• 제목/요약/키워드: air void

검색결과 263건 처리시간 0.036초

요소와 유황을 첨가한 콘크리트의 압축강도와 염화물 확산계수에 대한 공극특성의 영향 (Influence of Air Void Characteristic on Chloride Diffusion Coefficient and Compressive Strength of Concrete using Urea and Sulfur)

  • 김재현;홍기남;전병구
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.75-81
    • /
    • 2016
  • This study presents the effect of urea and sulfur admixture on compressive strength, chloride diffusion coefficient, and internal void distribution of concrete. Compressive strength of concretes with urea admixture by 5% increased by 5% relative to Control. However, that of concretes with urea admixture over 10% decreased. Chloride diffusion coefficient of concrete with urea and sulfur admixture decreased by 40% relative to Control. Additionally, the volume of internal void of concrete with urea and sulfur admixture decreased by 20% relative to Control. Therefore, it can be mentioned from test results that the use of adequate urea and sulfur admixture improves the mechanical properties and durability of concrete.

열간 판재단조시 강괴 내부의 기공폐쇄에 관한 연구 (Study on Internal Void Closure in Slab ingot during Hot Plate Forging)

  • 조종래;김동권;김영득;이부윤
    • 소성∙가공
    • /
    • 제5권1호
    • /
    • pp.18-26
    • /
    • 1996
  • In order to investigate the effect of pre-cooling of ingot on void closure in hot plate forging the internal strain and stress distributions are examined quantitatively by using ABAQUS. Simula-tions are carried out on a large slab ingot having the same temperature and the temperature gradient induced by air-cooling. It is shown that pre-cooling produces little effect on the strain behavior but remarkable effect on the hydrostatic stress at the central zone of ingot. The main factors for crushing micro-voids are the effective strain and the time integral of hydrostatic stress in the region surrounding the voids. Based on regression analysis it was found that the distortion of void can be expressed as a polynomial function of the two factors.

  • PDF

원관내 수직상향 2상유동에서 고분자물질이 유동양식에 미치는 영향 (The Effect of Flow Patterns with Polymer Additivies From Two Phase Flow at Vertical up Ward in Circular Tube)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.505-514
    • /
    • 1998
  • Flow pattern of air-water two phase flow depends on the conditions of pressure void fraction and channel geometry. We classify the flow pattern by measuring the output signal of the conductivity probe. under the classified flow pattern we mount a visualization equipment on the test section and take pictures. We vary the concentration of pure solvent and polymer to measure local void fraction. We know that the maximum point position of local void fraction distribution move from the center of the pipe to the wall of the pipe as JSL increase when JSA is constant in two phase flow. But we find that the maximum point position of local void friction move from the wal of the pipe to the center of the pipe when polymer concentration increase.

  • PDF

광물성 혼화재 혼입 콘크리트의 강도발현 및 공극구조 특성 (Characteristic of Strength Development and Air Void Structure for Concrete mixed with Mineral Admixture)

  • 김성권;서재엽;김진웅;길용수;윤경구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.351-352
    • /
    • 2009
  • 본 연구는 광물성 혼화재를 혼입한 혼합 콘크리트의 역학적 특성을 평가하기 위하여 광물성 혼화재의 종류 및 치환율 그리고 양생온도 및 조건에 따른 공기량, 슬럼프, 공기구조, 정적강도를 측정하였다.

  • PDF

코어 시편을 이용한 열화된 줄눈콘크리트 포장의 공극구조 분석 (Air-void Analysis of Deteriorated Jointed Concrete Pavement Using Concrete Core Specimen)

  • 최판길;정범석;윤경구;권수안
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.253-254
    • /
    • 2009
  • 본 논문은 노후화된 줄눈콘크리트 포장의 열화 원인을 평가하기 위하여 수행되었다. 콘크리트 코어 시편을 사용하여 ASTM C 457 에 의거한 화상분석(Image Analysis)실험을 실시하였다. 정화시편의 공기량, 공극구조분포 및 간격계수(Spacing Factor) 정보를 수집하고 공극구조와 관계한 내구성지수(Durability Factor)를 평가하였다. 평가결과 대부분 시험편의 간격계수가 250$\mu$m 이상으로 평가되어 동결융해에 취약한 것으로 나타났다.

  • PDF

기-액 2상유동에 따른 원심펌프 성능변화에 대한 연구 (A Study on the Performance of a Centrifugal Pump with Two-Phase Flow)

  • 이종철;김윤제;김철수
    • 한국유체기계학회 논문집
    • /
    • 제3권3호
    • /
    • pp.12-18
    • /
    • 2000
  • In this study, experimental and numerical analyses are carried out to investigate the performance of centrifugal pump with various air admitting conditions. Experiments on the pump performance under air-water two-phase flow are accomplished using a centrifugal pump with semi-open type impeller having three, five and seven blades, respectively. Also, the numerical analysis of turbulent air-water two-phase flow using the finite volume method has been carried out to obtain the pressure, velocities and void fraction on the basis of a so-called bubbly flow model with the constant size and shape of cavity. The results obtained through this study show the reasonable agreements within the range of bubbly flow regime. There are promising developments concerning application of the present study for the flow in a centrifugal pump with two-phase flow conditions and efforts must be followed to improve the turbulence model and two-phase flow model for turbomachinery.

  • PDF

원심펌프 기-액 2상유동 특성에 관한 연구 (Flow Characteristics in a Centrifugal Pump with Two-Phase Flow)

  • 이종철;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.568-573
    • /
    • 2000
  • In this study, experimental and numerical analyses are carried out to investigate the performance of centrifugal pump with various air admitting conditions. Experiments on pump performance under air-water two-phase flow n accomplished using a centrifugal pump with semi-open type impeller having three, five and seven blades, respectively. Also, the numerical analysis of turbulent air-water two-phase flow using finite volume method has been carried out to obtain the pressure, velocities and void fraction on the basis of a so-called bubbly flow model with the constant size and shape of cavity. The results obtained through this study show the reasonable agreements within the range of bubbly flow regime. There are promising developments concerning application of the present study for the flow in a centrifugal pump with two-phase flow conditions and efforts must be followed to improve the turbulence model and two-phase flow model for turbomachinery.

  • PDF

A Study on Coolant Mixing in Multirod Bundle Subchannels

  • Cha, Jong-Hee;Cho, Moon-Haeng
    • Nuclear Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.19-25
    • /
    • 1970
  • 이 연구는 다봉속내에서의 인접유로간의 냉각재 혼합류를 실험적으로 다룬 것이다. 실험은 19봉속내의 사각형 유로와 삼각형 유로간의 혼합류를 단상 유동과 공기-물 이상 유동에 물질 전달량을 측정하여 얻고 있다. 실험결과는 단상 유동에서 낮은 혼합률을, 공기-물 이상 유동에서 큰 혼합률을 얻고 있으며 공기-물 유동에서의 혼합률은 공기 체적률의 증가에 따라 감소되고 있음을 나타내고 있다. 공기-물 이상 유동에서의 높은 혼합률은 공기류에 의한 충분한 교란효과 때문인 것 같다.

  • PDF

공랭식 미소유로 응축기의 R410A 충전량 예측에 관한 수치적 연구 (A Numerical Study on R410A Charge Amount in an Air Cooled Mini-Channel Condenser)

  • 박창용
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.710-718
    • /
    • 2010
  • A numerical study was performed to predict refrigerant charge amount in a mini-channel condenser for a R410A residential air-conditioning system. Multi-channel flat tubes with 12 mini-channels of 1.17 mm average hydraulic diameter for each tube were applied to the condenser. The condenser consisted of 3 passes, and the first, second, and third pass had 44, 19, and 11 tubes, respectively. Each pass was connected by a vertical header. In this study, the condenser was divided into 410 finite volumes, and analyzed by an $\varepsilon$-NTU method. With thermophysical properties and void fraction models for each volume element, the R410A amount distribution and a total charge amount in the condenser were calculated. The predicted total charge amount was compared with the experimentally measured charge amount under a standard ARI A condition. The developed model could predict the charge amount in the mini-channel condenser within prediction errors from -23.9% to -3.0%. Air velocity distribution at the condenser face was considered as non-uniform and uniform by the simulation model, and its results showed that the air velocity distribution could significantly influence the charge amount and vapor phase distribution in the condenser.

기포제 혼입 단열형 경량모르타르의 물리적 특성 및 압축강도 추정에 관한 기초적 연구 (Fundamental Study on Estimating Compressive Strength and Physical Characteristic of Heat insulation Lightweight Mortar With Foam Agent)

  • 민태범;우영제;이한승
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.89-96
    • /
    • 2010
  • In comparison with ordinary or heavy-weight concrete, light-weight air void concrete has the good aspects in optimizing super tall structure systems for the process of design considering wind load and seismic load by lightening total dead load of buildings and reducing natural resources used. Light-weight air void concrete has excellent properties of heat and sound insulating due to its high amount porosity of air voids. So, it has been used as partition walls and the floor of Ondol which is the traditional Korean floor heating system. Under the condition of which the supply of light-weight aggregates are limited, the development of light-weight concrete using air voids is highly required in the aspects of reduced manufacturing prices and mass production. In this study, we investigated the physical properties and thermal behaviors of specimens that applied different mixing ratios of foaming agent to evaluate the possibility of use in the structural elements. We proposed the estimating equation for compressive strength of each mix having different ratio of foaming agent. We also confirmed that the density of cement matrix is decreased as the mixing amount of foaming agent increase up to 0.6% of foaming agent mixing ratio which was observed by SEM. Based on porosity and compressive strength of control mortar without foaming agent, we built the estimating equations of compressive strength for mortars with foaming agent. The upper limit of use in foaming agent is about 0.6% of the binder amount. Each air void is independent, and size of voids range from 50 to $100{\mu}m$.