• 제목/요약/키워드: air void system

검색결과 70건 처리시간 0.033초

Strategies for finding the adequate air void threshold value in computer assisted determination of air void characteristics in hardened concrete

  • Duh, David;Zarnic, Roko;Bokan-Bosiljkov, Violeta
    • Computers and Concrete
    • /
    • 제5권2호
    • /
    • pp.101-116
    • /
    • 2008
  • The microscopic determination of air void characteristics in hardened concrete, defined in EN 480-11 as the linear-traverse method, is an extremely time-consuming and tedious task. Over past decades, several researchers have proposed relatively expensive mechanical automated systems which could replace the human operator in this procedure. Recently, the appearance of new high-resolution flatbed scanners has made it possible for the procedure to be automated in a fully-computerized and thus cost-effective way. The results of our work indicate the high sensitivity of such image analysis automated systems firstly to the quality of sample surface preparation, secondly to the selection of the air void threshold value, and finally to the selection of the probe system. However, it can be concluded that in case of careful validation and the use of the approach which is proposed in the paper, such automated systems can give very good estimate of the air void system parameters, defined in EN 480-11. The amount of time saved by using such a procedure is immense, and there is also the possibility of using alternative stereological methods to assess other, perhaps also important, characteristics of air void system in hardened concrete.

콘크리트 내부 공극 분석을 위한 화상분석기법의 개발 (Development of Image Analysis Techniques for Measuring Air Void System in Hardened Concrete)

  • 전인구;이봉학;윤경구;정원경
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.810-813
    • /
    • 2004
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance, and etc. Linear traverse method and point count method described at ASTM have been widely used to estimate the air void system in hardened concrete. These methods, however, are rarely used at present, because they require many efforts, are time consuming works, depend on each person's decision, and are not repeatable. Thus, new image analysis method using microscope and computer processes has been approached for analyzing air void system in hardened concrete. However, it is just in initial step. The purposes of this study were to develope an effective and reliable image analysis technique for estimating air void system in hardened concrete. The developed technique was proved to be accurate, reasonable and repeatable.

  • PDF

콘크리트 공극 분석을 위한 평면간격계수의 제안 (Proposal of Plane Spacing Factor for Analyzing Air Void System in Concrete)

  • 정원경;최성용;김성환;윤경구
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.39-47
    • /
    • 2005
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM are the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the plane spacing factor by calculation of simplicity. The plane spacing factor need two parameters that are air content and numbers of air voids in the hardened concrete. Those obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The plane spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

콘크리트 내부공극 분석을 위한 행렬간격계수 모델식의 제안 (Proposal of Matrix Spacing Factor for Analyzing Air Void System in Hardened Concrete)

  • 정원경;전인구;김용곤;이봉학
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.679-682
    • /
    • 2004
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM is the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the matrix spacing factor by calculation of simplicity. The matrix spacing factor needs two parameters that are air content and numbers of air voids in the hardened concrete. Those are obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The matrix spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

Evaluation of Air Void System and Permeability of Latex-Modified Concrete by Image Analysis Method

  • Jeong, Won-Kyong;Yun, Kyong-Ku;Hong, Seung-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • 제19권1E호
    • /
    • pp.41-48
    • /
    • 2007
  • Addition of latex to concrete is known to increase its durability and permeability. The purpose of this study is to analyze air void systems in latex-modified concretes using a reasonable and objective method of image analysis with such experimental variables as water-cement (w/c) ratios, latex contents (0%, 15%) and cement types (ordinary portland cement (OPC), high-early strength (HES) cement and very-early strength (VES) cement). The results are analyzed by spacing factor, air volume (content) after hardening, air void distribution and structure. Additionally, air void systems and permeability of latex-modified concrete (LMC) are compared by a correlation analysis. The results are as follows. The LMC of the same w/c ratio showed better air entraining (AE) effect than OPC with AE water reducer. The VES-LMC showed that the quantity of entrained air below $100{\mu}m$ increased more than four times. For the case of HES-LMC, microscopic entrained air between the range of 50 to $500{\mu}m$ increased greater than 7 times even in the absence of anti-foamer. Although spacing factor was measured rather low, the permeability of latex-modified concrete was good. It is construed that air void system does not have a considerable effect on the property of latex-modified concrete, but latex film (membrane) has a definite influence on the durability of LMC.

시멘트 종류에 따른 라텍스개질 콘크리트의 미세공극 구조 분석 (Analysis of Air Void Systems in Latex-Modified Concretes with Cement Types)

  • 윤경구;정원경;김기헌;김경진
    • 한국도로학회논문집
    • /
    • 제7권1호
    • /
    • pp.73-82
    • /
    • 2005
  • 공극구조 분석 방법은 ASTM C 457의 리니어트레버스 포인트카운트법이 있으나, 이러한 방법들은 분석하는데 시간과 노력이 너무 많이 소요되어 현재에는 거의 사용되어지지 않고 있다. 근래에는 현미경과 디지털 카메라, 컴퓨터의 프로그램 발달로 화상분석법이 많은 연구자에 의해 연구되고 있다. 본 연구에서는 화상분석법을 통하여 라텍스개질 콘크리트의 공극 구조 특성을 분석하고자 시멘트 종류(보통포틀랜드시멘트, 초속경시멘트)와 라텍스 혼입율(0,15%)에 따라 실험을 수행하였다. 실험결과, 라텍스는 경화 후 콘크리트에서 AE제의 공기연행효과보다 더 우수한 연행공기 량을 갖는 것으로 나타났다. 또한, 화상분석법을 이용할 경우 경화 후 콘크리트 내부 공극 구조에 대한 다양한 정보를 분석할 수 있을 것으로 판단되었다.

  • PDF

고강도콘크리트의 동결융해저항에 미치는 기포조직의 영향 (Effect of Air Void System of High Strength Concrete on Freezing and Thawing Resistance)

  • 김생빈
    • 콘크리트학회지
    • /
    • 제4권1호
    • /
    • pp.89-96
    • /
    • 1992
  • 콘크리트의 내동해성은 일반적으로 공기량이나 기포조직 및 분포에 따라 크게 영향을 받으며 콘크리트의 강도와도 관련이 있는 것으로 알려져 있다. 본 연구에서는 고강도콘크리트의 동결융해 저항성에 미치는 공기량 및 기포조직 특히 간격계수의 영향에 관한 실험적 연구로서 우선 압축강도는 Non-AE콘크리트를 대상으로 400-500kg/$\textrm{cm}^2$를 목표로 하였고, 실험결과 내구성지수가 10~20%정도에 불과하므로 다음단계로 공기량 2~12%인 AE콘크리트로 하여 내구성 향상을 도모하였다. 이 때 단위시멘트량, 물\ulcorner시멘트비등을 변화시킨 20종류의 콘크리트 배합에 대해 500cycle까지 동결융해시험을 실시하였다. 결론적으로 동결융해의 저항성은 물\ulcorner시멘트비 보다는 공기량과 더 밀접한 관계가 있었고 임계내구성지수에 대응하는 간격계수는 물\ulcorner시멘트비에 따라 다르다는 사실을 알 수 있었다.

경화콘크리트 내부의 기포분포상태 분석에 관한 연구 (Image analysis of an air void system in hardened concrete)

  • 김기철;정재동
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.791-796
    • /
    • 1998
  • Air voids existed in hardened concrete have an important influence on concrete deterioration such as carbonation, freezing and thawing, and corrosion of embedded steel in concrete. Therefore it is very significant to investigate the pore structure of system(size, number and continuity of air voids) to solve the reason caused concrete deterioration. The purpose of this study is to develop the standard method of measuring air voids which affect properties in hardened concrete using image analyzing system. This paper presents the settlement of rapid and exact experimental method which extracts fine bubbles, calculates the number of air voids, and determines air-void distribution using image analyzing system with computer.

  • PDF

Counter-Current Air-Water Flow in Narrow Rectangular Channels With Offset Strip Fins

  • Kim, Byong-Joo;Sohn, Byung-Hu;Koo, Kee-Kahb
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.429-439
    • /
    • 2003
  • Counter-current two-phase flows of air- water in narrow rectangular channels with offset strip fins have been experimentally investigated in a 760 mm long and 100 mm wide test section with 3.0 and 5.0 mm gap widths. The two-phase flow regime, channel-average void fractions and two-phase pressure gradients were studied. Flow regime transition occurred at lower superficial velocities of air than in the channels without fins. In the bubbly and slug flow regimes, elongated bubbles rose along the subchannel formed by fins without lateral movement. The critical void fraction for the bubbly-to-slug transition was about 0.14 for the 3 mm gap channel and 0.2 for the 5 mm gap channel. respectively. Channel-average void fractions in the channels with fins were almost the same as those in the channels without fins. Void fractions increased as the gap width increased, especially at high superficial velocity of air. The presence of fins enhanced the two-phase distribution parameter significantly in the slug flow, where the effect of gap width was almost negligible. Superficial velocity of air dominated the two-phase pressure gradients. Liquid superficial velocity and channel gap width has only a minor effect on the pressure gradients.

공기윤활선 모사 실험에서의 공극률 및 마찰저항저감율 상관성 분석을 위한 실험적 연구 (Experimental study on analysis of correlation between void fraction and drag reduction rate in air lubrication ship)

  • 박승찬;이인원
    • 한국가시화정보학회지
    • /
    • 제18권1호
    • /
    • pp.11-17
    • /
    • 2020
  • The reduction of CO2 emissions has been a key target in the marine industry since the IMO's MEPC published its findings in 2009. Air lubrication method is one of the mature technologies for commercialization to reduce the frictional resistance and enhance fuel efficiency of ships. Since the air lubrication pattern varies according to the ship's standing position and injection flow rate, in order to effectively control the air lubrication system, it is necessary to be able to judge the air layer development state based on the information collected from the monitoring sensor. In this study, we performed the air lubrication ship simulation experiment to measure the void fraction and the frictional resistance. The void fraction was measured to confirm the behavior of the air. Through the measurement of the frictional resistance, the change in frictional resistance reduction rate from the injection point to the longitudinal direction of the ship was confirmed. Based on the measurement results, correlation analysis was performed on void fraction and frictional resistance reduction rate.