• Title/Summary/Keyword: air mass

Search Result 2,615, Processing Time 0.027 seconds

Understory Evapotranspiration Measured by Eddy-Covariance in Gwangneung Deciduous and Coniferous Forests (광릉 활엽수림과 침엽수림에서 에디공분산으로 관측한 하부 군락의 증발산)

  • Kang, Min-Seok;Kwon, Hyo-Jung;Lim, Jong-Hwan;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.233-246
    • /
    • 2009
  • The partitioning of evapotranspiration (ET) into evaporation (E) and transpiration (T) is critical in understanding the water cycle and the couplings between the cycles of energy, water, and carbon. In forests, the total ET measured above the canopy consists of T from both overstory and understory vegetation, and E from soil and the intercepted precipitation. To quantify their relative contributions, we have measured ET from the floors of deciduous and coniferous forests in Gwangneung using eddy covariance technique from 1 June 2008 to 31 May 2009. Due to smaller eddies that contribute to turbulent transfer near the ground, we performed a spectrum analysis and found that the errors associated with sensor separation were <10%. The annual sum of the understory ET was 59 mm (16% of total ET) in the deciduous forest and 43 mm (~7%) in the coniferous forest. Overall, the understory ET was not negligible except during the summer season when the plant area index was near its maximum. In both forest canopies, the decoupling factor ($\Omega$) was about ~0.15, indicating that the understory ET was controlled mainly by vapor pressure deficit and soil moisture content. The differences in the understory ET between the two forest canopies were due to different environmental conditions within the canopies, particularly the contrasting air humidity and soil water content. The non-negligible understory ET in the Gwangneung forests suggests that the dual source or multi-level models are required for the interpretation and modeling of surface exchange of mass and energy in these forests.

Formation of MOCVD TiN from a New Precursor (새로운 증착원으로 형성된 MOCVD TiN에 관한 연구)

  • Choe, Jeong-Hwan;Lee, Jae-Gap;Kim, Ji-Yong;Lee, Eun-Gu;Hong, Hae-Nam;Sin, Hyeon-Guk
    • Korean Journal of Materials Research
    • /
    • v.9 no.3
    • /
    • pp.244-250
    • /
    • 1999
  • MOCVD TiN films were prepared from a new TiN precursor, tetrakis(etylmethylamino)titanium (TEMAT) and ammonia. Deposition of TiN films from a single precursor, TEMA T yielded the growth rates of $70 to 1050\AA$/min, depending on the deposition temperature. Furthermore, the excellent bottom coverage of -90% over $0.35\mu\textrm{m}$ contacts was obtained at $275^{\circ}C$. The addition of ammonia to TEMA T lowered the resistivity of as- deposited TiN film to ~ $800\mu\omega-cm$ from $3500~6000\mu\omega-cm$ and improved the stability of TiN film in air. Examination of the films by Auger electron spectroscopy(AES) showed that the oxygen and carbon contents decreased with the addition of ammonia. However, increasing ammonia flow rate decreased the bottom coverage of TiN films over $0.5\mu\textrm{m}$ contacts, probably due to the high sticking coefficient of intermediate species produced from the gas phase reaction of TEMA T and ammonia. Based on the byproduct gases detected by the quadrupole mass spectrometer (QMS), the transammination reaction was proposed to be responsible for TiN deposition. In addition, XPS analysis revealed that the carbon in the films made from TEMA T and ammonia was metallic carbon, suggesting that $\beta$-hydrogen activation process occurs competitively with the transammination reaction.

  • PDF

Spawning Behavior and Development of Eggs and Larvae of the Korea Freshwater Goby, Rhinogobius brunneus (Gobiidae: Perciformes) (한국산 밀어 (Rhinogobius brunneus)의 산란습성, 난발생 및 자어의 형태발달)

  • HAN Kyeong-Ho;KIM Yong Uk;CHOE Kyu-Jung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.1
    • /
    • pp.114-120
    • /
    • 1998
  • The spawning behavior, development of eggs and larvae of the Korea freshwater goby, Rhinogobius brunneus (Temminck et Schlegel) were studied. The eggs were spawned as a one-layer mass, hanging from the underside of a small pebble, and guarded by one male. The eggs were elliptic, about 1.48 mm in length and 0.65 mm in breadth, with a round top and a somewhat flat base with glutinous fibers. Hatching in the indoor tank with $17.0^{\circ}C$ in mean water temperature started from the 146 hours after fertilization. In the late developing stages, the embryo moved and freely changed its head to face the free tip of the chorion (normal egg) or to the basal end with a boundle of adhesive filaments (agrippa egg). Newly-hatched larvae were $3.10\~3.30$ mm in total length (mean: 3.22 mm), and mouth and anus were not yet open. Melanophores were present on the air- bladder, around the anus, and on the ventral part of the caudal region. The larva $3\~4$ days old transformed to postlarval stage, and they were $3.30\~3.85$ mm in total length (mean: 3.60 mm). As yolk sac and oil globules werw nearly absorbed, mouth and anus were open, and they fed rotifers actively. In $20\~22$ days after hatching the larvae grew to 5.85 mm in 71, and the caudal notochord flex at $45^{\circ}$.

  • PDF

GEMS BrO Retrieval Sensitivity Test Using a Radiative Transfer Model (복사전달모델을 이용한 GEMS 일산화브로민 산출 민감도 시험)

  • Chong, Heesung;Kim, Jhoon;Jeong, Ukkyo;Park, Sang Seo;Hong, Jaemin;Ahn, Dha Hyun;Cha, Hyeji;Lee, Won-Jin;Lee, Hae-jung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1491-1506
    • /
    • 2021
  • To estimate errors in GEMS retrievals for bromine monoxide (BrO) total vertical column densities(VCDs), we perform a sensitivity test using synthetic spectra generated by a radiative transfer model. Hourly synthetic data are produced for 00-07 UTC on the first day of every month in Jul 2013- Jun 2014. Solution errors estimated by the optimal estimation method tend to decrease with increasing air mass factors (AMFs) but increase when AMFs are larger than 5. Interference errors induced by formaldehyde (HCHO) absorption appear to be larger with smaller BrO AMFs. Total BrO retrieval errors estimated by combining solution and interference errors show an average of 26.74±30.18% for all data samples and 60.39±133.78% for those with solar zenith angles higher than 80°. Due to interfering spectral features and measurement errors not considered in thisstudy, errorsin BrO retrievals from actual GEMS measurements may have different magnitudes from our estimates. However, the variability of errors assessed in this study is still expected to appear in the actual BrO retrievals.

Numerical Study on Performance of PEMFC with Block and Sub-channel of Cathode Flow Field (캐소드 유로에서 블록과 서브 채널의 고분자전해질 연료전지의 성능에 관한 전산해석 연구)

  • Jo, Seonghun;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.613-620
    • /
    • 2021
  • A flow channel shape of PEMFC has an influence on the internal flow uniformity. If the reactant distribution in a flow path is not uniform during operation, both catalyst deactivation and mechanical damage of membrane could occur resulting in decreasing the membrane electrode assembly (MEA) durability. Numerous studies concerning flow design have been conducted to make smooth supply and uniform distribution of reactants in fuel cells. The baffle of flow path could improve fuel cell performance through the forced convection effect. A sub-channel, as an additional air flow path, could increase the reactant concentration and reduce the mass transfer loss via a smooth water discharge. In this study, computational fluid dynamics (CFD) was used to analyze the effect of blocks and sub-channels on the current density and oxygen concentration of the fuel cell. As a result, the limit current density and oxygen concentration at a rear block increased when using blocks and sub-channels in a flow channel. In particular, the current density increased significantly when the sub-channel was placed between two blocks. Also, the sub-channel position was optimized by analyzing the oxygen concentration, and the oxygen concentration was recovered at a rear block in the fuel cell.

Emergency preoperative angioembolization without computed tomography to treat unstable pelvic fractures with bowel perforation (장 천공을 동반한 혈역학적으로 불안정한 골반골 골절에서 전산화 단층촬영 전 시행한 혈관색전술의 지혈효과: 증례보고)

  • Park, Chan-Yong;Kang, Wu-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.417-422
    • /
    • 2019
  • Hemodynamically unstable pelvic fractures show a remarkably high mortality rate of 40% to 60%. However, their standard of care remains controversial. We report here a case of a 78-year-old woman who was admitted to the Emergency Department with pelvic pain following a fall. Based on pelvic radiography, she was diagnosed with an unstable pelvic fracture. Her blood pressure was 60/40 mmHg, and owing to her unstable vital signs, emergency angiography was performed without computed tomography (CT). Both internal iliac arteries were embolized without sub-branch selection for prompt control of pelvic bleeding. Following embolization, her vital signs were stabilized. Subsequent CT revealed free intra-abdominal air, suggesting bowel perforation had occurred and necessitating emergency laparotomy. An approximately 1 cm-sized free perforation of the small intestine was identified intraoperatively, and primary closure was performed. A retroperitoneal hematoma identified intraoperatively was not explored further because it was a non-expanding and non-pulsatile mass. The patient was admitted to the Intensive Care Unit and transferred to the general ward on postoperative day 3. In this case, the hemodynamically stable pelvic fracture with bowel perforation was successfully and safely treated by prompt angioembolization without conducting CT.

The Numerical Study on Effect of the Droplet Sizes on Internal Mass Transfer in the Spray Type Scrubber (분무형 스크러버에 내에서 액적크기에 따른 물질전달에 관한 전산해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.19-32
    • /
    • 2019
  • As regional air pollution gets worse by the sulfur oxides emitted from various types of vessels passing through the many countries, the International Maritime Organization establishes the emission control areas and regulates sulfur dioxide in those areas. In order to satisfy these regional regulations, the fuel selection method and the exhaust gas post-treatment device are applied to the ships. Due to the economic reasons, the post-treatment method of exhaust gas for reducing the amount of sulfur oxides discharged is mainly preferred. The scrubber which is dominantly used in the ships are the spray type system where the sprayed liquid drops used for capturing the soluble sulfur dioxides in the exhaust gas. The performance of the spray type system depends on the size distribution of the sprayed droplets. In order to evaluate this performance, we designed counterflow type scrubber and cyclone scrubber and evaluated the desulfurization efficiency and the amount of droplet evaporation according to the size of each droplet by using computational fluid dynamics. The Eulerian-Eulerian analysis method was used because the scrubber had a gas-liquid two-phase flow inside the scrubber. When the diameter of the droplet was $100{\mu}m$, $300{\mu}m$, $500{\mu}m$ and $700{\mu}m$. As a result, both of scrubbers showed high desulfurization efficiency and low evaporation amount at $500{\mu}m$ and $700{\mu}m$.

Numerical Study of the Heat Removal Performance for a Passive Containment Cooling System using MARS-KS with a New Empirical Correlation of Steam Condensation (새로운 응축열전달계수 상관식이 적용된 MARS-KS를 활용한 원자로건물 피동냉각계통 열제거 성능의 수치적 연구)

  • Jang, Yeong-Jun;Lee, Yeon-Gun;Kim, Sin;Lim, Sang-Gyu
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-35
    • /
    • 2018
  • The passive containment cooling system (PCCS) has been designed to remove the released decay heat during the accident by means of the condensation heat transfer phenomenon to guarantee the safety of the nuclear power plant. The heat removal performance of the PCCS is mainly governed by the condensation heat transfer of the steam-air mixture. In this study, the heat removal performance of the PCCS was evaluated by using the MARS-KS code with a new empirical correlation for steam condensation in the presence of a noncondensable gas. A new empirical correlation implemented into the MARS-KS code was developed as a function of parameters that affect the condensation heat transfer coefficient, such as the pressure, the wall subcooling, the noncondensable gas mass fraction and the aspect ratio of the condenser tube. The empirical correlation was applied to the MARS-KS code to replace the default Colburn-Hougen model. The various thermal-hydraulic parameters during the operation of the PCCS follonwing a large-break loss-of-coolant-accident were analyzed. The transient pressure behavior inside the containment from the MARS-KS with the empirical correlation was compared with calculated with the Colburn-Hougen model.

A Study on Performance Evaluation of Early-age Concrete with EOS Fine Aggregate and GGBFS (EOS 잔골재 및 GGBFS를 혼입한 초기재령 콘크리트의 성능 평가에 관한 연구)

  • Kwon, Seung Jun;Cho, Sung Jun;Lim, Hee Seob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.113-119
    • /
    • 2019
  • Many researches on alternative materials as construction materials is continuing by recycling industrial byproducts due to shortage of sitereclamation and natural aggregates. In this paper, engineering properties in early-aged OPC (Ordinary Portland Cement) and GGBFS (Ground Granulated Blast Furnace Slag) concrete are evaluated with EOS aggregate replacement. The related experiments were carried out with 0.6 of water to binder ratio, three levels of EOS replacement ratios (0%, 30% and 50%) for fine aggregate, and two levels of cement replacement with GGBFS (0% and 40%). Several tests such as slump air content, and unit mass measurement are performed for fresh concrete, and compressive strength and diffusion coefficient referred to NT BUILD 492 method are measured for hardened concrete. Through the tests, it was evaluated that the compressive strength in concrete with EOS aggregate increased to 3 days and 7 days but slightly decreased at the age of 28 days. In the accelerated chloride penetration test, GGBFS concrete showed reduced diffusion coefficients by 60 - 67% compared with OPC concrete. The lowest chloride diffusion coefficient was evaluated in the 50% replacement with EOS aggregate, which showed an applicability of EOS aggregate to concrete production.

A study on the Optimization of Activated carbon Adsorbent Preparation condition and Evaluation of Application Supporting of K-Fe-Li ternary metal ions for Improving Adsorption Capacity of Hydrogen Sulfide (H2S) (황화수소(H2S) 흡착성능 증진을 위한 K-Fe-Li 3원계 금속이온물질이 담지된 활성탄 흡착제 제조조건 최적화 및 적용성 평가 연구)

  • Choi, Sung Yeol;Han, Dong hee;Kim, Sung Su
    • Clean Technology
    • /
    • v.25 no.3
    • /
    • pp.189-197
    • /
    • 2019
  • In this study an optimization of the preparation conditions of activated carbon with a ternary metal ion material to treat $H_2S$, which is classified as a representative odor substance, was carried out. For a metal ion material for enhancing the adsorption performance of hydrogen sulfide, performance enhancement was confirmed by combining Li and Fe or a ternary combination (K, Li, Fe) based on KI, which is a substance promoting hydrogen sulfide adsorption performance. Also, it was determined by XRD analysis that the reaction of each active substance with $H_2S$ was because of binding. The adsorption performance increased more than 3 times with heat treatment of the adsorbent with nitrogen compared with heat treatment with air. The maximum adsorption constant ($q_m$) value of the optimum adsorbent was 97.07, which is 6 times higher than that of the existing K-based impregnated activated carbon. It was confirmed that the objective adsorption amount ($0.3g\;g^{-1}$) was secured by an equilibrium between the mass transfer rate and adsorption rate. From the results, it was confirmed that the performance improvement was noticeable even when activated carbon with a reagent grade activated carbon particle size was modified. It was confirmed that the adsorption performance exists at high relative humidity levels of 60 and 100%, and the optimized preparation can be applied to a wet process such as a scrubber downstream.