• Title/Summary/Keyword: air filtration

Search Result 229, Processing Time 0.026 seconds

Treatability Study on the Remediation Groundwater Contaminated by TPH Cr6+ : Lab-Scale Experiment (TPH와 6가 크롬으로 오염된 지하수 처리를 위한 실내 실험)

  • Lee, Gyu-Beom;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.332-345
    • /
    • 2019
  • The purpose of the study is to evaluate the treatability of contaminated groundwater with TPH and (or) $Cr^{6+}$. Laboratory scale tests were performed for oil/water separation, dissolved air flotation (DAF), coagulation and precipitation, and filtration with sand and activated carbon respectively. Two times of oil/water separation tests for total 40 minutes of separation or separating time shows 90.2 % of TPH removal rate. In case of DAF test for high TPH sample, the TPH removal rates were not varied significantly by the variation of microbubble size. However, tests for low TPH samples show that TPH removal rate increases as microbubbles are smaller. When coagulant was added to sample for DAF test, TPH removal rate was increased 12.3 %. SS removal rate by DAF was 97.9 % at $16-40{\mu}m$ and it was increased as the size of microbubble is reduced. Tests for coagulation and precipitation were performed to evaluate the removal of $Cr^{6+}$ in groundwater. The increase of $FeSO_4$ dosage increased $Cr^{6+}$ removal rate in the coagulation and precipitation process. As the amount of activated carbon in the filter media increased TPH removal rate in the filtration process. SS removal rate by the filtration was 96.7 % similar to the results of DAF process tests. The filtration process treats TPH and SS. Best design parameters are determined as the size of sand is $425-850{\mu}m$ and the ratio of activated carbon and sand is 50:50.

Development of Electrospun Cellulose Acetate Membranes using Carbon Nanotubes for Filtration of Particulate Matter in the Air (전기방사를 이용한 탄소나노튜브 폴리머 공기정화 멤브레인 개발)

  • Park, Soyeon;Kim, Jaehyuk;Han, Sangil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.68-73
    • /
    • 2017
  • The removal of particulate matter ranging from $0.01{\mu}m{\sim}10{\mu}m$ can be performed by using membrane filters composed of fibers. Electrospinning techniques offer the production of very thin fibers with a uniform fiber diameter over conventional techniques including template synthesis, melt-blown, phase separation, etc. Air filtration will be improved with electrospun membranes due to the open pore structures, high porosity, and large surface area of the membranes. In the present study, filtration efficiency increased with pore size decrease and fiber density increase induced by carbon nanotube and the increased CA (cellulose acetate) concentration during electrospinning process.

Development Trend of Nanofiber Filter (나노섬유 필터의 개발 동향)

  • Kang Inn-Kyu;Kim Young-Jin;Byun Hong-Sik
    • Membrane Journal
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • Nanofiber is a broad phrase generally referring to a fiber with diameter less than 1 micron. Various polymers have been successfully electrospun into nanofibers in recent years. These nanofibers, due to their high surface area and porosity, have a great potential for use as filter medium, adsorption layers in protective clothing, etc. Nanofiber filters will enable new levels of filtration performance in the field of air filtration. In particular, nanofibers provide marked increases in filtration efficiency at relatively small pressure drop in permeability. Therefore, nanofiber filters could be substituted for conventional filter market due to the easy application of process and the possibility of coating to micron-sized non-woven sheets. This review is discussed on the trend of researche and development related to nanofiber filter including future marketability.

A Study on the Reverse Cleaning Flow Characteristics for High Temperature and High Pressure Filtration (고온 고압 집진을 위한 역세정 유동장의 특성에 관한 연구)

  • 김장우;정진도;김은권
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.25-31
    • /
    • 2003
  • Ceramic filter has been demonstrated as an attractive system to improve the thermal efficiency and to reduce the effluent pollutants. Removal of particulates from the hot gas stream is very important in air pollution control. In particular, the elimination of the particulate matters discharged from a gas turbine at high temperature can prevent the corrosion inside the IGCC. In this study, a Lab. scale test and numerical simulation were carried out to comprehend the relationship between pulse jet pressure and recovery of pressure drop and to characterize the reverse cleaning flow through a ceramic fil-ter element under high temperature and high pressure. When the pulse-jet pressures were 2, 3 and 4 kg/$ extrm{cm}^2$, the cleaning effect increase of about 10~30% by recovery of pressure drop caused by pulse pressure. Cleaning effect at 45$0^{\circ}C$ was greater than that at 55$0^{\circ}C$ or 650$^{\circ}$ for the same pulse pressure. According to the result of the present simulation, high pressure has been formed in terminal and central regions in our models and temperature distribution caused by pulse air is to be uniform comparatively on inner surface of filter.

Characteristic Analysis of Electret Filters made by Electrospinning (전기방사를 통한 정전필터제조 및 특성분석)

  • Ahn, Young-Chull;Kim, Gil-Tae;Kim, Seong-Kon;Lee, Jae-Keun;Kim, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1134-1138
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, electrical properties and filtration performance of electrospun filter media are quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. Electrospun filters show same collection efficiency with low pressure drop compare to commercialized HEPA filters. Surface charge potential and surface charge density of electrospun filters are increased with increasing applied voltage. Also collection efficiency of electrospun filters is increased with increasing surface charge potential and surface charge density.

  • PDF

Removal of Aerosol Through Fibrous Filter as a Function of Particle Size and Velocity (입자의 크기와 유속에 따른 섬유질 여과포에 의한 부유입자 제거 연구)

  • Sang Hoon Lee;Kwan Sik Chun;Hoo Keun Lee
    • Nuclear Engineering and Technology
    • /
    • v.16 no.1
    • /
    • pp.29-35
    • /
    • 1984
  • Filtration efficiency tests were conducted on a fiberglass mat filter with DOP aerosol having a diameter from 0.l${\mu}{\textrm}{m}$ to 0.45${\mu}{\textrm}{m}$ in the face velocity range of 1cm/sec to 10cm/sec. Filtration of submicron particles by a fibrous filter is characterized by a face velocity. The size of DOP aerosol which has a minimum removal efficiency decreases with increasing the velocity. A numerical solution of the diffusion equation is obtained for a fiberglass mat filter by using "Kuwabara's cell model" for the flow field and Von Mises Transformation for the actual flow around a fiberglass. The present theoretical results agree quite well with the experimentals for fiberglass mat. This result could be contributed to predict the removal efficiency on an air filter and to optimize the operating condition of an air purification system with a filter. a filter.

  • PDF

Filtration Performance Evaluation of Various Respiratory Face Masks Against Sub-Micron Particles (다양한 호흡기 보호용 면체 마스크의 서브 마이크론 입자에 대한 여과 성능 평가)

  • Zainul Alim Ali Murtadlo;Cho Hee-Joo;Park Hyun-Seol
    • Particle and aerosol research
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Respiratory face masks are protective facepieces that are designed to filter inhaled air. They are easy-to-use devices that can protect the wearer against various hazardous particles in the air. Respiratory face masks also prevent the spread of viruses and bacteria-containing droplets that are released from the coughing or sneezing of the infected people. During the COVID-19 pandemic, various types of face masks have circulated on the market. Their ability to filter sub-micron particles, which are the sizes of harmful particulate matter and airborne viruses, needs to be investigated. Their breathability, the easiness of breath through the mask, also needs to be considered. In this study, wwe evaluated the performance of filters used for different types of face masks certified by different standards including Korean (KF94, KF80, KF-AD), USA (N95), and Chinese (KN95) standards. We also tested the filters of nanofiber masks and surgical masks for which there are no standards for filtration test. The N95 mask filters showed the highest quality factor for capturing virus-sized particles. The other types of mask filters have acceptable performance except for nanofiber mask filters whose performance is very low.

Micro-Filtration Performance of Metal Membrane md Fouling Reduction by Intermittent Ozonation (금속 막의 정밀 여과 특성 및 간헐적 오존 처리에 의한 막 오염 저감)

  • 김종오;정종태
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.66-74
    • /
    • 2004
  • Total resistance of membrane in a micro-filtration system using a metal membrane was mainly attributed to the permeate resistance of cake layer($R_c$), which was formed by deposited particles from the physico-chemical interactions of solids on membrane surface. Intermittent back ozonation was highly effective than the air backwashing for fouling reduction. As far the operational effect, under same ozone injection, the increase of gas flow-rate was more favorable than the increase of injection time far the recovery of permeation flux. As the filtration time was longer, the effect of flux recovery by intermittent back-ozonation decreased. Therefore, it is preferable to operate membrane cleaning before the foulant is consolidated on membrane surface.

A Study on Application of The Available Geothermal Energy From Riverbank(including Alluvial and Riverbed deposits) Filtration (강변여과수(충적층 및 하상)의 열원을 이용한 지열에너지 활용에 관한 연구)

  • Kim, Hyoung-Soo;Jung, Woo-Sung;Ahn, Young-Sub;Hwang, Ki-Sup
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.209-214
    • /
    • 2006
  • In this study, application of groundwater thermal energy by use of riverbank filtration(RBF) system is reviewed and checked as an energy resources. Also, the cooling and heating system using RBF was developed in Chang-Won Waterwork site to examine the feasibility in real operation of the system. We estimates the roughly overall energy obtained from RBF system if the system is used in cooling and heating. The water temperature and room temperature have been monitored to evaluate the efficiency of the system and the preliminary results show that the geothermal energy obtained by RBF could be adopted in cooling and heating energy source efficiently.

  • PDF

A study on the disinfection performance of indoor microorganism using energy consumption analysis for indoor bio-safety (건물 재실자의 미생물 안전을 위한 면역건물 기술의 에너지 사용 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.