• Title/Summary/Keyword: amplitude and frequency characteristics

Search Result 642, Processing Time 0.029 seconds

Experimental Study on the Characteristics of the Pad Fluttering in a Tilting Pad Journal Bearing (틸팅패드 저어널베어링의 패드 Fluttering 특성에 관한 실험적 연구)

  • 양승헌;하현천;김재실
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.228-234
    • /
    • 2000
  • The vibration characteristics of the pad fluttering in a fluid film tilting pad journal bearing(4-pad LBP) have been investigated experimentally under the different values of oil supply flow rate, bearing load and shaft speed. The vibration characteristics of the pad fluttering are estimated by measuring the time signal of circumferential distribution of the film thickness and the cascade plot of the response of the relative displacement between the bearing and the shaft. It is shown that the vibration frequency of the pad fluttering has a sub-synchronous frequency and 31mos1 does not change by the increase of shaft speed. However the vibration amplitude is increased by the increase of shaft speed. From those experimental results, pad fluttering can be thought of as a self-excited vibration. The incipient pad fluttering velocity is increased by the increase of oil supply rate and by the decrease of bearing load. It is observed that the vibration amplitude of the pad fluttering can be decreased by the control of supply oil flow rate effectively. And also It is known that the outbreak of pad fluttering does not concern with the shaft vibration.

  • PDF

Research for the Effect of Accumulator and the High Frequency-Hydraulic System of Frequency Characteristics by Experimental Method (고주파 유압시스템의 주파수 특성과 축압기 효과의 실험적 연구)

  • Park, Nam-Eun;Kim, Jae-Soo;Kim, Yang-Soo;Kim, Jong-Rok;Rho, Hyung-Woon;Jeon, Seung-Bae;Na, Hong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.51-57
    • /
    • 2003
  • Characteristics of the high frequency pulsatile flow have been investigated experimentally to understand the flow phenomena in the hydraulic system. One axis fatigue test bed, which is widely used for automobile field test, is used. Four pressure transducers, an amplifier and a A/D convertor are used to obtain the high frequency pulsatile pressure waveform in hydraulic system. The characteristics of frequency are analyzed by power spectrum method. According to the variations of pump input pressure and actuator acceleration frequency, the pressure is measured with or without an accumulator. The amplitude of pressure with accumulator is very lower than those without accumulator due to absorbing function of accumulator. As the frequency of actuator acceleration is increased, the effect of accumulator become very important to decrease the amplitude of pulsatile pressure waveform with high frequencies.

Viscoelastic properties of electrorheological fluids (전기유변유체의 점탄성 특성에 관한연구)

  • Choe, Yun-Dae;Kim, Sang-Guk
    • Korean Journal of Materials Research
    • /
    • v.2 no.3
    • /
    • pp.220-227
    • /
    • 1992
  • Electrorheological(ER) fluid's storage shear modulus(G') and loss factor(${\eta}$) have been directly measured using small amplitude forced oscillating rheometer as a function of oscillating frequency, strain amplitude and applied electric field. Two types of experiment were performed , (a) frequency sweep and (b) amplitude sweep. Two kinds of sample were employed for this experiment ; cornstarch particles in corn oil and zeolite particles in silicone oil. The storage shear modulus was a strong function of driving frequency. Generally, the modulus increased with driving frequency. On the other hand, the loss factor was not well behaved as storage modulus, but as the driving frequency increases the loss factor slightly decreases was the trend of the material's characteristics. Also the modulus was a strong function of strain amplitude. Generally, modulus decreased with increasing strain, but loss factor increases slightly with increasing strain amplitude. For G', cornstarch in corn oil ER fluid has higher values than zeolite based fluid as we increased applied electric field. On the other hand, zeolite based fluid has higher values for ${\eta}$. There is a reasonable agreement between theoretical calculation and experiment.

  • PDF

Study on improvement of frequency response characteristics of accelerometer (진동가속도계의 주파수응답특성 개선에 관한 연구)

  • 한응교;조진호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.61-68
    • /
    • 1981
  • There are three types in frequency response accelerometer; one is lightly damped piezp type, another is oil damping stainguage type and the third is electro induction type accelerometer within electromagnetic damping. The usable frequency range of lightly damped accelerometers is limited to 0.2 of their mounted natural frequency for amplitude distortion of less than 5 percents. There have been situation where the measured motion contains unforeseen high - frequency components, which are regarded as such due to the accelerometer transfer function. There are several way to overcome amplitude distortion of the higher than anticipated frequency components; (I) to make use of the accelerometer with natural frequency three times and more as high as the measured frequency, (II) to establish data-analysis techniques which will account for the amplitude distortion, (III) to set up a notch filter circuit which has a transfer function that is the reciprocal of the accelerometer transfer function, and so on. This paper makes a report of the method as to(III), i. e., set up a few notch filter circuits, it is discussed what happens when the transfer functions, are in discord as to natural frequency of the filter and accelerometer damping vs. filter damping. And especially as for the cantilever strain gauge type accelerometer made by oneself with ease, it was compared and discussed between the ideological value and the experimental value of actual designed circuit in case of the mismatching of the transfer functions, and it was considered whether to be practicable or not, the result of which was as following; the useful frequency range of the accelerometer can be extended to near resonance if (a) the accelerometer mounted natural frequency and the filter center frequency are matched within .+-. 2 percent and (b) the damping ratios are matched within two factors. Therefore, we obtained the good result in improvement for extending frequency response characteristics of accelerometer.

  • PDF

Diagnosis of Optical FSK Transmitter Output Characteristics Using Michelson Interferometer (Michelson 간섭계를 이용한 광 FSK 송신기 특성검출)

  • 박상영;이규송;임호근;전광석;김창민;홍완혜
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.10
    • /
    • pp.806-813
    • /
    • 1991
  • In this paper, we suggested the diagnosis of the optical FSK transmitter output characteristics using the Micheloson interferometer. The transmitter is designed by the direct frequency modulation effect of a semoconductor laser diode. The optical FSK transmitter consists of a temperature stabilized semiconductor laser diode and an optimally designed equalizer. It is modulated by 100Mbit/s PRBS Generator to diagonosis of Optical FSK transmitter output characteristics. The Michelson Interferometer is used for the optical frequency discriminator which transforms the output frequency of the transmitter to the amplitude of light. The measurement of the performance of the transmitter to the amplitude of light. The measurement of the performance of the transmitter computer the transmitted data and their eye pattern with the simulation results, the received data and their eye pattern. As the result of experiment, the data transfer rate of the transmitters is 100Mbit/s.

  • PDF

Characteristics of Acoustic Emission by Expansive Cement Induced Rock Fractures (팽창성 시멘트에 의한 암석균열시의 AE 특성)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 1998
  • A study was conducted to determine the characteristics of acoustic emission(AE) events generated by the expansive cement induced rock fracturing. The dominant frequency and the maximum amplitude of the AE events are changed in relation to the rate of expansive pressure development in the hole. The dominant frequencies are in the range of 150∼230kHz for the small hole tests and 400∼500kHz for the large hole test. The maximum amplitudes are in the range of 0.015∼0.050cm/sec and 0.025∼0.064cm/sec, respectively. The fact that AE events of higher amplitude with higher frequency on the large hole test and lower amplitude with lower frequency on the small hole tests were detected, may strongly imply that the amount of energy consumed for a macro-crack in both tests may be similar. The expansive cement induced crack propagates stably without any distinguished event having higher amplitude and this implies that a macro-crack is a result of stable growth of micro cracks.

  • PDF

Numerical Analysis of the Unsteady Subsonic Flow around a Plunging Airfoil

  • Lee, Kyungwhan;Kim, Jaesoo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2013
  • Much numerical and experimental research has been done for the flow around an oscillating airfoil. The main research topics are vortex shedding, dynamic stall phenomenon, MAV's lift and thrust generation. Until now, researches mainly have been concentrated on analyzing the wake flow for the variation of frequency and amplitude at a low angle of attack. In this study, wake structures and acoustic wave propagation characteristics were studied for a plunging airfoil at high angle of attack. The governing equations are the Navier-Stokes equation with LES turbulence model. OHOC (Optimized High-Order Compact) scheme and 4th order Runge-Kutta method were used. The Mach number is 0.3, the Reynolds number is, and the angle of attack is from $20^{\circ}$ to $50^{\circ}$. The plunging frequency and the amplitude are from 0.05 to 0.15, and from 0.1 to 0.2, respectively. Due to the high resolution numerical method, wake vortex shedding and pressure wave propagation process, as well as the propagation characteristics of acoustic waves can be simulated. The results of frequency analysis show that the flow has the mixed characteristics of the forced plunging frequency and the vortex shedding frequency at high angle of attack.

The development of IF amplifier having low noise and wide AGC range (저잡음 및 넓은 자동 이득 제어 영역을 갖는 IF 증폭기의 설계)

  • 이흥배;엄두찬;김용석;정연철
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.10
    • /
    • pp.73-81
    • /
    • 1994
  • It is AGC(Automatic Gain Control) amplifier to decide characteristics of IF(Intermediate Frequency) processing IC. When demodulated IF signal by PLL type demodulator, the amplitude of input singla should be maintained at a certain amplitude. The AGC amplifier is an important factor to achieve this condition. The AGC amplifier needs the wide dynamic range, the wide AGC range and better noise characteristics. We designed the AGC amplifier to satisfy these characteristics.

  • PDF

A Study on Dynamic Behavior of a Rotor-Bearing System Under External Disturbances (외란을 받는 축-베어링 시스템의 동적 거동에 대한 연구)

  • Rho, Byoung-Hoo;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2002
  • The nonlinear vibration characteristics of hydrodynamic journal bearings with a circumferential groove we analyzed numerically when the external sinusoidal disturbances are given to the rotor-bearing system continuously. Furthermore, a cavitation algorithm, implementing the Jakobsson-Floberg-Olsson boundary condition, is adopted to predict cavitation regions in a fluid film more accurately than the conventional analysis. which uses the Reynolds boundary condition. It is found that the difference between linear and nonlinear analysis is much more remarkable as the amplitude of external disturbance increases, and it depends upon the excitation frequency of the external disturbance. It is also shown that the cavity region in the fluid film increases as the amplitude or excitation frequency of the external disturbance increases. The whirling center of the steady state orbit moves closer to the bearing center as the amplitude or excitation frequency of the external disturbance increases.

A Numerical Study on the Flow Characteristics of a Valveless Micropump (무밸브 마이크로 펌프의 유동 특성에 관한 수치해석)

  • Chin, Sang-Mun;Hur, Nahmkeon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.748-753
    • /
    • 2004
  • The performance of a valveless micropump driven by chamber wall oscillation was numerically investigated for various frequency and amplitude of the oscillation. The numerical study was performed in the range of oscillation frequency from 200Hz to 1000Hz and amplitude from $1{\mu}m$ to $15{\mu}m$. And optimal values for the parameters are found. At the oscillation frequency 600Hz, the net flow rate of micropump shows a maximum value. Also the results show good agreement with the experimental results. The total flow rate was increased with the oscillation amplitude. However, the net flow rate was found to be decreased over $7{\mu}m$.

  • PDF