• Title/Summary/Keyword: ambient MS

Search Result 83, Processing Time 0.033 seconds

PHOTOCATALYTIC SYNTHESIS OF L-PIPECOLINIC ACID FROM $N_{varepsilon}$-CARBAMYL-L-LYSINE BY AQUEOUS SUSPENSION OF PLATINIZED TITANIUM(IV) OXIDE

  • Ohtani, Bunsho;Aoki, Eishiro;Iwai, Kunihiro;Nishimoto, Sei-Ichi
    • Journal of Photoscience
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 1994
  • Photoirradiation at > 300 nm onto a suspension of platinized TiO$_2$ (TiO$_2$-Pt) particles in an aqueous solution. of N$_{\varepsilon}$-carbamyI-L-lysine (Lys(CONH)$_2$) induced the selective N-cyclization of Lys(CONH$_2$) into almost optically pure L-pipecolinic acid (PCA) under argon atmosphere at ambient temperature. Among various TiO$_2$-Pt catalysts, a P-25 (Degussa) powder platinized via impregnation from chloroplatinic acid followed by hydrogen reduction at 753 K exhibited the highest photocatalytic activity for Lys(CONH$_2$) consumption and L-PCA production. GC-MS analyses of L-PCA obtained photocatalytically from $^{15}$N$\alpha$-Lys(CONH$_2$) revealed the selective formation $^{15}$N-substituted L-PCA. This implies that the mechanism for L-PCA production contains selective cleavage of C$_{\varepsilon}$-N bond and intramolecular alkylation at $\alpha$-amino group. Effect of pH on the rate of this photocatalytic reaction was investigated in detail and compared with the pH-dependent charge distribution in Lys(CONH$_2$) molecule. It is clarified that protonation-deprotonation of $\alpha$-amino group gives marked influence on the rate and selectivity of the photocatalytic reaction. On the basis of these results, it is concluded that the selective production of optically pure L-PCA, especially in an acidic suspension of TiO$_2$-Pt, was attributed to the enhanced protonation of $\alpha$-amino group to prevent undesirable oxidation by photogenerated positive holes and blocking of $\varepsilon$-amino group to yield racemic Schiff base intermediate.

  • PDF

An Assessment of Genotoxicity on Organic Solvent Workers by $^{32}$P-postlabelling Method ($^{32}$P-postlabelling법을 이용한 유기용제 작업장 근로자의 유전독성 평가)

  • 홍대용;김장락;이장호;문중갑;이한우;김동일;박성학;정주화;이홍근
    • Environmental Analysis Health and Toxicology
    • /
    • v.9 no.1_2
    • /
    • pp.37-51
    • /
    • 1994
  • To evaluate the genotoxicities of workers exposed to glue and glue cleaning solution, ambient air monitoring of working place, animal study and human monitoring were carried out. By GC-MS analysis, air samples collected from shoesmaking plant were found to be toluene, xylene, cyclohexane, n-hexane, methyl ethyl ketone, trichloroethylene, butylacetate, isopropyl alcohol. Glue and glue cleaning solution from shoesmaking plant were applicated topically to the CD-1 mice. DNA was isolated from skin 24 hr following the application and analysed for DNA-adducts using the nuclease $P_1$version of $^{32}$P-postlabelling assay. RAL (Relative Adduct Labelling, adducts$10^8$ nucleotides) was significantly increased in a dose-dependent manner in the glue cleaning solution treated mice skin. Peripheral blood DNA-adducts of workers exposed to glue and glue cleaning solution were also analysed by the same method, but there were not significant differences in the peripheral blood DNA-adducts level between exposed and control workers. In addition, glue cleaning solution from shoes factory was evaluated for mutagenicity in the Salmonella plate incorporation assay using strains TA 100 and TA 1535 in the presence and absence of Arochlor 1254-induced rat liver S$_{9}$. There was evident mutagenicity for cleaning solution in TA 100 regardless of $S_9$, but TA 1535 showed positive only in the absence of $S_9$when predicted by Stead model of mutagenicity prediction (p=0.0000). The urine concentrates from workers and controls were also assayed for mutagenicity towards strain TA 100 of Salmonella typhimurium in the presence of $S_9$ using Kado's microsuspension assay, but their mutagenic activities were not found to be significant. These data suggest that shoesmaking workers are exposed to genotoxic compounds and need to be monitored by testing the mutagenicity of human urines. However, $^{32}$P-postlabelling application requires further validation for the routine monitoring of human exposure.osure.

  • PDF

Characteristics of Hazardous Air Pollutants in the Steel Industrial City, Pohang ( I ) - Polycyclic Aromatic Hydrocarbons (철강산업도시 포항지역 유해대기오염물질의 오염특성 ( I ) - 다환방향족탄화수소)

  • Baek, Kyung-Min;Seo, Young-Kyo;Cho, Byoung-Yoon;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.233-243
    • /
    • 2018
  • This study was carried out to characterize the ambient levels of PAH concentrations in Pohang city, where steel industry has been intensively developed. A large amount of PAH emissions from steel production and related industries in Pohang are concerned about the environmental health hazards of nearby residents. TSP samples were seasonally collected during 10 days at four sites in Pohang from April to December 2010. Each sample was collected for 24 hours using high-volume air sampler. All samples were extracted by $soxtec^{TM}$ before concentration of 1.0 mL. The concentrates were analyzed by GC/MS. The prevailing wind direction was southwest and west-southwest in Pohang during the measurement period. Variations of TSP concentrations appeared to be similar between four sites. The highest TSP concentration was found in fall, while the lowest in summer. The highest PAH concentration was found at an industrial site, while the lowest at a residential/commercial site. In the case of BaP, the average concentration at the industrial site was $0.63{\pm}0.66ng/m^3$, which was approximately 2 times of the residential/commercial site. The paired t-test (p<0.05) showed significant differences between industrial and residential area. Particulate PAH concentrations were higher in the winter and lower in the summer. The concentrations of BaP in winter were 2~10 times higher than those in the other three seasons. This study clearly demonstrated the impact of steel industry on the elevated levels of PAH in Pohang city.

Electrical Properties of ZnO-Bi2O3-Sb2O3 Ceramics (ZnO-Bi2O3-Sb2O3 세라믹스의 전기적 특성)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee;Kim, Jin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.738-748
    • /
    • 2008
  • In this study, it has been investigated on the changing behavior of electrical properties in $ZnO-Bi_2O_3-Sb_2O_3$ (Sb/Bi=2.0, 1.0 and 0.5) ceramics. The samples were prepared by conventional ceramic process, and then characterized by I-V, C-V curve plots, impedance and modulus spectroscopy (IS & MS) measurement. The electrical properties of ZBS systems were strongly dependent on Sb/Bi. In ZBS systems, the varistor characteristics were deteriorated noticeably with increasing Sb/Bi and the donor density and interface state density were increased with increasing Sb/Bi. On the other hand, we observed that the grain boundary reacted actively with the ambient oxygen according to Sb/Bi ratio. Especially the grain boundaries of Sb/Bi=0.5 systems were divided into two types, i.e. sensitive to oxygen and thus electrically active one and electrically inactive intergranular one with temperature. Besides, the increased pyrochlore and $\beta$-spinel phase with Sb/Bi ratio caused the distributional inhomogeneity in the grain boundary barrier height and the temperature instability. To the contrary, the grain boundary layer was relatively homogeneous and more stable to temperature change and kept the system highly nonlinear at high Bi-rich phase contents.

Application of Semi-continuous Ambient Aerosol Collection System for Elemental Analysis (대기입자의 원소성분 배출특성연구를 위한 반-연속식 입자채취시스템 적용)

  • Park, Seung-Shik;Ko, Jae-Min;Lee, Dong-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.39-51
    • /
    • 2012
  • Aerosol slurry samples were collected in 60-min interval using Korean Semi-continuous Elements in Aerosol Sampler (KSEAS) between May 19 and June 6, 2010 at an urban site of Gwangju. The $PM_{2.5}$ samples were collected with a flow rate of 16.7 L/min and particles are grown by condensation of water vapor in a condenser maintained at ${\sim}5^{\circ}C$ after saturation by direct injection of steam. The resulting droplets are collected in a liquid slurry with a airdroplet separator. Concentrations of 16 elements (Al, Fe, Mn, Ca, K, Cu, Zn, Pb, Cd, Cr, Ti, V, Ni, Co, As, Se) in the collected slurry samples were determined off-line by ICP-MS. KSEAS sample analysis encompassed the sampling periods for which 24-hr average elemental species concentrations were calculated for comparison with those derived from 24-hr integrated filter samples. Relationship between elemental species measured by two methods indicated high correlation coefficients (r), mostly greater than r of 0.80. However, we note that concentrations of Al, K, Ca, Mn, and Fe, which are often associated with crustal elemental particles, in the KSEAS samples, were substantially lower (1.4~11 times) than those found in the typical filter-based samples. This discrepancy is probably due to difficulties in transferring insoluble dust particles to the collection vials in the KSEAS. Temporal profiles of elemental concentrations indicate that some transient events in their concentrations are observed over the sampling periods. For the elemental species studied, atmospheric concentrations during the transient events increased by factors of 4 in Mn~80 in Zn, compared to their background levels. Principle component analyses were applied to the hourly KSEAS data sets to identify sources affecting the concentrations of the metal constituents observed. In this study, we conclude that hourly measurements for particle-bound elemental constituents were extremely useful for revealing the short-term variability in their concentrations and developing insights into their sources.

Equimolar Carbon Dioxide Absorption by Ether Functionalized Imidazolium Ionic Liquids

  • Sharma, Pankaj;Park, Sang-Do;Park, Ki-Tae;Jeong, Soon-Kwan;Nam, Sung-Chan;Baek, Il-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2325-2332
    • /
    • 2012
  • A series $[C_3Omim]$[X] of imidazolium cation-based ILs, with ether functional group on the alkyl side-chain have been synthesized and structure of the materials were confirmed by various techniques like $^1H$, $^{13}C$ NMR spectroscopy, MS-ESI, FTIR spectroscopy and EA. More specifically, the influence of changing the anion with same cation is carried out. The absorption capacity of $CO_2$ for ILs were evaluated at 30 and $50^{\circ}C$ at ambient pressure (0-1.6 bar). Ether functionalized ILs shows significantly high absorption capacity for $CO_2$. In general, the $CO_2$ absorption capacity of ILs increased with a rise in pressure and decreased when temperature was raised. The obtained results showed that absorption capacity reached about 0.9 mol $CO_2$ per mol of IL at $30^{\circ}C$. The most probable mechanism of interaction of $CO_2$ with ILs were investigated using FTIR spectroscopy, $^{13}C$ NMR spectroscopy and result shows that the absorption of $CO_2$ in ether functionalized ILs is a chemical process. The $CO_2$ absorption results and detailed study indicates the predominance of 1:1 mechanism, where the $CO_2$ reacts with one IL to form a carbamic acid. The $CO_2$ absorption capacity of ILs for different anions follows the trend: $BF_4$ < DCA < $PF_6$ < TfO < $Tf_2N$. Moreover, the as-synthesized ILs is selective, thermally stable, long life operational and can be recycled at a temperature of $70^{\circ}C$ or under vacuum and can be used repeatedly.

Autotrophic Growth of Dendranthema grandiflorum R. 'Bongwhang' Plantlets In Vitro as Affected by PPF, Air Exchange Rate and $\textrm{CO}_2$ Concentration (봉황국화의 자가영양배양시 광도, 환기횟수 및 $\textrm{CO}_2$농도가 기내생육에 미치는 영향)

  • 김영회;정병룡
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.56-66
    • /
    • 1999
  • Growth of Dendranthema grandiflorum R. ‘Bongwhang’plantlets, as affected by three levels of photosynthetic photon flux (PPF), 70, 150 and 220 $\mu$mol. $m^{-2}$ . $s^{-1}$ , three levels of C $O_{2}$ concentration, 400-500 (ambient), 1000 and 2000 $\mu$mol.mo $l^{-1}$ , and two levels of number of air exchanges per hour (NAEH), 0.1 $h^{-1}$ and 2.8 $h^{-l}$, was studied. Explants were obtained from photomixotrophically-micropropagated plantlets. Four explants were planted in each 3.7$\times$10$^{-4}$ $m^{3}$ polycarbonate box containing MS medium supplemented with 1.25 meq. $L^{-1}$ $H_{2}$P $O_{4}$$^{[-10]}$ and no added sugar. Explants were cultured under cool-white fluorescent lamps (16 h. $d^{-1}$ ), at 25$\pm$1$^{\circ}C$ temperature, and 70-80% relative humidity. In treatments of 2.8 $h^{-1}$ NAEH, a 10 mm round hole made on the vessel cap was sealed with a microporous filter For higher C $O_{2}$ concentrations in the culture room, C $O_{2}$ gas was provided from a tank of liquefied C $O_{2}$. Fresh and dry weights, height, length of the longest roots, number of leaves, and leaf area significantly increased with increasing PPF and especially, with increasing C $O_{2}$ concentration. Growth was enhanced with increased number of air exchanges per hour (2.8 $h^{-1}$ ). Overall, treatment of 220$\mu$mol. $m^{-2}$ . $s^{-1}$ PPF combined with 2000$\mu$mol.mo $l^{-1}$ C $O_{2}$ and 2.8 $h^{-1}$ NAEH gave the most vigorous growth of Dendranthema grandiflorum R. ‘Bongwhang’ plantlets in vitro.o.

  • PDF

Classification and identification of organic aerosols in the atmosphere over Seoul using two dimensional gas chromatography-time of flight mass spectrometry (GC×GC/TOF-MS) data (GC×GC/TOF-MS를 이용한 서울 대기 중 유기 에어로졸의 분류 및 동정)

  • Jeon, So Hyeon;Lim, Hyung Bae;Choi, Na Rae;Lee, Ji Yi;Ahn, Yun Kyong;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.153-169
    • /
    • 2018
  • To identify a variety of organic compounds in the ambient aerosols, the two-dimensional gas chromatography-time of flight mass spectrometry (GCxGC) system (2DGC) has been applied. While 2DGC provides more peaks, the amount of the generated data becomes huge. A two-step approach has been proposed to efficiently interpret the organic aerosol analysis data. The two-dimensional 2DGC data were divided into 6 chemical groups depending on their volatility and polarity. Using these classification standards, all the peaks were subject to both qualitative and quantitative analyses and then classified into 8 classes. The aerosol samples collected in Seoul in summer 2013 and winter 2014 were used as the test case. It was found that some chemical classes such as furanone showed seasonal variation in the high polarity-volatile organic compounds (HP-VOC) group. Also, for some chemical classes, qualitative and quantitative analyses showed different trends. Limitations of the proposed method are discussed.

A Statistical model to Predict soil Temperature by Combining the Yearly Oscillation Fourier Expansion and Meteorological Factors (연주기(年週期) Fourier 함수(函數)와 기상요소(氣象要素)에 의(依)한 지온예측(地溫豫測) 통계(統計) 모형(模型))

  • Jung, Yeong-Sang;Lee, Byun-Woo;Kim, Byung-Chang;Lee, Yang-Soo;Um, Ki-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.23 no.2
    • /
    • pp.87-93
    • /
    • 1990
  • A statistical model to predict soil temperature from the ambient meteorological factors including mean, maximum and minimum air temperatures, precipitation, wind speed and snow depth combined with Fourier time series expansion was developed with the data measured at the Suwon Meteorolical Service from 1979 to 1988. The stepwise elimination technique was used for statistical analysis. For the yearly oscillation model for soil temperature with 8 terms of Fourier expansion, the mean square error was decreased with soil depth showing 2.30 for the surface temperature, and 1.34-0.42 for 5 to 500-cm soil temperatures. The $r^2$ ranged from 0.913 to 0.988. The number of lag days of air temperature by remainder analysis was 0 day for the soil surface temperature, -1 day for 5 to 30-cm soil temperature, and -2 days for 50-cm soil temperature. The number of lag days for precipitaion, snow depth and wind speed was -1 day for the 0 to 10-cm soil temperatures, and -2 to -3 days for the 30 to 50-cm soil teperatures. For the statistical soil temperature prediction model combined with the yearly oscillation terms and meteorological factors as remainder terms considering the lag days obtained above, the mean square error was 1.64 for the soil surfac temperature, and ranged 1.34-0.42 for 5 to 500cm soil temperatures. The model test with 1978 data independent to model development resulted in good agreement with $r^2$ ranged 0.976 to 0.996. The magnitudes of coeffcicients implied that the soil depth where daily meteorological variables night affect soil temperature was 30 to 50 cm. In the models, solar radiation was not included as a independent variable ; however, in a seperated analysis on relationship between the difference(${\Delta}Tmxs$) of the maximum soil temperature and the maximum air temperature and solar radiation(Rs ; $J\;m^{-2}$) under a corn canopy showed linear relationship as $${\Delta}Tmxs=0.902+1.924{\times}10^{-3}$$ Rs for leaf area index lower than 2 $${\Delta}Tmxs=0.274+8.881{\times}10^{-4}$$ Rs for leaf area index higher than 2.

  • PDF

A comparative analysis of volatile organic compound levels in field samples between different gas chromatographic approaches (분석기법의 차이에 따른 현장시료의 VOC 분석결과 비교연구: 분석오차의 발생 양상과 원인)

  • Ahn, Ji-Won;Pandey, Sudhir Kumar;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.465-476
    • /
    • 2010
  • In this study, a number of volatile organic compounds (VOCs) including benzene, toluene, p-xylene, styrene, and methyl ethyl ketone were analyzed from samples collected in ambient air and under the field conditions. These samples were analyzed independently by two different set-ups for VOC analyses, i.e., between [1] gas chromatography/flame ionization detector with tube sampling - (F-T system) and [2] gas chromatography/mass spectrometer with bag sampling (M-B system). The analytical results derived by both systems showed fairly similar patterns in relative sense but with moderately large differences in absolute sense. The results of M-B system were high relative to F-T system with the F-T/M-B ratio below 1. If the relative biases of the two measurement techniques are derived in terms of percent difference (PD) in concentration values, the results were generally above 35% on average. A student t-test was applied to investigate the statistical significance of those differences between the systems. The results of both analytical systems were different at 95% confidence level for toluene, p-xylene, styrene, and methyl ethyl ketone (P < 0.043). However, F-T and M-B systems showed strong correlations for toluene and p-xylene. The observed bias is explained in large part by such factors as the differences in standard phases used for each system and the chemical loss inside the bag sampler.