• Title/Summary/Keyword: air quality monitoring

Search Result 454, Processing Time 0.031 seconds

Fate Analysis and Impact Assessment for Vehicle Polycyclic Aromatic Hydrocarbons (PAHs) Emitted from Metropolitan City Using Multimedia Fugacity Model (다매체거동모델을 이용한 대도시 자동차 배출 Polycyclic Aromatic Hydrocarbons (PAHs) 거동 해석 및 영향평가)

  • Rhee, Gahee;Hwangbo, Soonho;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.479-495
    • /
    • 2018
  • This study was carried out to research the multimedia fate modeling, concentration distribution and impact assessment of polycyclic aromatic hydrocarbons (PAHs) emitted from automobiles, which are known as carcinogenic and mutation chemicals. The amount of emissions of PAHs was determined based on the census data of automobiles at a target S-city and emission factors of PAHs, where multimedia fugacity modeling was conducted by the restriction of PAHs transfer between air-soil at the impervious area. PAHs' Concentrations and their distributions at several environmental media were predicted by multimedia fugacity model (level III). The residual amounts and the distributions of PAHs through mass transfer of PAHs between environment media were used to assess the health risk of PAHs at unsteady state (level IV), where the sensitivity analyses of the model parameter of each variable were conducted based on Monte Carlo simulation. The experimental result at S-city showed that Fluoranthene among PAHs substances are the highest residual concentrations (60%, 53%, 32% and 34%) at all mediums (atmospheric, water, soil, sediment), respectively, where most of the PAHs were highly accumulated in the sediment media (more than 80%). A result of PAHs concentration changes in S-city over the past 34 years identified that PAHs emissions from all environmental media increased from 1983 to 2005 and decreased until 2016, where the emission of heavy-duty vehicle including truck revealed the largest contribution to the automotive emissions of PAHs at all environment media. The PAHs concentrations in soil and water for the last 34 years showed the less value than the legal standards of PAHs, but the PAHs in air exceeded the air quality standards from 1996 to 2016. The result of this study is expected to contribute the effective management and monitoring of toxic chemicals of PAHs at various environment media of Metropolitan city.

Characteristics of PM2.5 and PM10 Concentration in Pusan Area (부산지역 PM2.5와 PM10의 농도 특성)

  • Kim, Sang-Youl;Cheong, Jang-Pyo;Yi, Seung-Muk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1159-1170
    • /
    • 2000
  • It is necessary to improve the ambient air quality through the proper treatment and control of pollutants by designating air pollutants to regulatory ones. Especially, human took a concern for particulate matters which raised visibility reduction, public health effects and injury of property for urban areas. In order to reduce the effect of particulate matters, we need to establish proper control strategies based on the concentration characteristics of particulate matters. In this study. to evaluate the characteristics of $PM_{2.5}$ and $PM_{10}$. thirty-eight samples of $PM_{2.5}$ and $PM_{10}$ were collected at Nam-Gu sampling site where continuous air monitoring system has been operated, from May, 1999 to November, 1999, and their concentrations for the mass and anion components($Cl^-$, $NO_3{^-}$, $SO_4{^{2-}}$) were analyzed. The important conclusions obtained in this study were as followings. Total average mass concentrations of $PM_{2.5}$ and $PM_{10}$ were 35.016 and $50.293{\mu}g/m^3$ respectively. and $PM_{2.5}/PM_{10}$ ratio was calculated 0.692. Total average concentrations of anion components in $PM_{2.5}$ were $1.581(Cl^-)$, $3.690(NO_3{^-})$ and $12.825(SO_4{^{2-}}){\mu}g/m^3$ and those in $PM_{10}$ were $2.471(Cl^-)$, $5.819(NO_3{^-})$ and $14.414(SO_4{^{2-}}){\mu}g/m^3$ respectively. From the correlations analysis. the correlation coefficient between mass concentration of $PM_{2.5}$ and $PM_{10}$ was calculated as 0.945. The correlation coefficients between $PM_{2.5}$ and anion components were analyzed as $Cl^-$(0.025), $NO_3{^-}$(0.788) and $SO_4{^{2-}}$(0.500) respectively, and the correlation coefficients between $PM_{10}$ and anion components were analyzed as $Cl^-$(-0.019), $NO_3{^-}$(0.806) and $SO_4{^{2-}}$)(0.535) respectively.

  • PDF

Improvement of Nutrient Balance using Feed Crops for Regional Nutrient Management (지역 양분관리를 위한 조사료 단지의 양분수지 개선효과)

  • Yang, Heon-yong;Kim, Jung-Gyun;Oh, Byung Wook;Seo, Il-hwan
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.89-95
    • /
    • 2020
  • Livestock facilities in Korea are on their way of enlargement resulting in increment of livestock manure. When the livestock manure treated inappropriate way during application to the agricultural area, environmental damage can be occurred such as bad smell, water and air pollution. Therefore it is important to make a good management plan for livestock manure treatment. In order to effectively apply organic fertilizer made by livestock manure in terms of quantity and quality, the current status of nutrient in agricultural land should be calculated quantitatively by scientific way. The OECD suggest member countries to calculate the nutrient balance as an agricultural environment indicator which represents the difference between nutrient inputs and outputs of the amount of nutrients in various ways. In this paper, we calculated the nutrient balances according to three cities which have different characteristics such as urban or rural areas. To reduce the nutrient balance, we considered how to reduce the amount of chemical fertilizer by using organic fertilizer made by livestock manure. And public treatment facilities for livestock manure can be a good solution except civil complaints for location selection. Among the options, manure fertilizer application to the agricultural area for cultivation of forage crops was mainly considered to reduce the nutrient balance by decreasing input of chemical fertilizers and increasing output of crop production. Using the field monitoring data, it can be calculated that the daily nitrogen reductions by 116.5 kg/ha and the daily phosphorus increments by 2.7 kg/ha.

Evaluation on Air Quality inside Subway Driver Cabin by Monitoring PM, $CO_2$, and CO Levels (서울 일부 지하철 승무원석의 PM, 이산화탄소, 일산화탄소 모니터링에 의한 실내 공기질 특성 평가)

  • Kwag, Hyun-Suk;Jin, Ku-Won;Kim, Won;Yang, Won-Su;Choi, Sang-Jun;Park, Dong-Uk
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.379-386
    • /
    • 2005
  • [ $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ ] in driver cabins of subway line from 5 to 8 were monitored from 07:00 through 21:00 (or 19:30 or 20:00) on May. Driver cabin of subway line 7 showed the highest $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ concentrations. General Linear Model indicated that subway line, subway location (ground and underground track) and running time (morning and afternoon) significantly influenced the concentrations of $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ (p=0.000). Daily profile of $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$, expressed as an 30 minutes average, showed similar variation pattern over day period. These concentrations showed the highest concentrations between 07:00 and 09:00 of rush hour, slightly dropped and again rose slightly after 18:00. In correlation analysis, significant relations among $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ were detected (p<0.01). In particular, correlation coefficient between $PM_{10}\;and\;PM_{2.5}$ was highly significant (r=0.884). Regression analysis also concluded that $PM_{10}$ concentration significantly explained 71.4% of variation of $PM_{2.5}$ concentration (p=0.000, $R^2=0.714$). Correlations by CO with $PM_{10}\;and\;PM_{2.5}$ were 0.451 and 0.520, which were higher than those by $CO_2$. Further study is needed to examine the sources of $PM_{2.5}$ and CO in subway and to compare pollutants concentration among subway lines.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

Potential Source of PM10, PM2.5, and OC and EC in Seoul During Spring 2016 (2016년 봄철 서울의 PM10, PM2.5 및 OC와 EC 배출원 기여도 추정)

  • Ham, Jeeyoung;Lee, Hae Jung;Cha, Joo Wan;Ryoo, Sang-Boom
    • Atmosphere
    • /
    • v.27 no.1
    • /
    • pp.41-54
    • /
    • 2017
  • Organic carbon (OC) and elemental carbon (EC) in $PM_{2.5}$ were measured using Sunset OC/EC Field Analyzer at Seoul Hwangsa Monitoring Center from March to April, 2016. The mean concentrations of OC and EC during the entire period were $4.4{\pm}2.0{\mu}gC\;m^{-3}$ and $1.4{\pm}0.6{\mu}gC\;m^{-3}$, respectively. OC/EC ratio was $3.4{\pm}1.0$. The average concentrations of $PM_{10}$ and $PM_{2.5}$ were $57.4{\pm}25.9$ and $39.7{\pm}19.8{\mu}g\;m^{-3}$, respectively, which were detected by an optical particle counter. The OC and EC peaks were observed in the morning, which were impacted by vehicle emission, however, their diurnal variations were not noticeable. This is determined to be contributed by the long-range transported OC or secondary formation via photochemical reaction by volatile organic compounds at afternoon. A conditional probability function (CPF) model was used to identify the local source of pollution. High concentrations of $PM_{10}$ and $PM_{2.5}$ were observed from the westerly wind, regardless of wind speed. When wind velocity was high, a mixing plume of dust and pollution during long-range transport from China in spring was observed. In contrast, pollution in low wind velocity was from local source, regardless of direction. To know the effect of long-range transport on pollution, a concentration weighted trajectory (CWT) model was analyzed based on a potential source contribution function (PSCF) model in which 75 percentiles high concentration was picked out for CWT analysis. $PM_{10}$, $PM_{2.5}$, OC, and EC were dominantly contributed from China in spring, and EC results were similar in both PSCF and CWT. In conclusion, Seoul air quality in spring was mainly affected by a mixture of local pollution and anthropogenic pollutants originated in China than the Asian dust.

Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds (강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석)

  • Kwon, Kyeong Seok;Jo, Ye Seul;Lee, In Bok;Ha, Tae Hwan;Hong, Se Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.31-43
    • /
    • 2014
  • Confined and mechanically ventilated broiler house has been recently come into wide use to increase productivity and control rearing conditions. However, high dust concentration inside facility can threaten respiratory welfare of farmers and broilers. In Korea, there is no regulation in terms of air quality control inside agricultural facilities and sufficient data is not available. To cope with these, periodic monitoring of inhalable and respirable dust concentration were conducted according to season, broiler's activity and specific events such as shipment work for broilers in mechanically ventilated broiler house. Chamber experiment was also designed to analyze mechanism of dust generation from ground beds according to water contents and surrounding wind environment. Results showed that significant increase of inhalable (p=0.002) and respirable (p=0.03) dust were observed when activity of broilers was high according to entrance of the workers. Even shipment work for matured broilers, high level of dust were observed; inhalable dust was exceeded the threshold limit over maximum 303 % and respirable dust was over maximum 1,550 %, implying that acute respiratory symptoms could be manifested for the workers. From the chamber experiment, critical water contents for interrupting of dust generation were measured; about 45 % for inhalable dust and about 50 % for respirable dust. These results can be a trigger for designing plan of dust control however it still needs consideration of various environmental conditions, hygiene problems, etc.

A Study on Smart Factory System Design for Screw Machining Management (나사 가공 관리를 위한 스마트팩토리 시스템 설계에 관한 연구)

  • Lee, Eun-Kyu;Kim, Dong-Wan;Lee, Sang-Wan;Kim, Jae-joong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.329-331
    • /
    • 2018
  • In this paper, we propose a monitoring system that starts with the supply of raw materials for threading, is processed into a lathe machine, and checks for defects of the product are automatically performed by the robot with Smart Factory technology through assembly and disassembly. Completion check according to the production instruction quantity and production instruction is made by checking the production status according to whether or not the raw material is worn by the displacement sensor, and checking the pitch and the contour of the processed female and male to determine OK and NG. The robotic system acts as a relay for loading and unloading of raw materials, pallet transfer, and overall process, and it acts as an intermediary for organically driving. The location information of the threaded products is collected by using the non-contact wireless tag and the energy saving system Production efficiency and utilization rate were checked. The environmental sensor collects the air-conditioning environment data (temperature, humidity), measures the temperature and humidity accurately, and checks the quality of product processing. It monitors and monitors the driving hazard level environment (overheating, humidity) of the product. Controls for CNC and robot module PLC as a heterogeneous system.

  • PDF

Meteorological Characteristics of High-Ozone Episode Days in Daegu, Korea (대구시의 고농도 오존 발생 일에 나타나는 기상학적 특성)

  • Son, Im-Young;Kim, Hee-Jong;Yoon, Ill-Hee
    • Journal of the Korean earth science society
    • /
    • v.23 no.5
    • /
    • pp.424-435
    • /
    • 2002
  • This study analyzes the surface ozone and meteorological data in Daegu for a period from 1997 to 1999. It also investigates the meteorological characteristics of high ozone episodes. For this study the high ozone episode has been defined as a daily maximum ozone concentration higher than 100ppb in at least one station among six air quality monitoring stations in Daegu, Korea. The frequency of episodes is 13 days. The frequency is the highest in May and September. The average value of daily maximum ozone concentration is 81.6ppb, and 8-hour average ozone concentration is 58.6ppb for the high episodes. This shows that ozone pollution is continuous and wide-ranging in Daegu. The daily maximum ozone concentration is positively correlated to solar radiation and daily maximum temperature, but negatively correlated to relative humidity, wind speed and cloud amount. The maximal correlation coefficient to solar radiation is 0.45. The differences between high ozone episode day's daily mean meteorological value and monthly mean value are +1.58hPa for sea level pressure, +3.45${\circ}$C for maximum temperature, -5.69% for relative humidity, -0.46ms$^{-1}$ for wind speed, -1.79 for cloud amount, and +3.97MJm$^{-2}$ for solar radiation, respectively. This shows that strong solar radiation, low wind speed and no precipitation between 0700${\sim}$1100LST are favorite conditions for high ozone episodes. It is related to the morning stagnant condition.

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.