 100KHz offset from the carrier frequency of 260MHz. It dissipates 0.㎽ from a 3V power supply. The area is 300${\mu}{\textrm}{m}$ x1201${\mu}{\textrm}{m}$.

  • PDF

교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구 (A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF

위상지연필터를 이용한 리니어 모터 피스톤 진폭 추정기의 구현 (Implementation of Linear Motor Piston Amplitude Estimator Using Phase Lag Filter)

  • 오준태;김규식
    • 전자공학회논문지
    • /
    • 제50권4호
    • /
    • pp.212-218
    • /
    • 2013
  • 본 논문에서는 위상지연필터를 이용한 리니어 모터 피스톤 진폭 추정기를 구현하였다. 리니어 컴프레서가 적용된 냉장고나 에어컨의 냉각능력을 제어하기 위해서는 단위시간동안 피스톤의 움직인 거리, 즉 피스톤의 속도를 제어해야 하는데 이때 리니어 모터의 주파수나 스트로크를 조정함으로써 가능하다. 이때, 주파수를 고정하고 스트로크를 변화시키는 것이 일반적이다. 스트로크, 즉 피스톤 진폭을 정확하게 추정하는 것이 리니어 컴프레서의 동특성을 좌우하는데, 본 연구에서는 위상지연필터를 이용한 피스톤 진폭 추정기를 제안하고 성능이 우수함을 모의실험을 통해 확인하였다.

공압제진대용 이중챔버형 공압스프링의 복소강성 모형화 (Amplitude-dependent Complex Stiffness Modeling of Dual-chamber Pneumatic Spring for Pneumatic Vibration Isolation Table)

  • 이정훈;김광준
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.110-122
    • /
    • 2008
  • Pneumatic vibration isolator typically consisting of dual-chamber pneumatic springs and a rigid table are widely employed for proper operation of precision instruments such as optical devices or nano-scale equipments owing to their low stiffness- and high damping-characteristics. As environmental vibration regulations for precision instruments become more stringent, it is required to improve further the isolation performance. In order to facilitate their design optimization or active control, a more accurate mathematical model or complex stiffness is needed. Experimental results we obtained rigorously for a dual-chamber pneumatic spring exhibit significantly amplitude dependent behavior, which cannot be described by linear models in earlier researches. In this paper, an improvement for the complex stiffness model is presented by taking two major considerations. One is to consider the amplitude dependent complex stiffness of diaphragm necessarily employed for prevention of air leakage. The other is to employ a nonlinear model for the air flow in capillary tube connecting the two pneumatic chambers. The proposed amplitude-dependent complex stiffness model which reflects dependency on both frequency and excitation amplitude is shown to be very valid by comparison with the experimental measurements. Such an accurate nonlinear model for the dual-chamber pneumatic springs would contribute to more effective design or control of vibration isolation systems.

제어입력 크기가 제한되는 자기동조 제어알고리즘의 구현에 관한 연구 (Implementation of the Self-tuning Control Algorithm with an Input- amplitude Constraint)

  • 장효환;정회범
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2153-2161
    • /
    • 1993
  • Self-tuning control algorithms for an input-amplitude constrained system are developed and implemented. Magnitude of control input for small motors is generally restricted to narrow bound due to actuator saturation. The gain-adjusted control algorithm and the bounded-gain control algorithm proposed in this study yield smoother control input variations within the magnitude constraints comparing with the existing Clarke's suboptimal control algorithm. In the gain-adjusted control algorithm, the feedforward gain is adjusted using maximum gain, while in the bounded-gain control algorithm, the feedforward gain is bounded using weighting factor. For the DC servo motor control, the system performances of the proposed algorithms are compared with those of the existing algorithm by computer simulation and experiment. It is shown that the input variations of the proposed algorithms are smoother as compared with the existing algorithm.

초음파 반사신호의 복소 진폭을 이용한 교체 내부 결함의 영상 구조 (The image construction of the surface and subsurface defects using complex amplitude of the reflected ultrasonic signals from the solid)

  • 김현;임호;김기열;구길모
    • 정보학연구
    • /
    • 제4권2호
    • /
    • pp.129-136
    • /
    • 2001
  • 초음파현미경은 대부분 단순히 시료로부터 반사된 신호의 진폭만을 이용하여 초음파영상을 구성하였다. 그러나 이 방법은 미세한 변화를 가지는 시료에 대해서는 반사신호의 진폭변화가 민감하지 않음으로 인하여 영상의 질을 저하 시켰다. 본 연구에서는 초음파 반사신호의 진폭과 위상을 동시에 측정할 수 있는 초음파현미경 시스템을 구성하고 샘플로서 500원 주화와 내부에 원형결함이 존재하는 알루미늄 시료에 대해 진폭영상과 위상영상을 획득하고 이들을 상호 비교분석하였다. 실험결과, 위상영상은 미세한 높이변화에 대해서는 진폭영상에 비하여 민감한 반응을 보였고 콘트라스트가 좋은 영상을 얻을 수 있었다. 이와같은 실험결과로 위상영상은 미세변화를 갖는 시료에 대한 비파괴검사시 진폭영상으로 얻어진 영상의 모호성을 개선하는 보조도구로서 활용이 기대된다.

  • PDF

입력제약과 선행신호를 고려한 일반형 예측제어기법 (Generalized predictive control with feedforward and input constraints)

  • 박상현;김창희;이상정
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.327-330
    • /
    • 1996
  • It is well known that the controller output limits have a signifiant effect on the closed loop system performance. Considering the input constraints in GPCF, an effective selection method of the control weighting(.gamma.) is proposed to reduce the amplitude and the rate of control signals so that control signals lie within the limits. It is based on the relation between control weighting(.gamma.) and optimal solution of the unconstrained GPCF. The GPCFIC algorithm chooses an .gamma. at each sampling time so that all unconstrained GPCF output over the control horizon satisfy the rate and the amplitude constraints. In order to evaluate the performance of the GPCFIC, the computer simulations have been done for level control of PWR steam generator in low power operation and shown satisfactory results.

  • PDF