• 제목/요약/키워드: air cleaner

검색결과 195건 처리시간 0.029초

무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석 (An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer)

  • 오인환;이종현;이경훈;이정훈;이동섭;어성만;이미림
    • 한국축산시설환경학회지
    • /
    • 제12권3호
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구 (Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners)

  • 김학준;한방우;김용진;차성일
    • 한국입자에어로졸학회지
    • /
    • 제7권3호
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

실내 공간에서의 호흡기 감염병 공기전파감염 위험도와 공기정화장치(필터 임배디드 기계식 환기설비 및 공기청정기 등 실내 감염원 저감 장치) 사용에 따른 효율 (Airborne infection risk of respiratory infectious diseases and effectiveness of using filter-embeded mechanical ventilator and infectious source reduction device such as air cleaner)

  • 박성재;박근영;박대훈;구현본;황정호
    • 한국입자에어로졸학회지
    • /
    • 제16권4호
    • /
    • pp.73-94
    • /
    • 2020
  • Particulate infectious sources, including infectious viruses, can float in the air, causing airborne infections. To prevent indoor airborne infection, dilution control by ventilation and indoor air cleaners are frequently used. In this study, the risk of airborne infection by the operation of these two techniques was evaluated. In case of dilution control by ventilation, a high efficiency air filter was embedded at the inlet of supply air. In this study, infectious source reduction devices such as indoor air cleaner include all kinds of mechanical-filters, UV-photo catalysts and air ionizers through which air flow is forced by fans. Two mathematical models for influenza virus were applied in an infant care room where infants and young children are active, and the risk reduction efficiency was compared. As a result, in the case of individually operating the ventilator or the infectious source reduction device, the airborne infection risk reduction efficiencies were 55.2~61.2% and 53.8~59.9%, respectively. When both facilities were operated, it was found that the risk of airborne infection was reduced about 72.2~76.8%. Therefore, simultaneous operation of ventilation equipment and infectious source reduction device is the most effective method for safe environment that minimizes the risk of airborne infection of respiratory infectious diseases. In the case of a space where sufficient ventilation operation is difficult, it was found that the operation of an infectious source reduction device is important to prevent the spread of infectious diseases. This study is meaningful in that it provides an academic basis for strategies for preventing airborne infection of respiratory infectious diseases.

휴대용 유출기름회수기의 개발(II) - 공기흡입회수기의 제작과 성능시험 (Development of a Potable Skimmer(II) - Fabrication and Performance Test of an Air Suction Skimmer)

  • 박외철
    • 한국환경과학회지
    • /
    • 제3권2호
    • /
    • pp.177-184
    • /
    • 1994
  • An air suction skimmer was selected as a potable skimmer to be developed among the many reviewed skimmers because of its advantages such as simple structure, excellent transportability, and easy deployment. A prototype of the skimmer was fabricated. It was shown that the skimmer operated by a commercial vacuum cleaner has good performance. The maximum suction rate of water and the maximum suction head were 18$m^3$/hr and 2.7m, respectively.

  • PDF

시멘트 혼합토의 내구성 평가법에 관한 연구 (A Study on Durability Test of Cemented Soils)

  • 박성식;황세훈
    • 한국지반공학회논문집
    • /
    • 제28권11호
    • /
    • pp.79-86
    • /
    • 2012
  • 최근 소량의 시멘트를 혼합한 고결토가 도로 보조기층, 뒤채움재, 가물막이 댐 등 각종 토목 현장에서 많이 사용되고 있다. 이와 같이 시멘트비가 낮은 고결토는 반복되는 건습이나 다양한 풍화작용에 의해 내구성이 저하될 수 있다. 하지만 암석과 달리 고결토의 내구성을 평가하는 방법에 대한 연구는 부족한 실정이다. 따라서 본 연구에서는 기존의 슬레이크 내구성시험과 초음파 세척기를 이용하여 시멘트가 혼합된 고결토의 내구성을 평가하기 위한 시험법을 개발하고자 하였다. 고결모래의 시멘트비(4, 6, 8, 12%)를 달리하여 원기둥 형태의 공시체를 제작한 다음 수중 또는 대기중에서 3일 동안 양생하였다. 3일 양생 후 건조로에서 1일 동안 건조시킨 다음 다시 1일 동안 수침 시킨 후 슬레이크 내구성시험 및 초음파 세척기를 10분 또는 20분 동안 작동하여 시험 전후의 중량 손실 정도를 계산하여 내구성을 평가하였다. 시멘트비가 4%로 상당히 낮은 경우 고결모래의 중량 손실률은 7-25%인 초음파 세척기 시험법에 비해 슬레이크 내구성시험은 30-60%로 상대적으로 높았으나, 시멘트비가 8% 이상인 경우에는 두 시험방법 모두 중량 손실률이 10% 이내로 큰 차이가 없었다. 내구성지수는 시멘트비가 증가할수록 증가하였으며, 대기중 양생한 공시체보다 수중 양생한 공시체의 내구성지수가 높았다. 시멘트비가 낮은 고결토의 내구성을 평가하기에는 중량 손실이 많은 슬레이크 내구성시험보다 본 연구에서 새롭게 제안한 초음파 세척기를 이용한 시험법이 효과적임을 알 수 있었다.

가전제품 소음등급 기준설정에 관한 연구 (Study on Establishment of the Noise Grade Criteria for Household Appliances)

  • 박형규;이재원;이우석;한진석;구진회
    • 한국소음진동공학회논문집
    • /
    • 제22권12호
    • /
    • pp.1237-1242
    • /
    • 2012
  • No matter how low it might be, noise from home appliances in indoor environment cause displeasure for residents as it is produced nearby. Electronic goods including vacuum cleaner and washing machine generate high frequency noise, which interrupts TV-watching or conversations and cause noises between floors in apartment houses. In particular, refrigerators make constant noise late at night, hampering the study for exams and causing sleeplessness. Korea, despite the government's efforts to promote low-noise goods based on the noise test by corporation, there is a lack of standardization in the test method, test condition and measuring equipments. This is a major reason that lowers the reliability of low-noise products. At present, low-noise home appliances are certified with eco labeling in the nation but, only 7 brands of refrigerators, 4 brands of washing machines and 97 brands of air-conditioners obtained certification as of august, 2011. In addition, none of Kimchi-refrigerator and vacuum cleaner brands were approved as low-noise home appliances. This shows Korea's relatively underdeveloped market for low-noise products, which, in part, is because of the difficulties companies face in being certified with eco labeling as they should satisfy various requirements such as power-saving and eco-friendly design besides low-noise features. As a result, low-noise labeling for home appliances should be established for the revised noise and vibration management law and the study was carried out to establish low-noise labeling system for major noise sources including vacuum cleaner, washing machine, air-conditioner and refrigerator.

소형가전 및 컴퓨터용 송풍기의 현황 (A brief review of small fans used in appliances and computer)

  • 전완호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.161-164
    • /
    • 2002
  • Present condition of small fan used in appliances and IT industry is briefly reviewed. Here, fans used in refrigerator, air-conditioner, vacuum cleaner, microwave oven and computer are surveyed. Also some comments about the issue of each fan is described.

  • PDF

디젤엔진 연소공기 습식여과기의 개발에 관한 연구 (A Study on Development of the Wet Type Filter for Combustion Air of Diesel Engine)

  • 김용석;박성호;양순용
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.158-164
    • /
    • 2008
  • In this paper, the performance of wet type filter for diesel engine combustion air has been studied with effects of air temperature, humidity, and pressure. After experiments are performed without diesel engine, it has been investigated the applicability to diesel engine. Wet type filter for diesel engine combustion air had advantages that it is not necessary to change air filter and that engine exhaust gas is environmentally friendly due to low NOx and particulate emission. Also, the filtration performance has been carried out with smoke shell.

탈취제품의 탈취 성능 측정의 불확도 평가 (Uncertainty Evaluation in Measurement of Deodorization Efficiency of Indoor Air Cleaner)

  • 허귀석;신상만;김정우;이진홍
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.384-385
    • /
    • 2003
  • 일상 생활에서 악취로 인한 피해를 줄여 쾌적한 생활환경 유지에 대한 관심이 높아짐에 따라 이에 관련된 탈취제품이 많이 상품화되고 있다. 본 연구에서는 탈취 성능에 대하여 객관적으로 평가할 수 있는 시험 분석법을 개발하고, 탈취 성능 평가방법의 정확도를 확립하기 위해 단계별 불확도 평가를 수행하였다. 측정 불확도 요인을 체계적으로 평가하여 주요 불확도 요인을 파악하고 이를 최소화하기 위하여 어떠한 점을 주의하여야 하는 지를 조사하였다. (중략)

  • PDF