• Title/Summary/Keyword: air kerma

Search Result 70, Processing Time 0.024 seconds

Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams (고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교)

  • 박창현;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • A few years ago, a proposal was made to change the dosimetry from the air kerma-based reference dosimetry to the absorbed dose-based reference dosimetry for all radiotherapy beams of ionizing radiation to improve the accuracy of dosimetry. Here, we present a dosimetry study in which the two most widespread absorbed dose­based protocols (IAEA TRS­398 and AAPM TG­51) were compared with an air kerma­based protocol (IAEA TRS-277) by measuring the absorbed dose in the same reference depth. Measurements were performed in three clinical electron beam energies using a PTW 30002 cylindrical chamber, and Markus and Roos plane­parallel chambers. $^{60}$ Co calibration factors were obtained from the KFDA. The absorbed dose differences between the air kerma­based and absorbed dose­based protocols were within 2.0% for all chambers in all beams. The results thus show that the obtained absolute dose values will be not significantly altered by changing from the air kerma­based dosimetry to the absorbed dose­based dosimetry. It was also shown that absorbed dose values between the absorbed dose­based protocols agreed by deviations of less than 0.5% for a cylindrical chamber and less than 0.7% for plane­parallel chambers using cross­calibration factors. Although the use of a cylindrical chamber and plane­parallel chambers resulted in a difference of less than 2% for all situations investigated here, to reduce errors, the plane­parallel chambers are recommended for electron energies in which the use of cylindrical chamber is not permitted in each protocol.

  • PDF

Evaluation of Energy Dependency for Air Kerma Area Product by RQR Beam Quality and Indirect Calibration (RQR 선질에 따른 공기커마 면적선량계의 에너지 의존성 평가와 간접 교정)

  • Kim, Jung-Su;Kim, Sung-Hwan;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.769-776
    • /
    • 2018
  • According IEC 60601-1 ed3.1 and IEC 60601-2-45 regulation, diagnostic X-ray equipment should be display to measured and calculated air kerma area product. On the clinical X ray equipment, air kerma area product dosimeter would like to have an evidence for dosimeter accuracy and energy dependency. This study was performed to indirect calibration and energy dependency test for attached type air kerma area product (KAP) dosimeter by RQR standards beam quality. On the RQR5 beam quality, attached KAP dosimeter error showed -7.5%, respectably. On the RQR9 beam quality, attached KAP dosimeter error showed -10.4%, respectably. All RQR beam quality, average absolute error was $8.30%{\pm}2.85%$, respectably. On this study, attached KAP dosimeter was satisfied to IEC 60580 and AAPM TG 190. This calibration method of KAP dosimeter will help to performance maintain for clinical KAP dosimeter.

The Quotient of Absorbed Dose and the Collision Part of Kerma for Photon Beams

  • Jun, Jae-Shik;Loevinger, Robert
    • Journal of Radiation Protection and Research
    • /
    • v.5 no.1
    • /
    • pp.7-10
    • /
    • 1980
  • With the conceptual definition of the quotient(${\beta}$) of absorbed dose and the collision part of kerma for photon beams, the procedure of computing ${\beta}$ is briefly described. A series of calculations of ${\beta}$ was carried out for photons of 0.4, 0.5, 1 and 2 MeV in polystyrene, carbon, air and aluminum. Resultant values are tabulated and evaluated.

  • PDF

The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source (기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발)

  • Huh, Hyun-Do;Kim, Woo-Chul;Loh, John-Jk;Lee, Suk;Lee, Sang-Hoon;Cho, Sam-Ju;Shin, Dong-Oh;Choi, Jin-Ho;Kwon, Soo-Il;Kim, Seong-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.232-237
    • /
    • 2006
  • The aim of this study was to develop the calculation algorithm of source strength of Ir-192 source In terms of the absorbed dose to water instead of an apparent activity (Ci). For this work the Multi Purpose Brachytherapy Phantom(MPBP) was developed, which was designed to locate the source and the chamber precisely at a specific position Inside the water phantom. The reference point of measurement was set at the 5 cm distance along the transverse axis of the source. For a brachytherapy source calibration, the absorbed dose to water calibration factor ($N_{D.W.Q}$) of an lonization chamber were determined and then apply standard protocols of absorbed dose to water. The calibration factor ($N_{D.W.Q}$) of the ion chamber (TM30013, PTW, Germany) was determined using the EGSnrcCPP Monte Carlo Code. The calculated calibration factor ($N_{D.W.Q}$) was 5.28 cGy/nC. The calculated factor was then used to determine the absorbed dose to water from which the air kerma strength for an Ir-192 source can be easily derived at the reference point (5 cm). The calculated air kerma strength showed discrepancies of -0.6% to +1.8% relative to the air kerma strength provided by the vendor, In this work we demonstrated that the air kerma strength ($S_k$) could be determined from the absorbed dose to water calibration factor for Ir-192 source. In audition, this source calibration method could be applied directly to the dose Calculation formalism of AAPM report TG-43.

  • PDF

Region-wise evaluation of gamma-ray exposure dose in decontamination operation after a nuclear accident

  • Jeong, Hae Sun;Hwang, Won Tae;Han, Moon Hee;Kim, Eun Han;Lee, Jo Eun;Lee, Cheol Woo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2652-2660
    • /
    • 2021
  • The gamma-ray exposure doses in decontamination operation after a nuclear accident were evaluated with a consideration of various geometrical conditions and specific gamma-ray energies. The calculation domain is organized with three residence types and each form is divided into two kinds of geometrical arrangements. The position-wise air KERMA values were calculated with an assumption of evenly distributed gamma-ray source based on Monte Carlo radiation transport analysis using the MCNP code. The radioactivity is initially set to be unity to be multiplied by the deposition value measured in the actual accident condition. The workforce data set depending on the target object was determined by modifying the Fukushima report. The external exposure doses for decontamination workers were derived from the calculated KERMA values and the workforce analysis. These results can be used to efficiently determine the workforce required by the characteristics of the area and the structure to be decontaminated within the dose limits.

Comparison of Air Kerma and Absorbed Dose to Water Based Protocols for High Energy Photon Beams: Theoretical and Experimental Study

  • Shin, Dong-Oh;Kim, Seong-Hoon;Seo, Won-Seop;Park, Sung-Yong;Park, Jin-Ho;Kang, Jin-Oh;Hong, Seong-Eon;Ahn, Hee-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.241-243
    • /
    • 2002
  • New types of protocols have been recently in development, all based on an absorbed dose-to-water with the aim of improving the accuracy of measurements of absorbed dose to water. IAEA TRS-277, the air-kerma standard-based present protocol, and IAEA TRS-398 and AAPM TG-51, the absorbed dose-to-water standard-based new one, were studied and compared theoretically and experimentally for photon beams of 6, 10, and 15 MV. NE 2571 and 3 Farmer types of ionization chambers in widely commercial use were used to determine an absorbed dose to water at the reference depth in water. Two different kinds of calibration factors were given respectively for every chamber calibrated in $\^$60/CO gamma ray beams from a Korean Secondary Standard Dosimetry Laboratory (KFDA). This work shows that there is around 1 % of difference of absorbed doses measured between two different types of calibration systems owing to different physical parameters and reference conditions used. We hope this work to help form the basis on development of new type of protocol in Korea.

  • PDF

A Method for Simultaneous Measurement of Air Kerma, Half Value Layer and Tube Potential in Quality Control Procedure of Diagnostic x ray units

  • Katoh, Tsuguhisa;Saitoh, Hidetoshi;Ohtani, Hiroki;Negishi, Tooru;Myojoyama, Atsushi;Ohno, Yuusuke;Sasaki, Takehito
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.294-297
    • /
    • 2002
  • For the quality control procedure of diagnostic x ray units, a method for simultaneous measurement of air kerma, half value layer and tube potential was developed utilizing a computed radiography system for intraoral radiography and film badge case. The response of average pixel values under the windows were calibrated by x rays generated at tube potentials from 40 to 140 kV with filtration from 1.5 to 3.7 mmAl. The calibration curves for half value layer and tube potential were derived as functions of attenuation factors by the 1.4 mmAl filter and the 0.2 mmCu filter. The energy dependency of the open window response was corrected by the calibration factor as a function of the attenuation factor by the 1.4 mmAl filter. The uncertainty of the estimated half value layer, tube potential and air kerma were 0.2 mmAl, 3.6 % and 5 %, respectively. It was thus suggested that this system could be applied to quality control program to detect the variation of working condition of x ray units in clinical use.

  • PDF

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Evaluation of Image Receptor Characteristics in Computed Radiography System Using Exposure Index in International Electrotechnical Commission (I) (IEC 규정 노출지수를 활용한 디지털 방사선 영상시스템에서의 영상 수용체간 특성평가 (I))

  • Park, Hyemin;Yoon, Yongsu;Roh, Younghoon;Kim, Sungjun;Na, Chanyoung;Han, Taeho;Kim, Jungsu;Jeong, hoiwoun;Kim, Jungmin
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.291-299
    • /
    • 2019
  • The International Electrotechnical Commission (IEC) has regulated the definition and requirements of the exposure index (EI). In this study, we calculated the EI of several image receptors in digital radiography system of two different manufacturers according to the method as per IEC, and evaluated the relationship with incident air kerma. To calculate the EI, w e obtained the characteristics curve of each image receptor by increasing the incident air kerma at RQA 3, 5, 7 and 9, respectively. As a result, there was no significant difference in the EI values between different image receptors of the same manufacturer, but EI values of different manufacturer was different despite the same air kerma was incident. Therefore, understanding the characteristics of the digital radiography systems is important in order to use EI as a tool for measuring and managing the radiation dose.

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.