• 제목/요약/키워드: air-cell

검색결과 1,535건 처리시간 0.028초

A Study on the Optimization of Water Balance Control in the Intermittent PEM Fuel Cell

  • Choi, Kwang-Hwan;Yoon, Jung-In;Son, Chang-Hyo;Hong, Boo-Pyo;Bakhtiar, Agung
    • 동력기계공학회지
    • /
    • 제17권5호
    • /
    • pp.64-68
    • /
    • 2013
  • One of the water management goals in PEM fuel cell is to avoid flooding and drying in the membrane, therefore the air humidification process is required. In order to increase water removal out of the membrane, the water management system may require the dehumidification process and it also requires a large space for application, moreover the process time is slow. In conformity with this fact, this present study proposes an advanced dynamic fuel cell water management which can be an intermittent optimization control using air flow rate instead of the air humidity as an variable in the optimization process. The results of this study have shown that the membrane flooding and drying can be avoided after being assisted by air velocity controlling method.

휴대용 연료전지 시스템의 소음 저감에 대한 연구 (A Study on the Noise Reduction of a Portable Fuel Cell System)

  • 전인열;배준수;오민정;최상현;이충호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.858-861
    • /
    • 2006
  • In this paper, a study on the noise reduction in a mobile fuel cell system is presented. Among various fuel cell systems around 20W capacities designed for mobile electronic devices, the active direct methanol fuel cell (DMFC) systems have been recently developed. In such systems, the primary noise source is the air pump which provides sufficient air flow ($5{\sim}6$ liter/min) for electrochemical reaction with methanol fuel while the noise contributions from other auxiliary parts are relatively small. Especially, the discrete noise tones generated by the air pump are dominant and those frequency peaks related to the rotor harmonics are needed to be suppressed by a silencer. Therefore. the Herschel/Quinke (HQ) tubes, which use the out-of-phase cancellation of acoustic waves propagating through direct and indirect pathways, are applied to the inlet of the air pump. Performance of noise reduction with HQ silencer is analytically estimated by calculating the transmission. The length and number of thin HQ tubes are optimized to decrease the radiated noise. As a result, the sound pressure level could be successfully reduced by about 10 dB after applying three serially connected HQ tubes.

  • PDF

생활환경과 실내공기의 미생물학적 오염에 관한연구 (A Study on the Microbial Air Pollution of Urban Living and Indoor Environment)

  • 정윤희;홍준배;장윤희
    • 한국환경보건학회지
    • /
    • 제27권2호
    • /
    • pp.1-9
    • /
    • 2001
  • This study was carried out to investigate the microbial characteristics of the urban air pollution in the subway stations, streets, department stores, wholesale markets, underground shopping centers, buildings, parks, houses and apartments in the Seoul and the suburbs area. Total cell count, total mold count and the presence of opportunistic pathogens(Streptococcus pneumoniae, Klebsiella pneumoniae, Aspergillus spp., Penicillium spp.) were evaluated determine the microbial air quality. Total cell count and mold count of indoor air in the houses and apartments were 2.9$\times$10$^2$-6.3$\times$10$^2$cfu/㎥ and 60-1.8$\times$10$^2$cfu/㎥, respectively, and the department stores and wholesale markets had much lower cell count than the houses and apartments. Ground level of commercial stations were 2.6 fold higher than the general subway stations, and Apergillus spp. and Penicillium spp. which could cause the bronchus and lung diseases were detected 17 sampling site out of 45. Dust were collected from the commercial facilities and houses, and total cell and mold count of the dust were 4.3$\times$10$^3$-1.7$\times$10$^{6}$ cfu/g and 2.3$\times$10$^3$-6.5 $\times$10$^4$cfu/g, respectively. Therefore the dust might be one of the main reservoir of microorganims.

  • PDF

인산형 연료전지의 성능해석을 위한 스택내의 열전달 현상에 관한 연구 (A Study on Heat Transport Phenomena in Fuel Cell Stack for the Performance Analysis of Phosphoric Acid Fuel Cell)

  • 문덕용;구자용;서종철;김유
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1991년도 추계학술대회 논문집
    • /
    • pp.160-164
    • /
    • 1991
  • The effect of various parameters, such as temperature, current density and operating valtage on the performance of phosphoric acid fuel cell stack was studied by using numerical analysis. The utilization ratio of reaction gas, inlet condition of reaction air and cooling air, inlet condition of cooling air flow latin were changed regularly, The results showed good agreements with the existing results and experimental ones.

  • PDF

Cathode에 따른 휴대용 PEM 연료전지의 성능 변화 (Performance of the PEMFC for the mobile devices according to cathode)

  • 이세원;이강인;박민수;주종남
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.550-553
    • /
    • 2008
  • In this paper, experiments of air-breathing proton exchange membrane fuel cell (PEMFC) for mobile devices were carried out according to the cathode conditions. These conditions are defined by the cathode flow field plate type (the channel type, the open type) and the cathode surface direction. Single cell and 6-cell stack were used in this experiments. The experimental results showed that the open type cathode flow field plate gave better performance for small size PEMFCs because the open type cathode plate allowed better air convection than the channel type cathode plate. In the experiments related to the direction of the slits on the cathode flow field plate, the horizontal slit cell was better than the vertical slit cell. With respect to the cathode surface direction, when the cathode surface is placed in the direction normal to the ground, PEMFC generated more stable power in the mass transport loss region.

  • PDF

자연급기 무가습 연료전지의 Dry-out조건 (Dry-out conditions of free-breathing PEMFC with dry $H_2$ gas)

  • 박상균
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.225-230
    • /
    • 2006
  • This study investigates drying condition when a small fan is added to a operating the free-breathing proton exchange membrane fuel cells (PEMFCs) with dry $H_2$ and Air. Polarization tests were conducted on PEMFCs at cell temperatures between 30 and $50^{\circ}C$ under dry operation. In the results, the cell performance strongly depended on the cell temperature and the cathode gas stoichiometric flow rates. The cell performance increases as cell temperature decreases from 50 to $30^{\circ}C$. In the domain where the stoichiometry of air is quite large, reduction of the concentration overpotential compensated the increased internal resistance due to drying. The maximum performance was obtained at the small air flow rate beyond which flooding occurs. This indicates that the fan should be operated in the stoichiometry domain with a well designed cell structure to avoid flooding.

쌀가루 혼합빵의 관능적 품질 (Sensory Quality of Rice-Wheat Bread)

  • 조숙자;정은희
    • 한국농촌생활과학회지
    • /
    • 제6권2호
    • /
    • pp.91-97
    • /
    • 1995
  • The sensory quality and the baking property of blonds containing 10-50% of rice flour with wheat flour were analysed by QDA. As sensory characteristics, color, air cell size, air cell distribution, flavor, softness, chewiness and overall quality were evaluated. Bread could be made successfully even using up to 50% rice flour. The color, flavor, softness and chewiness were increased in rice-wheat bread especially using 10∼30% of rice flour, but in case of using 40∼50% of rice flour those characteristics were not significantly different from those of wheat bread. The size of air cell in 10∼30% rice-wheat bread was not significantly different but in 40∼50% rice-wheat bread it was increased. The distribution of air cell was more even in 10∼30% rice-wheat bread than in wheat bread, but not in 40∼50% rice-wheat bread. The overall quality of rice-wheat bread was shown to be better in 10∼30% rice-wheat bread than in wheat bread.

  • PDF

250kW급 MCFC 연료전지 시스템용 공기공급장치 개발 (Development of an Air Supply System in 250 kW MCFC Fuel Cell System)

  • 박준영;황순찬;박무룡;김영철;안국영
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.280-283
    • /
    • 2008
  • This study is concerned with development of air supply system in 250kW MCFC fuel cell system. The turbo blower is decided as an air supply system to increase the efficiency of fuel cell system. The turbo blower consists of an impeller, two vaneless diffuser, a vaned diffuser and a volute. The cascade diffuser is used to raise the efficiency of turbo blower. An aerodynamic design was done by applying the repeating design procedure including a meanline design, a 3D geometry generation and fluid dynamic calculation. It is confirmed from meanline and 3D flow analysis results that the operating range is enough and design requirements are successfully achieved. The performance test results were also included in this paper.

  • PDF

Delayed Progressive Extradural Pneumatocele due to Incomplete Sealing of Opened Mastoid Air Cell after Micro-Vascular Decompression

  • Hong, Ki-Sun;Park, Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권6호
    • /
    • pp.477-479
    • /
    • 2010
  • A case of delayed progressive extradural pneumatocele after microvascular decompression (MVD) is presented. A 60-year-old male underwent MVD for hemifacial spasm; the mastoid air cell was opened and sealed with bone wax during surgery. One month after surgery, the patient complained of tinnitus, and progressive extradural pneumatoceles without cerebrospinal fluid (CSF) leakage was observed. Revision surgery was performed and the opened mastoid air cell was completely sealed with muscle patch and glue. The patient's symptoms were resolved, with no recurrence of pneumatoceles at 6 month follow up. Progressive extradural pneumatocele without CSF leakage after posterior fossa surgery is a very rare complication. Previous reports and surgical management of this rare complication are discussed.

기관(氣管) 상피세포 생리 및 약리 실험모델로서의 공기-액체 접면 일차배양법 연구 (Studies on the Air-Liquid Interface Culture as an Experimental Model for Physiology and Pharmacology of Tracheal Epithelial Cells)

  • 이충재;이재흔;석정호;허강민
    • Biomolecules & Therapeutics
    • /
    • 제10권4호
    • /
    • pp.281-286
    • /
    • 2002
  • In this study, we intended to get a preliminary data for establishing rat tracheal surface epithelial(RTSE) cell culture system as an experimental model for physiology and pharmacology of tracheal epithelial cells. Primary culture on the membrane support and application of the air-liquid interface system at the level of cell layer were performed. The cell growth rate and mucin production rate were measured according to the days in culture. The results were as follows: this culture system was found to manifest mucocilliary differentiation of rat tracheal epithelial cells, the cells were confluent and the quantity of produced and released mucin was highest on culture day 9, the mucin was mainly released to the apical side and tbe free $^3{H}$-glucosamine which was not incorporated to process of synthesis of mucin was left on the basolateral side. Taken together, we suggest that air-liquid interface culture system can be used as a substitute for immersion culture system and as an experimental model for in vivo mucus-hypersecretory diseases.