• Title/Summary/Keyword: amount of water

Search Result 7,139, Processing Time 0.039 seconds

A Study of the Physical Characteristics of Backsulgi by the Amount of Water and Some Kinds of Sweeteners (당의 종류와 물의 첨가량에 따른 백설기의 물리적 특성에 관한 연구)

  • Yoo, Ahe-Ryoung;Lee, Hyo-Gee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.13 no.4
    • /
    • pp.381-388
    • /
    • 1984
  • The objective of this study was to evaluate the effect of the amount of water and several kinds of sweeteners on the texture such as grain appearance, softness, moistness, chewiness, cohesiveness, gumminess and elasticity of Backsulgi when one manufactures Backsulgi. Different amount of water of 30 ml, 60 ml and 90 ml/350 g of powdered rice and such sweetners as sugar, honey and syrup were employed for the experimental treatments. The evaluation of these results were dependent on statistical data of some scores that were obtained through sensory evaluation and Instron Universal Testing Machine. According to this sensory evaluation, the texture of Backsulgi was more affected by the change of water quantity than that of sweeteners. Judging from the results of Instron Universal Testing Machine, it was found that there were no statistically significant differences in each treatment of the cohesiveness, elasticity and hardness of Backsulgi, but some statistically significant difference was observed in each treatment of the gumminess and chewiness of Backsulgi(p<0.05).

  • PDF

Fishing capacity and bycatch on spring net pot for conger eel by entrance size (스프링그물통발의 입구 크기에 따른 붕장어 어획성능과 혼획)

  • SONG, Dae-Ho;CHO, Sam-Kwang;CHA, Bong-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.1
    • /
    • pp.9-16
    • /
    • 2016
  • This study was conducted to analyze fishing capacity and bycatch by mesh size and entrance size of spring net pot conducted by water tank and field experiment. The water tank experiments were conducted by using traps with mesh size of 22 mm and entrance size of 120 mm and 140 mm, respectively in the water tank of NIFS. The field experiment was conducted using 5 kinds of spring net pot with mesh sizes of 20 mm, 22 mm, 35 mm and entrance size of 120 mm, 130 mm, 140 mm, 360 mm by coastal trap fishery vessel operating around the area of Geoje island. In the result of water tank experiments, the catch of conger eel was 1.5 times higher when using trap with entrance size of 140 mm than that of 120 mm. In the field experiment, when using same mesh size, the larger the entrance size, the higher amount of conger eel catch, bycatch and number of bycatch species. When using the same entrance size, the larger the mesh size, the lower amount of conger eel catch and number of bycatch species, whereas the amount of bycatch showed increasing trend.

A Study on Phosphorus Loading model for Eutrophication Response in the Yongsan Lake (영산호의 부영양화 평가를 위한 인부하모델의 검토)

  • 류일광;이치영
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.97-104
    • /
    • 2000
  • The purpose of this is made an examination of phosphorus loading model for eutrophication response in the Yongsan lake. For the model, we measured the total amount of nutrients derived from the Yongsan river watershed, inflow rate to the Yongsan lake, water quality, and water budget from January to December in 1999. The total amount of precipitation in the Yongsan river watershed was 4,951.7$\times$10$^{6}$ ㎥/y and inflow amount was 2,569.7$\times$10$^{6}$ ㎥/y, therefore the outflow rate of the Yongsan river watershed was 51.9%. The develop loading of total nitrogen was 86,928.1kg/d and that of total phosphorus was 22,007.6kg/d at the Yongsan river watershed, But, as the inflow loading of total nitrogen was 33,962kg/d and the inflow loading of total phosphorus was 2,218kg/d to the Yongsan lake. so each infolw rate was 39.0% and 10.1%. The hydraulic residence time was 34days, total phosphorus loading [L(P)] on the surface area was 23.398g/㎥/y, the hydraulic load( $Q_{s}$) of inflow water was 74.269m/y, the reserve rate of phosphorus in the lake was 0.359, and the settinh velocity of phosphorus was 0.114m/d at the Yongsan lake. Mathematical model of phosphorus loading to estimate the responses of eutrophication at the Yongsan lake is [ $P_{j}$] = 0.838 [L(P)/Q.(1+√ $T_{w}$)$^{-1}$ ] . ] . .

  • PDF

Decomposition of PVC and Ion exchange resin in supercritical water

  • Lee, Sang-Hwan;Yasuyo, Hosgujawa;Kim, Jung-Sung;Park, Yoon-Yul;Hiroshi, Tomiyasu
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2005.05a
    • /
    • pp.267-271
    • /
    • 2005
  • This experiment was carried out at 450"C, which is relatively lower than the temperature for supercritical water oxidation (600-650$^{\circ}C$). In this experiment, the decomposition rates of various incombustible organic substances were very high. In addition, it was confirmed that hetero atoms existed in organic compounds and chlorine was neutralized by sodium(salt formation).However, to raise the decomposition rate, relatively large amount of sodium nitrate(3-4 times the equivalent weight) was required. When complete oxidation is intended as in the case with PCB, the amount of oxidizer and decomposition cost is important. But when vaporization reduction is required as in the case with nuclear wastes, the amount of radioactive wastes increases instead. But as can be seen in the result of XRD measurement, unreacted sodium nitrate remained unchanged. If oxidation reaction of organic substance simply depends on collision frequency, unreacted sodium nitrate can be recovered and reused, then oxidation equivalent weight would be sufficient. In the gas generated, toxic gas was not found. As the supercritical water medium has high reactivity, it is difficult to generate relatively low energy level SO$_{X}$, and NO$_{X}$.

  • PDF

Effects of Various Parameters on Biodegradation of Degradable Polymers in Soil

  • Shin, Pyong-Kyun;Jung, Eun-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.6
    • /
    • pp.784-788
    • /
    • 1999
  • The effects of pH, moisture content, and the relative amount of a polymer sample on the biodegradation of degradable polymers in soil were studied using various polymer materials such as cellulose, poly-(butylene succinate-co-adipate) (SG) polycaprolactone (PCL), a blend of PCL and starch (PCL-starch), and a poly-lactic acid (PLA). As with other materials, the polymers degraded faster at a neutral pH than at either acidic or basic conditions. Moisture contents of 60 and 100% water holding capacity exhibited a similar biodegradability for various polymers, although the effects differed depending on the polymer. For synthetic polymers, biodegradation was faster at 60%, while the natural polymer (cellulose) degraded faster at 100%. Fungal hypae was observed at a 60% water holding capacity which may have affected the biodegradation of the polymers. A polymer amount of 0.25% to soil revealed the highest biodegradability among the ratios of 0.25, 0.5, and 1%. With a higher sample amount, the residual polymer could be recovered after the biodegradation test. It was confirmed that a test for general biodegradation condition can be applied to plastic biodegradation in soil.

  • PDF

Assessment of Water Balance Considering Runoff Characteristics in the Mountainous Area of Pyosun Catchment in Jeju Island (유출특성을 고려한 산지지역의 물수지 평가 - 제주도 표선유역을 중심으로 -)

  • Song, Sung-Ho;An, Jung-Gi;Lee, Gyu-Sang
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.505-514
    • /
    • 2015
  • The grid-based water balance of watershed scale was assessed in the mountainous area of Pyosun catchment in Jeju Island after analyzing precipitation, evapotranspiration, and runoff from January 2008 to December 2013. The existing results of direct runoff, evapotranspirtion, and groundwater recharge comparing to precipitation were presented 22.0%, 25.6%, and 52.4%, respectively, in Pyosun catchment. However, this study indicated each component shows 14.5%, 24.2%, and 61.0%, respectively, in the mountainous area of Pyosun catchment. Therefore, groundwater recharge rate in the mountainous area appears higher than 10% comparing to the overall catchment. It would be analyzed that the amount of direct runoff is relatively small. Moreover, this difference could be generated because of the spatial discontinuities in the process of estimating the total amount of precipitation in the mountainous area. Therefore, the grid-based spatial analysis to maximize the spatial continuity would be useful for providing a more reasonable result when the total amount of water resources are evaluated in mountainous areas in the future.

Fundamental study on the evapo-transpiration requirements of paddy rice plant (수도용수량계획상의 엽면증발량 및 주간수면증발량에 관한 기초적인 연구)

  • 김철기
    • Journal of the Korean Professional Engineers Association
    • /
    • v.2 no.6_7
    • /
    • pp.12-23
    • /
    • 1969
  • The purpose of this study is to find out the reasonable amount of evapo-transpiration required for the paddy rice plant during the whole growing season. So, on the basis of the 3year experimental data concerning the evapo-transpiration from 1966 to 1968, the author obtained the following results. 1) The leaf area index in the densely planted plot is generally higher than that in the conventionally planted one during the first half of growing season. So, the coefficient of transpiration in the former plot is some what higher than in the latter, and the coefficient of water surface evaporation under the plant cover has the inverse relation between both plots. 2) It is unreasonable that coefficient of evapo-transpiration is applied to the calculation of the evapo-transpiration requirments of each growing stage, because a certain degree of variation in meteorological factors and in the thickness of the plant growth is involved in it. 3) It is most reasonable that the rate of transpiration and of the water surface evaporation is applied to the calculation of the transpirated amount and evaporated one in each growing stage because it shows almost constant value in spite of any meteorological conditions in so far as the variety of rice, planted density and control of applying fertilizer are same and the disease and blight are negligible. 4) The ratio of the amount of transpiration to the weight of the whole air dried yields has the tendency of decreasing as that of the yields increase, having almost constant value despite the amount of pan evaporation; and the value is about 210 when the weight of root parts is included to that of the yields. 5) Although the required amount of transpiration during the whole growing season can be calculated with the above ratio, fig. 7 showing the relation between the amount of transpiration and the weight of the yields is more reasonable and will be convinient to find it. And the requirements of water surface evaporation during the same season can also be directly found with the weight of air dried straw refering to fig.8.

  • PDF

Estimation of Optimal Hydro-Power Supply Amount of Yongdam Multipurpose Dam for the Contract on the Free-Competition Market (자유경쟁 시장 내에서 용담다목적댐 발전소의 최적 계약가능 공급량 평가)

  • Yoo, Ju-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.1
    • /
    • pp.25-35
    • /
    • 2005
  • Nowaday the amount of water resource to generate the hydro-power energy has decreased as that of the water supply has increased. In case that the national market of the energy will be in free competition, the energy producer need to suggest the amount of the optimal supply with the hydrological reliability for a deal. In this study the optimal reservoir operation was performed by the linear programming and the optimal reliabilities of inflows and the power supply were obtained by the one dimensional search technique to estimate the energy with the optimal inflow reliability which the power system of the Yongdam multipurpose dam in Geum river can produce. And the main results were presented.

A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System (지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구)

  • Kang, Shin-Hyung;Lee, Kwang Ho;Do, Sung Lok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.2
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

A Study on the Seawater Filtration Characteristics of Single and Dual-filter Layer Well by Field Test (현장실증시험에 의한 단일 및 이중필터층 우물의 해수 여과 특성 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.51-68
    • /
    • 2019
  • This study performs to evaluate adaptability of seashore filtering type seawater-intake which adapts dua1 filter well alternative for direct seawater-intake. This study varies filter condition of seashore free surface aquifer which is composed of sand layer then installs real size dual filter well and single filter well to evaluate water permeability and proper pumping amount according to filter condition. According to result of step aquifer test, it is analysed that 110.3% synergy effect of water permeability coefficient is happened compare to single filter since dual filter well has better improvement. dual filter has higher water permeability coefficient compare to same pumping amount, this means dual filter has more improved water permeability than single filter. According to analysis result of continuous aquifer test, it is evaluated that dual filter well (SD1200) has higher water permeability than single filter well (SS800) by analysis of water permeability coefficient using monitoring well and gauging well, it is also analysed dual filter has 110.7% synergy effect of water permeability coefficient. As a evaluation result of pumping amount according to analysis of water level dropping rate, it is analysed that dual filter well increased 122.8% pumping amount compare to single filter well when water level dropping is 2.0 m. As a result of calculating proper pumping amount using water level dropping rate, it is analysed that dual filter well shows 136.0% higher pumping amount compare to single filter well. It is evaluated that proper pumping amount has 122.8~160% improvement compare to single filter, pumping amount improvement rate is 139.6% compare to averaged single filter. In other words, about 40% water intake efficiency can be improved by just installation of dual filter compare to normal well. Proper pumping amount of dual filter well using inflection point is 2843.3 L/min and it is evaluated that daily seawater intake amount is about $4,100m^3/day$ (${\fallingdotseq}4094.3m^3/day$) in one hole of dual filter well. Since it is possible to intake plenty of water in one hole, higher adaptability is anticipated. In case of intaking seawater using dual filter well, no worries regarding damages on facilities caused by natural disaster such as severe weather or typhoon, improvement of pollution is anticipated due to seashore sand layer acts like filter. Therefore, It can be alternative of environmental issue for existing seawater intake technique, can save maintenance expenses related to installation fee or damages and has excellent adaptability in economic aspect. The result of this study will be utilized as a basic data of site demonstration test for adaptation of riverside filtered water of upcoming dual filter well and this study is also anticipated to present standard of well design and construction related to riverside filter and seashore filter technique.