• 제목/요약/키워드: air-classification

Search Result 347, Processing Time 0.025 seconds

Taxonomy of Yellow koji mold (Aspergillus flavus/oryzae) in Korea

  • Hong, Seung-Beom;Lee, Mina;Kim, Dae-Ho;Chung, Soo-Hyun;Samson, Robert A.
    • 한국균학회소식:학술대회논문집
    • /
    • 2014.05a
    • /
    • pp.25-25
    • /
    • 2014
  • Koji molds are comprised of yellow, black and white. Black and white koji molds were recently re-visited by this author and it is concluded that they consists of Aspergillus luchuesnsis, A. niger and A. tubingensis, and the most important species for alcoholic beverage production is A. luchuensis. In the case of yellow koji mold, it is comprised of Aspergillus oryzae, A. sojae and A. tamari. In the case of A. sojae, the species is scarcely isolated from nature and rarely used for industry in Korea. Aspergillus tamari is often isolated from traditional Korean Meju, a fermented soybean product, and the classification of the species is clear. However, in the case of A. oryzae, differentiation between A. oryzae and A. flavus is still in controversy. In this study, we collected 415 strains of Aspergillus flavus/oryzae complex from air, rice straw, soybean, corn, peanut, arable soil and Meju in Korea and we examined the aflatoxin producing capacity of the strains. The norB-cypA, omtA and aflR genes in the aflatoxin biosynthesis gene cluster were analyzed. We found that 367 strains (88.4%) belonged to non-aflatoxigenic group (Type I of norB-cypA, IB-L-B-, IC-AO, or IA-L-B- of omtA, and AO type of aflR), and only 48 strains (11.6%) belonged to aflatoxin-producible group (Type II of norB-cypA, IC-L-B+/B- or IC-L-B+ of omtA, and AF type of aflR). In the case of A. flavus/oryzae strains from Meju, almost strains (178/192, 92.7%) belonged to non-aflatoxigenic group and only 14 strains (7.3 %) belonged to aflatoxin-producible group. It is proposed in this study that non-aflatoxigenic strain from Meju is classified as A. oryzae, considering that Meju is food material.

  • PDF

Approach and case study on promotion of international standardization of equipment in offshore oil & gas industry (Offshore Oil & Gas산업에서의 장비 국제표준화 추진에 관한 접근방법 및 추진 사례)

  • Han, Seongjong;Seo, Youngkyun;Jung, Jung-Yeul;Park, Peum
    • Plant Journal
    • /
    • v.16 no.1
    • /
    • pp.28-33
    • /
    • 2020
  • This study analyzes the requirements for international standardization by studying the approach to international standardization of equipment and bulk materials in the offshore oil & gas industry, and describes the prioritization of standardized equipment and the result of standardization in the first stage. Currently, international standardization activities can be classified into three activities. First, international standardization activities of bulk materials led by three major domestic shipbuilders, second, JIP33 equipment standardization activities led by IOGP, and finally, And standardization activities of UEJIP equipment centered on classification society. This study classifies various international standards applied in the offshore oil & gas industry, and introduces the activities of standardization activities of class-leading equipment and actual application examples.

Standardization and Evaluation of Performance Textiles through the Consumer's On-line Reviews - Focused on Summer Knit Shirts Containing Cellulose Fibers - (인터넷 구매후기를 통한 의류제품 소재평가표준화와 소재성능평가 - 셀룰로오스 섬유를 함유한 여름용 니트 티셔츠를 중심으로 -)

  • Kwak, Soo-Kyung;Lee, Ji-Yeon;Park, Myung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.18 no.2
    • /
    • pp.177-190
    • /
    • 2016
  • On-line consumer reviews are good references for consumers to evaluate and buy apparel products. The objective of this study is to facilitate communication about performance textiles between consumers and merchandisers who buy and sell apparel products on online. The survey was based on standardizing words used in consumer reviews written after purchase of summer knit t-shirts at internet shopping mall and evaluating the performance textiles including cellulose fibers. We collected reviews of five sorts of the clothing products including cotton/modal, tencel/polyurethane, polyester/rayon, linen, cotton and selected 1000 reviews related to textiles. For classifying each word used in the reviews by the performance textiles, they were quantified applying same standards. The results were as follow: First, the standard for consumer to consider importantly was tactile sensation, appearance, pilling, thickness, dimensional stability in washing. Second, the important category of performance textiles was healthy-comfort and psychological-comfort. Third, there were difference performance textiles for consumer to recognize, e.g. cotton/modal was important to air-permeability, tencel/polyurethane was noticed about tactile sensation, polyester/rayon was perceived about pilling unlike other things, linen had a problem of clothing care-convenience, then cotton was familiar fiber to important for appearance. The last, consumers usually focused on writing the most positive or negative online reviews. Although not familiar with professional terminologies, consumers are sensitive to physical properties of textiles. Therefore, standardizing and evaluating performance textiles are expected to improve satisfaction as providing objective information to consumers considering in buying apparel products at online shopping mall and increase in revenue to manufacturer.

  • PDF

CT Findings of Persistent Pure Ground Glass Opacity: Can We Predict the Invasiveness?

  • Liu, Li-Heng;Liu, Ming;Wei, Ran;Jin, Er-Hu;Liu, Yu-Hui;Xu, Liang;Li, Wen-Wu;Huang, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1925-1928
    • /
    • 2015
  • Background: To investigate whether CT findings can predict the invasiveness of persistent cancerous pure ground glass opacity (pGGO) by correlating the CT imaging features of persistent pGGO with pathological changes. Materials and Methods: Ninety five patients with persistent pGGOs were included. Three radiologists evaluated the morphologic features of these pGGOs at high resolution CT (HRCT). Binary logistic regression was used to assess the association between CT findings and histopathological classification (pre-invasive and invasive groups). Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of diameters. Results: A total of 105 pGGOs were identified. Between pre-invasive (atypical adenomatous hyperplasia, AAH, and adenocarcinoma in situ, AIS) and invasive group (minimally invasive adenocarcinoma, MIA and invasive lung adenocarcinomas, ILA), there were significant differences in diameter, spiculation and vessel dilatation (p<0.05). No difference was found in air-bronchogram, bubble-lucency, lobulated-margin, pleural indentation or vascular convergence (p>0.05). The optimal threshold value of the diameters to predict the invasiveness of pGGO was 12.50mm. Conclusions: HRCT features can predict the invasiveness of persistent pGGO. The pGGO with a diameter more than 12.50mm, presences of spiculation and vessel dilatation are important factors to differentiate invasive adenocarcinoma from pre-invasive cancerous lesions.

Analysis of High Volume Slit Type Two-Stage Virtual Impactor for Particle Size Classification (특정크기 입자농축을 위한 대유량 슬릿형 2단 가상충돌기의 성능분석)

  • 박성호;김상수;오명도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.285-291
    • /
    • 1991
  • A two-stage slit type virtual impactor based on the concept of the single stage virtual impactor has been designed, fabricated, and evaluated for the purpose of concentrating the suspended particles in the air with the size range of 1.8-4.5 .mu.m and handling large flow volume. Monodisperse methylene blue particles have been generated with vibrating orifice aerosol generator (VOAG). The separation efficiency and concentration efficiency have been measured by the UV-visible absorption spectrometry. Previous study for a single stage virtual impactor were used to determine the design parameters such as 50% cut-off sizes and dimensions of the two stage virtual impactor. The separation efficiency curve and 50% cut-off Stokes number(cut-off sizes) are not sensitive to the nozzle Reynolds number, but sensitive to the ratio between the minor flow rate and the total flow rate, The measured concentration efficiency was compared with the maximum concentration efficiency determined by the separation efficiencies of the first and the second stages. The differences between the measured and the maximum concentration efficiencies result from the wall loss due to the deposited particles on the internal walls inside the impactor.

Separation of Unburned Carbon from Coal Fly Ash Using and Electrocyclone (電氣빠이클론을 이용한 石炭灰 중 미연탄소 저감기술 開發)

  • 조희찬;김정윤
    • Resources Recycling
    • /
    • v.10 no.3
    • /
    • pp.14-22
    • /
    • 2001
  • For the recycle of coal fly ash generated from power stations, we developed an electrocyclone system which can separate unburned carbon form coal fly ash, based on the fact that coarse fly ash particles contain higher amount of unburned carbon and unburned carbon particles are charged positively, and pure ash particles are charged negatively on contacting each other. Additionally, guide vanes were installed in the cyclone to control the cut size. Two types of electrode, stick and grid type, were designed to investigate the effect of electrode type. Results show that by introducing an electric field inside the cyclone, the yield increases by 5 to 15e1o. But the content of unburned carbon in the clean ash does not change significantly.

  • PDF

An Environmental Management Cost Estimating Method Improvement for New Multi-Housing Projects (공동주택 신축공사 환경관리비 산출방법 개선)

  • Lee, Jae-Ho;Park, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.3 s.31
    • /
    • pp.149-158
    • /
    • 2006
  • For construction projects, it is required to estimate the Environmental Management Cost(EMC) for pollution prevention, using the calculation standards prescribed in the Construction Technology Management Law(CTML). However, the EMC standards are difficult to utilize without definite site information. Therefore, it is needed a new calculation method reflecting project site information. According to the definition of EMC in the CTML, this study identifies the EMC items and classifies them into the pollution types such as air, water, noise, waste and others. With this EMC classification, the stud:』 analyzes using the SPSS the EMC for the 78 new multi-housing projects, which were executed during the past three years, 2000-2002. And then an EMC estimating matrix is developed with simple information such as site location and size of area from historical data. The proposed matrix can be effectively used to check and control budgeting and estimating the EMC of the multi-housing projects. In addition, the proposed EMC matrix are validated through a case study.

Hazard Assessment Methodology Based on Target Level of Safety for CNS/ATM System (항행 안전 시스템을 위한 안전 목표 수준 기반 위험 평가 방법론)

  • Lee, Hongseok;Jo, Sanghoon
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.4
    • /
    • pp.285-291
    • /
    • 2016
  • Safety assessment is an essential activity for developing a system in the CNS/ATM domain. Up to now, there are many reference materials, but there is nothing that definitely specifies what to do and how to apply in the CNS/ATM. Another problem is that software assurance level has to be determined for a software under development. But there is nothing that defines a determination scheme of software assurance level. To solve these problems, this paper proposes a method to conduct a hazard assessment based on target level of safety defined in ICAO Doc 9689. To be applied generally in CNS/ATM domain, it mathematically defines procedures of hazard assessment. And it defines severity classification, probability, and safety objective of a system, which are necessary for hazard assessment, and it describes a method to apply event tree analysis process in order to conduct a hazard assessment.

Distribution Characteristics and Background Air Classification of PM2.5 OC and EC in Summer Monsoon Season at the Anmyeondo Global Atmosphere Watch (GAW) Regional Station (안면도 기후변화감시소의 여름철 PM2.5 OC와 EC 분포 특성 및 배경대기 구분)

  • Ham, Jeeyoung;Lee, Meehye;Ryoo, Sang-Boom;Lee, Young-Gon
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.429-438
    • /
    • 2019
  • Organic carbon (OC) and elemental carbon (EC) in PM2.5 were measured with Sunset Laboratory Model-5 Semi-Continuous OC/EC Field Analyzer by NIOSH/TOT method at Anmyeondo Global Atmosphere Watch (GAW) Regional Station (37°32'N, 127°19'E) in July and August, 2017. The mean values of OC and EC were 3.7 ㎍ m-3 and 0.7 ㎍ m-3, respectively. During the study period, the concentrations of reactive gases and aerosol compositions were evidently lower than those of other seasons. It is mostly due to meteorological setting of the northeast Asia, where the influence of continental outflow is at its minimum during this season under southwesterly wind. While the diurnal variation of OC and EC were not clear, the concentrations of O3, CO, NOx, EC, and OC were evidently enhanced under easterly wind at night from 20:00 to 8:00. However, the high concentration of EC was observed concurrently with CO and NOx under northerly wind during 20:00~24:00. It indicates the influence of thermal power plant and industrial facilities, which was recognized as a major emission source during KORUS-AQ campaign. The diurnal variations of pollutants clearly showed the influence of land-sea breeze, in which OC showed good correlation between EC and O3 in seabreeze. It is estimated to be the recirculation of pollutants in land-sea breeze cycle. This study suggests that in general, Anmyeondo station serves well as a background monitoring station. However, the variation in meteorological condition is so dynamic that it is primary factor to determine the concentrations of secondary species as well as primary pollutants at Anmyeondo station.

Environmental Risk Assessment of Polyhexamethyleneguanidine Phosphate by Soil Adsorption/Desorption Coefficient

  • Chang, Hee-Ra;Yang, Kyung-Wook;Kim, Yong-Hwa
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.4
    • /
    • pp.365-370
    • /
    • 2006
  • This study was performed to determine the adsorption-desorption characteristics of polyhexame-thyleneguanidine phosphate in three different soil types of textural classification. Adsorption and desorption studies is impotent for prediction their fate and generating essential information on the mobility of chemicals and their distribution in the soil, water and air of our biosphere. The detection limit of the test substance quantified by a spectroscopic method using Eosin indicator was $0.25{\mu}g/mL$. The reproducibility of analytical method was confirmed by the preliminary test. The concentrations of polyhexamethylenequanidine phosphate in aqueous solution were $1.36{\pm}0.09,\;2.45{\pm}0.01,\;and\;$4.25{\pm}0.05{\mu}g/mL$ by a spectroscopic method using Eosin indicator. The adsorption percents of polyhexamethylenequanidine phosphate in soil were greater than 95.2% for all three test soils. The desorption percents from the adsorbed soil were less than 4.5, 4.7 and 4.7%. Therefore, the adsorption coefficient (K) were greater than 110, 111 and 116. The adsorption coefficient calculated as a function of the organic carbon content (Koc) of the test soils were greater than 9,181, 11,100, and 8,942, respectively. Therefore, the test substance, polyhexamethylenequanidine phosphate could be concluded as medium or high adsorption (>25%) and poorly desorption (<75%) in soil media. Therefore, this chemical is likely to be retained in soil media and may not pose a risk in the aquatic environment.