• Title/Summary/Keyword: air-entrainment

Search Result 171, Processing Time 0.021 seconds

Experimental Study of Check Valves in Pumping Systems with Air Entrainment

  • Lee, Thong-See;Low, Hong-Tong;Nguyen, Dinh-Tam;Rong, Wei;Neo, Avan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.140-147
    • /
    • 2008
  • An experiment setup was introduced to study dynamic behaviour of different types of check valves and the effects of air entrainment on the check valve performance under pressure transient condition. The experiment results show that the check valves with low inertia, assisted by springs or small traveling distance/angle gave better performance under pressure transient condition than check valves without these features. Air entrainment was found to affect both wave speed and reverse velocity. With the increase of the initial air void fraction in pipeline, the experiment results show that the wave speed was reduced, the reverse velocity was increased. The first peak pressure increased initially and then decreased with the increase of the initial air void fraction, the pressure surge periods were increased proportionally with air void fraction due to the greatly reduced wave speed. The study can be applied to help choosing suitable check valves for a particular pumping system.

Pressure Drop and Refrigerant-Entrainment Characteristics of the Eliminators used in Absorption Chillers (흡수식 냉동기용 엘리미네이터의 압력손실 및 액적유입 특성)

  • 정시영;류진상;이상수;이정주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.109-115
    • /
    • 2003
  • The performance of two vertical-blade eliminators (V1, V2) and two horizontal-blade ones (H1, H2) for absorption chillers were tested in terms of pressure drop and refrigerant entrainment. The test was carried out using a wind tunnel with a cross section of 300 mm$\times$300 mm. The pressure drop of four eliminators tested was found to be in the rage of 1.0~2.7mm $H_2O$ at the face velocity of 2m/s. In the refrigerant entrainment test the vertical-blade eliminators showed much better performance than the horizontal-blade ones. The horizontal-blade eliminators showed satisfactory results at the air velocity of 2m/s but exceeded the limit value at 3 m/s. Since the cooling capacity of a machine is lowered by about 2.5% at the pressure drop of 1 m $H_2O$, more researches are required to reduce the pressure drop in the eliminator.

Jet Entrainment Effect in Buoyant Jet and Iso-Thermal Fire Modeling (부력제트의 주위공기 유입효과 및 등온기체 모델링)

  • Lee, Eui-Ju
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.111-115
    • /
    • 2009
  • Acetone LIF and Rayleigh scattering measurements were performed to identify the entrainment of ambient air in the buoyant jet qualitatively. The air entrainment near nozzle exit was enhanced with increasing both an axial distance and Reynolds number. The results supported that the air entrainment had to be considered in isothermal model for the development of its accuracy. Also, this paper provided an isothermal model based on the ideal plume, of which radiative heat loss fraction was assumed to 0.35 and the entainment of isothermal jet was considered. This simple model could be used in compartment or semi-enclosure fires such as tunnel, and it is more reliable because of introducing entrainment effect in isothermal jet.

Experimental and Numerical Study on the Air-assist Atomizer Spray Droplets (2유체 분무 액적의 거동에 관한 실험 및 수치 해석적 연구)

  • Kim, D.I.;Oh, S.H.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.65-76
    • /
    • 1998
  • An experimental and numerical study of a spray flow is performed to investigate the spray characteristics using an air-assisted atomizer. A Partical Dynamic Analyzer(PDA) is used to measure SMD, dmp velocity, and drop number density whose the initial conditions have considerable effect on the numerical results. The measured experimental data have been used to asses the accuracy of model predictions. Numerical investigation is made with the Eulerian - Lagrangian formulism. Turbulent dispersion effects using a Monte-Carlo method, turbulent modulation effect and entrainment of air are also numerically simulated. Results show that the numerical predictions of SSF(Stochastic Separated Flow) analysis yielded reasonable agreement with the experimental data. However, the model calculations for small drops produced the inconsistent numerical results due to the effect of surrounding air entrainment.

  • PDF

Flow Characteristics in Nappe Flow over Stepped Drop Structure

  • Kim, Jin Hong;Woo, Hyo Seop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.54-61
    • /
    • 2004
  • This paper deals with flow characteristics on the air entrainment and the energy dissipation in nappe flow over the stepped drop structure. Nappe flow occurred at low flow rates and for relatively large step height Dominant flow features include an air pocket, a free-falling nappe impact and a subsequent hydraulic jump on the downstream step. Air entrainment occurred from the step edge, through a free-falling nappe impact and a hydraulic jump. Most energy was dissipated by nappe impact and in the downstream hydraulic jump. It was related with the step height and the overflow depth, but not related with step slope. The stepped drop structure was found to be effcient for water treatment and energy dissipation associated with substantial air entrainment.

  • PDF

Prediction of the Flow Characteristics of Jet Fan in a Confined Space (제한공간에 설치된 제트팬의 기류특성 예측)

  • 이재헌;환유준;김경환;임윤철;오명도;김종필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.206-213
    • /
    • 2002
  • In this paper, the flow characteristics of an axial fan spraying isothermal compact jet in a confined space were investigated by the experimental methods, the numerical method, and the free jet theory According to the results, the numerical result and the experimental result are agreed well qualitatively and different quantitatively within $\pm1.0%$ for the centerline velocity, the entrainment ratio, and the maximum throw. However, the free jet theory can reasonably predict the centerline velocity except the entrainment ratio and the maximum throw. In other words, the entrainment ratio and the maximum throw by 1.he free jet theory are hard to estimate the characteristics of jet because of restriction of c confined space.

The Droplet Size Distribution of Fan Spray at Different Surrounding Conditions (팬형분무의 주변조건에 따른 입자분포 변화)

  • Moon, Seok-Su;Choi, Jae-Joon;Bae, Choong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.611-619
    • /
    • 2007
  • In this study, the droplet size distribution of a slit injector at different surrounding conditions, such as air flow and fuel temperature, were investigated. Phase Doppler anemometry (PDA) was utilized to investigate the initial droplet size distribution and the effect of fuel temperature and air flow on droplet size distribution. The entrained air motion was also evaluated by the temporal velocity profile of droplets. When the air flow velocity increased, the small droplets were more entrained to the upper and central parts of the spray and this tendency was confirmed by plotting the temporal velocity profile of droplets. This entrainment of small droplets at high airflow velocities caused relatively small mean droplet size at upper and central parts of the spray and the large mean droplet size at downstream and edge of the spray, compared to that of low airflow velocities. The total mean droplet size, obtained by averaging the size of all droplets measured at all test locations, decreased when the high airflow velocities were applied. The increased fuel temperature, with an airflow velocity of 10m/s, caused reduced droplet size at all test locations. However, the decreased value of mean droplet size at high fuel temperatures was relatively higher at upper parts of the spray, compared to downstream, as a result of enhanced entrainment of small droplets to upper parts of the spray.

Flame-Vortex Interaction and Mixing in Turbulent Hydrogen Diffusion Flames with Coaxial Air (동축공기 수소확산화염에서 화염-와류 상호작용 및 혼합)

  • Kim, Mun-Ki;Oh, Jeong-Seog;Choi, Young-Il;Yoon, Young-Bin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.149-154
    • /
    • 2007
  • This study examines the effect of acoustic excitation using forced coaxial air on the flame characteristics of turbulent hydrogen nonpremixed flames. A resonance frequency was selected to acoustically excite the coaxial air jet due to its ability to effectively amplify the acoustic amplitude and reduce flame length and NOx emissions. Acoustic excitation causes the flame length to decrease by 15 % and consequently, a 25 % reduction in EINOx is achieved, compared to a flame without acoustic excitation. Moreover, acoustic excitation induces periodical fluctuation of the coaxial air velocity, thus resulting in slight fluctuation of the fuel velocity. From phase-lock PIV and OH PLIF measurement, the local flow properties at the flame surface were investigated under acoustic forcing. During flame-vortex interaction in the near field region, the entrainment velocity and the flame surface area increased locally near the vortex. This increase in flame surface area and entrainment velocity is believed to be a crucial factor in reducing flame length and NOx emission in coaxial jet flames with acoustic excitation. Local flame extinction occurred frequently when subjected to an excessive strain rate, indicating that intense mass transfer of fuel and air occurs radially inward at the flame surface.

  • PDF

INVESTIGATION ON EFFECTS OF ENLARGED PIPE RUPTURE SIZE AND AIR PENETRATION TIMING IN REAL-SCALE EXPERIMENT OF SIPHON BREAKER

  • Kang, Soon Ho;Lee, Kwon-Yeong;Lee, Gi Cheol;Kim, Seong Hoon;Chi, Dae Young;Seo, Kyoungwoo;Yoon, Juhyeon;Kim, Moo Hwan;Park, Hyun Sun
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.817-824
    • /
    • 2014
  • To ensure the safety of research reactors, the water level must be maintained above the required height. When a pipe ruptures, the siphon phenomenon causes continuous loss of coolant until the hydraulic head is removed. To protect the reactor core from this kind of accident, a siphon breaker has been suggested as a passive safety device. This study mainly focused on two variables: the size of the pipe rupture and the timing of air entrainment. In this study, the size of the pipe rupture was increased to the guillotine break case. There was a region in which a larger pipe rupture did not need a larger siphon breaker, and the water flow rate was related to the size of the pipe rupture and affected the residual water quantity. The timing of air entrainment was predicted to influence residual water level. However, the residual water level was not affected by the timing of air entrainment. The experimental cases, which showed the characteristic of partical sweep-out mode in the separation of siphon breaking phenomenon [2], showed almost same trend of physical properties.

A Study on the Air-Entrained Properties in mortar Using Fly-ash (플라이애쉬 혼합 모르터의 공기연행특성에 대한 연구)

  • 하상욱;김진춘;노갑수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.137-140
    • /
    • 1998
  • An entrained air is important in improving freeze/thaw resistance to the concrete structures. To achieve a proper degree of air entrainment, air entraining admixtures(AEA) are typically added to the concrete mixture, but it has been noted that an increase in the carbon content(LOI) of fly ash causes problems in proper air entrainment in concrete. In this study, the entrained air content of mortar with fly ash as an additive was considered according to the mix design as a type of AEA, adding amount of fly ash and AEA, and the elapsed time. Moreover, two different types of measurement were also tired for air content.

  • PDF