• Title/Summary/Keyword: air-cavity

Search Result 504, Processing Time 0.02 seconds

Analysis of Microbial Contamination in Poultry Slaughtering Operations for the Application of HACCP (HACCP 적용을 위한 도계처리 공정내 미생물 오염의 분석)

  • 홍종해;권혁무;고주언
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 1996
  • The application of HACCP system, which was adopted by Codex Alimentarius Committee for the safe meat and poultry production, is one of the urgent task for competing in the world trade markets. But there have been no useful analytical studies to identify the causes of contamination in the poultry meat processing plants in Korea. This study was conducted to investigate the potential hazards during the operations by the microbiological examination for the poultry meat processing plant (20,000 birds capacity a day) located in Kangwon province. In spite of air contamination of work places, it may not directly affect the surface contamination of poultry meats. But the risk of Campylobacter jejuni/coli contamination was high. The number of total count was decreased about ten times, but remarkable changes of microbial contamination could not be recognized in each procedure during the operations. The washing water was already contaminated as much as $10^{3-6}CFU/ml$ in SPC before the operations. It means that to keep water tanks hygienic is a primary step to prevent the occurrences of microbial contamination. The overflow and recirculation of water in scalding, washing, and chilling was aslo an important factor for a hygienic control. Based on this study, the followings could be regarded as an important factors for hygenic control in the poultry slaughtering plants on a small scale. The temperature of water used for scalding should be constantly maintained on a required temperature, and the overflow rate of 1~1.5 liter per bird. The carcass surface and the body cavity should be washed thoroughly and the cross-contamination due to facilities, workers, and tools should be prevented. The chilling water sholud be maintained under 5$\circ$C of temperature with ice and overflow, and residual chlorine level of 50 ppm.

  • PDF

MARS Code Applicability Assessments for the HTGR RCCS (고온가스로 원자로공동냉각계통(RCCS)에 대한 MARS Code 적용성 평가)

  • Kang Doo-Hyuk;Kim Hyung-Seok;Chung Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.232-240
    • /
    • 2005
  • In this study, the IAEA Benchmark problems far HTR-10 and HTTR RCCS were assessed in order to assess the applicability of MARS code, a thermal-hydraulic safety analysis code developed for water reactors. The calculated results were compared with those or THERMIX, THANPACST2 code, and available experimental data. The calculated results showed generally good agreements with those obtained by the THERMIX code and THANPACST2 code. Deviations were analyzed to be originated from the simplification of complicated geometry and from the modeling capability of heat transfer characteristics in the HTGR components such as water cooler and air tooler. Especially, it was found that the radiation heat transfer in the reactor cavity played an important role in the after heat removal in the RCCS. Thus, it is concluded that MARS code can be successfully applied to the calculation of the RCCS cooling capability of the HTGR in this study.

DECOMPRESSION TREATMENT FOR ODONTOGENIC CYST IN MANDIBLE USING SPECIFIC DECOMPRESSION APPLIANCE : CASE REPORT (특별히 고안된 감압술 장치를 이용한 하악의 치성 낭종의 치료: 증례보고)

  • Kim, Kyoung-Soo;Kim, Jin-Cheol;Oh, Hae-Soo;Choi, Bin;Kil, Yong-Kab;Hong, Yong-Jae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.2
    • /
    • pp.182-186
    • /
    • 2007
  • A cyst is a pathologic lesion characterized by a cavity filled with fluid, celluar products, air, or a combination of these. Dentigerous cysts were formed around the crown of unerupted teeth. The reduced enamel epithelium persists around the crown after it has formed. Proliferation of the epithelium in a fluid-filled sac may be induced by osmotic pressure. In the first decade the most frequent location is the premolar site. In each subsequent decade the largest number of cysts are in the mandibular third molar site, with the second most frequent site being the maxillary canine. The treatment of odontogenic cyst can be mostly classified into three types of cyst enucleation, marsupialization and decompression. We should consider age of patient, anatomic structure, location and size for choosing a treatment method. Advantage of cyst enucleation is fast healing, but a injury of a surrounding structure is highly. Marsupialization is conservative treatment that can reduce the damage of a adjacent structure, but it is only limited at superficial lesion. Decompression also is conservative treatment, but it has the difficulty of the oral hygiene and the troublesome of the lavage. We present the possibility that reduces the defect of decompression and cures the lesion efficiently. We report a male patient with the dentigerous cyst developed at left mandibular third molar in this study. We used the decompression for a treatment and created special appliance to treat the lesion efficiently. We report a case of the cyst treatment that is association with efficiency of decompression appliance.

Temperature Compensation of NDIR $CO_{2}$ Gas Sensor Implemented with ASIC Chip (ASIC 칩 내장형 비분산 적외선 이산화탄소 가스센서의 온도보상)

  • Yi, Seung-Hwan;Park, Jong-Seon
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.40-45
    • /
    • 2007
  • This paper describes NDIR $CO_{2}$ gas sensor that shows the characteristics of temperature compensation. It consists of novel optical cavity that has two elliptical mirrors and a thermopile that includes ASIC chip in the same metal package for the amplification of detector output voltage and temperature sensor. The newly developed sensor module shows high accuracy ($less\;than {\pm}40\;ppm$) throughout the measuring concentration of $CO_{2}$ gas from 0 ppm to 2,000 ppm. After implementing the calculation methods of gas concentration, which is based upon the experimental results, the sensor module shows high accuracy less than ${\pm}5\;ppm$ error throughout the measuring temperature range ($15^{\circ}C\;to\;35$^{\circ}C$) and gas concentrations with self-temperature compensation.

  • PDF

A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode (마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • We developed very small parallel plate radiation detector by using our existing experience of mating radiation dosimeter and capability of analyzing characteristics of dosimeter. The radiation detector was consisted of microfilm and carbon electrode. The detector was parallel plate type of all-filled ionization chamber. The ionization chamber had been fabricated using an acrylic plate for the air cavity and carbon coated microfilm for electrical configuration. The alr gap between two electrodes was 0.48 mm. The diameters of collect electrode and guard electrode were 3.3 mm, 5 mm respectively. The diameter of high voltage electrode was 5 mm. Nominal sensitive volume of the chamber was 0.016 ㎤. The major parameters of the chamber characteristics such as leakage current, reproducibility, dose rate effect, and polarity effect were measured. The experimental results were as followings. Leakage current was 0.1 pA. Standard deviation of reproducibility was less than 0.1%. Dose rate effect was less than 1.5%. Polarity effect was less than 2.4%. These data were comparable to those of commercially available dosimetric system for QA-purpose. As the result, we found that the radiation detector consisting of the ionization chamber, microfilm and carbon electrode, was satisfactory for the purpose of the small field dosimetry in size and characteristics. In the future, We will try to refine the dosimeter for use in very small volume.

  • PDF

A study on Allergic Rhrnitis (알레르기성 비염의 임상적(臨床的) 연구(硏究))

  • Lee Hai-Ja;Park Eun-Jeong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.15 no.2
    • /
    • pp.167-175
    • /
    • 2001
  • Background : Allergic rhinitis is found in approximately 20% of the general population. And the prevalence of allergic rhinitis in the pediatric population also appears to be rising. Despite allergic rhinitis reportedly occurs very frequently, this disease is often overlooked or undertreated. The oriental medicine, allergic rhinitis is belong to the BiGu, BunChe. The symptoms are watery rhinorrhea, sneezing and nasal obstruction. The cause of disease is the weak of lung, spleen and kidney, and invasion in to nasal cavity of Poong Han etc a wrong air. Objective : To allergic rhinitis patients, we use herbal medicine and acupuncture treated. To demonstrate the effect of oriental medicine therapy in the allergic rhinitis before and after treatment. Materials and methods: Thirty five patients (18 male and 17 female) treated in our hospital between February 2001 and October 2001 were studied. Ages ranged from 10 to 56 years (mean age : 27 years). Seventy seven patients had a underlying family history (allergy or sinusitis of parents or brothers). In the past history, 63% patients have atopic disease. Illness period was from 1 month to 20 years (mean period : 5.7 year). Mean duration of treatment were 39 days. Gamihyunggyeyungyo-tang was administered mainly. Result : The symptoms of allergic rhinitis were nasal obstruction(94%), rhinorrhea(86%), itching(80%), sneezing(60%), eye itching(17%), headache(11%), nose bleeding(8%) and nose pain(6%). Compared with before and after treatment, the fourth symptoms of allergic rhinitis - sneezing, rhinorrhea, nasal obstruction and itching- improved significant statistically. (significant <0.005) Conclusion : We know that herbal medicine therapy and acupuncture were the effective treatment of Allergic rhinitis.

  • PDF

Fourier Domain Optical Coherence Tomography for Retinal Imaging with 800-nm Swept Source: Real-time Resampling in k-domain

  • Lee, Sang-Won;Song, Hyun-Woo;Kim, Bong-Kyu;Jung, Moon-Youn;Kim, Seung-Hwan;Cho, Jae-Du;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2011
  • In this study, we demonstrated Fourier-domain/swept-source optical coherence tomography (FD/SS-OCT) at a center wavelength of 800 nm for in vivo human retinal imaging. A wavelength-swept source was constructed with a semiconductor optical amplifier, a fiber Fabry-Perot tunable filter, isolators, and a fiber coupler in a ring cavity. Our swept source produced a laser output with a tuning range of 42 nm (779 to 821 nm) and an average power of 3.9 mW. The wavelength-swept speed in this configuration with bidirectionality is 2,000 axial scans per second. In addition, we suggested a modified zero-crossing method to achieve equal sample spacing in the wavenumber (k) domain and to increase the image depth range. FD/SS-OCT has a sensitivity of ~89.7 dB and an axial resolution of 10.4 ${\mu}m$ in air. When a retinal image with 2,000 A-lines/frame is obtained, an acquisition speed of 2.0 fps is achieved.

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

Determination of the Equivalent Energy of a 6 MV X-ray Beam (6 MV X-선 빔의 등가에너지 결정)

  • Kim, Jong-Eon;Park, Byung-Do
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.591-596
    • /
    • 2016
  • The purpose of this study is to determine the equivalent energy of a 6MV X-ray beam in the experiment. The half-value layer (HVL) of lead for the 6 MV X-ray beam was measured using an ionization chamber. The linear attenuation coefficients were calculated with HVL. And, the mass attenuation coefficient was obtained by dividing the linear attenuation coefficient by the density of lead. The equivalent energy of mass attenuation coefficient was determined using the photon energy versus mass attenuation coefficient data of lead given by National Institute of Standards and Technology (NIST). In conclusion, the equivalent energy of the 6 MV X-ray beam was determined to be 1.61 MeV. This equivalent energy was determined to be about 30% lower than reported by Reft. The reason is presumed to be due to the presence of an air cavity between the lead attenuators.

A Case of Xanthoma Disseminatum with Laryngeal Involvement (후두에 발생한 파종성 황색종 1예)

  • Park, Jin Su;Lee, Young Woo;Lee, Sang Hyuk;Jin, Sung Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.1
    • /
    • pp.58-62
    • /
    • 2015
  • Xanthoma disseminatum (XD) is a benign, non-Langerhans cell histiocytosis characterized by disseminated xanthomatous lesions with face, flexures, and mucosa. Most of XD develops in mucocutaneous lesions including skin, oral cavity and pharynx, however laryngeal involvement is uncommon. While the natural course of XD is usually benign and often self-limiting, but XD develop in critical anatomical locations may result in morbidity and mortality. Localized mucous lesions in oropharynx and larynx lead to dysphagia, dyspnea and air way obstruction. The diagnosis of XD was based on clinical, histological and immunohistochemical findings. The treatment is complex and non-consensual. Local treatment with cryotherapy, radiotherapy, surgery, and carbon dioxide lasers have been attempted with various results. Systemic medication with peroxisome proliferator-activated gamma receptors, statins, fenofibrate, chlorodeoxyadenosine, cyclophosphamide, doxycycline, and cyclosporine have also been reported, but none have proven particularly successful. A 59-year-old man presented with respiratory symptoms because of laryngeal involvement of XD. We had to remove the obstructive lesion for relieving the symptoms. We experienced XD in Larynx that was rare in otorhinolaryngology. So we report this case with review of literatures.

  • PDF