• Title/Summary/Keyword: air filter

Search Result 1,003, Processing Time 0.036 seconds

Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations (지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구)

  • Ahn, Y.C.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

Antibacterial Characteristics of Silver Nano-Particles Attached to Activated Carbon Filter (은나노를 부착한 활성탄 필터의 제균특성)

  • Heo, Ju-Yeong;Nam, Sang-Yeob;Kang, Jeong-Hee;Song, Ji-Hyeon;Kang, Byung-Ha;Han, Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.583-589
    • /
    • 2009
  • Activated carbon has long been used in purification processes for indoor air quality. However, the bioaerosol removal by activated carbon is not often sufficient to be used in an air control devise. In order to overcome these problems, silver nano-particles have been proposed as an antibacterial agent on the surface of activated carbon. Silver or silver ions have been known for antimicrobial activities. In this study, bioaerosol generated by using an Escherichia coli culture was introduced to a lab-scale column packed with activated carbon (AC) and silver nano-particles attached to activated carbon (Ag-AC). E. coli was almost completely removed in the Ag-AC column, whereas bioaerosol penetrated through the AC column. To determine the antibacterial effect of different filter materials in a full-scale air-handling system, another experiment was conducted using a wind tunnel equipped with a heat exchanger and three filter materials including commercial fabric, AC and Ag-AC. It was found that E. coli proliferated on the surface of the heat exchanger after 5 days, which dramatically increased bioaerosol counts in the effluent air stream. The fabric filter could not control the increased bioaerosol and most of the E. coli penetrated the filter. The bacterial removal efficiency was found to be approximately 45% in the AC filter, while the antibacterial efficiency increased to 70% using the Ag-AC filter. Consequently, the Ag-AC filter can be an effective method to control bioaerosol and improve indoor air quality.

Technology of VOC Removal in Air by Biotrickling Filter (생물살수여과법을 이용한 공기 중 VOC 제거 기술)

  • ;Marc A. Deshusses
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.101-112
    • /
    • 2003
  • Biological methods are frequently used for treatment of contaminated air, containing volatile organic compounds and odor compounds in low concentrations and high flow rate of air streams. For more than 20 years. biofilter has been recognized as a cost effective technology for the purification of contaminated air. Most commercial applications before 1990 were for control of odors. In the past decades major progress has been accomplished in the development of vapor phase bioreactor. in particular biotrickling filers. Biotrickling filters are more complex than biofilters. but are usually more effective, especially for the treatment of compounds which are difficult to degrade or compounds that generate acidic by-products. While the level of understanding of biotrickling filtration process for VOCs still remains limited. the evidence success of biotreatment of VOC in air resulted in pursuing active research. This paper presents fundamental and practical aspert of VOCs treatment from air in biotrickling filter. Special emphasis is given to the operating parameters and the factors influencing performance for biotrickling filter.

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

Collection Performance of an Electret Cabin Air Filter for Fine Particles (자동차용 정전 필터의 미세 입자 포집 특성)

  • Ji, Jun-Ho;Kang, Suk-Hoon;Kim, Dong-Choul;Hwang, Jung-Ho;Yoon, Woong-Sup;Bae, Gwi-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.85-90
    • /
    • 2001
  • This work presents experimental results of filter media test by using particles from $0.02\;to\;0.6{\mu}m$ in diameter and by applying different charging states. In order to investigate the electret filter performance, the collection efficiency and the pressure drop of filter were measured. The face velocities of test filters varied from 2.4 to 20.4 cm/s. Another experiment setup for the cartridge cabin air filter was used to get an collection efficiency in submicron region. After charging level of electret filter severely decreased, the change of collection efficiency was verified. Experimental results show that the reliability of electret filters can be poor in some conditions.

  • PDF

Test Method for Particle Removal Characteristic of Equipment Fan Filter Unit (EFFU) (Equipment Fan Filter Unit (EFFU)의 Particle 제거 성능평가 방법)

  • Lee, Yang-Woo;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.59-62
    • /
    • 2012
  • This test method covers a procedure for measuring particle removal characteristic of equipment fan filter unit(EFFU) installed inside of semiconductor process equipments, FPD manufacturing equipments and so on. Since EFFU is a combination of air filter and the assembly of fan, motor and frame, the integrity of these parts is very important for the performance of EFFU. So a conventional particle removal test method for air filters is not suitable for EFFU particle removal performance. This test method defines an evaluation method for EFFU which is installed inside an enclosed space to remove particles that are generated inside process equipment. The particle removal performance of EFFUs is usually depending on the performance of filter media and air flow rate. To understand a performance of an EFFU, the filter media characteristic, air flow rate and the integrity of EFFU parts should be considered simultaneously. This test method is intended to demonstrate the system performance of an EFFU and successfully evaluated EFFU performance characteristics.

A Study on the Flow Field Characteristics of Air Induction System for Reducing the Signal-to-Noise in the MAFS Output

  • Yoo, Seoung-Chool
    • Journal of ILASS-Korea
    • /
    • v.5 no.1
    • /
    • pp.49-57
    • /
    • 2000
  • This study presents the flow visualization results, velocity and turbulence intensity measurements made within an air filter cover and entry region of a mass air flow sensor (MAFS) which is used in an induction system of 3.8L engine. Flow structure in two air filter cover assemblies were examined. The first was a clear plastic replica of the production cover while the second was a modified clear plastic cover with a geometry configured to reduce fluctuations. High speed flow visualization and laser doppler velocimetry (LDV) systems were used to reveal and analyze the flow field characteristics encountered in the sensor design process under steady flow conditions. A 40-watt copper vapor laser was used as a light source. Its beam is focused down to a sheet of light approximately 1.5mm thick. The light scattered off the particles was recorded by a 16mm high speed rotating prism camera at 5000 frames per second. A comparison of the flow patterns and LDV measurements in the original and modified air filter covers is presented to illustrate the controlling effect of the cover design on the turbulence structure formation near the bypass and on the sensor output signal. In both axial and radial planes of the main passage it was found that the turbulence flow pattern is remarkably influenced by the air filter cover and main passage configuration.

  • PDF

Pre-study for the improvement of air filtration performance in the air handling unit of subway station (도시철도 지하역사 공기조화기의 미세먼지 저감성능 개선을 위한 사전연구)

  • Kang, Joong-Goo;Shin, Chang-Heon;Bae, Sung-Joon;Kwon, Soon-Bark;Kim, Se-Young;Han, Seok-Yoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.541-545
    • /
    • 2008
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator re used in the air handling unit (AHU) of subway station. However, those systems are faced to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts is malfunctioned due to the high load of particulates and the filter material needs periodic replacement. In this study, we surveyed the particle removal systems in order to develop the new system of particle removing can be adopted in the current AHU of subway station.

  • PDF

Production of air purification verification system using moss (이끼를 활용한 공기정화 검증 시스템 제작)

  • Ahn, Dohyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.587-591
    • /
    • 2019
  • Fine dust aerated in the atomsphere penetrates our lungs and blood lines through respiratory. Recent fine dust problems in Korea leads to development of various air purifiers. The researchers used this to study systems that could replace chemical filters. In order to compare the effect of the reduction of moss and conventional chemical filter(Hepa), a 1 cubic meter cube was prepared and the amount of the concentration of fine dust reduction was compared under controlled environment. Under the high concentration of fine dust, a test was done to figure out the reduction rate of the fine dust concentration by using air purification system with moss, hepa, and no filter. The air purification system(moss, hepa, and no filter) were operated 90 times in total, 30 times each. The test explains that the reduction of the fine dust amount and the rate of fine dust concentration. The results illustrate that the reduction of the amount fine dust was 138.93 after using air purification system with moss filter. In contrast, the usage of air purification system with hepa filter reduced the amount of fine dust to 76.57. And the air purification with no filter shows that the slight reduction of fine dust amount at 0.10. In the rate of fine dust concentration, moss filter was significantly higher than that of hepa, no filter (0.2379, 0.1298 and 0.0063 each). The results have confirmed that moss is effective in reducing fine dust concentration, and it is expected that with further improvement it can be used as a means to replace or supplement existing chemical filters in air purifier.

Performance Prediction of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 성능예측)

  • Kim Ki-Jung;Bae Gwi-Nam;Kim Youngil;Hur Nahmkeon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.313-316
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^{3}/h$. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and $100m^{3}/h$. The particle collection efficiency of a grease filter increases with increasing the particle diameter and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter The cut-off diameter of the tested grease filter representing $50-{\%}$ collection efficiency is about $11.6{\mu}m$ for water droplets at $100m^{3}/h$.

  • PDF