• Title/Summary/Keyword: air fluid analysis

Search Result 898, Processing Time 0.022 seconds

Effects of Blade Configuration on the Performance of Induced Gas Flotation Machine (익형 변화에 따른 유도공기부상기 성능특성 연구)

  • Song, You-Joon;Lee, Ji-Gu;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.41-46
    • /
    • 2017
  • The flotation performance of the induced gas flotation (IGF) machine is considerably influenced by geometric configurations of rotor and stator. The interaction of rotor and stator, which are the most important components in IGF, serves to mix the air bubbles. Thus, the understanding of flow characteristics and consequential analysis on the machine are essential for the optimal design of IGF. In this study, two-phase (water and air) flow characteristics in the forced-air mechanically stirred Dorr-Oliver flotation cell was investigated using ANSYS CFX. In addition, the void fraction and the velocity distributions are determined and presented with different blade configurations.

Thermal and Fluid Flow of the Air Layer in a Flat Type Solar Collector (평판형 태양열 집열판 공기층의 열 및 유체유동)

  • Bae, K.Y.;Yi, C.S.;Lee, K.S.;Chung, H.S.;Jeong, H.M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2001
  • This study represents numerical analysis on the thermal and fluid flow of the air layer in a solar collector. The boundary conditions was assumed that the top and bottom wall of the air layer have a heating and cooling surface, respectively, and this calculation model have a solid body with a cooling temperature of $20^{\circ}C$. As the results of simulations, the magnitudes of the velocity vectors and isotherms are increased proportionally to the tilt angles. As the tilt angle is increased, the mean Nusselt numbers are increased and the maximum value of the mean Nusselt number was appeared at tilt angle $\theta=75^{\circ}$.

  • PDF

FSI Analysis of Piston Tilting for Pneumatic Actuator (공압 액추에이터의 피스톤 틸팅에 관한 FSI 해석)

  • Jang, Sung-Cheol;Jung, Won Taick;Park, Woon-Jae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.3
    • /
    • pp.144-153
    • /
    • 2016
  • In this research performed on a pneumatic actuator, the air flow entering and exiting the cylinder, and the motion and deformation characteristics of the piston during operation of the actuator, were predicted. This was carried out by utilizing an FSI(Fluid-Structural Interaction) analysis technique that incorporates principles in computational fluid dynamics and structural stress analysis, and potential performance degradation factors were examined. Analysis results indicated that performance improvements could be made through design modifications. These include adding an inlet and outlet on the upper and lower sections of the cylinder in the conventional model, and increasing the number of sites for piston guide bars from three to four.

CFD flow analysis of 150mm shower heads depending on plasma pitch (플라즈마 피치에 따른 150mm 샤워헤드에 대한 CFD 유동해석)

  • Kim, Dong-Hwa;Kim, Ho-Bum;Cho, Chong-Du;Jeong, Dea-Kyo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.585-589
    • /
    • 2008
  • This study is performed to analyze the fluid flow about 150mm shower heads of semiconductor device. Under the air pressure, the ideal gas of moving fluid is injected as 5m/s velocity into inlet of shower heads and the flow distribution in shower heads is measured according to pitch of plasma distribution device. As results, the maximum and minimum value of fluid velocity are investigated with their position. The velocity values at outlet are also studied. From two experiment using the plasma distribution device, the results of CFD are compared with the experimental results. That results shows stable flow of fluid in that case of corrected design from CFD.

  • PDF

Implementation of Automation System for the Fluid Analysis of Axial Fan Using Supercomputer (슈퍼컴퓨터 활용 축류팬 유동해석 자동화 시스템 개발)

  • Kim, Myung-Il;Lee, Seung-Min;Lee, Sang-Min
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.288-291
    • /
    • 2008
  • Recently, the importance and necessity of engineering analysis has shown a steady growth. However, researchers working in small and medium enterprises know little about the usefulness of engineering analysis and suffer from lack of technical knowledge. Axial fan is air fluid machinery in various fields of industry such as automobile, electric appliance, and heavy machinery. It is also a time and budget consuming equipment to develop the axial fan through physical experiments. In order to overcome this problem, we have designed and developed a web-base automated simulator for axial fan's fluid analysis using supercomputer. Automated simulator means that all of processes for engineering analysis including pre-process, solving, and post-process can be performed automatically without user intervention after transferring fan model(CAD files) made by user. After executing the simulator with some parameters, user can receive the report including pressure P and flow rate Q. In this paper, we introduce the architecture of our easy and efficient automated engineering analysis simulator, related techniques and result of development.

  • PDF

Computational Flow Analysis with Geometric and Operating Conditions of Air Lift Pump (기포펌프의 형상 및 작동 조건에 따른 전산유동해석)

  • Kang, Geonhan;Kim, Sungcho;Choi, Jongwook
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.2
    • /
    • pp.18-27
    • /
    • 2020
  • Air lift pump operated by buoyancy is mainly used for the continuous circulation and the purification of fluids. In this study, the computational flow analysis has been performed with the geometric and operating conditions of the air lift pump. The numerical data from the analysis have been verified by comparing with the previous experimental data. The following results are obtained which advance the efficiency of the air lift pump. As the submergence length of pipe increases and the pipe length over the water surface decreases, the non-dimensional mass flow ratio increases in both cases. When the position of the air injection hole is within the pipe, the circulation range of the surrounding fluid becomes widened with the distance between the air injection hole and the pipe inlet relatively becoming narrower. It is more efficient both when the air injection velocity is at 10 m/s and at 15 m/s, and when the diameter of the pipe with holes is doubled near the water surface. It is expected that these results can be provided as fundamental data for operating the air lift pump.

Study on fluid flow characteristics of aquarium for optimum environment (최적 양식환경을 위한 수조식 양식장내의 유동특성에 관한 연구)

  • 정효민;정한식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.108-117
    • /
    • 1998
  • This study was performed to analyze the fluid flow characteristics and the temperature distribution of the aquarium for fish breeding. In this study, the finite volume method and turbulence k-$\varepsilon$ model with the SIMPLE computational algorithm are used to study the water flow in the aquarium. The calculation parameters are the circulating flow rate and the basin depth, and the experiments were carried out for the water flow visualization This numerical analysis gives reasonable velocity distributions in good agreement with the experimental data. As the results of the three dimmentional simulations, the sectional mean velocity increased as the sectional mean temperature increases for constant basin depth, and the mean velocity increased more rapidly for small basin depth than that of large basin depth, The mean velocity and temperature can be expressed as the function of the circulating flow rates and the basin depth.

  • PDF

Flow Analysis of the Modified Power-Law Non-Newtonian Fluids in the Stenotic Tubes (수정멱법칙 비뉴턴유체의 협착관내 유동장해석)

  • Sub, S.H.;Yoo, S.S.;Chang, N.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.227-236
    • /
    • 1994
  • Steady flows of Newtonian and non-Newtonian fluids in the stenotic tubes with various stenotic shapes are numerically simulated. Validity of the modified power-law model as a constitutive equation for the purely viscous non-Newtonian fluid is discussed and the results of the power-law model are compared with those of the Carreau model, the Powell-Eyring model and experimental data for blood. Flow characteristics and reattachment lengths for non-Newtonian fluids in the stenotic tubes are presented extensively. Also, the analysis is extended to predict the influences of diameter ratio, stenosis spacing, number of stenosis and Reynolds number on the flow characteristics in the multiple stenotic tubes.

  • PDF

Simulation of Static Characteristics of Railway Vehicle's Airspring (철도차량용 공기 스프링의 정적 특성 시뮬레이션)

  • Heo, Sin;Gu, Jeong-Seo;U, Chang-Su;Kim, Yu-Il
    • 연구논문집
    • /
    • s.26
    • /
    • pp.15-24
    • /
    • 1996
  • In this study, we performed the static analysis of a cord-reinforced rubber airspring and generated the three-dimensional half-symmetry model which use the finite-strain shell elements to model the airbag. the three-dimensional hydrostatic fluid elements to model the air-filled cavity, and the rebar elements to model the multi-ply nylon reinforcement of airbag. In addition, a three-dimensional rigid surface is used to define the contact between the airspring and metal bead. The air inside the airspring cavity has been modeled as a compressible fluid satisfying the ideal gas law. The conclusions of this study are as follows. 1) In the pressurization step of analysis, we could predict the change of vertical reaction force, cavity volume and pressure within the airspring. 2) In the second step of analyzing vertical static stiffness, the increase of the vertical load increases the vertical stiffness. 3) In case of changing the angle of nylon cord, the increase the angle of nylon cord increases the vertical stiffness.

  • PDF

Analysis on Performance of Axial Flow Fan for Outdoor Unit of Air-conditioner: Flow Characteristics (에어컨 실외기용 축류홴의 성능에 관한 연구: 유동 특성)

  • Kim, Yong-Hwan;Jeong, Jin-Hwan;Lee, Jang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.30-35
    • /
    • 2010
  • The aerodynamic performance of axial flow fans for outdoor unit of air-conditioner is investigated by numerical and experimental approaches in this study. The pressure drop and volumetric flow rate are compared each other in several different conditions and fan speeds. It is shown that the predicted fan performances are quite well matched with the experimental results. It is also shown that the curvature of the fan arc and hub height have significant influences on the flow distribution after hub. By the results of this study, it can be suggested that several ways to improve the aerodynamic performance of the axial flow fan can be found using the numerical analysis.