• Title/Summary/Keyword: air ventilation rate

Search Result 378, Processing Time 0.028 seconds

Evaluation of the Farmers' Workload and Thermal Environments during Chili Harvest in the Open Field (여름철 노지 고추 수확 작업시 고령농업인의 온열 부담 평가)

  • Chae, Hyeseon;Kim, Hyunjin;Oh, Youngsoon;Lee, Kyungsuk;Kim, Hyocher;Kim, Kyungran
    • The Korean Journal of Community Living Science
    • /
    • v.24 no.4
    • /
    • pp.543-552
    • /
    • 2013
  • Physiological and subjective responses of the farmers and thermal environment during chili harvest in the open field were investigated to evaluate the thermal environments and farmers's workload. Eight career female farmers in their sixties participated as subjects both in morning work(MW, AM 9:00~10:30) and in afternoon work(AW, PM 15:00~16:30) with each lasting about 90 minutes. The results were as follows. 1) Air temperature, air humidity, globe temperature and WBGT of MW were mean $25.54^{\circ}C$, 81.82%RH, $37.72^{\circ}C$, $26.27^{\circ}C$ and AW were mean $30.63^{\circ}C$ 82.50%RH, $40.11^{\circ}C$, $30.02^{\circ}C$, respectively. By the WBGT, we evaluated that the thermal environment in the afternoon in the open field gave a thermal burden to farmers. 2) Mean skin temperature of AW($34.8{\pm}0.8^{\circ}C$) was higher than MW($33.5{\pm}1.2^{\circ}C$)(p<0.05). Clothing microclimate temperature on the chest of each work time were $31.3^{\circ}C$(MW) and $32.7^{\circ}C$(AW). Clothing microclimate humidity on the chest of each work time were over 80%RH. Heart rate were 88.5bpm(MW) and 91.7bpm(AW) respectively. 3) Farmers working in the afternoon felt uncomfortable after 45~60 min. of work and in the morning they felt uncomfortable after 90 min. of work. We evaluated that the harvesting of chilies in the open field was 'moderate work' by the physiological responses but the level of thermal burden increased over time especially in the afternoon work. It is suggested that farm workers should drink fluids between work to stay in homeostasis by sweating and to take frequent rests. Active clothing ventilation and wearing functional garments would help farm workers excrete sweat effectively.

Properties of Harmful Substances Absorption Eco-friendly Artificial Stone Containing Basalt Waste Rock (현무암 폐석을 첨가한 유해물질 흡착 친환경 인조석재의 특성)

  • Pyeon, Su-Jeong;Gwon, Oh-Han;Kim, Tae-Hyun;Lee, Sang-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.431-438
    • /
    • 2016
  • Recently, Both rapid economic growth and high-quality native finishing materials demand in buildings such as local infrastructure facilities and cultural facilities have increased along with local quarries. So, increasing local quarries and environmental pollution occurred in quarries get the eyes to damaged area of the surroundings. As an example, carcinogen such as solid formed to fixing asbestos and dust have damaged to local resident. Especially, Radon gas released from asbestos can exist everywhere on earth, released soil and rock as radioactive substances, can be caused lung cancer followed by a smoking. When pollution source to indoor air quality that lacking ventilation rate of the residential building moved in a cycle, human responses such as headache, dizziness, etc. get appear, so on it threatened resident's physical condition. Thus, we need to urgent attention to reduction harmful substance. In the case of radon gas of the pollution source to indoor air quality in housing, it has characteristic that keep on going through half-life released from source, we need to control radon gas source than source removal. We set on vermiculite addition ratio to 10% which has harmful substances adsorption performance, proceed experiment to basalt waste rock addition ratio 50, 60, 70, 80(%). The result of an experiment, based on 'KS F 4035, precast terrazzo', we can be obtainable in the best terrazzo at basalt waste rock addition ratio 70%.

Comparison of Ventilation Efficiency in an Enclosed and Conventional Growing-Finishing Pig House (개방형과 무창형 육성비육돈사의 환기효율 비교)

  • Song, J.I.;Choi, D.Y.;Jung, J.W.;Yang, C.B.;Choi, H.L.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.459-468
    • /
    • 2004
  • An experiment was conducted to establish comparison of ventulation efficiency in an enclosed and conventional growing-finishing pig house. The main results of the experiment are as follows : In the established temperature was sustained at the level of summer 24.8${\sim}$29.1$^{\circ}C$, winter 17.9${\sim}$23.1$^{\circ}C$ during the experimental period of enclosed growing-finishing pig house, and conventional growing-finishing pig house was at the lovel of summer 24.7${\sim}$32.3$^{\circ}C$, winter 14.5${\sim}$18.2$^{\circ}C$ during the experimental period respectively. As for the results of dertimental gas(ammonia) concentration ratio analysis, while the conventional pig house sustained of summer 9.3${\sim}$16.9 mg/$\ell$ level, enclosed growing-finishing pig house sustained of summer 7.9${\sim}$16.1 mg/$\ell$, and the latter one is lower than that of the conventional growing-finishing pig house. Air flow rate on the floor level which is the low part of pen and the active area of pigs in the enclosed growing and finishing pig house during winter was measured at 0 to 0.87 m/s at the 0.01 to 2.73 m/s at the maximum ventilation efficiency. As for breeding pigs in summer, the pigs from the conventional pig house weighed 100.2kg, on the other hand, the pigs from enclosed growing-finishing pig house weighed 107.3 kg ; the differnce between the two kinds was about 7 kg. This was because the most adequate environment, which was not influenced by the exterior atmosphere, was offered to the pigs from enclosed growing-finishing pig house, and all of this could reduce pigs stress effectively.

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

The Relationships between Allergy and Weakness in Children in Seong-Dong District (성동구내 어린이집 어린이의 알레르기 질환과 허약아의 실태 및 관련성에 대한 보고)

  • Park, You-Jin;Yoon, Ji-Yeon;Myoung, Sung-Min
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.24 no.2
    • /
    • pp.112-125
    • /
    • 2010
  • Objectives The purpose of this study is to find the relationships between the allergy and weakness in children in Seong-Dong district. Methods 802 day care centers children were participated for survey on allergic disease, risk factors, and weakness. From the result, we analyzed the relationships between the aforementioned factors. Results 1. 802 children were participated for the survey. We eliminated survey answers with unclear answers, and selected 792 survey sheets as our final subject of study. The age of majority of subjects(720 children) were between one to six years old, and the others were under the age of one and over seven. 2. The prevalence rate of asthma in a lifetime was 6.69%, allergic rhinitis was 14.87%, atopic dermatitis was 28.82%, allergic conjunctivitis was 6.29%, food allergies was 9.58%, and drug allergies was 1.4%. In 2009, the prevalence rate of allergies during treatments is 6.69% for asthma, 13.41% for allergic rhinitis, 13.64% for atopic dermatitis, 4.13% for allergic conjunctivitis, 5.23% for food allergies, 0.96% for drug allergies. 3. The significant risk factors were types of dwelling, pet with fur, dirty environments without vacuum cleaners, the numbers of times bed covers were washed, frequency of air ventilation, changes in body after moving, family history. 4. The distribution of the number of children with weakness within the five visceras were respiratory weakness, digestive weakness, psychoneurologic weakness, neuromotor weakness, and urogenital weakness in the order of most to the least. More specifically, children who only has respiratory weakness were the majority, while children who have respiratory and digestive weaknesses, children who have respiratory, digestive, and psychoneurologic weaknesses, children who have respiratory and psychoneurologic were followed. 5. With the exception of children with urogenital weakness, Most of the children with respiratory weakness, digestive weakness, psychoneurologic weakness, and neuromotor weakness had been treated for allergies in 2009, while children who were diagnosed with allergic diseases at least once in their lifetime most likely had weak respiratory, digestive or psychoneurologic systems. Conclusions The results of this study showed that there was a correlation between children with weak viscera and children with allergic diseases. However, further research would be necessary.

Effects of Combination of Air Temperature and Soil Moisture Contents on Growth, Clove Initiation, Physiological Disorders, and Yield of Garlic (기온과 토양수분 함량에 따른 난지형 마늘의 생장, 인편분화, 생리장해 및 수량에 미치는 영향)

  • Lee, Hee Ju;Lee, Sang Gyu;Kim, Sung Kyeom;Mun, Boheum;Lee, Jin Hyoung;Lee, Hee Su;Kwon, Young Seok;Han, Ji Won;Kim, Cheol Woo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.191-198
    • /
    • 2018
  • The objective of this study was to determine the effects of combination of air temperature and soil water contents on growth, physiological disorder rate, and yield of garlic. This experiments has been carried out in the typical plastic house (one side open and other side installed ventilation fans) which was maintained gradient air temperature (maximum different value of air temperature : $6^{\circ}C$). The excessive irrigation (EI) set at $0.34m^3/m^3$ soil moisture contents. The significant differences found in the growth parameters of garlics as affected by air temperature and soil moisture conditions. The plant height of garlic with combination of ambient $(A)+6^{\circ}C$ and optimal irrigation (OI; set at $0.22m^3/m^3$ soil moisture contents) treatments represented 47.4 cm/plant, which was the highest among all the tested treatments. The leaf length and width showed the greatest, which were 16.1 and 2.4 cm/plant, respectively, in $A+6^{\circ}C-OI$. The physiological disorder ratio was higher as 12.9% at $A+6^{\circ}C-OI$ and was not occurred at ambient temperature with EI compared with OI treatment. The bulb and clove weight were dramatically decreased at $A+6^{\circ}C$ temperature treatment. The yields were decreased by 51% in OI at $A+6^{\circ}C$ and $A+3^{\circ}C$ temperature treatment. Those results indicated that yields were decreased and ratio of physiological disorders was increased by high temperature treatments.

Effect of Modified Cyclone Dust Collector in Windowless Broiler Building (변형된 사이클론 먼지포집기의 이용이 무창계사의 먼지농도에 미치는 영향)

  • Choi, H.C.;Yeong, G.Y.;Song, J.I.;Kang, H.S.;Kwon, D.J.;Yoo, Y.H.;Yang, C.B.;Chun, S.S.;Kim, Y.K.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.97-104
    • /
    • 2007
  • This study was carried out to develop the modified cyclone dust collector in windowless broiler building measuring 12 m wide, 46 m long, with a side wall height of 3 m and a capacity of 12,800 birds. Ventilation rate in windowless broiler building was $0.014{\sim}0.015\;and\;0.158{\sim}0.181cmm$ in second weeks and fifth weeks of age, respectively. Ammonia concentration was $13{\sim}16\;and\;20{\sim}24\;ppm$ in first and second weeks of age, respectively. Amount of dust collected in dust collector each week was 104.1, 274.7 and 388.6g in first, second and third weeks of age. But it was decreased from fourth weeks of age because of the increased ventilation rate. Total suspended particulate(TSP) of polluted air was $3,111.7{\sim}8,745.2{\mu}g/m^3$, but it was decreased to $530.8{\sim}2,264.4{\mu}g/m^3$ when it passed through the dust collector. Collecting efficiency was $54.2{\sim}82.9%$ in TSP. But collecting efficiency of Particulate matter smaller than $1{\mu}g$ (PM1.0) was $7.6{\sim}33.8%$, and lower than TSP. TSP concentration in control broiler house was 1,387.6 and $4,210.1{\mu}g/m^3$ in first and fourth weeks of age, respectively. But it was decreased to 876.3 and $2,535.3{\mu}g/m^3$ in broiler house operated dust collector in first and fourth weeks of age, respectively. Dust collecting efficiency for TSP was $36.8{\sim}39.8%$, and it was decreased to $11.4{\sim}39.8%$ in smaller dust size.

  • PDF

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.

Initial Risk Assessment of Acetanilide in OECD High Production Volume Chemical Program

  • Park, Hye-Youn;Park, Yoonho;Sanghwan Song;Kwon, Min-Jeoung;Koo, Hyun-Ju;Jeon, Seong-Hwan;Na, Jin-Gyun;Park, Kwangsik
    • Toxicological Research
    • /
    • v.18 no.1
    • /
    • pp.13-22
    • /
    • 2002
  • In Korea, 2,320 tonnes of acetanilide were mostly wed as intermediates for synthesis in phar-maceuticals or additives in synthesizing hydrogen peroxide, varnishes, polymers and rubber. Only small amount of 120 kg were wed as a stabilizer for hydrogen peroxide solution for hair colouring agents in 1998. Readily available environmental or human exposure data do not exist in Korea at the present time. However, potential human exposures from drinking water, food, ambient water and in work places are expected to be negligible because this chemical is produced in the closed system in only one company in Korea and the processing factory is equipped with local ventilation and air filtering system. Acetanilide could be distributed mainly to water based on EQC model. This substance is readily biodegradable and its bioaccumulation is low. Acute toxicity of acetanilide is low since the L $D_{50}$ of oral exposure in rats is 1,959 mg/kg bw. The chemical is not irritating to skin, but slightly irritating to the eyes of rabbits. horn repeated dose toxicity, the adverse effects in rats were red pulp hyperplasia of spleen, bone marrow hyperplasia of femur and decreased hemoglobin, hematocrit and mean corpuscular hemoglobin concentration. The LOAEL for repeated dose toxicity in rats was 22 mg/kg/day for both sexes. Acetanilide is not considered to be genotoxic. In a reproductive/developmental toxicity study, no treatment-related changes in precoital time and rate of copulation, impregnation, pregnancy were shown in all treated groups. The NOAELs for reproduction and developmental toxicity (off-spring toxicity) are considered to be 200 mg/kg bw/day and 67 mg/kg bw/day, respectively. Ecotoxicity data has been generated in a limited number of aquatic species of algae (72 hr- $E_{b}$ $C_{50}$; 13.5 mg/l), daphnid (48hr-E $C_{50}$ > 100 mg/l) and fish (Oryzias latipes, 96hr-L $C_{50}$; 100 mg/l). Form the acute toxicity values, the predicted no effect concentration (PNEC) of 0.135 mg/1 was derived win an assessment factor of 100. On the basis of these data, acetanilide was suggested as currently of low priority for further post-SIDS work in OECD.in OECD.D.

Analysis of Hygrothermal Performance for Standard Wood-frame Structures in Korea (국내 농어촌 표준 목조주택의 hygrothermal 성능 분석)

  • Chang, Seong Jin;Kang, Yujin;Wi, Seunghwan;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.440-448
    • /
    • 2016
  • As recent buildings become more air tight, the natural ventilation rate is significantly reduced and it leads to difficulty in removing accumulated moisture in buildings. Hot and humid weather in summer and the large amount of moisture caused by indoor activity are the major factors of moisture problem in Korea. The hygrothermal behavior of building environment has to be considered carefully to reduce condensation risk and mold growth potential, and comfortable indoor environment. In this study, we evaluated hygrothermal behavior of Standard Wood-frame Structure published in the Korea Rural Community Corporation Using WUFI simulation program. The results indicated that the total water contents of wood wall measured in 2014 was lower than wood wall in 2010. As a result of evaluation by separating the farming and fishing areas, Moisture problems in fishing area became larger. The walls had a significant impact on the relative humidity than the temperature each areas. Furthermore, excessive water content problem of the wood-based material was reduced in the wall that could be applied in the fishing villages by changing the outdoor finishing materials. And Mold growth risk on the interior materials could be removed through the different setting of the indoor temperature during summertime.