• 제목/요약/키워드: ambient cold

검색결과 169건 처리시간 0.025초

Transient Characteristics of a Two-Phase Thermosyphon Loop for Multichip Module

  • Nam, Sang-Sig;Choi, Sung-Bong;Kim, Jae-Hee;Kwak, Ho-Young
    • ETRI Journal
    • /
    • 제20권3호
    • /
    • pp.284-300
    • /
    • 1998
  • A new thermosyphon cooling module (TSCM) has designed, fabricated and tested to cool the multi-chip module consists of a cold plate and an integrated condenser. With an allowable temperature rise of $56^{\circ}C$ on the surface of the heater, the cooling module TSCM can handle a heat flux of about 2.7 $W/cm^2$ using R11 as working fluid. The transient characteristics of the cooling module have been proved to be excellent: that is, when a heat load is applied inside of the system, steady state can be achieved within 10 to 15 minutes. It has been found that the length of the vapor channel between the cold plate and the condenser in addition to the ambient and the condenser temperatures affect the system performance.

  • PDF

마이크로 노즐 성능평가 (Performance test of micronozzle)

  • 문성환;오화영;허환일
    • 한국항공우주학회지
    • /
    • 제33권5호
    • /
    • pp.72-78
    • /
    • 2005
  • 대기압 하에서 노즐목 직경이 1.0, 0.5, 0.25 mm인 마이크로노즐을 이용하여 성능시험을 하였다. 냉가스 추진제로는 질소를 사용하였다. 성능평가를 위하여 챔버내 전압력을 2~20 bar까지 변화시키면서 추력과 질유량을 측정하였다. 실험결과 압력이 낮아질수록 점성에 의한 손실이 크다는 것을 비추력을 비교해 봄으로써 알 수 있었다. 그리고 오리피스와 노즐의 추력 비교를 통해 노즐의 효율의 더 좋다는 것을 확인할 수 있었다.

서울시 대기 중 $H_2O_2$의 농도 (Hydrogen Peroxide Concentrations in Air in Seoul)

  • 강충민;김희강
    • 한국대기환경학회지
    • /
    • 제16권1호
    • /
    • pp.61-68
    • /
    • 2000
  • Gas-phase hydrogen peroxide(H2O2) concentrations were measured to investigate it's distribution in the ambient air in downtown Seoul(Kwanghwamum and Mullae-dong). These measurements were made during four season, from April 30, 1998 to January 29, 1999, using Cold Trap and HPLC. Measurements were also made of other photochemical oxidants and trace gases(O3, NO2, CO and SO2) and meteorological parameters(relative humidity, temperature, solar radiation and wind speed). The mean of all observations was 0.10 ppbv and the range measured was below the level of detection(>0.01 ppbv) to 0.47ppbv. The higher seasonal mean concentrations showed during the summer(0.21 ppbv) and concentrations of H2O2 showed a diurnal variation with maximum concentrations in the afternoon(12:30∼14:00). The results from the corrrelation analysis showed that the concentration of gaseous H2O2 is strongly dependent on the other air pollutants(NO2, CO and O3) and meteorological parameters(relative humidity, temperature and solar radiation.)

  • PDF

외기 온도와 난방 출력의 철도차량 객실 온도에 대한 영향 연구 (Study of the Effects of Ambient Temperature and Car Heater Power on the Train Cabin Temperature)

  • 조영민;박덕신;권순박;정우성
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5877-5884
    • /
    • 2014
  • 최근 기후변화와 기상이변 등으로 동절기에 더욱 가혹한 기상 조건이 자주 보고되고 있다. 그러나, 철도차량의 난방용량은 이렇게 극도로 추운 기후환경에서는 객실을 난방하기에 충분하지 않은 경우가 많으며, 이는 난방에 대한 승객의 민원을 야기하는 주요 원인이 되고 있다. 본 연구에서는 외기 온도와 난방 출력이 객실 온도에 미치는 영향을 알아봄으로써 차량의 난방용량에 따른 운행 가능한 외기온도를 실험적으로 도출하고자 하였다. 실험방법으로는 우선 시험용 철도차량을 대형 기후환경 챔버에 넣고, 다양한 외기온도조건을 모사하였다. 난방 장치 출력의 영향은 난방 장치의 출력을 변화시키면서 객실의 온도를 측정하여 조사하였다. 외기온도가 $-10^{\circ}C$인 조건에서는 난방기의 출력을 최대로 한 경우에도 객실의 평균 온도는 $14.0^{\circ}C$에 불과하여, 동절기의 객실온도 최소 요구조건인 $18^{\circ}C$보다 훨씬 낮았으나, 외기 온도가 $0^{\circ}C$$10^{\circ}C$인 경우의 객실온도는 각각 $26.1^{\circ}C$$34.0^{\circ}C$였다. 내삽법으로 계산한 결과 객실 내부 온도를 $18^{\circ}C$ 이상으로 유지할 수 있는 최저 외기온도는 $-6.7^{\circ}C$임을 알 수 있었다. 객실 내부에서의 수직 온도 차이는 난방기 출력이 높을수록, 외기온도가 높을수록 커서 10 K 이상 차이가 나는 경우도 있었다. 그러나, 수평 온도 차이는 난방기 출력이나 외기온도에 무관하게 최대 2 K 이하로 매우 낮게 나타났다. 따라서, 우수한 난방성능을 확보하기 위해서는 수직 온도 차이를 줄이는 것이 중요함을 알 수 있었다.

냉가스 추진장치를 이용한 마이크로 노즐의 성능평가 (Performance Evaluation of Micro-nozzle Using Cold Gas Propulsion System)

  • 정성철;김연호;오화영;명노신;허환일
    • 한국추진공학회지
    • /
    • 제11권6호
    • /
    • pp.42-49
    • /
    • 2007
  • 본 연구에서는 마이크로 추진장치의 개발을 위한 기초연구로 마이크로 노즐의 유동 특성을 분석하였다. 냉가스 추진원리를 이용하였으며, 추진 장치의 노즐 목 직경이 1.0, 0.5, 0.25 mm 인 마이크로 노즐을 방전가공을 이용하여 제작하였다. 판스프링과 스트레인 게이지를 이용한 추력측정장치를 이용하여 추력을 측정하였으며, 대기압 환경과 진공환경에서 마이크로 노즐의 유동특성을 분석하였다. 추진제는 아르곤과 질소를 사용하였으며, 실험 결과를 CFD 결과와 비교하였다. 연구 결과 노즐의 소형화로 인해 점성과 배압에 의한 유동손실이 발생함을 확인할 수 있었다.

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

Chemical Imprints of the Upwelled Waters off the Coast of the Southern East Sea of Korea

  • Lee, Tong-Sup;Kim, Il-Nam
    • Journal of the korean society of oceanography
    • /
    • 제38권3호
    • /
    • pp.101-110
    • /
    • 2003
  • We made intensive observations on the coastal upwelling off the coast of the southern East Sea from June to August in 2001. The upwelling exhibited a weekly waxing and waning. The coastal upwelling of the year 2001 was characterized by abrupt outbreaks and the small local scale. Upwelling occurred more frequently off the coast of Ulsan and Gampo as reported by the earlier observers. The spread of freshly upwelled colder water was varied by each upwelling event. Generally cold waters were carried away northeastward off Pohang province. The upwelled cold waters were saltier than the resident surface waters. The pH and salinity-normalized alkalinity support the idea that the upwelled waters originate from the interior of the East Sea. The extraordinarily high concentration of dissolved oxygen suggests that the upwelled waters are closely connected to the southward flowing North Korea Cold Current. Although a lower primary productivity was reported for the upwelling region, underway surface fluorescence measurement revealed that the recently upwelled waters supported up to an order of magnitude higher algal biomass than the ambient waters. Because thermohaline circulation of the East Sea is so vigorous, with an estimated time scale of less than one hundred years, that the coastal upwelling should be considered not as an anomaly but as a regular component of a circulatory system. A quantitative understanding of upwelling seems to be a key to elucidate material cycling and the associated biological production in the East Sea.

Urea Kinetics in Wethers Exposed to Different Ambient Temperatures at Three Dietary Levels of Crude Protein

  • Sun, Sang-Soo;Christopherson, Robert J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권6호
    • /
    • pp.795-801
    • /
    • 2005
  • Eighteen Suffolk wether lambs (BW = 24 kg) were chronically exposed to temperatures of cold (2$^{\circ}C$) or warm (22$^{\circ}C$). The experimental design consisted of a 2${\times}$3 factorial with a single crossover of environment treatment. The sheep were closely shorn and were housed in individual metabolic crates in controlled environment rooms. Sheep consumed pelleted diets ad libitum, which consisted of mainly barley grain and brome grass, and diets contained 7, 11 or 14% crude protein (CP). Animals were catheterized via one jugular vein with a PVC catheter and received a single injection of 60-65 Ci of $^{14}$C]urea. Plasma urea-N (PUN), urinary urea (UU), and carbon specific radioactivity were measured. Urea metabolism was not affected by environment. Percent urea recycling and urea space clearance were highest (p<0.05) on the low nitrogen diet. Urea pool was increased (p<0.10) for the 14% CP diet. Both UU and PUN concentration were positively related (p<0.01) with diet CP content. Therefore, dietary CP content significantly influenced urea metabolism, however, cold exposure did not alter those parameters.

액화천연가스의 냉열을 이용한 가스터빈의 성능향상 (Improvement of Gas Turbine Performance Using LNG Cold Energy)

  • 김동섭;노승탁;이우일;최만수;고상근
    • 대한기계학회논문집B
    • /
    • 제23권5호
    • /
    • pp.653-660
    • /
    • 1999
  • This work describes analysis on the effect of inlet air cooling by the cold energy of liquefied natural gas(LNG) on the performance of gas turbines. Gas turbine off-design analysis program to simulate the influence of compressor inlet temperature variation is prepared and an inlet air cooler is modeled. It is shown that the degree of power augmentation is much affected by the humidity of inlet air. If the humidity is low enough, that is the water content of the air does not condense, the temperature drop amounts to $18^{\circ}C$, which corresponds to more than 12% power increase, in case of a $1350^{\circ}C$ class gas turbine with methane as the fuel. Even with 60% humidity, about 8% power increase is possible. It is found that even though the fuel contains as much as 20% ethane in addition to methane, the power improvement does not change considerably. It is observed that if the humidity is not too high, the current system is feasible oven with conceivable air pressure loss at the inlet air cooler.

도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로- (Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants -)

  • 백성옥;김윤신
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF