• Title/Summary/Keyword: ambient cold

Search Result 169, Processing Time 0.025 seconds

Flexural-torsional buckling tests of cold-formed steel compression members at elevated temperatures

  • Heva, Yasintha Bandula;Mahendran, Mahen
    • Steel and Composite Structures
    • /
    • v.14 no.3
    • /
    • pp.205-227
    • /
    • 2013
  • Current design standards do not provide adequate guidelines for the fire design of cold-formed steel compression members subject to flexural-torsional buckling. Eurocode 3 Part 1.2 (2005) recommends the same fire design guidelines for both hot-rolled and cold-formed steel compression members subject to flexural-torsional buckling although considerable behavioural differences exist between cold-formed and hot-rolled steel members. Past research has recommended the use of ambient temperature cold-formed steel design rules for the fire design of cold-formed steel compression members provided appropriately reduced mechanical properties are used at elevated temperatures. To assess the accuracy of flexural-torsional buckling design rules in both ambient temperature cold-formed steel design and fire design standards, an experimental study of slender cold-formed steel compression members was undertaken at both ambient and elevated temperatures. This paper presents the details of this experimental study, its results, and their comparison with the predictions from the current design rules. It was found that the current ambient temperature design rules are conservative while the fire design rules are overly conservative. Suitable recommendations have been made in relation to the currently available design rules for flexural-torsional buckling including methods of improvement. Most importantly, this paper has addressed the lack of experimental results for slender cold-formed steel columns at elevated temperatures.

Dependence of Round Type Electrodeless Lamp according to Ferrite Core and Cold Spot Temperature (둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Kim, Nam-Goon;Jung, Young-Il;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1078-1083
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature.

Dependence of Round Type Electrodeless Lamp According to Ferrite Core and Cold Spot Temperature (둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Jong-Chan;Han, Hoo-Sek;Park, Jee-Sik;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.833-838
    • /
    • 2008
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature. Additionally, spectrum, color temperature and coordination are measured to check that is relation with ambient temperature.

Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles (축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

Dependence of Round type electrodeless lamp according to ferrite core and cold spot temperature (둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성)

  • Oh, Seul-Yi;Kim, Nam-Goon;Yang, Jong-Kyung;Jung, Young-Il;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04a
    • /
    • pp.65-69
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of electrodeless lamp are related to ferrite core and cold spot temperature.

  • PDF

Changes in Moisture Content and Quality of Oriental Hybrid Lily (Lilium oriental cv. Siberia) Cut Flowers during Storage at Cold and Dry Condition and Subsequent Exposure to Ambient Temperature (오리엔탈 나리 '시베리아' 절화의 포장내 건식저장 기간별 수분함량과 품질 변화)

  • Lee, Jung-Soo;Rhee, JuHee;Kang, Yun-Im;Choi, Ji Weon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.1
    • /
    • pp.27-36
    • /
    • 2017
  • In order to determine the relationship between water content and flower qualities of oriental hybrid lily cv. 'Siberia' cut flower, flowers were subjected to dry and cold storage at $5^{\circ}C$ for 3, 6, and 12 days and subsequently exposed to ambient temperature ($26^{\circ}C$) in bottles with water for up to 16 days. Flowers stored at $22^{\circ}C$ in dry condition for 3 days were used as the control. Changes in fresh weight, moisture content, water balance, flowering stages, osmolality and vase life of cut flowers were observed. Flowers treated with cold and dry storage had higher moisture content compared to control sample. However, this trend was evident only for 3-day cold and dry stored sample during the whole storage period. The fresh weight of cut flowers increased gradually when the samples were transferred to ambient temperature in water bottles and then declined steadily before reaching the peak in between 6-8 days of vase life. However, the changes of fresh weight of control sample were substantially faster than samples pre-treated with cold and dry storage. This was also correlated with the water balance of cut flower as it reached the minus (-) value in 6-8 days of vase life at ambient temperature. Cut lily flowers showed high osmolality values corresponding with the duration of dry storage regardless of low or higher temperature. However, osmolality had no effect on vase life since flower stem absorbed water rapidly at the end of dry storage period. Our vase life results suggest that cold and dry storage of lily cut flowers for a certain period could ensure longer vase life at ambient temperature. It was observed that prolonging the storage period at cold and dry condition for more than a week significantly increased bud abortion, reduced longevity of flowers and reduced the vase life of cut flowers. On the other hand, the shorter cold and dry storage treatment delayed the bud opening and senescence of the flowers, thus, slowering the normal maturation and aging. Results indicated that dry and cold storage at $5^{\circ}C$ for 3 days was effective in maintaining and preserving overall quality and vase life at ambient condition of oriental hybrid lily cut flowers.

Dependence of CCFL Characteristics on Ambient Temperatures

  • Kim, Jeong-Eui;Lee, Soon-Seok;Lim, Sung-Kyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.646-648
    • /
    • 2003
  • The electrical and optical characteristics of the cold cathode fluorescent lamps (CCFL) were measured and investigated under the wide ambient temperatures ranging from $-30^{\circ}C$ up to $+100^{\circ}C$. The highest luminous efficiency of the CCFL of 55 lm/W was obtained at the ambient temperature of $50^{\circ}C$.

  • PDF

Storage Characteristics of Low Temperature Grain Warehouse using Ambient Cold Air in Winter

  • Ning, Xiao Feng;Li, He;Kang, Tae-Hwan;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.184-191
    • /
    • 2012
  • Purpose: This study was conducted to investigate the storage and quality characteristics of brown rice under the low temperature warehouse conditions using ambient cold air in the winter. Methods: This new technique maintains rough rice warehouse temperature below $15^{\circ}C$ without cooling operation until the end of May. Four hundred tons of rough rice were stored in the low temperature grain warehouse, and were aerated from the top to the bottom using ambient cold air in February. The quality of rough rice was evaluated from February through October. Results: The results were as followings. Moisture contents of rough rice in the low temperature storage had decreased less than the ordinary temperature storage. Cracked rate of brown rice in the ordinary temperature storage and low temperature storage increased by 4~10.8% and 1.6~7.2%, respectively. The germination rate of rough rice under the ordinary and the low temperature warehouse decreased by 15.0~25.0% and 1.7~8.0%, respectively. The acid value of brown rice under the ordinary and the low temperature warehouse increased by 3.67~6.72 KOH mg/100g and 3.08~4.08 KOH mg/100g, respectively. Conclusions: The result indicates that low temperature storage using ambient winter air showed better maintaining germination of rice, less change of physiological activities and cracked kernel, and better maintaining of rice quality, comparing the ordinary temperature storage.

Regional Differences in Onion Bulb Quality and Nutrient Content, and the Correlation Between Bulb Characteristics and Storage Loss

  • Lee, Jongtae;Ha, Injong;Kim, Heedae;Choi, Silim;Lee, Sangdae;Kang, jumsoon;Boyhan, George E.
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.807-817
    • /
    • 2016
  • Many onion growers and researchers assert that differences in soil type, agricultural practices, weather, and duration of prolonged onion cultivation in a particular field could affect onion bulb quality. This study evaluates the bulb quality of onions grown in different regions and determines the correlations between bulb characteristics and postharvest loss during cold and ambient storage. Soil and onion bulbs were collected from fields in six onion growing regions in Korea, during the growing season of 2011-2012. The fresh weight, dry matter content, and carbon (C), sulfur and magnesium contents of the onion bulbs were significantly affected by the location in which they were grown. Bulbs grown in Muan had the greatest number of scales, thinnest scale thickness, and the highest total soluble solids (TSS) and total flavonoids (TF). Bulbs originating from Jecheon had the lowest pyruvic acid (PA), total phenolics and TF. Storage loss of bulbs from the different regions was similar in refrigerated storage, but differed in ambient temperature storage. Bulb fresh weight was positively correlated with scale thickness (r = 0.617) and cold storage loss (CSL; r = 0.398). Dry matter content was positively correlated with C (r = 0.958) and TF (r = 0.256) contents, while it was negatively correlated with CSL (r = -0.424). CSL was primarily affected by the fresh weight, as well as the dry matter, C, and PA contents of the bulbs, while ambient storage loss was primarily influenced by the amount of TSS.

The Development of a PCM Cold Storage Refrigerator using Forced Convection Method (강제대류방식 PCM 축냉장고 개발)

  • Lee, Sang-Ryoul;Ryu, In-Keun;Kim, Jin-Hong;Jun, Young-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.517-522
    • /
    • 2005
  • A cold storage refrigerator using phase change material(PCM) has been developed and its performance test results are provided here. The inner temperature of the refrigerator is controlled with forced convection driven by a fan using a DC battery. At the first, to freeze all the PCM of the ambient temperature by a built-in refrigerating machine, it took about 8 and 10 hours respectively at the refrigerator and the freezer mode. Then, without external power supply, the inner temperature of the cold storage refrigerator has been maintained at $-18{\pm}1^{\circ}C$ during 14 hours at the freezer mode and maintained at $3{\pm}^{\circ}C$ during 34 hours at the refrigerator mode. Just after the end of its valid usage as a refrigerator or a freezer, it took about 6 hours to refreeze the PCM for its reuse. During the test, the ambient temperature was kept at $30^{\circ}C$.

  • PDF