• 제목/요약/키워드: air-tightness

검색결과 120건 처리시간 0.022초

국내외 공동주택용 창호의 기준 및 성능 조사 (The investigation into the standards and performances of domestic and foreign windows for an apartment house)

  • 송수빈;김영탁;염성곤;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.330-335
    • /
    • 2008
  • This research aims to investigate the standards and the performances of domestic and foreign windows for and apartment house and to present fundamental data for selecting the optimum window at the step of designing an apartment house. To compare the performances of domestic and foreign windows it is selected 5 major window companies in and 3 major window companies in Japan, and investigated window structure, material, type of opening and closing, window glass and the performances of windows for an apartment house-closing and opening force, repeated closing and opening, thermal resistance, sound transmission loss, air tightness, water tightness, wind resistance. The result of a comparative analysis show that the average thermal resistance of Korean window is higher than Japan's but the average sound transmission loss and water tightness of Korean window is lower than Japan's and the rest of the performances is similar.

  • PDF

수평 구름 바퀴가 적용된 신 유형 미서기 창문의 기밀성능 개선에 관한 연구 (A Study on the Enhance of Air tightness Performance of a New Type Silding Window with horizontally Rolling Wheels)

  • 장혁수;김영일;정광섭
    • 에너지공학
    • /
    • 제24권4호
    • /
    • pp.63-70
    • /
    • 2015
  • 창문에서의 틈은 열 손실 뿐만 아니라 차음 성능에도 중대한 결함으로 작용되며, 특히 인체에 유해한 미세먼지 유입 경로로도 작용된다. 이러한 틈을 제거하기위해 많은 시도들이 이루어지고 있으나, 창문의 고유 기능인 이동특성으로 인해 해결하기 어려운 난제로 인식되어왔다. 본 연구는 이를 해결하기위해 수평 회전 휠과 곡선 레일을 적용한 새로운 유형의 미서기 창문을 제작하고, KS 시험 기준에 따라 사용성, 내구성, 기밀성능, 등의 성능 시험을 하였다. 시험 결과, 개폐력은 2000 N 중량의 창문에서 30 N, 개폐 반복성 시험에서는 100,000 cycles, 기밀성 시험에서는 10 Pa에서 $0.00m^3/(m^2h)$의 성능을 보여주었다. 상기 시험 결과, 새로운 구동 방식을 지닌 본 연구에서의 창문은 기밀성과 경제적 측면에서 새로운 접근 방식을 제시하고 있다.

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

차음성능과 기밀성능이 향상된 경량 간막이벽 개발 (A Development of Partition Wall for enhenced Sound Transmission Loss and Air Tightness)

  • 배상환;박진우;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.855-860
    • /
    • 2001
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings. it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But. the required performances of a light-weight wall are not evaluated systematically. As a field survey result. partition walls of house-to-house and room-to-room were not showed their respected performances. so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially. occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Also to suppress indoor air movement. stact effect must be concerned. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings.

  • PDF

초고속 튜브철도 시스템을 위한 튜브 구조물의 기밀성 평가 : I. 해석모델 수립 및 재료 기밀성 (Air-tightness Evaluation of Tube Structures for Super-speed Tube Railway Systems: I. Analytical Modeling and Material Test)

  • 박주남;남성원;김이현;여인호
    • 한국철도학회논문집
    • /
    • 제14권2호
    • /
    • pp.143-150
    • /
    • 2011
  • 본 논문에서는 초고속 튜브철도 시스템의 개념설계 단계에 있어 진공튜브 구조물의 기밀성능 평가를 위한 기초 연구를 수행하였다. 먼저 Darcy의 흐름법칙에 근거하여 밀폐된 구조물의 내/외부 압력 차에 따른 공기 유입의 흐름식을 유도한 후 콘크리트 재료에 대한 투기성 평가 실험을 수행하여 콘크리트 강도에 따른 투기계수의 경향을 분석하였으며 이 결과를 바탕으로 가정 단면을 가진 튜브 구조물에 대한 내부 압력 변화를 해석적으로 모사하였다. 수립된 해석모델과 실험결과를 종합적으로 분석한 결과, 콘크리트의 투기성은 압축강도에 기하급수적으로 반비례하며 진공튜브 구조물에 콘크리트 재료를 적용하였을 경우 적어도 50MPa 이상의 압축강도를 갖는 콘크리트를 사용하는 것이 진공펌프의 운용 및 유지관리 측면에서 유리할 것으로 나타났다.

신축 공동주택에서 감압법을 이용한 기밀성능 실측 연구 (Field Measurement of Infiltration in New Apartments using De-pressurization Method)

  • 윤재옥
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.27-32
    • /
    • 2013
  • Infiltration is air flow that occurs through cracks in buildings. According to level and kind of infiltration, the cooling load and heating load in buildings may increase. In this study I conducted field measurements to evaluate air tightness in 27 new apartment units. Field measurements for new apartments was the focus. For the de-pressurization method, the equipment utilized to gauge airtightness included KNS-5000C and KNS-4000 which were installed on the window in order to measure indoor air leakage. The results are summarized as follows. The average ACH50 of a $59m^2$ APT was 3.98, 3.82 for a $84m^2$ APT, and 2.73 for a $114m^2$ APT. The total average ACH50 of 27units was 3.51.

Stack Effect in High-Rise Buildings: A Review

  • Mijorski, Sergey;Cammelli, Stefano
    • 국제초고층학회논문집
    • /
    • 제5권4호
    • /
    • pp.327-338
    • /
    • 2016
  • This technical paper presents a detailed review of the stack effect phenomenon and of the associated implications pertaining to the design and construction of high-rise buildings in regions of extreme climatic conditions. The present review is focused on both the classical 'chimney' effect as well as on the reverse stack effect, which are respectively related to cold and hot climates. For the purposed of the work here presented, the ASHRAE (2013) design conditions of Astana (Kazakhstan) and Riyadh (Kingdom of Saudi Arabia) were selected. A 230 m tall residential building of rectangular floor plan was numerically modelled in the context of the climatic conditions of the two abovementioned cities and a number of sensitivity analyses were performed, covering parametric changes of: temperature, façade air tightness, site wind speeds and wind directions.

에너지효율화를 위한 창호 유형별 기밀 및 단열성능에 관한 조사 연구 (A Research on Air-tightness and Thermal performance of windows system classified by Windows type)

  • 최경석;강재식;양관섭;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.120-123
    • /
    • 2009
  • 건물에서 에너지손실이 큰 창호에 대해 최저소비효율기준 및 에너지소비효율 등급기준(안) 도입을 통해 지속가능한 고효율 창호의 보급 활성화 촉진과 관련 산업의 기술 및 산업력 향상을 적극적으로 유도할 필요가 있다. 이에 본 연구에서는 창호의 에너지 효율화를 위하여 고효율기자재(고기밀성 단열창호)로 인증받은 약 100여개 제품과 기타 제품에 대하여 창호 유형별 기밀 및 단열성능의 조사 분석을 통하여 창호 관련 제도 개정에 기초자료로 활용 에너지절약과 기후변화협약 관련 건물부문의 구체적 실천 대응방안으로 활용하고자 한다.

  • PDF

차음성능이 향상된 경량벽체 개발 및 성능평가 연구 (A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System)

  • 이병권;배상환;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

유기용제 함침법을 통한 알루미늄 다이캐스팅의 미세결함 및 기밀성 평가 (Evaluation of Micro-defects and Air Tightness of Al Die-casting by Impregnation of Organic Solvent)

  • 이진욱;조창현;김성계;고영건;김동주
    • 한국주조공학회지
    • /
    • 제42권4호
    • /
    • pp.218-225
    • /
    • 2022
  • 본 연구에서는 고압 다이캐스팅 (High pressure die-casting, HPDC)을 통해 알루미늄 합금 (상업코드: ALDC12종)으로 수소 자동차용 부품 (Air pressure control valve housing, APCVH)을 제조하였으며 주조품의 기밀성을 향상시키기 위해 유기 함침액을 개발하였다. 개발된 2종류의 유기 함침액 (INNO-series, 한국)과 상용 합침액 (P601, 일본)을 사용하여 함침공정 조건 및 후 처리에 따른 미세결함과 기밀성을 비교 평가하였다. 컴퓨터 단층촬영 및 3차원 X-선 현미경 분석을 통해 함침된 알루미늄 주조품의 결함제어 및 성능 개선을 확인하였다. 또한, 함침 공정 후 기밀성 시험에서 INNO-01이 함침된 시료의 경우 성능 개선율이 70%인 것으로 확인하였다. 따라서, 개발된 유기 함침액은 상용 가능하며 다이캐스팅 제품의 기밀성 향상에 도움이 될 것으로 판단된다.