Search Result 20, Processing Time 0.02 seconds

A Study on Tunnel Excavation by Controlled Blast Vibration at Particular Environment Conditions (발파진동 제어에 의한 특수구간 터널굴착에 관한 연구)

  • Choi, Hyung-Bin;Lim, Han-Uk
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.257-267
    • /
    • 2000
  • It was difficult to apply conventional excavation methods in some sections from Seoul to Pusan high speed rail road construction of 1 lot 2, due to highway concrete road, gas pipe, water pipe and nearby factories with automatic control system machine. To excavate safely and efficiently in these sections new blast patterns were employed within allowable blast vibration level, by test blast and controlled vibration by sequential blast. Behaviors of the rock mass including convergence and displacement around tunnel were measured with construction works and the crack width in concrete wall was also monitored for controlling allowable limits. The results can be summarized as follow : 1. The allowable blast vibration level in structure site is less 1.0cm/sec for highway concrete, 0.5 cm/sec for gas pipe, water pipe and building housing and 0.3 cm/sec for automatic control system machine. 2. The convergence displacement, single rod extensometer and multi rod extensometer around tunnel and cracks in concrete wall were measured, it was confirmed that the measured values were converged within allowable level. 3. The empirical formular of ground vibrations with 90% confidence lines for PD-3 was given as follow. $$V_{90%}=45.549({\frac{D}{\sqrt{W}}})^{-1.353}$$

  • PDF

A Review of Standards for Allowable Limit of Blast Vibration According to the Safety Facilities and Improvement of Problems (보안물건의 종류에 따른 발파진동 허용기준 적용 사례 및 문제점 개선 연구)

  • Kim, Nam-Soo;Lee, Jong-Woo;Cho, Kyoung-Bin
    • Explosives and Blasting
    • /
    • v.31 no.2
    • /
    • pp.50-58
    • /
    • 2013
  • Since various types of safety facilities have been located around blasting construction site, each of the institutions with regard to blast works has prepared limit criterion of blast vibration, respectively. But these criterions applied for limiting vibration are causing harmful effect including construction cost increasement and construction time extension due to exceedable high level application. In this study, more reasonable limit of blast vibration was suggested after reviewing criterions based on existing design and construction cases and analyzing of problems of applied criterions.

Review of National Standards for Allowable Limit of Blast Vibration on Structures (구조물에 대한 국외 발파진동 허용 규제기준 분석)

  • Ryu Chang-Ha
    • Explosives and Blasting
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2005
  • Blast-induced ground vibration nay cause an environmental impact such as neighbour's complaints or damage on adjacent structures and facilities. Complaints associated with blasting have often become a target of public grievances. One of the difficulties to solve the problem is that we do not have a national standard for the acceptance level of blast-induced ground vibration. A peak particle velocity criterion, which was suggested for urbane underground construction, has often been widely used. Efforts have been made to establish more rational criteria. It seems that differing cultures have often differing thresholds of the toleration of vibration, and that technical data or rational grounds for establishing the limits are hardly provided. In this paper, national standards for allowable limit of blast vibration were presented and discussed.

On the Determination of Safe Charge Weigth from the Several Predictive Equations of Blast Vibration (발파진동 예측식을 이용한 안전장약량 산정문제에 관하여)

  • 김일중;김영석
    • Tunnel and Underground Space
    • /
    • v.5 no.2
    • /
    • pp.89-94
    • /
    • 1995
  • Regression analysis and a comparative study were carried out for 52 blast vibration data which were monitored by changing the monitoring distance and charge per delay. The results are as follows: 1) The square and cube root scalings and general equation which have a confidence level at the point of 90% and 99% are V90=33300(SD)-2.026 , V90=23600(SD)-1.993, V90=26300W0.755 R-2.007 and V99=48400(SD)-2.026, V99=34000(SD)-1.993 , V99=38100W0.755R-2.007, respectively. 2) There is need to decide the allowable max. charge weight per delay considering the cross points comparatively of the nomogram constructed using several predictived equations. 3) It is necessary to derive the predictive equation on the basis of blast vibration level monitored in field and to decide safe vibration level and the confidence level.

  • PDF

On the study of the measurement of blasting Vibration and Sound influenced to housing structure at Wire-Tunnelling (부산 통신구굴진 발파작업으로 인한 지상주택 구조물에 미치는 진동폭음영향계측조사보고)

  • Huh Ginn
    • Explosives and Blasting
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1990
  • The Caustious blasting have often increased Complaints of ground Vibration and Sound when the Wire-Tunnel Constructed in Pusan. In order to prevent the influence to housing structure, it was necessary to predict blasting-Induced Vibration and Sound. The Suveyer determined the Burden and spacing of Drill holes, minimum delay charges within a allowable Vibration and Sound Level. Tunnel drilling and Ignition patterns are made as follows; No. 1 Tunel (Stable rock, hard rock) No.2 Tunnel (Instable plastic rock; wethered rock) and other Tunnels (Instable rock). The result of 1st testing blasting of No. 1 Tunnel was recorded Under allowable Vibration Level but sound was over 75 Db of allowable value. So Tunnel drilling pattern was amended with 52 Non-charg holes to reduce the blast-sound. The other pattern had no need to amend.

  • PDF

Blast Design of Hilly Rock Excavation Adjacent to Structures and Facilities (구조물 및 시설물 인접 구릉지의 암반굴착 발파설계)

  • 류창하;선우춘;신희순;정소걸;최병희
    • Tunnel and Underground Space
    • /
    • v.4 no.1
    • /
    • pp.38-46
    • /
    • 1994
  • This paper concerns the design of blasts adjacent to structures and facilities. In order to investigate the site characteristics, measurements of in-situ wave propagation and laboratory tests of rock cores taken from the boreholes were carried out. Effects of rock media and delay intervals on ground vibration levels were identified from over sixty measurements of three times of test blasts. For practical use in the field, an empirical propagation equation was derived so as to reflect the characteristics of rock media and delay effects. Safe limits of vibration level for structures were conservatively established based on various suggested criteria. Safe limits for facilities were adopted so that vibration levels induced by blasting should not exceed the allowable limits specified in the manufacturer's installation condition. Suggested were blast pattern and operation to enhance the rock fracturing and to reduce the ground vibration levels under the restricted conditions.

  • PDF

Influence of Near Field Blasting Vibration to Earth Retaining Wall (근거리 발파진동이 흙막이 구조물에 미치는 영향)

  • Whang, Hyun-Ju;Lee, Sang-Pil;Yang, Hyung-Sik
    • Tunnel and Underground Space
    • /
    • v.18 no.2
    • /
    • pp.118-124
    • /
    • 2008
  • Allowable level of blasting vibration for earth retaining wall was examined in this study. Blasting vibration was measured at near field blasting to evaluate the influence of the blasting work to earth retaining wall and rear ground. Although small scale blasting with $0.5{\sim}2.0kg$ explosives per round merely influenced to the structure and ground, but it was suggested to blast at the distance of twice the least burden considering the block movement.

ON THE DEVELOPMENT OF EXPLOSION TECHNOLOGY IN SEOUL METRO SUBWAY CONSTRUSTION (서울 지하철 건설의 발파기술 발전)

  • 許眞
    • Explosives and Blasting
    • /
    • v.18 no.1
    • /
    • pp.59-70
    • /
    • 2000
  • The blasting work to construct a subway in seoul, korea have often cased increased neighbor's complaints because of ground vibration. In order to prevent the demage to the stucture it was necessary to predict the level of blasting induced vibration and to determine the maximum charge weigh per delay with an allowable vibration level. The effect of blasting pattem, rock strength and different explosive on the blast-induced ground vibration was studied to determine the maximum charage weight per delay within a given vibration level. The blasting vibration equation from over 100 test data was obtained, V= K(D/W(equation omitted), where the values for n and K are estimated to be 1.7 to 1.5 and 48 to 138 respectively.

  • PDF

Environmental Effects and Characteristics of Ground Vibration Caused by Tunnel Blasting in the Vicinity of an Apartment (터널 발파로 인한 아파트 인근지역에서의 지반진동 전파특성 및 영향 평가 연구)

  • 최병희;류창하;백승규
    • Explosives and Blasting
    • /
    • v.22 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Explosive blasting in tunnel excavation produces ground vibration and air blast as its side effects, which may cause complaints from nearby residents. This study was intended to investigate the propagation characteristics of ground vibration induced by tunnel blasting and to evaluate its effects on the residential structures near the site. We have conducted field measurements for 6 blasts and acquired vibration data from 70 measuring points, some of which on positioned inside the tunnel for comparative reason. Various documentation was reviewed to determine an allowable level of peak particle velocity for the residential structures in the area and the allowable limit was set to 0.5 cm/sec. Propagation equations for peak particle velocities were derived from regression analyses using the data acquired at both the surface and the underground tunnel. Finally we proposed appropriate predictive equations for the two areas and a safe blasting criterion.

Some factors affecting level of blasting-induced vibration in urban area (도심지 발파에서 발파진동치의 크기에 영향을 미치는 제요소)

  • Huh, Ginn;Lim, Han uk
    • Journal of the Korean Professional Engineers Association
    • /
    • v.23 no.2
    • /
    • pp.81-93
    • /
    • 1990
  • The blasting to construct subways in Seoul, Korea. have often increased complaints of ground vibration. In order to prevent the damage to structures, it was necessary to predict the level of blasting induced vibration and to determine the maximum charge weight per delay within a allowable vibration level. A total of 109 blasts were recorded at ten sites. Blast-to-structure distances ranged from 8 to 84.2 meter, where charge weight varied from 0,1125 to 7.85 kg per delay. The data from blast were studied to determine the effect of explosives type on the vibration constants(k). Vibration constants were also analyzed in terms of compressive strength of rock and blasting patterns.

  • PDF