• Title/Summary/Keyword: all-digital

Search Result 3,884, Processing Time 0.034 seconds

How Digital Camera Has Changed Photographers? A Phenomenological Approach of Digital Labor (디지털 사진 이후 사진가들의 변화 현상학적 접근을 중심으로)

  • Cho, In Won
    • Korean journal of communication and information
    • /
    • v.84
    • /
    • pp.124-151
    • /
    • 2017
  • This study examines photographers who experienced steep changes from film to digital photography working and photography culture after using digital camera through a phenomenological approach. Digital technologies have brought many transition. Most of all digital camera popularize photography among people who had no knowledge and experience about camera. On the contrary digital photography made many professional photographers difficulties. After being digital photography, most film companies and film developing and printing studios have diminished. In addition many professional photographers have to cover increasing working time by decreasing photography price. For this research researcher interviewed 12 professional photographers who is working as a digital photographer. After collecting data, researcher analyse data by phenomenological approach. This study is looking for a meaning of photographers' labor after digital photography times.

  • PDF

DEVELOPMENT OF A STORAGE SYSTEM FOR THE TREATMENT DATA AND IMAGE DATA IN DENTISTRY USING THE OPTICAL LASER CARD (광 카드를 이용한 치과 진료자료 및 영상자료 저장 system 개발)

  • Shin, Yong-Pil;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.110-140
    • /
    • 1998
  • One of the problems facing in all modern dental hospitals is the much efforts, manpower and space are needed to effectively sort and stack patients' charts of the various dental departments. In addition, the storage and prompt arrangement of x-ray films is also a problem. Therefore, if dental charts as well as films could be computerized, it would be easier to store and keep them; by data basing, many space, manpower and cost would be saved: data could also be effectively managed for the purpose of academic researches. This would be an epoch -making event in the development of dental hospital management. The purpose of this study is to develop a dental information processing program, that will be used to store dental treatment records and digital image data using a new record media, the optical card. The patients' charts from the dental hospital were selected. The treatment records of the chart were put into the treatment data -recording area of the program, and the digital images of various dental x-ray films were made with a scanner. These data were stored in the optical card and analyzed to get the following results: 1. In this program it is possible to put treatment records and image data into and out from the optical card, and it is impossible to correct and delete all data recorded on the optical card. 2. All data in the optical card system can be searched and analyzed on database. 3. The resolution of image data stored in optical card is above 5.9 lp/mm. 4, All data of dental charts used as samples, stored to optical cards, occupies average 14%, In conclusion, with the development of the storage system using the optical card, a dental patient's life-time treatment record can be stored in one optical card and used as a substitute for the dental chart.

  • PDF

Influence of Digital Experience Factors on Purchase - Focusing on Moderating Effects of Digital Experience Frequency - (디지털 경험 요소가 구매에 미치는 영향 -경험빈도의 조절효과를 중심으로-)

  • Jung, Sang Hee;Chung, Byoung Gyu
    • Journal of Venture Innovation
    • /
    • v.3 no.2
    • /
    • pp.23-39
    • /
    • 2020
  • The 4th Industrial Revolution and Covid 19 are moving the fashion industry from offline to online. Fashion shows that took place offline are being replaced by online. Online is greatly increasing consumers' digital customer experience based on digital technologies. In this study, we studied the effect of digital experience factors on digital customer satisfaction based on the Schmitt(1999)'s experience marketing. The effect of digital customer satisfaction on purchase, continuous use intention, and recommendation intention were also studied. In addition, the moderating effect of experience frequency was studied. We randomly sampled 180 individuals among fashion mall users.. SPSS 24, AMOS 23 and Process Macro 3.5 were used for statistical analysis. In the study in which digital experience factors influence digital customer satisfaction, all except the digital act showed positive influence. The impact of influence was digital sense (β = .366) > digital think (β = .225)> digital feel (β = .191) > digital relate(β = .163). Digital customer satisfaction have been positive impact on purchasing, continuance use and recommendation intention. In the moderating effect of digital experience frequency, between digital feel, digital act and digital customer experience showed a statistically effective relationship. Based on the this study, We suggested theoretical and practical implications.

Evaluation of the color reproducibility of all-ceramic restorations fabricated by the digital veneering method

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.71-78
    • /
    • 2014
  • PURPOSE. The objective of this study was to evaluate the clinical acceptability of all-ceramic crowns fabricated by the digital veneering method vis-$\grave{a}$-vis the traditional method. MATERIALS AND METHODS. Zirconia specimens manufactures by two different manufacturing method, conventional vs digital veneering, with three different thickness (0.3 mm, 0.5 mm, 0.7 mm) were prepared for analysis. Color measurement was performed using a spectrophotometer for the prepared specimens. The differences in shade in relation to the build-up method were calculated by quantifying ${\Delta}E^*$ (mean color difference), with the use of color difference equations representing the distance from the measured values $L^*$, $a^*$, and $b^*$, to the three-dimensional space of two colors. Two-way analysis of variance (ANOVA) combined with a Tukey multiple-range test was used to analyze the data (${\alpha}$=0.05). RESULTS. In comparing means and standard deviations of $L^*$, $a^*$*, and $b^*$ color values there was no significant difference by the manufacturing method and zirconia core thickness according to a two-way ANOVA. The color differences between two manufacturing methods were in a clinically acceptable range less than or equal to 3.7 in all the specimens. CONCLUSION. Based on the results of this study, a carefully consideration is necessary while selecting upper porcelain materials, even if it is performed on a small scale. However, because the color reproducibility of the digital veneering system was within the clinically acceptable range when comparing with conventional layering system, it was possible to estimate the possibility of successful aesthetic prostheses in the latest technology.

Design of a High-Resolution DCO Using a DAC (DAC를 이용한 고해상도 DCO 설계)

  • Seo, Hee-Teak;Park, Joon-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1543-1551
    • /
    • 2011
  • Dithering scheme has been widely used to improve the resolution of DCO(Digitally Controlled Oscillator) in conventional ADPLLs(All Digital Phase Locked Loop). In this paper a new resolution improvement scheme is proposed where a simple DAC(Digital-to-Analog Converter) is employed to overcome the problems of dithering scheme. The frequencies are controled by varactors in coarse, fine, and DAC bank. The DAC bank consists of an inversion mode NMOS varactor. The other varactor banks consist of PMOS varactors. Each varactor bank is controlled by 8bit digital signal. The proposed DCO has been designed in a $0.13{\mu}m$ CMOS process. Measurement results shows that the designed DCO oscillates in 2.8GHz~3.5GHz and has a frequency tuning range of 660MHz and a resolution of 73Hz at 2.8GHz band. The designed DCO exhibits a phase noise of -119dBc/Hz at lMHz frequency offset. The DCO core consumes 4.2mA from l.2V supply. The chip area is $1.3mm{\times}1.3mm$ including pads.

A Study on the Noise Improvement of All Digital Phase-Locked Loop Using Time-to-Digital Converter (시간-디지털 변환기를 이용한 ADPLL의 잡음 개선에 대한 연구)

  • Ahn, Tae-Won;Lee, Jongsuk;Lee, Won-Seok;Moon, Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.195-200
    • /
    • 2015
  • This paper presents SVBS-TDC (Semi-Vernier Binary-Search Time-to-Digital Converter) for the noise improvement of ADPLL (All-Digital Phase Locked Loop. We used a Semi-Vernier BS-TDC (Binary-Search TDC) architecture to improve the operation speed more then 10 times compared with the previous conventional BS-TDC and ensured a 510ps wide input range. The proposed Semi-Vernier BS-TDC was designed in a 65ns CMOS process and the simulation results showed 200MHz speed and 4ps resolution with a 1.2V supply voltage, and considerable noise improvement of ADPLL.

An Offset and Deadzone-Free Constant-Resolution Phase-to-Digital Converter for All-Digital PLLs (올-디지털 위상 고정 루프용 오프셋 및 데드존이 없고 해상도가 일정한 위상-디지털 변환기)

  • Choi, Kwang-Chun;Kim, Min-Hyeong;Choi, Woo-Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.122-133
    • /
    • 2013
  • An arbiter-based simple phase decision circuit (PDC) optimized for high-resolution phase-to-digital converter made up of an analog phase-frequency detector and a time-to-digital converter for all-digital phase-locked loops is proposed. It can distinguish very small phase difference between two pulses even though it consumes lower power and has smaller input-to-output delay than the previously reported PDC. Proposed PDC is realized using 130-nm CMOS process and demonstrated by transistor-level simulations. A 5-bit P2D having no offset nor deadzone using the PDC is also demonstrated. A harmonic-lock-free and small-phase-offset delay-locked loop for fixing the P2D resolution regardless of PVT variations is also proposed and demonstrated.

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

Reconstruction of the Soft Tissue Defect of the Finger Using Digital Island Flap with Supercharged Vein (손가락섬피판으로 손가락 연조직 재건시 과급정맥문합)

  • Choi, Hwan Jun;Kim, Nam Joong;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • Purpose: The heterodigital or homodigital artery island flap is a popular method of reconstruction for finger defects. Sometimes, digital artery island flap has some disadvantages such as postoperative flap edema, congestion, and partial necrosis of the flap margin. However, we could decrease these disadvantages by means of venous superdrainage. The aim of this study is to report usefulness and postoperative results of venous supercharging digital artery island flaps for finger reconstruction. Methods: From March of 2005 to March of 2008, a total of eight patients with soft tissue defects of the finger underwent venous supercharging digital island flap transfer. Briefly, the flap is harvested along with dorsal vein that is then anastomosed to a recipient vein in an end - to - end fashion, after flap transfer and insetting. Using this technique, eight patients were operated on, ranging in age 23 to 52 years. Results: All the flaps survived with a success rate of 100 percent, thus fully satisfying the reconstructive requirements. No postoperative flap congestion was recognized, obviating the need to take any measures for venous engorgement, such as suture removal. Among 8 cases, it was possible to make an long - term and follow - up observation more than 6 months. In these cases, the fact that light touches and temperature sensations can be detected in all the flaps. Cold intolerance and hyperesthesia were not seen in our series. Conclusion: Providing good harmony with conventional methods and microsurgery, inclusion of a vein with the heterodigital and homodigital artery island flap allows a more reliable and safer reconstructive choice for finger defects. The venous supercharged island flap is a reliable flap with a consistent arterial structure, and with its augmented venous drainage, it is more reliable, providing single - stage reconstruction of adjacent finger defects, including the fingertip.

The Effects of Hearing Aid Digital Noise Reduction and Directionality on Acceptable Noise Level

  • Ahmadi, Roghayeh;Jalilvand, Hamid;Mahdavi, Mohammad Ebrahim;Ahmadi, Fatemeh;Baghban, Ali Reza Akbarzade
    • Clinical and Experimental Otorhinolaryngology
    • /
    • v.11 no.4
    • /
    • pp.267-274
    • /
    • 2018
  • Objectives. Two main digital signal processing technologies inside the modern hearing aid to provide the best conditions for hearing aid users are directionality (DIR) and digital noise reduction (DNR) algorithms. There are various possible settings for these algorithms. The present study evaluates the effects of various DIR and DNR conditions (both separately and in combination) on listening comfort among hearing aid users. Methods. In 18 participants who received hearing aid fitting services from the Rehabilitation School of Shahid Beheshti University of Medical Sciences regularly, we applied acceptable noise level (ANL) as our subjective measure of listening comfort. We evaluated both of these under six different hearing aid conditions: omnidirectional-baseline, omnidirectional-broadband DNR, omnidirectional-multichannel DNR, directional, directional-broadband DNR, and directional-multichannel DNR. Results. The ANL results ranged from -3 dB to 14 dB in all conditions. The results show, among all conditions, both the omnidirectional-baseline condition and the omnidirectional-broadband DNR condition are the worst conditions for listening in noise. The DIR always reduces the amount of noise that patients received during testing. The DNR algorithm does not improve listening in noise significantly when compared with the DIR algorithms. Although both DNR and DIR algorithms yielded a lower ANL, the DIR algorithm was more effective than the DNR. Conclusion. The DIR and DNR technologies provide listening comfort in the presence of noise. Thus, user benefit depends on how the digital signal processing settings inside the hearing aid are adjusted.