• Title/Summary/Keyword: air injection

Search Result 1,199, Processing Time 0.027 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Iron and Manganese Removal through Well Development at River Bank Filtration Site (강변여과수 개발지역 우물 개량시 철망간 저감 효과)

  • Kim, Gyoo-Bum;Kim, Byung-Woo;Shin, Seon-Ho;Park, Joon-Hyeong
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.389-400
    • /
    • 2009
  • Iron and manganese contents are usually over the limit of drinking water standard (0.3 mg/L) in unconsolidated aquifer of river bank filtration site in Nakdong river. Surge block and air surging techniques used in this study are useful tools to remove the slime within gravels and pebbles, to increase permeability of aquifer, to provide oxygen into aquifer, and to discharge iron and manganese oxides from a well. Surging activity brought about $5{\sim}8$ and $5{\sim}9$ times decreases in $Fe_{(total)}$ and $Fe^{2+}$ contents, and also 10 times decrease in $Mn^{2+}$ contents compared to non-surging condition, respectively. Additionally, iron oxide and manganese oxide increased up $1{\sim}1.2$ times after surging. This result shows that air injection into the aquifer can help iron and manganese content decreased and in-situ treatment technology needs to be introduced in river bank filtration project in South Korea.

Pharmacokinetics and Excretion into Expired Air of Urea, a Potential Diagnosis Reagent of Helicobacter pylori Infection (헬리코박터 파이로리 균의 진단시약 개발을 위한 요소의 체내동태 및 호기 중 배설)

  • Park, Seung-Hyeok;Shin, Dae-Hwan;Cho, Han-Jun;Yim, Ju-Bin;Lim, Sung-Cil;Han, Kun;Chung, Youn-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.2
    • /
    • pp.160-166
    • /
    • 2012
  • Purpose: The purpose of the present study was to investigate the pharmacokinetics of urea, a new potential diagnosis reagent of Helicobacter pylori infection. Methods: Considering the mechanism of urea breath test, we determined the excretion of urea in expired air after its oral administration in rats and beagle dogs at the dose of 2 mg/kg (including 50 mCi/mmol $^{14}C$-urea 50 ${\mu}Ci/kg$ for rats and 13.5 ${\mu}Ci/kg$ for dogs). Results: Urea was rapidly disappeared from the blood circulation by 1 hr after its i.v. bolus injection, followed by a slow disappearance by 24 hr. The half-lives at the distributive phase ($t_{1/2{\alpha}}$) and post-distributive phase ($t_{1/2{\beta}}$) were 2 min and 6 hr, respectively. The bioavailability of urea was 64.3% after its oral administration. The values of the volume of distribution ($V_{dss}$) and the total body clearance ($CL_t$) after the oral administration were compatible with those after i.v. administration. The recovery of urea in the bile was about 0.1% of the dose by 24 hr after its oral administration. Urea was extensively eliminated in the urine by 48 hr. The recovery ratios of urea in the urine and expired air were about 86.8% and 2.99% of the dose by 48 hr, respectively. Moreover, urea was mostly distributed from the blood circulation to the kidney, followed by being eliminated in the urine without metabolism. The concentration of urea in the kidney was 4.0 times higher than that of plasma at 40 min after its oral administration. Conclusions: These findings indicated that oral route appears to be available for the administration of urea. Orally administered urea, thus, was considered to be useful for the diagnosis of Helicobacter pylori infection.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble (나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가)

  • Lee, Hyung-Don;Lee, Seung-Hwan;Park, Chan-gyu
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • Air pollutants in a subway are complexly caused by outdoor factors such as ventilating opening and indoor factors such as the movement of passengers on the subway. According to recent research results, most of the air pollutants generated in subway tunnels and stations are caused by indoor variables such as train movement. To control air pollutants such as particulate matter (PM), a prevention facility such as the electrostatic precipitator (EP) or bag filter collector was required in a subway station. In particular, the PM removed by the EP must be kept clean continuously to manage PM effectively. Therefore, a nano-bubbling washing system was developed in this study to clean a contaminated collecting plate in an EP at the main subway tunnel in Seoul. Removal efficiency compared with normal water and nano-bubbling water was likewise studied. As a result, the washing efficiency of collective PM increased in accordance with the increasing of injection pressure, with nano bubbling washing being 130.8% higher than tap water. According to increase in washing times, the maximum washing efficiency was 143.1% higher than tap water, but suitable washing times were less than 3 times. According to the results of the washing efficiency by variation of residence time, it was confirmed that the maximum residence time of nano-bubble water was maintained within 5 minutes.

An Improved Manufacturing Method of p-Dicyclopentadiene (DCPD) using Tungsten Type Catalyst in Air Condition (대기 조건에서 경화가 가능한 텅스텐계 p-DCPD의 개선된 성형 방법)

  • Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Park, Joung-Man
    • Composites Research
    • /
    • v.29 no.4
    • /
    • pp.216-222
    • /
    • 2016
  • Ring-opening metathesis polymerization of p-dicyclopentadiene (DCPD) can be performed using the tungsten type catalyst. This reaction usually progresses in nitrogen condition, because the catalysts are extremely sensitive in air condition. To solve this problem, DCPD resin with tungsten (W) was cured using hot press after stirring of DCPD A and B liquid in air condition. Mechanical properties of DCPD were improved by reducing microvoid occurrence successfully by using hot press method. It might be because hot press could provide sufficient press on DCPD specimen. Addition of catalyst was not effective for the curing of resin in a short time. During polymerization, pressure and temperature had a great influence on the mechanical properties of DCPD.

A Study on the Effect of Sulfur Content in Fuel Oil on the Emission of Air Pollutants According to Operating Conditions of Small Ship Engines (선박용 소형 엔진에서 연료유 내 황 함유량이 운전 조건에 따라 대기오염물질 배출에 미치는 영향에 관한 연구)

  • Lee, Kyeong-yeol;Rho, Beom-seok;Lee, Won-Ju;Choi, Jae-hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.834-840
    • /
    • 2018
  • In this study, the characteristics of air pollutant emissions from ships' engines have been investigated by conducting E2 and E3 cycle mode tests. A engine 360Ps (Doosan L126TIH engine) and 400kW dynamometer Horiba-Schenck were utilized for engine tests. The FTIR analyzer and SPC were used to measure exhaust gas (NOx, SOx etc.) and PM (particulate matter), respectively. The results showed that the emissions of THC and CO produced from engine were increased with the increase of sulfur content in fuel oils at E2 and E3 cycle modes. The kinetic viscosity of the fuel increased as the sulfur content of the fuel increased, thereby the specific fuel oil consumption (SFC) of the engine improved. This result is considered to be due to improved combustion conditions due to increased average diameters of sprayed particles and due to increased kinetic viscosity under constant fuel injection pressure in this study. In the case of NOx emission, this study showed no significant change in amount of sulfur content.

Development of Nitrogen Cooling Equipment for Personalized Local Area (개인 맞춤형 국소부위 질소 냉각 장비 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.913-916
    • /
    • 2020
  • In this paper, we propose the development of nitrogen cooling equipment for personalized local area. The proposed equipment consists of a cold air supply module, a body, and nitrogen injection with the following characteristics. First, it automatically controls the amount and time of cold air supply by utilizing information measuring skin temperature with volumetric temperature sensors, so it can have a competitive edge in function by ensuring complete safety. Second, if the distance measuring sensor is applied to the skin for more than a certain distance, it can block the cold air or control the discharge of nitrogen in conjunction with the control GUI to improve the efficiency of higher cooling therapy while providing safe management. Third, by installing a control module that can control the supply of nitrogen, the cost of maintenance can be minimized by minimizing the loss of nitrogen. Experiments at an external testing agency to evaluate the performance of the proposed equipment showed that the accuracy of the temperature sensor was measured in the range of ±3.8%, which is lower than the world's highest level(±5%), with a range of 110℃ to -160℃ similar to the world's highest level. Distance accuracy was measured in the range of ±3.0%, lower than the world's highest level(±5%), and weight accuracy in the range of ±0.1%, lower than the world's highest level(±5%). In addition, emission control was measured in four stages, higher than the world's highest level(stage 1) and nitrogen use was measured at 0.8L/min below the world's highest(6L/min). Therefore, the effectiveness of the methods proposed in this paper was demonstrated because they produced the same results as the world's highest levels.

Simulation Analysis of Sludge Disposal and Volatile Fatty Acids Production from Gravity Pressure Reactor via Wet Air Oxidation (습식산화반응을 통한 중력식반응기로부터의 슬러지 처리 및 유기산 생산 공정모사)

  • Park, Gwon Woo;Seo, Tae Wan;Lee, Hong-Cheol;Hwang, In-Ju
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.248-254
    • /
    • 2016
  • Efficacious wastewater treatment is essential for increasing sewage sludge volume and implementing strict environmental regulations. The operation cost of sludge treatment amounts up to 50% of the total costs for wastewater treatment plants, therefore, an economical sludge destruction method is crucially needed. Amid several destruction methods, wet air oxidation (WAO) can efficiently treat wastewater containing organic pollutants. It can be used not only for sludge destruction but also for useful by-product production. Volatile fatty acids (VFAs), one of many byproducts, is considered to be an important precursor of biofuel and chemical materials. Its high reaction condition has instituted the study of gravity pressure reactor (GPR) for an economical process of WAO to reduce operation cost. Simulation of subcritical condition was conducted using Aspen Plus with predictive Soave-Redlich-Kwong (PSRK) equation of state. Conjointly, simulation analysis for GPR depth, oxidizer type, sludge flow rate and oxidizer injection position was carried out. At GPR depth of 1000m and flow rate of 2 ton/h, the conversion and yield of VFAs were 92.02% and 0.17g/g, respectively.

Combustion Characteristics and On-site Performance Test of a Double-cone Partial Premixed Nozzle with Various Fuel hole Patterns (이중 콘형 부분예혼합 GT 연료노즐의 연소특성 및 발전플랜트 실증)

  • Kim, Han Seok;Cho, Ju Hyeong;Kim, Min Kuk;Hwang, Jeongjae;Lee, Won June;Min, Kyungwook;Kang, Do Won
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.22-28
    • /
    • 2021
  • Combustion characteristics were examined experimentally for a swirl-stabilized double cone premixed burner nozzle used for industrial gas turbines for power generation. An original model and a variant with a different fuel injection pattern are tested to compare their combustion characteristics such as NOx, CO and stability in pressurized conditions with single burner-flame and in an ambient multi-flame conditions with multi-burners. Test results show that NOx emissions are smaller for the variant, whose number of fuel holes is reduced with the same total area of fuel holes, in ambient and pressurized single-flame conditions with single burner, which results from enhanced fuel/air mixing due to a higher penetration of fuel into the air stream. The multi-burnerflame test results show that NOx emissions are smaller for the variant due to reduced flame interactions, which, on the contrary, slightly reduces the stability margin. On-site test results fromin an actual power plants also show that NOx emissions are reduced for the variant, compared with the original one, which is in agreement with the lab test results stated above.