• 제목/요약/키워드: allowable vibration velocity

검색결과 47건 처리시간 0.025초

진동 규제기준에 따른 인체의 허용 한계거리 예측 (The Prediction of Allowable Limit Distance about Human Body by Vibration Regulation)

  • 송정언;홍웅기;김승곤
    • 환경영향평가
    • /
    • 제21권2호
    • /
    • pp.289-296
    • /
    • 2012
  • The shock vibration such as machine vibration, blasting vibration etc. has effect on nearby structure as well as human body. The purpose of this study is to predict allowable limit distance of vibration about human body. First of all, vibration velocity such as PPV, PVS was measured by shock vibration experiment, and vibration level was calculated by conversion formula of vibration velocity. And then, allowable limit distance was analyzed by converted vibration level. The results are as follows : Firstly, the correlation coefficient of converted vibration level was over R=0.94, and vibration level caused by PVS was usually represented to high curve line. Secondly, the cross point of vibration level between ground and concrete condition was represented to 66.68dB(V), and allowable limit distance was represented to difference over three times when vibration regulation was raised from 65dB(V) to 80dB(V).

고압급수가열기 배수계통 배관계 고진동 해소방안 연구 (Vibration Reducing Method for High Pressure Feedwater Heater Drain Piping System)

  • 이욱륜;이준신;김상복;홍순법;신용우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1290-1295
    • /
    • 2006
  • The 120 meters high pressure feedwater heater drain piping in nuclear power plant had been suffered by excessive vibration from the beginning of power generation. As time goes by, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of high pressure feedwater heater drain piping and the countermeasure for abnormal vibration were investigated. Among the several vibration reduction methods, the piping layout changed by making the smooth pipeline was applied to the high Pressure feedwater heater drain piping in nuclear Power plant. Applying the countermeasure, the vibration level was found to reduce over 54 percents and was satisfied under the allowable velocity at the full-power operation condition.

  • PDF

인천국제공항 공항토목시설공사 구조물주변 다짐시공 사례 연구 (Case Study for Compaction in the Vicinity of Structures in Inchon International Airport Civil Construction)

  • 최인걸;신종순;김동수;성낙일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.455-462
    • /
    • 1999
  • In this case, we have selected a representative location in the vicinity of large underground structures where they cross a runway and taxiway: measured the effects of the dynamic hammer compaction by distance: analyzed the measured results over a period of time and for many frequencies: and determined the maximum anticipated particle velocity (PV) of vibration, caused by the dynamic hammer, verses distance. In addition, while compacting the hydrofill, we reviewed the impact of subsurface particle velocities, caused by hammer compaction methods, upon newly constructed reinforced concrete underground structures. We have implemented the appropriate technical standards after reviewing domestic and international technical standards concerning allowable vibration velocity appropriate In the many types of underground structures at Inchon International Airport.

  • PDF

계단식 발파에 있어서 자유면 전.후방의 지반진동에 관한 연구 (A Study on the Ground Vibration of the Front and the Back Direction of the Free Face in the Bench Blasting)

  • 기경철;김일중
    • 화약ㆍ발파
    • /
    • 제20권2호
    • /
    • pp.21-31
    • /
    • 2002
  • We did bench blasting upon the natural rock which it's uniaxial compressive strength was about $1,420~1,476kgf/\textrm{cm}^2$. This is the results we inferred after measuring, analyzing the ground vibration velocity of the front and back direction from the free face of the bench blasting. We have to induce the square and cube root scaled equation and the general equation to guarantee confidence upon the data when analyzing the measurement data of the test blasting. The variable distance is in reverse proportion to the permitted ground vibration velocity. The shorter is the exploding point to a protection structure, the bigger is the reflection that the direction of the free face experts the ground vibration velocity, The ground vibration velocity front of the free face tends become reduced about 38~46% compare with back of the free face in the range that the permitted ground vibration velocity is 2.0~5.0mm/sec. In case of 2.0mm/sec, when a protection structure is within about 95m, the max. allowable charge weight per delay on positing front of the free face can be more used about 2.61 times than that on positing back of the free face, in case of 3.0mm/sec within about 78m more about 2.38 times, in case of 5.0mm/sec within 60m more about 2.10 times. In case of 2.0~5.0mm/sec when a protection structure is within about 200m front from the free face, the max. allowable charge weight per delay can become about 1.52 times than the case on back to the free face.

원전 정지냉각계통 배관 진동안전성 평가연구 (A Safety Evaluation Study by Vibration Analysis for Shutdown Cooling Piping System)

  • 이욱륜;이준신;손석만;김만희;송승용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.41-45
    • /
    • 2007
  • Palo Verde Unit 1 nuclear power station which is located in Arizona, USA had been operating at reduced power levels around 25% since December 25, 2005 due to vibration in one of its shutdown cooling lines. During an outage from March 18, 2006 to July 7, 2006 the necessary work and modifications to remedy the situation were performed. It cost approximately $46million to buy electricity to replace that lost as a result of this event. Therefore in this study, the vibration of shutdown cooling lines in the same nuclear power plant in Korea as Palo Verde Unit 1 should be measured by the operating condition of power plant. And it was evaluated using the expression for allowable velocity in ASME OM-S/G-2003. From the result of this study it is evaluated whether it is safe or not. If not the countermeasure should be considered in this study.

  • PDF

발파진동이 인접한 터널의 콘크리트 라이닝과 록볼트의 안정성에 미치는 영향평가 (Stability Assessment of Concrete Lining and Rock Bolts of the Adjacent Tunnel by Blast-Induced Vibration)

  • 전상수;김두섭;장양원
    • 한국지반공학회논문집
    • /
    • 제23권10호
    • /
    • pp.33-45
    • /
    • 2007
  • 본 연구에서는 발파 시 발생되는 지반진동이 인접한 터널 지보재의 안정성에 미치는 영향을 분석하고, 발파진동에 의한 터널의 역학적 안정성을 허용진동속도를 기준으로 검토하였다. 기존에 제시된 미광무국과 서울지하철에서 제시한 이론식, 그리고 수치해석 프로그램을 사용하여 허용진동속도를 초과하지 않는 발파이격거리를 산정하였고, 발파시 콘크리트 라이닝과 록볼트의 거동을 평가하였다. 콘크리트 라이닝의 구조적 안정성에 미치는 발파진동영향은 미미한 것으로 나타났으나, 록볼트에 미치는 영향은 상대적으로 크다는 것을 알 수 있었다.

산업시설 근접발파 시 발파진동 영향 분석 및 평가 (Analysis and Evaluation of the Effect of Blast-induced Vibration Adjacent to Industrial Facilities)

  • 곽창원;박인준;김영준
    • 대한토목학회논문집
    • /
    • 제43권4호
    • /
    • pp.459-468
    • /
    • 2023
  • 발전소와 같은 산업시설은 국가 기간산업으로서 재해 발생 시 막대한 물적, 인적 피해가 발생하며 사회경제적 파급효과가 지대하다. 본 연구에서는 상업운전 중인 ○○발전소 부지 하부로 철도터널이 발파굴착될 때 발파진동의 특성과 영향을 평가하였다. 이를 위하여 진동 예민 구조물과 근접하여 발파한 기존 사례를 검토하고 발전소 근접 발파 시 합리적인 발파진동 허용 기준을 결정하였다. 발전소 내 주요 시설물들에 대한 발파진동 영향은 3차원 유한요소해석법에 의한 동적수치해석을 이용하여 발파하중 재하 시의 입자진동속도를 분석하고, 탁월주파수 산정을 통한 공진검토를 수행하였다. 해석결과 발파원과 가장 인접한 펌프기초에서 진동속도가 허용기준치에 근접하여 일부 발파패턴을 수정 후 계측하여 허용치 이내임을 확인함으로서 산업시설 근접발파 시 안정성을 확보할 수 있는 진동영향평가의 합리적인 의사결정과정을 확립하였다.

구조물에 대한 국외 발파진동 허용 규제기준 분석 (Review of National Standards for Allowable Limit of Blast Vibration on Structures)

  • 류창하
    • 화약ㆍ발파
    • /
    • 제23권3호
    • /
    • pp.1-10
    • /
    • 2005
  • 구조물의 발파진동에 대한 허용 수준 설정은 구조물의 반응 특성이 발파 진동의 특성과 전파 매질인 지반의 특성, 대상 구조물의 특성, 구조물의 기초 특성 등 여러 인파에 따라 달리 나타나므로 표준화된 기준을 적용하기는 쉽지 않은 일이다. 국외의 경우 영국, 독일, 스위스, 스웨덴과 같이 국가별로 허용수준에 대한 표준을 마련한 나라들도 있으며 아직 별도로 기준을 마련하지 않은 국가들도 많다. 우리나라는 통상 적용되고 있는 기준이 있으나 아직 국가 표준화는 되어 있지 않은 상황이며 민원 해결의 근거를 위한 합리적인 기준 마련의 필요성이 대두되고 있는 실정이다. 본 논문에서는 국가적으로 기준을 갖고 있는 미국, 영국, 독일, 스위스, 스웨덴 등의 사례와 개정 작업을 하고 있는 호주 및 브라질의 사례 분석을 통하여 다양한 형태의 기준들에 대한 특징을 파악하고 현행 사용되고 있는 국내 기준의 문제점을 고찰하였다.

도로 하부 통과 배관의 주행 하중 속도에 따른 진동 특성 (Dynamic Characteristics of Buried Pipeline under Vibration Velocity of Vehicle Loads)

  • 원종화;선진선;유한규;김문겸
    • 한국가스학회지
    • /
    • 제12권1호
    • /
    • pp.13-18
    • /
    • 2008
  • 지진 및 외부 진동에 의하여 구조물에 발생하게 되는 진동량은 진동 속도와 피해규모가 비례하는 관계에 있음을 고려하여 일반적으로 진동속도로 나타내어진다. 본 연구에서는 진동 속도 기반의 구조물 진동기준을 검토하고, 이를 고려하여 도로 하부 매설 가스 강관의 안정성 평가를 수행하였다. 가스공사 주사용 배관인 762 mm API 5L Gr. X65 강관을 해석 대상 배관으로 선정하였으며 도로설계기준에 의하여 지반 매설 조건 및 DB-24 하중을 다양한 속도에 대한 시간 함수로 고려하여 재하하였다. 진동속도는 차량 진행 속도 80 km/h까지 증가하다가 이후 감소하는 경향을 보였으며, 차량 진행 속도 80 km/h에서 0.034 cm/s의 진동 속도를 보임으로서 진동 기준 대비 매우 작은 값임을 확인하였다. 또한 감쇄법칙을 적용하여 진행파의 속도를 분석한 결과, 차량 진행 속도 80 km/h에서 가장 작은 속도를 나타내었다.

  • PDF

터널 발파로 인한 아파트 인근지역에서의 지반진동 전파특성 및 영향 평가 연구 (Environmental Effects and Characteristics of Ground Vibration Caused by Tunnel Blasting in the Vicinity of an Apartment)

  • 최병희;류창하;백승규
    • 화약ㆍ발파
    • /
    • 제22권1호
    • /
    • pp.57-65
    • /
    • 2004
  • 화약발파를 이용한 터널굴착은 지반진동 및 소음과 같은 발파공해적 요소가 수반됨으로써 주위 환경조건에 따라 여러 가지 형태의 피해를 유발할 수 있으며 시공 중에 종종 발생하는 민원의 주요 원인이 되고 있다. 본 연구는 터널 건설과정에서 노선이 통과하는 직상부 지역에 위치한 민가들과 인근의 아파트를 대상으로 발파로 인한 지반진동의 영향여부를 검토함으로써 사전에 발파작업으로부터의 안전성을 확보할 수 있는 근거를 마련코자 실시되었다. 먼저, 대상지역에 위치한 건물들에 대한 발파진동 허용수준은 보수적인 관점에서 0.5cm/sec를 관리수준으로 설정하였고, 터널 굴착과정에서 발생하는 발파진동 발생특성을 실측하기 위하여 총 6회의 굴진 발파에 대하여 총 70개소 이상의 측점에서 현장계측을 실시하였다. 발파진동 영향평가에서는 현장계측으로부터 획득한 자료들을 처리하여 발파로 발생하는 최대진동수준을 예측하기 위한 전파식들을 지상과 지하의 계측장소별로 유도하였다. 지반진동의 영향여부를 결정하기 위한 진동 예측식은 엄격한 기준을 적용하여 전체자료의 95%를 포함하는 식을 채택하였고, 지표 및 지하터널에 대해 각기 별도의 식을 사용할 것을 제안하였다.