• Title/Summary/Keyword: ambient MS

Search Result 83, Processing Time 0.025 seconds

An Investigation on the Spray Characteristics of DME Common Rail Fuel Injection System with Variation of Ambient Pressure (분위기 압력변화에 따른 DME 커먼레일 연료 분사 시스템의 분무 특성에 관한 연구)

  • Lee, Se-Jun;Oh, Se-Doo;Jeong, Soo-Jin;Lim, Ock-Taeck
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.90-97
    • /
    • 2012
  • It is investigated of the DME spray characteristics about varied ambient pressure and fuel injection pressure using the common rail fuel injection system when the nozzle holes diameter is varied. The common rail fuel injection system and fuel cooling system is used since DME has compressibility and vaporization in atmospheric temperature. The fuel injection quantity and spray characteristics were measured. The spray was analyzed of spray shape, penetration length, and spray angle at the six nozzle holes. The 2 types injector were used, the one was 0.166 mm diameter the other one was 0.250 mm diameter. The ambient pressure which is based on gage pressure was 0 MPa, 2.5 MPa, and 5 MPa. The fuel injection pressure was varied by 5 MPa from 35 MPa to 70 MPa. When using the converted injector, compared to using the common injector, the DME injection quantity was increased 127 % but it didn't have the same heat release. Both of the common and converted injector had symmetric spray shapes. In case of converted injector, there were asymmetrical spray shapes until 1.2 ms, but after 1.2 ms the spray shape was symmetrical. Compared with the common and converted injector, the converted injector had shorter penetration length and wider spray angle than the common injector.

LC-MS/MS-based Proteomic Analysis to Identify Protein Phosphorylation in Emiliania huxleyi

  • Duong, Van-An;Nam, Onyou;Jin, EonSeon;Seo, Jae-Min;Park, Jong-Moon;Lee, Hookeun
    • Mass Spectrometry Letters
    • /
    • v.12 no.4
    • /
    • pp.163-171
    • /
    • 2021
  • Emiliania huxleyi is a marine phytoplankton that plays a critical role in global carbon and sulfur cycling. The genome of E. huxleyi has been sequenced, and an in-depth proteomic profile of this organism has been reported. This study analyzed the phosphoproteome of E. huxleyi and identified its changes under calcium-limited conditions. A TiO2 microcolumn was used for phosphopeptide enrichment, followed by liquid chromatography-tandem mass spectrometry analysis. Overall, we identified 7,010 phosphorylated sites on 3,355 phosphopeptides associated with 2,929 phosphoproteins in E. huxleyi. Quantitative analysis revealed changes in the phosphoproteome in E. huxleyi when ambient conditions changed to calcium-limited conditions, notably the phosphorylation of some transporters was altered. This study provides an overview of protein phosphorylation in E. huxleyi and paves the way for further investigations of its biological functions.

Experimental Study on the Macroscopic Spray Characteristics of DME Fuel (DME 연료의 거시적 분무특성에 관한 실험적 연구)

  • Park, Jeong-Hwan;Park, Su-Han;Lee, Chang-Sik;Park, Sung-Wook
    • Journal of ILASS-Korea
    • /
    • v.15 no.3
    • /
    • pp.115-123
    • /
    • 2010
  • The purpose of this study is to compare and to investigate spray characteristics of dimethyl ether (DME) and diesel fuel in the various injection pressures, ambient pressures, and the energizing durations. For the analysis of the spray characteristics, the spray visualization system including the high speed camera and the spray image analyzer is installed. The spray characteristics such as the spray development process, spray tip penetraion and the spray cone angle are analyzed from the spray images. It was revealed that the spray characteristics of DME and diesel fuels are mainly affected by the injection conditions. However, in the region after the end of the injection, the spray tip penetration was affected by the fuel properties such as the fuel density, the surface tension, and the viscosity. DME fuel has generally a short tip penetration and a wide cone angle. In the elevating conditions of the ambient gas pressure, the spray cone angle of DME fuel converged to high value when comparing diesel fuel in advance. Also, the increasing rate of the spray tip penetration in DME fuel is significantly decreased from 0.7 ms of the energizing duration (diesel : 0.9 ms).

Fragmentation Behavior Studies of Chalcones Employing Direct Analysis in Real Time (DART)

  • Motiur Rahman, A.F.M.;Attwa, Mohamed W.;Ahmad, Pervez;Baseeruddin, Mohammad;Kadi, Adnan A.
    • Mass Spectrometry Letters
    • /
    • v.4 no.2
    • /
    • pp.30-33
    • /
    • 2013
  • Chalcones are naturally occurring, biologically active molecules generating interest from a wide range of research applications including synthetic methodology development, biological activity investigation and studying fragmentation patterns. In this article, a series of chalcones has been synthesized and their fragmentation behavior was studied using modern ambient ionization technique Direct Analysis in Real Time (DART). DART ion source connected with an ion trap mass spectrometer was used for the fragmentation of various substituted chalcones. The chalcones were introduced to the DART source using a glass capillary without sample preparation step. All the chalcones showed prominent molecular ion peaks $[M]^{{\cdot}+}$ corresponding to the structures. Multistage mass spectral data $MS^n$ ($MS^2$ and $MS^3$) were collected for all the chalcones studied. The chalcones with substitutions at 3, 4 or 5 positions gave product ion peaks with the loss of a phenyl radical ($Ph^{\cdot}$) by radical initiated ${\alpha}$-cleavage, while substitution at 2 position of chalcone in the A-ring gave a product ion peak with the loss of substituted styryl radical (PhCH = $CH^{\cdot}$). In case of the chalcones with the substituent at 4 positions in A and B rings gave both types of fragmentation patterns. In conclusion, chalcones can be easily characterized using modern DART interface in very short time and efficiently without any cumbersome sample pretreatment.

Toxic Trace and Earth Crustal Elements of Ambient PM2.5 Using CCT-ICP-MS in an Urban Area of Korea

  • Lee, Jin-Hong;Jeong, Jin-Hee;Lim, Joung-Myung
    • Environmental Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.3-8
    • /
    • 2013
  • Collision cell technology-inductively coupled plasma-mass spectrometry (CCT-ICP-MS) was used to measure the concentrations of approximately 19 elements associated with airborne PM2.5 samples that were collected from a roadside sampling station in Daejeon, Korea. Standard reference material (SRM 2783, air particulate on filter media) of the National Institute of Standards and Technology was used for the quality assurance of CCT-ICP-MS. The elemental concentrations were compared statistically with the certified (or recommended) values. The patterns of distribution were clearly distinguished between elements with their concentrations ranging over four orders of magnitude. If compared in terms of enrichment factors, it was found that toxic trace elements (e.g., Sb, Se, Cd, As, Zn, Pb, and Cu) of anthropogenic origin are much more enriched in PM2.5 samples of the study site. To the contrary, the results of the correlation analysis showed that PM2.5 concentrations can exhibit more enhanced correlations with the elements (e.g., Fe, K, Si, and Ti) arising from earth's crust. The findings of strong correlations between PM2.5 and the elements of crustal origin may be directly comparable with the dominant role of those species by constituting a major fraction of even PM2.5 as well as PM10 at the roadside area.

Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea ( I ) - Evaluation of Sampling and Analytical Methodology (국내 대기 중 독성 휘발성 유기화합물의 오염 특성(I) - 측정 방법론 평가 -)

  • 백성옥;김미현;김수현;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.95-107
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the first part of the study, the performance of sampling and analytical methods was evaluated for the measurement of selected VOCs and carbonyl compounds in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis, while carbonyls by the DNPH-silica cartridge sampling with HPLC analysis. The methodology was investigated with a wide range of performance criteria such as repeatability, linearity. lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal standards. In addition, the sampling and analytical methods established in this study were applied to real field samples duplicately collected in various ambient environments. Precisions for the duplicate samples appeared to be comparable with the performance criteria recommended by USEPA TO-17. The overall precision of the sampling and analytical methods was estimated to be within 20 ∼ 30% for major aromatic VOCs such as BTEX, whereas the precision for major carbonyl compounds such as formaldehyde and acetaldehyde was within 10 ∼ 20% for field samples. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

Comparison of Sampling and Analysis Methods for Volatile Organic Compounds in Ambient Air (대기중 휘발성 유기화합물의 채취 및 분석 방법 비교)

  • 나광삼;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.507-518
    • /
    • 1998
  • A field comparison study was carried out to quantify differences among various sampling and analytical methods for volatile organic compounds (VOCs) at a site in Vlsan in June 1997. Air sampling containers (SUMMA canisters) were used by the Korea Institute of Science and Technology (KIST) and adsorption tubes (carbotrap) were used by Yeungnam University (YN Univ.) for sampling ambient air. Duplicate samples obtained by KIST were analyzed by KIST with a GC-MS system for aromatics and halogenated hydrocarbons and by Atm AA with a GC -FID system for C2∼C9 hydrocarbons, respectively. The adsorption tube samples were analyzed by YN Univ. with a GC-FID system for aromatics. VOC levels for the duplicate canister sampls analyzed by KIST and Atm AA were in good agreement. Concentrations of aromatics by the adsroption tube method were generally higher than those by the canister sampling method by factor of 1.5 to 2.0. Differences between the two sampling methods were discussed.

  • PDF

Application of Adsorption Sampling and Thermal Desorption with GC/MS Analysis for the Measurement of Low-Molecular Weight PAHs in Ambient Air (환경대기 중 저분자 PAHs 측정을 위한 흡착-열탈착-GC/MS 방법의 적용)

  • Seo, Seok-Jun;Seo, Young-Kyo;Hwang, Yoon-Jung;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.362-377
    • /
    • 2014
  • Polycyclic aromatic hydrocarbons (PAHs) have been of particular concern since they are present both in the vapor and particulate phases in ambient air. In this study, a simple method was applied to determine the vapor phase PAHs, and the performance of the new method was evaluated with a conventional method. The simple method was based on adsorption sampling and thermal desorption with GC/MS analysis, which is generally applied to the determination of volatile organic compounds (VOCs) in the air. A combination of Carbotrap (300 mg) and Carbotrap-C (100 mg) sorbents was used as the adsorbent. Target compounds included two rings PAHs such as naphthalene, acenaphthylene, and acenaphthene. Among them, naphthalene was listed as one of the main HAPs together with a number of VOCs in petroleum refining industries in the USA. For comparison purposes, a method based on adsorption sampling and solvent extraction with GC/MS analysis was adopted, which is in principle same as the NIOSH 5515 method. The performance of the adsorption sampling and thermal desorption method was evaluated with respect to repeatabilities, detection limits, linearities, and storage stabilities for target compounds. The analytical repeatabilities of standard samples are all within 20%. Lower detection limits was estimated to be less than 0.1 ppbv. In the results from comparison studies between two methods for real air samples. Although the correlation coefficients were more than 0.9, a systematic difference between the two groups was revealed by the paired t-test (${\alpha}$=0.05). Concentrations of two-rings PAHs determined by adsorption and thermal desorption method consistently higher than those by solvent extraction method. The difference was caused by not only the poor sampling efficiencies of XAD-2 for target PAHs and but also sample losses during the solvent extraction and concentration procedure. This implies that the levels of lower molecular PAHs tend to be underestimated when determined by a conventional PAH method utilizing XAD-2 (and/or PUF) sampling and solvent extraction method. The adsorption sampling and thermal desorption with GC analysis is very simple, rapid, and reliable for lower-molecular weight PAHs. In addition, the method can be used for the measurement of VOCs in the air simultaneously. Therefore, we recommend that the determination of naphthalene, the most volatile PAH, will be better when it is measured by a VOC method instead of a conventional PAH method from a viewpoint of accuracy.

QA/QC for Analysis of the Ambient VOC by Using Canister and GC/MS (Canister와 GC/MS를 이용한 대기 중 VOC 분석을 위한 QA/QC)

  • Jeon, Jun-Min;Heo, Dang;Bang, Hye-Jin;Choi, Won-Wook;Kim, Dong-Sool
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.85-86
    • /
    • 2000
  • 일반 대기환경중 미량으로 존재하는 휘발성유기화합물 (VOC)은 환경학적 측면에서 다양한 문제점을 야기한다. 즉, 인체 독성 및 발암성 물질, 오존의 전구물질, 성층권의 오존층 파괴 및 지구온난화 물질로서 영향을 주며, 한편, 대기환경 중 장기 체류하기도 한다. 최근 이들 화합물의 농도는 차량 증가 등 여러 요인들에 의해 지속적인 증가추세에 있다. 따라서 VOC로 인한 대기오염의 악화에 따라 체계적인 관리가 요구되고 있으며, 이와 더불어 VOC에 대한 정확한 측정 및 분석 능력에 입각한 신뢰성 있는 자료의 확보가 가장 절실하게 요구되고 있다. (중략)

  • PDF

Determination of Phthalates Compounds in the Ambient Atmosphere (I) - Evaluation of a Measurement Method and its Application to a Field Study - (환경대기 중 프탈레이트 화합물의 농도 측정 (I) - 측정방법 평가와 현장 적용 -)

  • Hwang, Yoon-Jung;Park, Young-Hwa;Seo, Young-Kyo;Seo, Gwang-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.443-454
    • /
    • 2010
  • Phthalate compounds are widely used as plasticizers in polyvinyl chlororide (PVC) resins and other industrial consumer products, and some of them are known to be endocrine disruptors. In Korea, a number of studies have been carried out for the measurement of phthalates in consumer products and drinking water. However, no data are available for those compounds in the ambient air where the general public are routinely exposed. In this study, we evaluated sampling and analytical methods for the determination of phthalates in the ambient atmosphere. A wide range of phthalates compounds were included in the target analytes, which are dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP), and di-n-octyl phthalate (DOP). Most of samples were collected using a high volume sampler with a PUF/XAD-2 column/quartz fiber filter and then analyzed by GC/MS. Some of samples were simultaneously collected on XAD-2 using a low-volume sampler, together with high-volume samples. The analytical method applied in this study showed good repeatability and linearity. Quantitative detection limits were estimated from 0.60 to 17.84 ng/$m^3$ in air, depending on individual compounds. The field measurements were carried out at 3 sites located in Sihwa- Banwall industrial areas and a suburban area from January 2007 to November 2007. From the field experiments, DEHP, DMP and DBP appeared to be the most abundant compounds in the ambient air. It was also found that DMP, DEP and DBP were mainly distributed in the vapor phase, while BBP, DEHP and DOP were predominantly associated with the particulate phase. The concentrations of DEHP and DMP in the industrial areas ranged from 45.7 to 1,012.7 ng/$m^3$ and from 7.7 to 375.1 ng/$m^3$, respectively. Overall, the high-volume sampling method was demonstrated to be superior to the low-volume method for the determination of phthalates in the ambient atmosphere.