A Study of Two-Phase Swirl Spray Characteristics on Dual Airblast Velocity Ratio (이중공기공급 속도비에 따른 이류체 선회분무 특성 연구)

  • Kang, S.J.;Oh, J.H.;Song, K.J.;Rho, B.J.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.27-36
    • /
    • 2000
  • In this study, spray characteristics of a dual airblast atomizer are addressed. Three dimensional characteristics of a dual airblast atomizer with air swirl are measured to provide the significant data. The liquid flow rate was fixed at 0.06 kg/min, and atomizing air was controlled at the liquid-air mass ratio of 4.0. The performance of the spray with co-swirl and counter-swirl flow was investigated at each point in the developed spray region using a three-component phase Doppler particle analyzer. This instrument was also used to evaluate the concentration profiles. The three dimensional mean velocity were investigated of present flow characteristics of the dual airblast atomizer. In addition, drop size distributions, mean droplet size profile, and droplet concentration were analyzed to understand atomization characteristics. This experimental results can be conveniently utilized for the preliminary design of gas turbine engines for aircraft.

  • PDF

Inelastic two-degree-of-freedom model for roof frame under airblast loading

  • Park, Jong Yil;Krauthammer, Theodor
    • Structural Engineering and Mechanics
    • /
    • v.32 no.2
    • /
    • pp.321-335
    • /
    • 2009
  • When a roof frame is subjected to the airblast loading, the conventional way to analyze the damage of the frame or design the frame is to use single degree of freedom (SDOF) model. Although a roof frame consists of beams and girders, a typical SDOF analysis can be conducted only separately for each component. Thus, the rigid body motion of beams by deflections of supporting girders can not be easily considered. Neglecting the beam-girder interaction in the SDOF analysis may cause serious inaccuracies in the response values in both Pressure-Impulse curve (P-I) and Charge Weight-Standoff Diagrams (CWSD). In this paper, an inelastic two degrees of freedom (TDOF) model is developed, based on force equilibrium equations, to consider beam-girder interaction, and to assess if the modified SDOF analysis can be a reasonable design approach.

A Case Study of Air Ball Blasting Method (에어볼 발파공법에 의한 진동 및 폭음 계측연구)

  • Lee Shin;Kim Sang-Wook;Kang Dea-Woo
    • Explosives and Blasting
    • /
    • v.23 no.2
    • /
    • pp.15-21
    • /
    • 2005
  • Already, VARI-STEM, CAS-BAG, POWER DECK etc. are used by various blasting methods to take the advantage of air decking technology in abroad. This study analyzed the application and the effect of Air ball blasting method in domestic blasting area. It is shown that blasting vibration was showed decrease about $30\~40\%$ and quantities of explosives was shown decrease about $20\~25\%$. Also, in the case of using air ball blasting method, it is found for airblast to be lower than common blasting method.

An experimental study on the characteristics of spray pattern by the Airblast Atomizer (공기충돌형 연료분사장치의 분무특성에 관한 실험적 연구)

  • Kim, Hyun-Joong;Han, Jae-Seob;Kim, Yoo;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.24-29
    • /
    • 1998
  • An experimental study was carried out to investigate the characteristics of spray pattern such as discharge coefficient, spray angle, and mass distribution for two-fluid airblast swirl injector, within the range of fluid supply pressure 0~13kg/$\textrm{cm}^2$. In general atomization is promoted with increasing total gas mass flow and performance of the splay pattern was more stable when radial mass flow was greater than axial mass flow, radial swirler was better than Axial swirler for atomization. Equivalent spray angle did not change with water mass flow except for the condition of 3kg/$\textrm{cm}^2$ and showed the same for the gas mass flow. Mass distribution from the patternator shows that maximum value of the distribution were lowered but distributed larger area when gas flow rate increased. Center of mass position did not change with increasing water mass flow.

  • PDF

Effect of Operating Condition of Airblast Atomizer on Twin spray characteristics and interaction (공기충돌형 연료분사장치의 운용조건이 이중분무특성과 간섭효과에 미치는 영향)

  • Park, S.G.;Han, J.S.;Kim, Y.;Park, J.B.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.9-14
    • /
    • 1999
  • The effect of operating condition was studied experimently on the characteristics of twin sprays ejected from two airblast atomizers, within the range of the mass air-fuel ratio 1.36∼3.54. Water and nitrogen gas were used as test fluids for the experiments. Spray characteristics of liquid spray were measured with measurement of mass distribution and instantaneous image of the spray cone. Experimental results show that the maximum specify of the distribution were lowered but distributed over the larger area when the ROA ratio increased, Center of mass position did not change with increasing water mass flow, Increase of the nozzle distance has an small effect on mass distribution of interaction area but distributed over the larger area. It was also conformed that the effect of interaction near central point of collision decreased with the increase of the ROA ratio on interaction area from comparison using superposition method

  • PDF

Design of Venturi Dump Surface for Pre-filming Airblast Injector (예막 공기충돌형 분사기의 벤추리 덤프면 설계)

  • Shin, Dongsoo;Choi, Myunghwan;Radhakrishnan, Kanmaniraja;Koo, Jaye;Jung, Seungchai
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.44-54
    • /
    • 2018
  • In a spray experiment using a venturi mounted on a lean premixed LPP injector, droplets appear to have non-uniform distributions. To solve this problem, the exit angle of the venturi was changed to form a dump surface on the nozzle neck. The dump surface improved the atomization performance and minimized droplet loss while forming recirculation zone in the venturi exit. In order to solve the non-uniform spray of the injector, the flow characteristics inside the venturi and SMD of the spray are compared. Finally, an optimum venturi shape is selected to minimize the spray loss and improve the spray performance.

An Experimental Study on Characteristics of Twin Spray Ejected from Two Pre Filming Airblast Atomizer (두 개의 공기충돌형 연료분사장치로부터 분사되는 이중분무특성에 관한 실험적 연구)

  • Park, Seung-Gyu;Han, Jae-Seob;Kim, Yoo;Park, Jung-Bae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.6-6
    • /
    • 1998
  • 항공기용 가스터빈 및 일반적인 산업용 분무시스템에서는 많은 양의 분사액체를 미립화 시키고 시스템의 연속적인 운전과 유지를 편리하게 하기 위하여 여러 개의 분사노즐을 열로 설치하여 동시에 분사하도록 하고 있다. 이렇게 동시에 분사할 경우, 노즐간에 거리가 충분히 크지 않으면 개별적으로 분사된 분무들이 서로 합해져서 하나의 연합된 분무군이 형성된다. 이렇게 Two element에 의해서 형성된 spray는 공급압력이 증가함에 따라 관성력이 증가하게 되어 중심부분에서 액막 혹은 액적상태로서 충돌이 발생하여 복잡한 분무특성을 가질 것이다. 따라서, 연합된 분무군의 특성을 이해하는 것은 응용의 측면에서 매우 중요하다고 할 수 있다.

  • PDF

A Study on the characteristics of spray pattern in the Pre filming Airblast Atomizer (공기충돌형 연료분사장치의 분무특성에 관한 실험적 연구)

  • Kim, Hyun-Joong;Han, Jae-Seob;Kim, Yoo;Min, Sung-Gi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.27-27
    • /
    • 1998
  • 연구소기내에서 원활한 연소를 위하여 액체의 균일하고 완전한 미소분열 문제는 매우 중요한 연구분야라 할 수 있으며, 특히 항공기용 가스터빈 연소기에 사용되는 분사 시스템의 설계시에는 단순한 미소분열 문제뿐 아니라 시동성 향상, 화염의 안정화, 공해물질의 저감 등은 물론 압력 차가 작고 유량범위가 넓으며 공기를 이용한 미립화(Atomization)의 효율이 낮은 영역, 즉, 시동(Start-up) 및 플레임 아웃(Flame-out)근처의 영역에서도 효율적인 미립화가 이루어지도록 고려되어져야 한다.

  • PDF

Consideration on the Relation between Vibration Level and Peak Particle Velocity in Regulation of Ground Vibration (지반진동 규제기준에서 진동레벨과 진동속도의 상호관계에 대한 고찰)

  • Choi, Byung-Hee;Ryu, Chang-Ha
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • The only law related to airblast and ground vibration control in Korea is the Noise and Vibration Control Act enforced by the Ministry of Environment. But this law mainly deals with the annoyance aspects of noises and vibrations in ordinary human life. Hence, the law defines the safety criteria of ground vibration as the vibration level (VL) of dB(V) unit. The ground vibrations produced from blasting, however, have the unique characteristics that can be shown in shock vibrations, and the duration is also very short compared to the vibrations from machinery, tools or facilities. Hence, vibration regulations for blasting operations usually define the safety criterion as the peak particle velocity (PPV) considering the effect of ground vibrations to structural damage. Notwithstanding, there are several attempts that predict VL from PPV or estimate VL based on the scaled distances (SD; in unit of $m/kg^{1/2}$ or $m/kg^{1/3}$) without considering their frequency spectra. It appears that these attempts are conducted mainly for the purpose of satisfying the law in blasting contracts. But, in principle there could no correlation between peaks of velocity and acceleration over entire frequency spectrum. Therefore, such correlations or estimations should be conducted only for the waves with the same or very similar frequency spectra.

A Case Study of Air Deck Blasting Method (Air Deck 발파공법의 현장적용에 관한 연구)

  • Lee Shin;Kim Sang-Wook;Kang Dea-Woo
    • Tunnel and Underground Space
    • /
    • v.16 no.2 s.61
    • /
    • pp.156-165
    • /
    • 2006
  • Already, vari-stem, gas-bag, power deck, air ball etc. are used by various blasting methods to take the advantage of air decking technology in abroad. Air tube product has been used continuously in domestic and air ball product was made recently. In the case study, we analyzed about the application and the effect or air deck blasting method in domestic blasting area. As results or this case study, it was shown that blasting vibration was decreased about $21{\sim}41%$ and quantities or explosives was decreased about $17{\sim}30%$. Also, in the case of using air deck blasting method, fragmentation was shown to be smaller than common blasting method.