• 제목/요약/키워드: all ceramic

검색결과 1,135건 처리시간 0.027초

타이타니아 단섬유상의 석출이 결정화유리의 마모특성에 미치는 영향 (Effects of Titania Whisker Precipitation on Wear Property of the Glass-Ceramic)

  • 이경호
    • 한국세라믹학회지
    • /
    • 제33권2호
    • /
    • pp.192-202
    • /
    • 1996
  • In Li0.4Ca0.05AlP0.5Si0.75O4.5 composition glass, glass-ceramic having a near 100% crystallinity after nucleation heat treatment of 74$0^{\circ}C$/2 h and crystallization heat treatment of 90$0^{\circ}C$/2 h and in-situ TiO2 whisker reinforced glass-ceramic after heat treatment of 105$0^{\circ}C$ for 20 h were fabricated with the addition of 4% TiO2 as a nucleating agent. With these materials a ball-on-disc type wear test was conducted in order to examine the effect of TiO2 whisker prepcipitation on ambient and high temperature wear properties of the glass-ceramic. Wear test results indicated that all specimens exhibited micro-fracture wear mechanism in ambient temperature. As temperature increased the wear rates of the materials were increased. However the in-situ TiO2 whisker reinforced glass-ceramic exhibited the lowest wear rate over the test temperature range. This resulted from the improvement of harness and fracture toughness of the material as the glass converted into the glass-ceramic followed by precipitation of TiO2 whiskers throughout the glass-ceramic matrix.

  • PDF

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

알루미나 테이프를 사용한 유리 침투형 알루미나 코아의 변연적합도 (MARGINAL FIT OF GLASS INFILTRATED ALUMINA CORE FABRICATED FROM ALUMINA TAPES)

  • 오남식;이명현;김대준;이근우;이선형
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.832-845
    • /
    • 1998
  • The purpose of this study was to compare the marginal fit of all ceramic crowns prepared from alumina slip casting, which is consistent with the conventional In-ceram system, and those fabricated from alumina tapes which is currently under development in an effort to alleviate complexities involved in the forming procedure of the In-ceram crown core. All ceramic crowns, made of In-ceram(slip casting) and alumina tapes(Doctor blade casting), were prepared with $90^{\circ}\;and\;135^{\circ}$ shoulder margins. The crowns were cemented with a glass ionomer cement and embeded in epoxy resin. The embedded crowns were sectioned faciolingually and mesiodistally and marginal discrepancies and marginal gaps were measured under the Measurescope MM II. The measurements were analyzed using Wilcoxon rank sum test and Kruskal-Wallis test and the results were as follows: 1. In the case of $90^{\circ}$ shoulder margin, the combined marginal discrepancies and marginal gaps were $78.3{\mu}m\;and\;44.4{\mu}m$ respectively, for the all ceramic crowns fabricated using the alumina tapes. In comparison, the values were $65{\mu}m\;and\;25.5{\mu}m$ for the In-ceram crowns. For the marginal gaps a statistical difference existed (p<0.05) but no significant difference was observed for the marginal discrepancy (p>0.05). 2. In the case of $135^{\circ}$ shoulder margin, the combined marginal discrepancy and marginal gaps were $82.1{\mu}m\;and\;40.2{\mu}m$ respectively, for the all ceramic crowns formed with the tapes. As compared with the marginal discrepancy and gaps of the $90^{\circ}$ shoulder margin in the fabricated from the alumina tapes, no significant statistical differencies were discerned in both cases (p>0.05). 3. There was no statistically significant difference in the fits among four locations around the margins of the all ceramic crowns fabricated using the alumina tapes. The results obtained in this study showed that the marginal fits of the glass infiltrated alumina cores fabricated from the alumina tapes are slightly higher value than those prepared using the In-ceram but the difference is within a clinically acceptable range.

  • PDF

CAD/CAM 및 카피밀링 시스템을 이용하여 제작한 구치부 3-유닛 고정성 국소의치의 파절강도 (Fracture Strength of All-Ceramic 3-Unit Fixed Partial Dentures Manufactured by CAD/CAM and Copy-Milling Systems)

  • 강후원;김희진;김장주;고명원
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.95-103
    • /
    • 2012
  • Purpose: Fracture strength of all-ceramic 3-unit fixed partial dentures manufactured by CAD/CAM and copy-milling systems were evaluated. Methods: Zirconia cores were made by milling the pre-sintered zirconia block by CAD/CAM or copy milling method followed by subsequent sintering. By building-up the corresponding porcelains on the core, all-ceramic bridges were fabricated, and those were evaluated in comparison with PFM fixed partial denture. Results: During the flexural test of the 3-unit PFM bridge, the porcelain started to chip or break at 507.28(${\pm}62.82$)kgf and the metal framework did not break until the maximum load level of 800kgf which was set in the testing instrument of this study. However, among all-ceramic restoration test groups, Everest(EV) group showed a peeling off or breakage of the porcelain from 365.64(${\pm}64.96$)kgf and the core was broken at 491.77(${\pm}55.62$)kgf. Those values of Zirkonzahn(ZR) were 431.03(${\pm}58.47$)kgf and 602.74(${\pm}48.44$)kgf, respectively. The break strength of the porcelain of PFM(PM) group was significantly higher than that of EV (p<0.05) group and there was no significant difference when comparing to that of ZR (p>0.05). ZR group showed higher break strength than that of EV group however there was no significant difference (p>0.05). The break strength of cores were in the increasing order of EV < ZR < PM (p<0.05). Conclusion: We could find that even though the PM group fractured at much higher value than all-ceramic cores, the breakage values of the porcelain of PM group with crack formation or delamination, which will be regarded as clinical failure, was significantly higher than that of EV group and not significantly higher than that of ZR group at p-values of 0.05. The break strength of ZR group was higher than that of EV group at an insignificant level(p>0.05).

수종 전부도재관의 파절강도에 관한 비교연구 (A STUDY ON THE FRACTURE STRENGTH OF ALL-CERAMIC CROWNS)

  • 백승진;양재호
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.611-633
    • /
    • 1995
  • The pupose of this study was to compare the fracture strength of five kinds of all-ceramic crowns(Vintage, Dicor Empress-staining, Empress-layering, In-Ceram) luted with glass ionomer cerment and composite resin cement and to evaluate the effect of cements on the fracture stregth of all ceramic crowns. Five groups of twelve uniform sized all-ceramic crown specimens were fabricated. Six specimens of each group were cemented with glass ionomer cement(Fuji G.I. Cement) and the remaining six specimens of each group were etched, silane-treated, and cemented with composite resin cement(Bistite resin cement). The crowns were stored in water$(37^{\circ}C)$ for 1 day prior to loading in an Instron, using a steel ball(diameter 4mm) at a crosshead speed of 0.5mm/min. The crowns were angled $30^{\circ}$, so the steel ball contacted with the crowns 2mm lingual from the mid-incisal edge. The results obtained were summarized as follows ; 1. With G.I. cement, mean fracture load(Kg) Were : Intage : $18.33{\pm}1.47$ ; Empress-staining : $23.92{\pm}6.67$ ; Dicor : $24.0{\pm}5.81$ ; Empress-layering : $26.92{\pm}2.80$ ; In-Ceram : $51.58{\pm}6.87$ ; ANOVA revealed a significant difference existed(p<0.05) between the group A(Vintage, Dicor, Empress-staining, Empress-layering) and group B(In-Ceram). 2. With Resin cement, mean fracture load(Kg) were : Intage : $22.75{\pm}4.97$ ; Dicor : $42.75{\pm}7.07$ ; Empress-staining : $44.08{\pm}7.99$ ; Empresslayering : $50.42{\pm}5.43$ ; In-Ceram : $52.58{\pm}6.51$ ; ANOVA revealed a significatnt difference existed(p<0.05) between the group A(Vintage) and B(Dicor, Empress-staining Empress-alyering, In-Ceram). 3. Resin cement significantly increased the fracture strength of the all-ceramic crowns for Dicor(156%), Empress-staining(185%), Empress-alyering(187%)(p<0.05); but did not increase the fracture strength of Vintage(128%) and In-Ceram(101%)(p>0.05). 4. Majority of the all-ceramic crowns show a wedge fracture extending through proximal surfaces to an apex, usually apical third(with G.I. cement) or middle third(with Resin cement) of the facial surface.

  • PDF

Fabrication of a metal-ceramic crown to fit an existing partial removable dental prosthesis using ceramic pressed to metal technique: a clinical report

  • Seo, Jae-Min;Ahn, Seung-Geun
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.241-244
    • /
    • 2014
  • Fabricating a crown to retrofit an existing abutment tooth for a partial removable dental prosthesis (PRDP) is one of the most time-consuming and labor-intensive clinical procedures. In particular, when the patient is concerned with esthetic aspects of restoration, the task of fabricating becomes more daunting. Many techniques for the fabrication of all-metallic or metal-ceramic crowns have been discussed in the literature. This article was aimed to describe a simple fabrication method in which a retrofitting crown was fabricated for a precise fit using a ceramic-pressed-to-metal system.

생체활성 유리 골 시멘트의 응결 및 수산화 아파타이트 형성 (Setting and Hydroxyapatite Formation of Bioactive Glass Bone Cement)

  • 임형봉;김철영
    • 한국세라믹학회지
    • /
    • 제42권11호
    • /
    • pp.770-776
    • /
    • 2005
  • Hardening and hydroxyapatite(HAp) formation behavior of the bioactive cements in the system of $CaO-SiO_{2}-P_{2}O_{5}$ glasses and the corresponding glass-ceramics were studied. DCPD (Dicalcium Phosphate Dihydrate: $CaHPO_4{\cdot}2H_2O$) and DCPA (Dicalcium Phosphate Anhydrous: $CaHPO_4$) were developed when the prepared glass and glass-ceramic powders were mixed with three different solutions. The DCPD and DCPA transformed to HAp when the cement was soaked in Simulated Body Fluid (SBF), and this HAp formation strongly depended on the releasing capacity of $Ca^{2+}$ ions from the cements. The glass-ceramic containing apatite showed fast setting, but no HAp formation was observed because no $Ca^{2+}$ ions were released from this glass-ceramics. The compressive strength of the cements increased with reaction time in SBF until all DCPD and DCPA transformed to HAp.

치과 CAD/CAM용 복합소재를 이용한 치과보철물의 제작에 대한 연구 (A Study on Hybrid material of Making Dental restorations by CAD/CAM System)

  • 최범진
    • 대한심미치과학회지
    • /
    • 제23권2호
    • /
    • pp.86-94
    • /
    • 2014
  • In recent years, perhaps the biggest driver in new material development is the desire to improve crown and bridge esthetics compared to the traditional PFM or all-metal restorations. As such, zirconia, leucite-containing glass ceramic and lithium disilicate glass ceramic have become prominent in the dental practice. Each material type performs differently regarding strength, toughness, ease of machining and the final preparation of the material prior to placement. For example, glass ceramic are typically weaker materials which limits its use to single-unit restorations. On the other hand, zirconia has a high fracture toughness which enables multi-unit restorations. This material requires a long sintering procedure which excludes its use for fast chair side production. Developed hybrid material of CAD/CAM is contained nano ceramic elements. This new material, called a Resin Nano Ceramic is unique in durability and function. The material is not a resin or composite. It is also not a pure ceramic. The material is a mixture of both and consists of ceramic. Like a composite, the material is not brittle and is fracture resistant. Like a glass ceramic, the material has excellent polish retention for lasting esthetics. The material is easily machined chair side or in a dental lab, polishes quickly to an esthetic finish and if necessary, can be useful restoratives.

전기화학 합성 (Fabrication of Electrochemical method)

  • 이상헌;최용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.284-284
    • /
    • 2010
  • YBCO ceramic specimens were fabricated by added $BaTiO_3$ as donors and sintered $950^{\circ}C$/24hrs. Average grain size decreased with increased in added $BaTiO_3$. Affect to grain growth. XRD result, peak strength was lowed then crystallization not well all specimens. All specimens critical temperature about 90k.

  • PDF

도재소성 시 냉각속도가 전부도재관의 색조에 미치는 영향 (Effect of Shade on All Ceramic Restoration based Zirconia according to Cooling rate on Firing)

  • 전진훈;민병국;황재선;김웅철
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.199-203
    • /
    • 2015
  • Purpose: The purpose of this in vitro study was to evaluation the effect of shade on all ceramic restoration based zirconia according to cooling rate on Firing. Methods: 10 specimens applied to the dentin porcelain were made on the zirconia. After 5 specimens of the first group were burned in the furnace, these were put out rapidly. And after 5 specimens of the second group were burned in the furnace, these were put out slowly later 15 min. All specimens were measured $L^*$, $a^*$, $b^*$ using spectrophotometer, there were calculated 10 mean(SD) of descriptive statistics with SPSS program. These data were used for ${\Delta}E^*$ with color difference equation. Independent t tests were performed between 2 groups. Results: $L^*$, $a^*$, $b^*$ of 2 groups was statistically significant respectively (p<0.001), ${\Delta}E^*$ was 4.55 value. Conclusion: This study showed effect of shade on all ceramic restoration based zirconia according to cooling rate on Firing.